| 1 | DESCRIPTION OF ITEM |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift, as directed by Engineer-incharge |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | Providing and injecting chemical emulsion for Preconstructional antitermite treatment and creating a chemical barrier under and alround the column pitswall trenches basement excavation top surface if plinth filling junction of wall and floor along the extemal perimer of binding expansion joints,surroundings of pipes and conduit etc. complete(Plinth area of the building at ground floor only shall be measuredas per I.S. 6313 (Part Il 1981) Aldrine emulsifiable concentrate or any other approved material such as Hepthachlor or chlordance will be used. The rateof applications of chemical emulsion |
| 5 | Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 4.20.1 All works upto plinth level : Concrete of M25 grade with minimum cement content of 300 kg /cum |
| 6 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 7 | As per the approved design, the Mudra Stambh shall be fabricated using fiber-reinforced glass with a thickness ranging from 8 to 12 mm, featuring UV protection. The structure will be supported internally by an MS (mild steel) frame and finished with two coats of golden paint. Each stambh will have a height of 11 feet and a base footprint of 3x3 square feet. Electrical Work (SITC): Each pillar will include the supply, installation, testing, and commissioning of the following: 8 nos. of IP65-rated, dustproof and water-resistant spotlights (9 watts each), upward facing, with a color temperature of 2700K–3000K. Complete electrical wiring including earthing, using 3-core 2.5 mm² copper armored cable (including earthing), suitable for 3-phase connections from pillar to pillar. FRLS (Fire Retardant Low Smoke) underground wiring with appropriate protective measures. Each pillar will be equipped to handle an 80-watt LED load along with the 8 spotlights and an individual MCB for safety. and any further changes |
| 8 | Electrical works |
| 9 | Supply of EXTERNAL LIGHTING PANEL as described below. ( TAKEN FOR( C)EXTERNAL LIGHTING PANEL-1Supply installing testing & commissioning of out door type External lighting Panel (Distribution Panel) compartmentalised design, dust tight & vermin proof made out of 14 gauge M.S. sheet, stove powder coated complete as required with following incomming & outgoing as per detail below.INCOMER1 No. 32 ADP MCB,10 kAbreaking capacity.1 No. 32 A TPN Contactor, Auto/Manual switch & Astronomical Watch Timers for 24 Hrs. settingMETERING & INDICATIONOUTGOINGS6 Nos. 16A DP MCBProvide the space in panel for provision of CCMS System.And Energy MeterALL EQUIPMENTS AND ITEMS INSTALLED SHALL BE AS PER - U.P.PWD/CPWD APPROVED MAKE |
| 10 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified |