Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-06-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 20-06-2025 |
| 2 | 29-05-2025 | BOQ CORRIGENDUM | BOQ | 13-06-2025 |
| Sl. No. | Item Description |
| 1 | Excavating in trenches n. exc. 1.5 m. wide and n. exc. 1.5 m. in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pire holes, etc. n. exc. 10 sqm on plan and not exc. 1.5 m. in depth and getting out in soft/loose soil complete all as specified and as directed. |
| 2 | M&L for sand cushioning for protection of cables (below, above and around the cable laid in trenches) complete using clean, dry sand complete all as specified and as directed. |
| 3 | Supply and laying well burnt bricks sub class \"B\" laid breadthwise along length of cable in trenches after sand cushioning laid for underground cable protection complete all as specified and as directed |
| 4 | Supply and laying 50 mm dia steel water tube light grade galvanised with all fittings laid in trenches for cable suporting complete all as specified and as directed. |
| 5 | Supply and laying 80 mm dia steel water tube light grade galvanised with all fittings laid in trenches for cable suporting complete all as specified and as directed. |
| 6 | Removing excavated soil not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point in soil complete all as specified and as directed. |
| 7 | Returning filling including spreading levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and as directed. |
| 8 | M&L for road cutting for laying of LT UG cable /Galvanised Iron Pipe complete all as specified and directed. |
| 9 | Supply and laying in trenches or fixing or passing through pipes or fixed to wall/pole 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductorof cross sectional area 95 Sqmm 3.5 core complete incl taking down unserviceable all as specified and as directed. |
| 10 | Supply and laying in trenches or fixing or passing through pipes or fixed to wall/pole 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductorof cross sectional area 70 Sqmm 3.5 core complete incl taking down unserviceable all as specified and as directed. |
| 11 | Supply and laying in trenches or fixing or passing through pipes or fixed to wall/pole 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductorof cross sectional area 50 Sqmm 3.5 core complete incl taking down unserviceable all as specified and as directed. |
| 12 | Supply and laying in trenches or fixing or passing through pipes or fixed to wall/pole 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductorof cross sectional area 16 Sqmm 4 core complete incl taking down unserviceable all as specified and as directed. |
| 13 | Supply and laying in trenches or fixing or passing through pipes or fixed to wall/pole 1100 volts grade XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductorof cross sectional area 10 Sqmm 2 core complete incl taking down unserviceable all as specified and as directed. |
| 14 | M & L Cable jointing kit for 1100 V grade cable for straight through (cold applied insulation and sealing system) heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 6-16 sqmm incl cutting of old jointing material including taking down old one complete all as specified and as directed. Make: Raychem/3M/Denson |
| 15 | M & L Cable jointing kit for 1100 V grade cable for straight through (cold applied insulation and sealing system) heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25-50 sqmm incl cutting of old jointing material including taking down old one complete all as specified and as directed. Make: Raychem/3M/Denson |
| 16 | M & L Cable jointing kit for 1100 V grade cable for straight through (cold applied insulation and sealing system) heat shrink type joint complete with jointing material and accessories suitable for 3.5/4.0 core XLPE armoured aluminium conductor cable of size 70-150 sqmm incl cutting of old jointing material including taking down old one complete all as specified and as directed. Make: Raychem/3M/Denson |
| 17 | Supply and laying in trenches or fixing or passing through pipes XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts earthed grade cross sectional area 95 sqmm complete incl taking down unserviceable all as specified and as directed. |
| 18 | Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm. |
| 19 | Cable jointing kit for 11 KV (Earthed)grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm incl taking down unserviceable all as specified and as directed. |
