}

Tender For E-Tender For Supply Of Perfusion Items For Ctvs Department-2025-2027, delhi-Delhi

G B Pant Hospital has published Tender For E-Tender For Supply Of Perfusion Items For Ctvs Department-2025-2027. Submission Date for this Tender is 08-07-2025. Medical Equipment Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

49320601
Tender For E-Tender For Supply Of Perfusion Items For Ctvs Department-2025-2027
Tender
Indian
Delhi
Delhi
08-07-2025

Tender Documents

Tender Details

Tender For E-Tender For supply of Perfusion Items For Ctvs Department-2025-2027-1 item 1 ADULT MEMBRANE OXYGENATOR Priming volume should be less than 300 ml.• Blood flow range should be 0-7lts/min.• Oxygen transfer should be atleast 400ml/min.• Heat exchange efficiency should not be less than 0.50.• Housing material should be of polycarbonate.• Surface area of the fibers should be from 1.8m 2 to 2.4m 2 • Heat exchanger should be made of stainless steel and surface area should be approx. 20cm 2 Blood inlet port (from pump) 3/8 Blood outlet port 3/8 Cardioplegia port ¼ Gas Inlet port 1/4 Gas Outlet port 1/4 Water Ports ½ Maximum Pressure Blood inlet 1000 mmHg water Inlet 42 PSI• Blood storage capacity of hard shell reservoir should be approx. 4000ml• Minimum operating volume of reservoir should be 200ml.• Hard shell reservoir should have cardiotomy filter and de-foaming part• Hard-shell reservoir should have venous filter with pore size 452mm• The hard-shell reservoir should have Venous blood inlet port ½ Blood outlet port (to pump) ⅜ Suction ports (six) ¼ Water Inlet 42 PSI Vertical port to CR Filter ¼ Quick Prime port ¼ Auxiliary port ¼-⅜• Sustainable negative pressure should be 15010mmHg 2 item 2 PEDIATRIC MEMBRANE OXYGENATOR Priming volume should be less than 150ml.• Blood flow range should be 0.40.01ltrs/min.• Oxygen transfer should not be less than 250ml/min.• Pressure drop should be least-up to 100mmHg or less.• Heat exchange efficiency should not be less than 0.65.• Housing material should be of polycarbonate.• Surface area of the fibers should be approx. 1.0 to1.5m2.• Heat exchanger should be made of stainless steel and surface area should be approx. 1300cm 2. Blood inlet port 3/8 Blood outlet Port 3/8 Cardioplegia port 1/4 Gas Inlet Port 1/4 Gas Outlet port 1/4 Water Port ½ Maximum Pressure Blood inlet 1000mmHg, Water Inlet 42 PSI• Blood Storage capacity of hard shell reservoir should be max 3000ml.• Minimum operative volume of hard shell reservoir should be 100ml.• Hard-shell reservoir should have cardiotomy filter and defoaming part.• Hard-shell reservoir should have venous filter with pore size should be 20mm• The hard-shell reservoir should have• Venous blood inlet port 3/8 rotatable• Blood outlet port ( to pump) 3/8• Suction port(six) ¼• Vertical port to CR filter 3/8• Quick prime port ¼• Auxiliary port 3/8 Water Inlet 42 PSI 3 item 3 INFANT/NEONATAL MEMBRANE OXYGENATOR Blood flow range should be 0.1 – 2 liters/min.• Priming Volumes should be around 40 ml.• Oxygen transfer should be minimum 100 ml/min.• Pressure drop should be least up to 100mmHg or less.• Heat exchange efficiency should not be less than 0.65.• Housing material should be of polycarbonate.• Surface area of the fibers should be ≈0.22 to 0.5m2 and material should be micro porous polypropylene.• Heat exchanger should be made of stainless steel and surface area should be approx. 0.035m 2.• Blood inlet port (from pump) ¼ Blood outlet port ¼ Luer port (for recirculation or blood cardioplegia) one luer lock on blood outlet Gas inlet port ¼ Gas outlet port 5/16 Water ports ½ Maximum pressure Blood inlet 1000mmHg• Blood storage capacity of hard shell reservoir should be 1000ml• Minimum operating volume of hard-shell reservoir should be 15ml• Hard-shell reservoir should have cardiotomy filter and defoamer• The hard-shell should have• Venous blood inlet port ¼• Blood output port (to pump) ¼• Suction port (five) 3/16 • Quick prime port ¼• Vent port ¼• Auxiliary port ¼-3/8 Maximum sustainable negative pressure in reservoir -150mmHg Water inlet 2Kgf/cm 2 4 item 4 ADULT ECMO OXYGENATOR ECMO should have a validation for 14 days and should be phthalate free (NO DOP).• Membrane used should be of polymethyl pentene fibers.• Should have priming volume of≈250ml.• Should have contact surface area of 1.7-1.9 square meters. • Should cater for blood flow from 0.4 to 7 liters/ min.• Heat exchanger should have surface area of ≈0.8square meter.• Heat exchanger performance factor should be ≈0.6 (@ 4 liters /min).• Oxygenator and tubing should have coating of Phosphorylcholine (PC).• Inlet and outlet connections preferred is 3/8 (9.53 mm) 5 item 5 PEDIATRIC ECMO OXYGENATOR ECMO should have a validation for 14 days and should be phthalate free (NO DOP).• Membrane used should be of polymethyl pentene fibers.• Should have priming volume 200 ml.• Should have contact surface area of around1.4 square meters.• Should cater for blood flow from 0.3 to 4 liter /min.• Heat exchanger should have surface area of ≈0.8 square meter.• Heat exchanger performance factor should be of ≈0.6 (@ 4 liter/min).Oxygenator and tubing should have coating of Phosphorylcholine (PC).• Inlet and outlet connections preferred is 3/8(9.53 mm) 6 item 6 ADULT CUSTOM TUBING PACK : PRECONNECTEDMade from non-toxic medical grade PVC tubing (Implant tested). It is used exclusively in combination with heart lung machine and other devices of the system such as oxygenator and blood cardioplegia delivery system. Options of clear or colorful stripes tubing i.e. RED/BLUE/YELLOW/GREEN and with arterial line filter and with our filter is available. 7 item 7 PEDIATRIC CTP : PRECONNECTEDMade from non-toxic medical grade PVC tubing (Implant tested). It is used exclusively in combination with heart lung machine and other devices of the system such as oxygenator and blood cardioplegia delivery system.Options of clear or colorful stripes tubing i.e. RED/BLUE/YELLOW/GREEN and with arterial line filter and with our filter is available 8 item 8 BLOOD CARDIOLPLEGIA DELIVERY SET ADULTThe Cardioplegia Heat Exchanger aims to meet all the performance expectations with the following product features:a) Priming between 20-30 mlb) A flow dynamic engineering system which can effectively mix the blood and crystalloid solution to the desired preparations (1:4 & 4:1 ratios) Complete blood for warm shot also Allows delivery in any ratio either Delnido 4 part Crytalloid:1 blood) or Microplegia (1 part crystalloid and 4 part blood)c) Ports are available for infusion, sampling, temperature reading, and the inlet/outlet connector easily adapt 1/4 tubes for infant, pediatric and adult patient use.d) While priming, the perfusionist can easily purge air through the one port between the inlet and outlet with minimal holdup volume.e) The pleated anodized aluminium heat exchanger has minimum surface area, delivery froth -free, to allow the excellent mixing of blood with cardioplegia.f) An air trap column at the entry port provides additional safety by trapping any micro air bubbles going out.g) The bottom-in, top-out flow pathenables complete drainage with minimal blood holdup volume.h) The PVC recirculation lines are pre connected with their respective connectors to ensure easy setup and use.i) Available individually packed or pre connected with recirculation linej) Product has double protective packing that can be pealed easily when assemblingk) A cardioplegia Heat exchanger which can infuse the contents to the patient as and when the surgeons wants instantly without any delay.l) An in-built 200 μ Filter to prevent micro air bubbles. 9 item 9 ADULT HEMOFILTER MEMBRANESurface Area (Sq.m): 0.8 Priming Volume (cb.m): 58 Max. Trans pre (mm/Hg): 500 Max. Flow (ml/min): 150 Blood Inlet & Outlet: % 10 item 10 PEDIATRIC HEMOFILTER MEMBRANESurface Area (Sq.m): 0.4 Priming Volume (cb.m): 58Max. Trans pre (mm/Hg): 500Max. Flow (ml/min): 150 Blood Inlet & Outlet: ¼

Key Value

Document Fees
Refer document
EMD
INR 2333000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents-1 0 KB
Click here to download tender document Tender Documents-1 0 KB
Click here to download tender document Tender Documents-1 0 KB
Click here to download tender document Tender Documents-1 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail