| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils(B-44/1.8) |
| 2 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size). (B-54/3.1.7) |
| 3 | Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand). (B-69/6.1.6) |
| 4 | Random Rubble stone masonry with hard stone in superstructure aboveplinth level and upto five levelabove 30cm. thick walls in : Cement Mortar 1:6 ( 1-Cement : 6-Sand). Add extra for Wall upto 30cm. and less thickness. (B-69/6.2.6+6.3.4) |
| 5 | Add extra for facing as per design and detailed specifications including additional cost of stones Course rubble facing Second sort. (B-70/6.4.2) |
| 6 | Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix(B-59/4.1) |
| 7 | Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix(B-59/4.3) |
| 8 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc.(B-61/4.9) |
| 9 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. (B-61/4.10.2) |
| 10 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. (\"Original producers\" who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Cold twisted deformed bars (IS : 1786). (B-62/4.13.1) |
| 11 | Half brick masonry in Superstructure , above plinth level upto floor Vlevelusing bricks of designation 75Cement mortar 1 : 6 (1 cement : 6 coarse sand) (B-66/5.8.3) |
| 12 | Brick work in partition in super structure upto five storey 7cm. thick (brick on edges) using bricks of class designation 75 in : Cement mortar 1 : 4 (1 cement : 4 coarse sand) (B-66/5.10.2) |
| 13 | Supplying and fixing in walls machine cut and polished stone shelves, tands andin CM 1:3 with machine cut edges : Kota stone minimum 30mm thick. (B-72/6.17.3) |
| 14 | Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : Windows side hung /Ventilators top or centre hung (openable) (B-101/9.19.3) |
| 15 | Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. (B-102/9.26) |
| 16 | Providing and fixing Square bars or other flat welded to window, ventilatiors etc. (B-102/9.27) |
| 17 | Pointingonstonemasonryincementsandmortar 1:3 (1 cement : 3 sand) : Deep groove pointing(B-143/12.31.3) |
| 18 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 25mm thick (B-139/12.3.1) |
| 19 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 20mm thick (B-139/12.3.2) |
| 20 | 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) (B-139/12.5) |
| 21 | Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish : 25 mm thick (B-139/12.2.1) |
| 22 | Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). (B-55/3.2.4) |
| 23 | Providing & laying broken glazed titles on roof ( broken glazed tilesnot less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg ofVG-40 (30/40 )grade and 0.30 Kg/Sqm. OfVG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. (B-109/10.24) |
| 24 | Supply and fixing Jodhpur sand stone Machine cut Dash, Coping,sill,lintel fixed in cement sand mortar 1:4. 9 cm (3.5\") thick(B-82/6.88 (ii)) |
| 25 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. (B-98/9.5) |
| 26 | P & F UPVC SWR. pipes grade \"B\" for sciland wast discharge system (IS :13592-1992 marked) of approved make110 mm dia (S-257/3.44.2) |
| 27 | Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure \"A\": 30 mm thick . Commercial Veneer both side (B-93/8.13.2.1) |
| 28 | Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete For area of each slab upto 2001Sqcm (B-132/11.19.1) |
| 29 | White washing with lime to give an even shade including all scaffolding: New work (three or more coats). (B-143/ 12.34.1) |
| 30 | Finishing wall with water proofing cement paint of approved brand and manufacture and or required shadetogive an even shade including all scaffolding:New work (Two or more coats applied @ 3.84 kg/10 sqm).(B-145/12.41.1) |
| 31 | Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : Two or more coats on new work (B-146/ 12.46.1) |
| 32 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). (B-86/ 7.12) |
| 33 | Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). (B-86/ 7.13) |
| 34 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete.40mmthickwith20mmthicknominalsizeaggregate. (B-128/ 11.3.1) |
| 35 | Stone slab roofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both sides in cement sand mortar 1:4,with ceiling pointing in cement sand mortar 1 : 3 complete as per specification and instruction of Engineer In Charge (B-107/ 10.16) |
| 36 | Providing and fixing 1mm thick M.S. sheet garrage door shutters with frame of 40 x 40 x 6mm. angle iron 3mm M.S. gusset plates at the junction and corners including all fittings and applying a coat of approved steel primer : (Excluding cost of frames)(B-100/ 9.12.2) |
| 37 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :(B-109/10.22) |
| 38 | Finishing with neat cement (punning). (B-140/ 12.7) |
| 39 | P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (I.S. : 2556 Mark) with 100mm vitreous china P or S trap including cutting and making good the wall and floor:Size 580x440mm. (S-217/1.2.2) |
| 40 | P & F WVC wsh basin (Ist quality, I.S. : 2556 Mark) of approved make with C.I. brackets duly painted, 1 No. 15 mm C.P. Pillar cock (I.S. : 8934 Mark) & 32 mm C.P. brass waste coupling of approved make. 25 mm G.I. waste pipe complete including cutting & making good the wall. : Size 510 mm x 400mm (S-/1.36.2) |
| 41 | P & F Ist quality WVC Urinal (IS:2556 mark) with 25 mm dia G.I. waste pipe, dome couplings, concealed iron brackets or screws etc. complete. Flat Back (small) size 440x265x315 mm.(S/1.14.1) |
| 42 | P & F Marble Urinal Partition slab both sides polished of approved design cut from marble size 900x600mm. IS 2556 (Part VI Sec.4)-1995. Makrana \"Adanga\" or Raj Nagar IStQuality White or Andhi Indi-Italian marble.(S/1.16.3) |
| 43 | P & F G.I. pipes (Internal Work) with G.I. Fittings excluding union (IS:1239 Mark) & MS clamps including cutting and making good the walls and floors: (a) Exposed on wall 15 mm dia nominal bore \"B\" Class (S-229/2.1.1) |
| 44 | P & F G.I. pipes (Internal Work) with G.I. Fittings excluding union (IS:1239 Mark) & MS clamps including cutting and making good the walls and floors: (a) Exposed on wall 25 mm dia nominal bore \"B\" Class (S-229/2.1.3) |
| 45 | P & F G.I. pipes (ExternalWork) with G.I. fittings (IS: 1239 Mark) & MS clamps including cutting and making good the walls and floors: B class 15mm dia (S-230/2.2.1) |
| 46 | P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make.Brass 400 grm. 15 mm nominal bore (S-232/2.7.1) |
| 47 | P & F Ball Cock ( IS : 1703 Mark) with Rod & P.V.C. Ball complete: Brass wt. 400 gm., 15mm.(S-232/2.11.1) |
| 48 | P & F 15 mm. Dia Connection Pipe of approved quality/make:PVC pipe with C.P. Brass nuts upto length. 450 mm.(S-233/2.13.3) |
| 49 | P & F Flush Cock/Flush Valve (IS: 9758 Mark) for WC of approved quality make: Brass / Gun metel Half-turn wt. 1 kg. of approved quality/ make, 25 mm nominal bore (S-233/2.14.9) |
| 50 | P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. Inlet connection 15 mm Brass (IS:8931 marked). S-20/2.12.1 |
| 51 | P & F Full-way Value (IS: 778 Mark) or wheet valve of approved make.Gun - metal 25 mm nominal bore.(S-233/2.15.3) |
| 52 | P & F Full-way Value (IS: 778 Mark) or wheet valve of approved make.Gun - metal 15 mm nominal bore.(S-233/2.15.1) |
| 53 | P & F PVC Storege Tank (IS : 12701 marked indicating the BIS license No.), of approved make with cover, 25 mm dia 1 M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design:500 ltr. capacity (S-236/2.26.3) |
| 54 | P & F UPVC SWR. pipes grade \"B\" for sciland wast discharge system (IS :13592-1992 marked) of approved make75 mm dia (S-257/3.44.1) |
| 55 | P & F UPVC SWR. pipes grade \"B\" for sciland wast discharge system (IS :13592-1992 marked) of approved make110 mm dia (S-257/3.44.2) |
| 56 | P & F UPVC SWR. pipes grade \"B\" for sciland wast discharge system (IS :13592-1992 marked) of approved make110 mm dia cowel (S-259/ 3.45.30) |
| 57 | P & F UPVC SWR. pipes grade \"B\" for sciland wast discharge system (IS :13592-1992 marked) of approved make110 mm dia Tee with door( S-258/3.45.17) |
| 58 | P & F UPVC SWR. pipes grade \"B\" for sciland wast discharge system (IS :13592-1992 marked) of approved make 110 mm dia bend (S-257/3.45.4 ) 87.5 degree |
| 59 | P & F Square - month gully trap \"A\" grade (IS: marked) of approved make complete with C.I. grating, frame & Cover masonary chamber in C.M. 1:6, 100mm thick C.C. 1:5:10 base concrete, 40 mm thick C.C.M-15 grade coping, 12mm thick cement plaster in CM 1:3 complete as per approved design & type. Trap size 150 x 100 mm, RCC cover with frame, Internal Chamber size 300 x 300mm.(S-244/3.5.1) |
| 60 | Construction of manhole in all type of soil inner size 90x60 cm. thick masonary in CM 1:6, 10 Cm. thick cement concrete 1:5 10 in foundation, 20mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring making channels, 80mm thick stone slab covering with 40 mm thick M-15 grade C.C. flooring, RCC cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50mtr. lead. Depth up to 0.5 M (S-250/3.19.1) |
| 61 | Construction of soakage well in all type of soil 300mm thick dry masonry, top and bottom 300mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1:3, Ralthal, Kharanja, 40mm thick M-15 grade C.C. flooring, earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr. : Size 240 cm. dia outside & 240 Cm. Depth. (S-252/3.22.3) |
| 62 | Making connection to G I main to Distibution i/c all fitting upto 25 mm dia ( S-231/2.3.1) |
| 63 | P&F looking mirror of PVC frame ofappd make ( Atul or eq ) size 500x400 mm(S-223/1.45.1 ) |
| 64 | P&F towel rail or ring of appd quality or make Cp brass towel rail with bracket 600X20 mm heavy duty. (S-223/ 1.47.4) |
| 65 | Const of CC chamber 125 mm diafloor with stainless steel grating( S-255/ 3.39.4) |
| 66 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it\"sISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR E-1.1 (A) short poing (upt 3 mtr.) (1.1.1) |
| 67 | (B) Medium point (Upto 6.0 Mtr.)(1.1.2) |
| 68 | (C) Long point (Upto to 10.0 Mtr.)(1.1.3) |
| 69 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR2 x 2.5 sq. mm. + 1x1.5sqmm E- 4.1.7 |
| 70 | (B) 2x4.0 sq. mm + 1x 2.5 sq mm ( E-4.1.14) |
| 71 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it\"s ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR On board E- 1.3.1 |
| 72 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR E- 1.4.2 |
| 73 | Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR E-7.37 |
| 74 | Pipe Earthingas per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. \" B \" class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . E- 14.1 |
| 75 | SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . 0.5 HP, 1-Ø, (3 - 18)Mtr, (100-26) LPME- 21.7.1 |
| 76 | Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .10 SWG G.I. ( Hot Dipped) Wire E- 14.6.9 |
| 77 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR Single pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating (E-17/6.1.1.2) |
| 78 | Providing & Fixing of 240/415 V isolatorISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage,true contact indication,Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting,minimum phase termination capacity of 35sq.mm.IP 20 contact protection and fitted in existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR Double pole isolator 30 A / 40 A rating (E-18/6.2.1.1) |
| 79 | P & F Recessed/Surface mounting heavy duty horizontal type sheet steel Distribution board phosphatised/powder painted complete with suitable rating insulated Copper bus bar. Shorting link, neutral link, earth link & din bar, masking sheet, confirming to IS:13032 & 8623 including making internal DB terminations with Copper lugs, testing etc. as required. Single Door (Single Phase) 12-Way, Group-2. (E060514). |
| 80 | Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing E- 17.2.2 |
| 81 | Providing & Fixing of IP65 IK08 rated Integrated SMD Mid power LED bulk head typelight fixture made from Pressure Die Cast AL housing suitable with integral driver, systemlumen efficacy ≥100 lm/Watt output , THD < 10% ,p.f.≥0.95,CRI >80 , life time ofminimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum powerconsumption should not more than the specified rating and Fixture shall be of BIS standardand trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/Screen printing on housing. surge protection 4 KV. OEM must have its own in house NABLlab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report fromOEM shall be submitted. All as per pre approved by Engineer in charge. For additionaltechnical parameters of products/ work , refer Annexure \"A\" attached with this BSR .Minimum lumen output 1000 lm (E- 89/17.6.1) |
| 82 | P&F of ventilating fans capacitor start, copper wounded single phase with pvc impeller ABS body , automaticopenable louver shutter in existing opening including making connection, testing etc. as required. All as per pre approed by enginner incharge. For additional technical parameter of products/ work, refer Annexture \"A\" attached with BSR 250 mm sweep. E-15/ 15.13.3 |