| 20 | Maintenance of transformer/voltage stabilizer by disconnecting the device from supply and draining out the complete oil, removing the body nut/bolts,gaskets complete replacement of silica gel, and arrest leakages if any inside the body, cleaning the breather vessel, cleaning the fins, scrubbing and removing the burnt oil sludge waste particles, replacement of complete rubber gasket and refixing the same with suitable size Nut /boltswith washers and refilling the drain outoil in transformer tank and charging the same to restore supply complete all as specified and as directed. |
| 21 | Dehydration & filteration of transformer/stabilizor oil by disconnecting the device from supply and draining out the complete oil, filtering the dirt, sludge and dehumidifying by heating the same and raising the Breakdown voltage level 60 KV at 2.5 mm gap and testing and recording the result for three times in specified interval including pouring the oil in transformer tank and charging the same to restore supply complete all as specified and as directed. |
| 22 | Supply and fix Auto cut relay PCB for AC Servo Voltage stabilizer,LT 400 KVA, 3 Phase, 415 Volts complete all as specified and directed. |
| 23 | Supply & filling only Transformer/Stabilizor Oil for topping up the level( after necessry disconnection and earthing both winding) with grade as per IS : 335 complete incl opening the tank cover and refixing the same and charging the transformer to the supply voltage complete all as specified and as directed. Note : Die electric strength of the oil shall be ensured not less than 60 KV before filling.Make of Oil -Poweroil/ Gulf |
| 24 | Maintenance of Vaccum circuit Breaker, Make: Schnieder, 12.0 KV Grade (For each set), rated normal current(breaker) 400 Amps by licensed electrician including the following:-(a)Switiching off VCB and conforming that supply to incomming end is properly disconnecte.(b)Opening covers of the VCB and visual checking of epoxy housing and all parts for rust and wear.(c)Cleaning all parts of breaker compartment with appropriate chemical to remove dust and dirt and wipping of the envelop of the vacuum interrupeter and insulating material with a clean and dry cloths.(d)Lubricating of rotary sections and moving parts, sliding surfaces, pins, coupling section etc by applying a small amount of grease/ petrolium jelly/ machine oil as applicable.(e)Checking of PTs, CTs control circuits, closing and tripping coil and all other parts.(f)Replacement of minor parts(rate deemed inclusive of the rate). Replacement ofdetective or less reliable parts from OEM (to be measured and paid separately under supply only items).(g) Cheaking auxilliary supply and control voltage, control circuits and tightening of all conections.Note : 1. After servicing of VCB, Health check up reports will be submitted. |
| 25 | Supply only current transformer of Vacuum Circuit Breakerincluding taking down old unserviceable all as specified as directed .Make: Schneider |
| 26 | Supply only Potential transformer of Vacuum Circuit Breakerincluding taking down old unserviceable all as specified as directed . |
| 27 | Supply only Digital multi-functional meter suitable for VCB including taking down old unserviceable all as specified and as directed. |
| 28 | Calibration of various relays of Vacuum Circuit Breaker (For each set of three) Complete all as specified and as directed.Note: Report of calibration to be submitted to the department. |
| 29 | Removing existing old paint by scraping from Vaccum circuit Breaker, Make: Schnieder, 12.0 KV Grade 400 Amp indoor (For each set of three), Interior and exterior and applying two coats of synthetic enamel paint (1st quality)by spraying including writing SM/MES No,capacity in white paint complete all as specified and directed. |
| 30 | Removing existing old paint by scraping from transformer of capacity 800 KVA , fins and conservator tank, and applying two coats of synthetic enamel paint (1st quality)by spraying including writing SM/MES No,capacity in white paint complete all as specified and directed. |
| 31 | Removing existing old paint by scraping from transformer of capacity 120 KVA , fins and conservator tank, and applying two coats of synthetic enamel paint (1st quality)by spraying including writing SM/MES No,capacity in white paint complete all as specified and directed. |
| 32 | Supply only electrical insulating mat type C conforming to IS 15652: 2006 for high tension appliance with size 1 Mtr x 2 Mtr including taking down old unserviceable all as specified as directed.Note: Test report to be submitted to the department. |
| 33 | Supply only electrical insulating mat type A conforming to IS 15652: 2006 for low tension appliance with standard width of 1.0 Mtr and in standard length including taking down old unserviceable all as specified as directedNote: Test report to be submitted to the department. |
| 34 | Disconnecting, repair and maintenance of APFC panel and replacement of internal wiring by new,checking and taking out defective unserviceable parts and replaced the same to make serviceable connection, testing etc.as directed.Note: (i) Maintenance / repairs shall be carried out by trained technicians/mechanic under supervision of qualified electrical technician. (ii)All repairs shall be carried out at site only.(iii) Major Spare / parts shall be measured and paid seperately as \"\"supply only\"\" |
| 35 | Supply only 5 to 15 KVAR capacitor,box series type-LTXL-Ultra heavy duty, 440V, including taking down old unserviceable all as specified as directed.Make- L&T/ABB/Neptune |
| 36 | Supply only capacitor duty contractors of 5 KVAR rating, type MO C5, size Fr 1including taking down old unserviceable all as specified as directed .Make- L&T/ABB/Neptune |
| 37 | Supply only capacitor duty contractors of 10 KVAR rating, type MO C10, size Fr 1including taking down old unserviceable all as specified as directed .Make- L&T/ABB/Neptune. |
| 38 | Supply only APFC Relay meter (8 Steps) complete including taking down old unserviceable all as specified as directed .Make- L&T/ABB/Neptune. |
| 39 | Repair/maint of LT Panel/Feeder pillar boxes by disconnecting all incomming and outgoing cable, check all internal wiring, voltmeter, ammeter, selector switches, RYB indicator lamps and re-connection after complete panel wiring with industrial copper multistranded unsheathed wire 16 Sqmm Single core (approx length 5 RM) with color code per phase and neutral with necessary cable ties, copper lugs at end the same complete with all respect incl insulation tape etcincluding repairs to the Panel hinges, Lock, handle etc all as specified and directed by Engr in Charge |
| 40 | S &F Indicator LED phase lamps 03 Nos (R, Y, B) including taking down old one complete all as specified and as directed. |
| 41 | S & F3 Ph Volt meter 0-500 Volts Digital Typeincluding taking down old one complete all as specified and as directed. |
| 42 | S & FAmmeter 0-500 AmpsDigital Type including taking down old one complete all as specified and as directed. |
| 43 | S & Fselector switch 3/4 position including taking down old one complete all as specified and as directed. |
| 44 | Supply and fixingMCCB, 160-200 Amps, 4 pole, 25 KA breaking capacity 415 Voltswith necessary cable lugs complete all as specified and directed including taking down old burnt/unserviceable one complete all as specified and directed. Make: L&T/Siemens/ABB./Legrand. |
| 45 | Supply and fixingMCCB, 125-160 Amps, 4 pole, 25 KA breaking capacity 415 Voltswith necessary cable lugs complete all as specified and directed including taking down old burnt/unserviceable one complete all as specified and directed. Make: L&T/Siemens/ABB./Legrand. |
| 46 | Supply and fixingMCCB, 16 to 125 Amps, 4pole, 18 KA breaking capacity 415 Voltswith necessary cable lugs complete all as specified and directed including taking down old burnt/unserviceable one complete all as specified and directed. Make: L&T/Siemens/ABB./Legrand. |
| 47 | M&L for painting of LT panels, APFC pannel, feeder pillar boxes, voltage stabilizors junction boxes, sheet metal enclosure and any othersteel surfaces complete with two coats of powder coated paint(1st quality) of approved colour by spraying after removing all dust/rust /grease including preparationof surface all as specified and directed.Note: Quoted rate also inclusive of white wash of PCC foundation of any size. |
| 48 | Earthing complete with GI earth plate electrode of size 60 x 60 x 0.6 cms burried directly in ground vertically at a depth of not less than 2.25 Mtrs below normal ground level with top edge of the earth plate at a depth not less than 1.5 Mtr below normal ground level surrounded from all sides by 15 cms thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI earth strip 25 x 4 mm size upto 7.5 mtr by means of bolts, nuts, checknuts and washers made out of galvanised iron and protected by medium grade 50 mm dia 5 mtr long and connected to main control panel and GI pipe 20 mm medium grade as watering pipe including funnel, wire mesh, PCC Pit made up of PCC 1:2:4 type C2 and RCC cover 40 mm thick with 8 mm bar 15 c/c including excavation and earth work all as specified in SSR Part 1 2009 including taking down unserviceable items all as specified and as directed. |
| 49 | Supply and fix MCB TPN 415V, 16-32 Amps capacity complete all as specified and directed.Make: Legrand/ABB/L&T/Siemens/Schenieider. |
| 50 | Supply and fix MCB TPN 415V, 40-100 Amps capacity complete all as specified and directed.Make: Legrand/ABB/L&T/Siemens/Schenieider. |
| 51 | Supply and fix MCB SPN 240V, 32 Amps capacity complete all as specified and directed.Make: Legrand/ABB/L&T/Siemens/Schenieider. |
| 52 | Supply and fix 3 Phase, 4 wire HT CT operated Energy meter50/5 Amps capacity, 0.5s, 16 Impulse/unit complete all as specified and directed.Make: Secure/Legrand/ABB/L&T/Siemens/Schenieider. |
| 53 | Supply and fix Moisture removal unit 2000 watts for existing VCB Room at substation. |
| 54 | Supply and fixingMCCB, 250 Amps, 4 pole, 36 KA breaking capacity 415 Voltswith necessary cable lugs complete all as specified and directed including taking down old burnt/unserviceable one complete all as specified and directed. Make: L&T/Siemens/ABB./Legrand. |
| 55 | Replacement of unserviceable /broken suitable HT/LT bushings with copper studs of transformers complete all as directed |
| 56 | Supply and fix Aluminium Cable Lugscomplete all as specified and directed. |
| 57 | (a) size 25 -50 mm dia |
| 58 | (b) size 70 -120 mm dia |
| 59 | Supply and fix Aluminium Ferrules complete all as specified and directed. |
| 60 | (a) size 25 -50 mm dia |
| 61 | (b) size 70 -120 mm dia |
| 62 | Attending emergency breakdown for electric supply and resolving the same within 24 hrs of reporting of complaints through any media.Note: Materials(cables and connecting items ,cablejoints,pipes and fittings) for rectification work will be measured separately. Rs 500.00 per day will be charged as penalty in case of non-compliance or non-rectification of job. |
| 63 | Excavating in trenches n. exc. 1.5 m. wide and n. exc. 1.5 m. in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pire holes, etc. n. exc. 10 sqm on plan and not exc. 1.5 m. in depth and getting out in soft/loose soil complete all as specified and as directed. |
| 64 | Removing excavated soil not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point in soil complete all as specified and as directed. |
| 65 | Returning filling including spreading levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and as directed. |
| 66 | Supply and laying 20 mm dia medium grade GI Pipe with all fittings laid in trenches/open incl taking down old inserviceablecomplete all as specified and as directed. |
| 67 | Supply and laying 25 mm dia medium grade GI Pipe with all fittings laid in trenches/open incl taking down old inserviceablecomplete all as specified and as directed. |
| 68 | Supply and laying 40 mm dia medium grade GI Pipe with all fittings laid in trenches/open incl taking down old inserviceable complete all as specified and as directed. |
| 69 | Supply and laying 50 mm dia medium grade GI Pipe with all fittings laid in trenches/open incl taking down old inserviceable complete all as specified and as directed. |
| 70 | Supply and laying 80 mm dia medium grade GI Pipe with all fittings laid in trenches/open incl taking down old inserviceable complete all as specified and as directed. |
| 71 | M&L for 100 mm dia ductile iron pipes with spigot and socket ends centrifugally cast. Class K-9, in any length, laid in trenches incl taking down old unserviceable complete all as specified and directed by Engr-In-Charge. |
| 72 | M&L for DI specials like Bends (any type, radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc) Tee pieces single branch \"Y\" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs for DI pipe upto 100mm bore as directed by Engr-in-Charge incl taking down old one as specified and as directed. |
| 73 | Supply and lay pipe MS Column/ERW heavy grade as per IS 3589(1981) of thickness 5.4 mm including all fittings such as bends, flanges, tee etc. , 100 mm (4\") dia including taking down old one all as specified and as directed. |
| 74 | Supply and lay pipe MS Column/ERW heavy grade as per IS 3589(1981) of thickness 5.4 mm including all fittings such as bends, flanges, tee etc. , 80 mm (3\") dia including taking down old one all as specified and as directed. |
| 75 | S&F 20 mm dia gun metal globe/gate valve with iron wheel head screwed both ends for iron pipes and fixed in existing position including taking down unserviceable one complete all as specified and as directed. |
| 76 | S&F 25 mm dia gun metal globe/gate valve with iron wheel head screwed both ends for iron pipes and fixed in existing position including taking down unserviceable one complete all as specified and as directed. |
| 77 | S&F 40 mm dia gun metal globe/gate valve with iron wheel head screwed both ends for iron pipes and fixed in existing position including taking down unserviceable one complete all as specified and as directed. |
| 78 | S&F 50 mm dia gun metal globe/gate valve with iron wheel head screwed both ends for iron pipes and fixed in existing position including taking down unserviceable one complete all as specified and as directed. |
| 79 | S&F 25 mm dia high pressure ball valve flanged at both ends for iron pipes and fixed in existing position including taking down unserviceable one complete all as specified and as directed. |
| 80 | Supply and fix for 100 mm dia D.I. resilient (soft) seated gate valve with pocket less body, ss stem (AISI 410), epdm coated di wedge 100% vaccum tight design with toroidal sealing rings & over 250 micron epoxy coating in PN16 designed to BS:5163/IS:14846 non-rising stem type with hand wheel operation including taking down old unserviceable one complete all as specified and as directed . |
| 81 | Supply and fix 100 mm dia DI resilient seated non-return valve, flanged end in swing type design with EPDM door and with over 250 micron epoxy coatingincluding all necessary items including taking down old unserviceable one complete all as specified and as directed. |
| 82 | S&F butter fly valve (water type) of size 100mm dia with fiber gasket including taking down old one complete all as specified and as directed. |
| 83 | Repair of Sluice valve/Non- return/Butterfly by taking out from site, dismantling, refacing, regrinding, repacking of stuffing box etc and fixing after necessary repair for smooth and leakage free operation and refixed at previous position incl rubber gasket at both flanged end,MS Nut bots,washer complete all as specified and directed for 80/100/150 mm valve. |
| 84 | Cutting GI/CI / DI / MS water pipein position for insertions of new fittings such as Tee, bend collar etc as required complete all as specified and as directed up to 150 mm dia pipes. |
| 85 | M&L for run lead joint for CI spigot and socket pipes & fittings 100 mm bore with new lead complete all as specified and as directed including burning out lead joint in position, including removing old lead complete. |
| 86 | M&L preparing old steel surfaces of any description width and girth and applying one coat of synthetic enamel paintall as specified and directed. |
| 87 | M&L one coat of synthetic enamel painting over a coat of red oxide primer after scraping,cleaningthe rusted surface with the help of sand paper / wire brushof the completeand after cleaning of rusted surface paintingwith the help of paintingbrush for all existing IR filter, Oxidation Chamber, Air Compressor andwater pipe network of IR Filter, existing panel and accessory, valve etc, all as per existing colour all as specified and directed. |
| 88 | Opening top cover of manhole by unscrewing the bolts of 45 cum/hrs capacity Oxidation chamber plant 800mm dia X 650 mm HOS, 3.5 Kg/mm2 pressure capacity ,unlloading the unsv MNO2 from upper portion of oxidation plant and disposal of unsv MnO2 within 100 metere radious from the existing filter plant and cleaning the inside chamber through chemical,brush etc and replacment of inactive MnO2 with fresh one complete all as entire satisfaction of complete all as specified and as directed. |
| 89 | Supply only new filter sand of 10 x 40 mesh from Barakar layer by layer as per designed layer to the pressure filters at different location complete all as specified and as directed. |
| 90 | Supply only new graded gravels of different size (Gravel of size 1.5\" x 1\",Pebbles of size 1\" x 1/2\",Core silex of size 1/2\" x 1/4\", Fine silex of size 1/4\" X 1/8\") inside the pressure filters at different location. |
| 91 | Repair / maintenace of air compressor as per existing capacity for oxidation chamber including replacement of air / oil seal, bearing, bushing, pinion gear, repair / replacement of crank and crank shaft, change of lub oil (compressor oil) including testing complete all as specified and directed. |
| 92 | Repair & servicing of chlorine dosing pump of cap 2 Ltr/hr incl 0.5 HP motor by replacement of unserviceable parts (i.e. bush/bearing etc) for smooth functioing of pumps at installations as directed and necessary testing complete all as specified and as directed.NOTE : i) Any minor repairs invloved to make the motor completely functional, even if not notified by the EIC, shall be carried out by the contractor without any extra cost to the department. ii) Parts likeStroke knob,inlet outlet PVC nozzle, PVC block, taflon washer, etcas reqd shall be done by the controctor without any extra cost to the department.) |
| 93 | Supply only PVC tubing for chlorine dozing pump complete all as specified & directed . |
| 94 | Repairing to Valve Pit chamber with replacement of valve pit GI sheet cover of existing size with MS handle, framing angle along with locking arrangement, PCC work in floor,brick work, plastering and whitwash of brick work complete incl taking down unsv items all as specified and directed. |
| 95 | Supply only chlorine test kit with colour sample complete all as specified and directed. |
| 96 | Supply only OT solution for chlorine test bottle(100 ml) complete all as specified and as directed. |
| 97 | S&FFully automatic star delta (FASD) Starter in sheet steel enclosure suitable for 15 HP motor with single phase protection feature, motor ratingAC- 3 duty, 415V, 50Hz, 3 phase,relay range 13-22 Amps including taking down old one complete all as specified and as directed. |
| 98 | M&L cleaning the internal surfaces of RCC overhead reservoir of capacity 20000 gallon at 18 metrestaging height by brooming and rubbing with coir brush, scraping with wire brushes,rubbing down scale, dirt, sludge etc.and washing with clear water using bleaching powder/caustic soda and taking out all rubbish from the reservoir and removing from the reservoircomplete all as specified and as directed. Note: Consumption of bleaching powder for cleaning of tank shall not be less than 15 Kg, wire brush, Broom sticks etc will be deemed included in the quoted rate and after cleaning of tank date of cleaning will also written by contractor in bold letters. |
| 99 | Taking out existing submersible pump set of any capacity along with column pipe from the bore well and lowering the same after repairing the pump setincluding and reconnection all electric & mechanical connection. Note: (i) One lifting & one lowering shall be measured one job. (ii) Repair to pumps & motor and replacement of spare parts shall be measured and paid separately. (iii) Replacement of column pipe if required shall be measured & paid separately as supply only under respective item in this Schedule. |
| 100 | Dismantling carefully submersible pump and taking out/down and replacement of locknut, impeller key, collar ring, SS coupling nuts, bolts, washer and re-assembling the pump of capacity upto 10/12.5/15 HP and painting the pump set with two coats of synthetic enamel paint over a coat of red oxide primer after scraping out old paint complete all as specified and directed.Note: Spare parts like Thrust bearing, Impeller, Sand Guard, Bush, Shaft, NRV if required shall be measured and paid separately under respective items in this Schedule as supply only. |
| 101 | Supply only Thrust bearing for submersible pump of capacity 10/12.5/15 HP incl taking down all as specified and directed |
| 102 | Supply only Gun Metal Impeller for submersible pump of capacity 10/12.5/15 HPincl taking down all as specified and directed |
| 103 | Supply only Sand Guard for submersible pump of capacity 10/12.5/15 HP incl taking down all as specified and directed |
| 104 | Supply only Gun Metal Bush for submersible pump of capacity 10/12.5/15 HPincl taking down all as specified and directed. |
| 105 | Supply only Stainless Steel Shaft for submersible pump of capacity 10/12.5/15 HP incl taking down all as specified and directed. |
| 106 | Supply only NRVfor submersible pump of capacity 10/12.5/15 HP incl taking down all as specified and directed. |
| 107 | M&L for rewinding of electric motor of 10/12.5/15 HP (Submersible motor) with super enamelled copper wire of existing gauge, varnishing dryingwith electric furnace process with taking down burnt winding, cleaning of stator and rooter including replacement ofbearing etc. including testing & commissioning complete all as specified and directed. |
| 108 | S&F PVC insulated water proof 3 core cable suitable for submersible pump set 1100 volts grade with standard copper conductor cable of size 6 sqmm complete all as specified and directed including taking down oldone. |
| 109 | S&F Steel wire rope 11/12 mm dia for holding protection of submersible pump set any capacity with assecessories complete all as specified and directed. |
| 110 | S&F Steel metal snap hook for holding the submersisible pumpset under water with steel wire rope complete all as specified and directed. |
| 111 | S&F Steel wire rope clip for any size complete all as specified and directed. |
| 112 | Material & labour forrewinding of openwell submersible pump motor 2.0 HP with super enamelled coper wire of existing gauge, varnishing drying with electric furnace process with taking down burnt winding,cleanining of stator and rotor including replacement of bush, bearing etc including old unserviceable parts change for pump andtesting & commissioning complete all as specified and directed. |
| 113 | S&F PVC insulated water proof 3 core cable suitable for submersible pump set 1100 volts grade with standard copper conductor cable of size 2.5 sqmm complete all as specified and directed including taking down oldone. |
| 114 | S & F DOL Stater with overload protection 2 HP capacity single phase including taking down old one all as specified and as directed. |
| 115 | Dismantling the PVC body multigrade filter unit, frontal pipe line and valves, un loading the media and cleaning media i.e pebbles, gravels using chemical, replacement of silex with new one, servicing of multi port valve, Refilling the media as per original complete including topping up and re-installation of unit & testing complete all as specified and directed.Note: media will be measured and paid separately. |
| 116 | All as per item No.51 here-in-before but softner unit.Note: media will be measured and paid separately. |
| 117 | Supply only \"Silex for multigrade softner filter. |
| 118 | Supply only \"Cores Silex for multigrade softner filter. |
| 119 | Supply only reverse osmosis micron cartiridge - 20\" including taking down existing worn out ones complete all as specified and directed. |
| 120 | Supply and fixing for R.O. micron cartridge housing-PP-20\"including taking out existing old one, complete all as specified and directed. |
| 121 | Supply and fixing ReverseOsmosis membrane(Element- 4040-0)including taking out existing wornout/chocked reverse osmosis membrane, complete all as specified and directed. |
| 122 | Supply and fixing for R.O. membrane housing(FRP)-4\" single element including taking out existing old one, complete all as specified and directed. |
| 123 | Supply and fixing SS ball valve of size 25mm(1\") dia including taking out existing old one, complete all as specified and directed. |
| 124 | Supply and fixing PP Adaptor for FRP vessel of size existing including taking out existing old one, complete all as specified and directed |
| 125 | Supply and fixing FRP vessel tank of size 100 ltr capacity or as existing type and capacity including taking out existing old one, complete all as specified and directed |
| 126 | S&F of HDPE/PVC strainer inside the multigrade, iron removal softening plant as per existing including taking down old unserviceable one complete all as specified and directed. |
| 127 | Supply and replacement of PVC body multiport valve, 40mm NB top mounted for filter, 25/32mm dia incl taking down exisiting unserviceable valve complete all as specified and directed |
| 128 | Cleaning of RO membrane duly taking out from RO plant, cleaning with Solution 1 to be used for inorganic fouling(Solution of Citric acid & RO product water duly adjusted to PH 4.0 with sodium hydroxide) and refixing the same of its original position and testing for leakage complete all as specified and directed. |
| 129 | M & L Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc, any typeof pipe of bore 25 mm complete all as specified and as directed. |
| 130 | Repair/Maint of monoblock booster pump set of capacity 1.2 HP, 1ph, 230V taking out existing winding and rewinding the same with super enamelled bare insulated copper winding wire as per existing gauge and turn to achieve required RPM, replacement of ball bearing,connection wire, cooling fan of motor, oiling etc complete testing all as specified and as directed. |
| 131 | Overhauling of RO plant monoblock pumping set of capacity 1.2 HP, 1ph, 220Vdismantling complete by opening the pump set form RO, cleaning of all parts i.e bushes bearing impellers, and replacement of coupling shaft seal and changing the Stainless steel casing of pump testing complete including re-installing at site and tested complete all as specified and directed. |
| 132 | Supply, fixing and testing of Microprocessor based Panel with provn for connectivity of 1ph high speed pressure pump(upto 5 HP) for ReverseOsmosis plantincluding taking out existing Panel, complete all as specified and directed. |
| 133 | Attending emergency breakdown for water supply equipments and resolving the same within 24 hrs of reporting of complaints through any media.Note: Materials for rectification work will be measured separately. Rs 500.00 per day will be charged as penalty in case of non-compliance or non-rectification of job. |
| 134 | M&L for cleaning of PVC product tank of capacity 100 ltr for RO plant with the help of suitable cleaning chemical and writing date of cleaning by synthetic paint all as specified and as directed. |
| 135 | Chemical analysis (Lab Test) : (Turbidity, PH, Total hardness, Iron (Organic & Inorganic Iron), Chlorides, Sulphates, Fluorides, Calcium,Colifrom Bacteria etc all the parameter as per IS) ofwater in various locations at NCB/SSB Diamond Harbour from Govt Approved / NABL accredited Laboratory including collection of water, Sterilized bottle for testing and submission of the test report.Note : Testing is to be carried out once in every month. |
| 136 | M&Lfor repairs in MS works of Framed brackets of angles or tees with web and flanges cut to shape, drilled and counter sunk for screw, including bending and welding angles, as necessary, gusset plates,MS Sheets riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 with one coat of synthetic enamel painting over a coat of red oxide primer all as specified and directed. |
| 137 | Supply and laying 90 mm dia HDPE double wall corrugated pipe with all fittings laid in trenches/open for cable protection complete all as specified and as directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail