Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 14-06-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 21-06-2025 |
| 2 | 05-06-2025 | CorrigendumNo01 | BOQ | 14-06-2025 |
| Sl. No. | Item Description |
| 1 | Dismantling of floor hearth/wall tiles including cement mortar bedding (but not backing) and removing serviceable tiles all as specified and directed. |
| 2 | M&L Non Skid coloured ceramic tiles 8-10 mm thick, area of each tiles exc 0.42 sqm but not exc 1 sqm each as in floors with 6 mm spacer filled with Epoxy hardner mixed with Sparkling golden powder or as slected by GE including 15mm thick screed bed or bedding layer in CM(1:6) set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles all as specified and directed. |
| 3 | M&L Glazed coloured ceramic tiles in vertical surface 600X 300X 7thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles including 10mm thick rendering coat in CM 1:4 on wallwith 6 mm spacer filled with Epoxy hardner mixed with Sparkling golden powder or as slected by GE all as specified and directed. |
| 4 | M&L Granite (of any type and size) 18-20 mm thick machine cut bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone over 15mm thick screed bed in CM 1:4 on kitchen platform, Cill of Window/Ventilator/ flooring/border etc including rubbing, grinding and polishing complete all as specified and directed |
| 5 | M&L 20-25 mm thick machine cut cudappa stone slab in horizental/vertical jambs laid and jointed with grey cement slurrymixed with pigment to match the shade of the slab including rubbing polishing & rounding to edges of slab as in window cills/jams including screed bedding 10mm thick in CM 1:6 all as specified and directed. |
| 6 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided all as specified and directed. |
| 7 | M&L brushing neat cement slurry 3.00 kg of cement per sqm all as specified and directed. |
| 8 | M&L PCC 1:2:4, type B1 (using 20 mm graded crushed stone aggregate) finishing surfaces even and rough to receivetiles all as specified and directed. |
| 9 | S&F 18 mm thick Both Side pre laminated HDH of any colour, matt surface finish,grade I, for frame and shutter for kitchen cabinets/ vanity complete with all necessary fittings like SS hinges, brass, handles and magnets all as specified and directed. |
| 10 | Demolition of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc. but excluding ashlar facing dressed stone work and precast concrete articles including removing debris out side MD land all as specified and directed. |
| 11 | M&L Brick work with sub class \"B\" bricks straight or curved on plan exc 6 metre mean radius built in CM 1:6 all as specified and directed. |
| 12 | M&L Brick work with sub class \"B\" brick straight or curved on plan in any raddius in half brick thick wallsbuilt in CM 1:4all as specified and directed. |
| 13 | Taking down cement plaster on brick/stone or concrete surfaces including racking out joints, hacking for key, scrubbing down with water to receive plaster,including removing debris/rubbish materials off the site out side MD land all as specified and directed. |
| 14 | M&L 12 mm thick Ready Mix Plaster in single layer, on other than fair faces of concrete surfaces in wall ( internal surface) and finished even and smooth without using extra cement all as specified and directed. |
| 15 | M&L 15-25 mm thick ready mix plaster in two layer with liquid water proofing compound on fair faces of brick wall or concrete surfaces, finished surfaces even and fair, including use of scaffolding all as specified and directed. |
| 16 | M&L for preparation of new/old plastered surfaces of wall and applying two coats of oil emulsion distemper over a coat of alkali resistant primer coat over 1.5 mm thick wall care putty through authorised applicators of paint manufacturers only of approved shade all as specified and directed |
| 17 | M&L for preparing new/old plastered surfaces of walls / ceilings by scrapping / rubbing and applying two coats of weather proof acrylic exterior paint (100% Acrylic)Base coat of Apex ultima protek duralife or equivalent and top coat of Apex Ultima protek, Make : Asian Paints or equivalent over a coat of alkali resistent primer through authorized applicator onlyincluding use of scaffoldings all as specified and directed. |
| 18 | M&L for old loose spalled concrete should be chiseled from roof ceiling with the help of scrapers chisele & hammer after that cleaning of rust from mild steel rod applying cement slurry spray 3.00 kg per sqm by paint brush over cleaned surface for8-10 mm thick ready mix plaster for ceilingon brick wall or concrete surfaces including making groove of appropriate size and finished surfaces even & smooth without using extra cement and two coat of OBD with 0.5 mm thick wall putty all as specified and directed. |
| 19 | M&L for Water proofing treatment to sunken slab /floors/walls etc and shall be carried out all as specified below and as directed.(a) Cleaning the sunken portion of Toilet/bath/WC/Kitchen throughly to remove the laitance, dirt etc and thrown out side the MD land.(b) Form angle fillet of size 50 mm X 50 mm along the junction of wall and floor using polymer modified mortar, Apply one coat of polymer coatingon all angle fillets by brush and cover it with 100 mm open glass fibre/ geotextile fibre mesh when it is still wet. Apply second coat of the same coating on the angle fillet and allow it to dry completely. (c) Sanitary pipe entering through walls and floor shall be sealed with bitumin based seal tape / epoxy bonding agent and gaps to be grouted with non shrink cementitious grout . Nahani traps etc to be fitted securely and gaps around it to be grouted in the same manner. (d) In the remaining area in dry substrate condition brush apply first coat of the acrylic cementious coating and further apply second coat in perpendicular direcion after 6-8 hours when first coat is dry, and sprinkling quartz sand for shearkey purpose on second coat in wet condition and allow to dry it completely, Extend the coating up to 1.2 mm above the FFL. Coverage of cementitiou coating to be maintained of min 1.8 kg per sqm for two coats.(e) Sunken portion to be tested for 72 hours for water tightness after only flooring work can be started. Cost for the same shall be deemed to be included in quoted rate.(f) After 2 to 3 days sunken portion must be overlaid with a 50 mm thick concrete screed 1:3:6 type B0 mixed with integral WPC liquid laid to slope 1:60 towards outer face of wall. Provide 40 mm OD CPVC pipe at the lowest point with 600 mm projection beyond the outer face of the wall, then filled up the sunken portion with lean concrete 1:4:8 type D2. (Note : lean concrete 1:4:8 paid saperatly)Note : All the material involved in sunken treatment shall be deemed to be included in quoted rateand only floor area will be measured for the payment purpose. |
| 20 | M&L PCC 1:4:8, type D2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concreteall as specified and directed. |
| 21 | Taking down chowkat with shutters (without taking off shutters from the frames ) area nexc 1.5 sqm each all as specified and directed. |
| 22 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw with drawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made all as specified and directed. |
| 23 | S&F factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 28-30 mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. Note: stainless steel butt hinges and necessary S S screws shall be paid separately)complete all as specified and directed |
| 24 | S&F 150 mm long aluminium alloy handle cast type anodized all as specified and directed. |
| 25 | S&F 150 mm long aluminium anodized barrel tower bolt of extruded section all as specified and directed. |
| 26 | S&F 100mmlong Aluminium butt hinges of extruded aluminium alloy with galvanized mild steel hinge, pin anodizedall as specified and directed. |
| 27 | S&F 200 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed all as specified and directed. |
| 28 | S&F factory made uPVC white colour fixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Glass shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 29 | M&L 3mm thick sheet glass Figured glass, pin head type and glazing with oil putty in square n-exc 0.5 sqm in each pane all as specified & directed. |
| 30 | S&Faluminium grill of 7.5mm x 5.2mm bars of opening as per design pattern No DG No 103 of M/s Decogrille/ RG-103 of M/s Royal Grill fixed with aluminium channel \"F \" 20mmx15mm fixed in position with screw all as specified and directed. |
| 31 | M&L in repairs galvanised Aluminium Wire cloth of 0.45 mm nominal dia of wire and average width of aparture 1.18 mm fixed with tinned tack for galvanized wire staple incl fixed all as specified & directed. |
| 32 | S&F in repairs pillar taps cost copper alloy fancy type with capstan head, chromium plated screwed down high pressure with or fly nuts screwed for 15 mm bore iron pipe and fixed all as Specified and directed. |
| 33 | S&F in repair Chromium plated brass Stop valve / angle valve for15mm bore pipe, fixed in repairs all as Specified and directed. |
| 34 | S&F in repairtwo way angle valve cock chromium plated brass fancy type bore 15mm all as Specified and directed. |
| 35 | S&F in repair vitreous china Wall Hung WC Rimless Bowl With Cistern and PP Soft Close Seat cover, Hinges, Dual Flush Cistern Fitting, Accessories Set, Size: 380x650x730 mm brown or any colour as decide by Engr in charge including making connection to trapand to flushing pipe and making good to floor all as Specified and directed. |
| 36 | S&F in repairs bevelled edge 5.5 mm thick mirror of selected quality glass, 600 x 450 mm size, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified and directed. |
| 37 | S&F in repair CP brass toilet paper holder, superior quality complete all as specified and directed. |
| 38 | S&F in repairs CP brass, soap dispenser, superior quality all as specified and directed. |
| 39 | S&F in repairs Health foucet including PVC pipe 1.50m long with brass nuts for EWC all as specified and directed |
| 40 | S&F in repairs PVC connection 15mm dia and 45cm long with 2 Nos PTMT nuts all as specified and directed |
| 41 | S&F in repair sheet glass shelf assembly consinsting of 5.5 mm thick sheet glass shelf 12 CM wide with CP bracket guard and railing 60 cm long all as specified and directed. |
| 42 | S&F in repairs vitreous china cream Countertop wash basin size 425 x 340 x 175 mm excluding taps, waste, chain, and plug but including neccessay fixing accessories all as Specified and directed. |
| 43 | S&F 40 mm Low density polyethylene (LDPE) pipes of pressure rating 6 kgf/sq. cm all as specified and directed. |
| 44 | Taking up or down steel tubing and connections 15 mm bore, including cleaning for refixing or removal all as specified and directed |
| 45 | S&F Female Brass Threaded Adaptor (FTA/ FBTA) for fixing of bib taps/ stop cock, mixer , shwoer all as specified and directed. |
| 46 | Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors all as specified and directed. |
| 47 | Cutting chases, pinning in and making good to facing on brick walls where required and pointing in cement mortar (1:3) to ends for concealed water tubing and making good, cutting n, exc. 10cm girth all as specified and directed. |
| 48 | S&F in repair, Concealed angle valve cock chromium plated brass fancy type bore 15mm all as Specified and directed. |
| 49 | S&F in reapir Brass CP mixer for mixing hot & cold water screwed down for iron pipe or upvc pipe and fixed all as specified and directed. |
| 50 | S&F in repairs Brass chromium plated shower rose 125mm size with or without swivel joints, any size, including fixing to steel pipe or union with shower arm all as specified and directed. |
| 51 | S&Fin repairs Vitreous China urinals, (back inlet type) of Jaquar including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing accessories or with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) Model No URS-WHT-13253O |
| 52 | S&F Urinal spreader of CP any colour for fixing with 15 mm dia pipe.(Minimum weight 60gms) all as specified and directed |
| 53 | S&F push valves (urinal) for 15 mm bore fancy type chromium plated long shank and cup concealed screwed for iron pipe or for brass ferrule all as specified and directed. |
| 54 | S&F PVC (SWR) 75mm bore bends any radius all as specified and directed. |
| 55 | S&F PVC (SWR) 110mm bore bends any radius all as specified and directed. |
| 56 | M&L in repairs PVC nahani trap withgrating 75mm dia outlet jointed to waste pipe fixed in cement concrete type B1 (1:2:4) all as specified and directed. |
| 57 | Dismantling ofPVC (SWR)pipe,any dia and any location all as specified and directed. |
| 58 | S&F PVC (SWR) 110mm bore pipes single socketed in any length with rubber ring joints fixed to wall all as specified and directed. |
| 59 | S&F PVC (SWR) 75mm bore pipes single socketed in any length with rubber ring joints fixed to wall all as specified and directed. |
| 60 | Excavation in trenches not exc 1.5 wide & not exc 1.5m in depth for foundation etc and getting out in Soft/loose soil all as specified and directed. |
| 61 | M&L Plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete all as specified and directed. |
| 62 | M&L brick work with sub class ‘B’ old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 all as specified and directed. |
| 63 | Returning filling in including spreading leveling watering and well ramming in layers not exc 25cm thickall as specified and directed. |
| 64 | Removing excavated material to a distance exc 15 Km away from the site all as specified and directed. |
| 65 | M&LReinforced cement concrete M-30 grade (using 20 mm graded crushed stone aggregate) (designmix) in Foundations, includingrafts, footings,foundationbeams; plinth beams; basesfor columns, etc.; basementslabs, under-reamed pilesand mass concrete all as specified and directed. |
| 66 | M&LReinforced cement concrete M-30 (using 20 mm graded crushed stone aggregate) (designmix) in Columns,pillars, piers,posts and struts all as specified and directed. |
| 67 | M&LReinforced cement concrete M-30 (using 20 mm graded crushed stone aggregate) (designmix) in Beams, cantilevers,bressummers,lintels over1.5m span all as specified and directed. |
| 68 | M&LReinforced cement concrete M-30 (using 20 mm graded crushed stone aggregate) (designmix) in Slabs supported on walls,beams and columns in floors,roofs, lanndings, balconies, canopies, deck slabs and inshelves and the like all as specified and directed. |
| 69 | Use & waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) offoundation and plinth beams;and similar work; vertical or tobatter all as specified and directed. |
| 70 | Use & waste formwork topillars,posts, struts, piers,columnsand stanchions all as specified and directed. |
| 71 | Use & waste formwork to sides and soffits offloor or roof beams, beam haunchings, girders, bressummers,lintels, cantilevers, shelves including sup- ports, overhangs,etc. also splays between floors and beams all as specified and directed. |
| 72 | Use & waste formwork to soffits of suspendedslabs such as roof slabs, floorslabs, landings and similar work;not exceeding 200mm thick(Horizontal or sloping) all as specified and directed. |
| 73 | M&L damp proof course In cement concrete 1:2:4, type B-0(40mm thick to horizontal or vertical surfaces including necessary formwork all as specified and directed. |
| 74 | M&L broken stone or boulder hardcore of gauge n exc. 63mm, deposited, spread and leveled in layers n exc. 15cm thick, watered and rammed to a true surface all as specified and directed. |
| 75 | M&L 100 mm thick PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in Sub base to floor and mass concrete. |
| 76 | M&L 75 mm thick PCC 1:3:6 type C2 (using 40 mm graded crushed stone aggregate) as in plinth protection/ footpath and finished surfaces even and smooth without using extra cement all as specified and directed. |
| 77 | M&LCeramic tiles lightshade 8-9 mm thick (square/rectangular) polished, area ofeach tilesexc 0.18sqm but not exc 0.38sqm, in floors etc. set andjointed in neat cement slurryand pointed in white orcoloured cement to match the shades of the tiles laid over 15 mm thick screed bed in CM 1:6 all as specified and directed. |
| 78 | M&LCeramic tiles lightshade 8-9 mm thick (square/rectangular) polished, area ofeach tilesexc 0.18sqm but not exc 0.38 sqm, in dado etc. set andjointed in neat cement slurryand pointed in white orcoloured cement to match the shades of the tiles laid over 10 mm thick screed bed in CM 1:4 all as specified and directed. |
| 79 | M&L Machine cut cudappah stoneslab 20-25mm thick over cementscreed base, laid and jointedwith grey cement slurry mixedwith pigment to match the shadeof the slab including rubbingand polishing all as specified and directed. |
| 80 | M&L granitestoneslab 18-20 mm thick laid over cementscreed base, laid and jointedwith grey cement slurry mixedwith pigment to match the shade of the slab including rubbingand polishing all as specified and directed. |
| 81 | Supply and fixing factory made uPVC door framemade of uPVC extruded sections having an overalldimension (extruded section profile) 48x40 mm(tolerance ± 1 mm), with wall thickness 2.0 mm(± 0.2 mm), corners of the door frame Jointed withgalvanized brackets and stainless steel screws, jointsmitred and Plastic welded. The hinge side vertical ofthe frames reinforced by galvanized M.S. tube of size19 X 19 mm and 1mm (± 0.1 mm) wall thickness and3 nos. stainless steel hinges fixed to the framecomplete all as specified by the manufacturer and asper directions of Engineer-in-charge |
| 82 | Providing and fixing factory made uPVC white colourcasement (Openable) Door made of extruded profilewilh wall thickness of 2.3mm ( + -0.2mm). Windowprofile with hollow section with mitlti chamber, frame (60mm x 58mm), sash (60mm x 78mm). T profile (Onevertical length in between two shutters) (60mm x74mm). Glazing bead (35mm x 20mm) will be miteredcut and fusion welded at all corners, includingdrilling ol holes for fixing hardware and drainage ofwater etc., making arrangement for fixing of hardware.EPDM gasket 1.2 + -0.2mm thick galvanized steelFrame (28mm x 21.5mm), sash (31mm x 27mm), Tprofile (27mm x 17mm) to be inserted in requiredprofile, frame will be fixed to the wall wilh 8mm x 100mm long fasteners. Hardware: [casement doorhandle made of zinc alloyed (white powder coated).Corner striker. Secondary Strikers. Cylinder. Doortransmission gear made of mild sleel with multi pointlocking system with strikes. 3D Hinges of zinc alloyed(white powder coated) [and 5mm thick glazing withselected quality glass.(Note: The unit rate quoted by contractor excludescost of glass and includes all other connectedaccessories. Net opening will be measured forpayment purpose.) |
| 83 | Supply and fixing factory made uPVC white colourThree track three panels sliding window with fly proofS.S wire mesh (Two nos. glazed & one no. wire meshpanels) upto 1.50m height made of (big series) frame116 x 45 mm & sash 46 x 62 mm both having wallthickness of 2.3 ± 0.2 mm and single glazing bead /double glazing bead of appropriate dimension. (Areaof window above 1.75 sqm) comprising of uPVC multi chambered frame, with inbuilt roller track and sashextruded profiles duly reinforced with 1.60 ± 0.2 mmthick galvanized mild steel section made from rollforming process of required length (shape & sizeaccording to uPVC profile), appropriate dimensionof uPVC extruded glazing beads and uPVC extrudedinterlocks, EPDM gasket, wool pile, zinc alloy (whitepowder coated) touch locks with hook, zinc alloy bodywith single nylon rollers (weight bearing capacity tobe 40 kg), G.I fasteners 100 x 8 mm size for fixingframe to finished wall and necessary stainless steelscrews etc. Profile of frame & sash shall be mitred cutand fusion welded at all corners, including drillingof holes for fixing hardware\"s and drainage of wateretc. After fixing frame the gap between frame andadjacent finished wall shall be filled with weatherproof silicon sealent over backer rod of required sizeand of approved quality, complete all as specified anddirected by Engineer-in-Charge. (Glass or wiremeshshall be paid separately)Note: For uPVC frame and sash extruded profilesminus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 84 | S&F curtainrails, mildsteel, chromium plated with fixing brackets,stops,rollers all as specified and directed. |
| 85 | M&L 10 mm thick rendering on fair faces of brick /concrete surfaces in CM (1:6), finished surfaces even and smooth (Without using extra cement ) all as specified and directed. |
| 86 | M&L 15mm thick rendering on fair faces of brick /concrete surfaces in CM (1:4), finished surfaces even and smooth (Without using extra cement ) all as specified and directed. |
| 87 | M&L 5 mm thick rendering on fair faces of RCCsurfaces in CM (1:4), finished surfaces even and smooth (Without using extra cement ) all as specified and directed. |
| 88 | M&L Oil based distemper on wall in two coat over a coat of primer including preparation of newly plastered surface all as specified and directed. |
| 89 | M&L three coats of white wash on wall including preparation of newly plastered surface all as specified and directed. |
| 90 | M&L three coats of white wash on ceiling including preparation of newly plastered surface all as specified and directed. |
| 91 | S&F5.5 mm thick Plain glass selcted quality as approved by Engr-in-Charge in squaresexc 0.50 Sqm in each pane three coats of white wash on wall including preparation of newly plastered surface all as specified and directed. |
| 92 | S&F5.5 mm thick Plain glass selcted quality as approved by Engr-in-Charge in squares n exc 0.50 Sqm in each paneall as specified and directed. |
| 93 | S&FSS wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks/wooden patti all as specified and directed. |
| 94 | S&F APP based polymeric membrane minimumweighing 3kg/sqm and minimum 3mm thickreinforced with polyster non woven fabric (wt. notless than 150 gms/sqm)laid on primed surfaceall as specified and directed. |
| 95 | M&L TMT bars 10mm dia and over cut to length bent to shape required including cranking and bending etc and binding with MS wire (annelaed) not less than 0.9mm dia or securing with clips all as specified and directed. |
| 96 | M&L Mild steel TMT bar bars 8 mm diain stirrups, spacers and binders including crancking, bending, placing & binding with MS wire (annealed) not less than 0.9 mm dia all as specified and directed. |
| 97 | Supply only liquid integral water proofing compound. |
| 98 | Taking down carefully copper/aluminum point wiring light/fan/sockets out let/power point complete (fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc. are to be measured separately) and/or drawing out from existing conduit/batten and making good disturbed surface of walls/floors/ceiling |
| 99 | M&L for Point wiring with 1.50 Sqmm single core PVC insulated, unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceilingand incuding provision of 1.50 Sqmm single core PVC insulated, unsheathed cable FRLSH, 1100 volts grade with multi stranded copper conductorgreen colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box/metal flush box with suitable modular or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer bothinternally and externally including provision of new 3 mm thick plastic laminated sheet top cover for housing the switches, socket outlets, fan regulators etc. with brass screws and brass washersand making goodthe disturbed surfaces as per existingfor one light point controlled by one switch. Note :- Switch, socket and fan regulators to be measured and paid for separately . PVC Conduit confirming to IS 9537 part I & III Note (All chases will be cut by chase cutter only) AMke of Cable - KEI/ Havells / Kalinga |
| 100 | All as per Srl item No.99 here in before but for socket outlet point 5 Amp on same board. |
| 101 | All as per Srl item No.99 here in before but for socket outletpoint 5 Amp on Independent board. |
| 102 | All as per Srl item No.99 here in before but with 4 sqmm cablefor 3 pin 15 Amps switch socket outlet (Power point) complete all as specified. |
| 103 | Supply and fixing modular switch 1 way 6A module 230/250 volt, AC supply,ISI Marked, with white cover plate with frame all as specified and directed. |
| 104 | S&F modular switch 1 way 16A module 230/250 volt, AC supply,ISI Marked, with white cover plate with frame all as specified and directed. |
| 105 | S&F modular sockets 6A, 5 pin combined 2 module 230/250 Volts,50 Hz , AC supply, ISI Marked, with white cover plate with frame all as specified and directed. |
| 106 | S&F modular sockets 6A/16A 2/3 pin combined 2 module 230/250 Volts,50 Hz , AC supply, ISI Marked, with white cover plate with frame all as specified and directed. |
| 107 | S&F ceiling rose surface bakelite 65x50mm, 3 terminal all as specified and directed. |
| 108 | S&F LED lights fitting 1x 20W, 220V, AC decorative box type, warm white / white type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose pre wired fixed to wallwith 2 nos PVC block of suitable size all spcifided and directed. |
| 109 | S&F round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size all as specified and directed. |
| 110 | S&F in repairs Slim design LED recessed square 2X 2,36 watt Warm/ white type flat panel PDC aluminium housing and PMMA diffuser all as directed and specified |
| 111 | S&F in repairs Exhaust fan 230 volts, 250mm, plastic body includingmaking all electric connection all as specified and as directed including cutting of hole on wall and making good disturbed surface of wall and outer wooden box for fan fix on wallincluding taking down old one all as specified and directed. |
| 112 | S&F in repairs LED security Buildinglight LED 45 Watt, pressure die cast aluminum housing, heat resistant glass, IP-65 protection, better optics for uniform distribtion complete with all accessories internally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of light all as specified and directed. |
| 113 | S&F in repairs MCB Distribution board, 240 volts single pole andneutral, double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 8 ways, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection, including taking down all as specified and directed. |
| 114 | S&F in repairs MCB DP, 240 Volts, 40 Amps, 10 kA rupturing capacity \"C\" series all as specified and directed |
| 115 | S&F in repairs MCB, single pole 240 volts 6 to 32 Amps capacity fixed in DB\"sall as specified and directed. |
| 116 | S&F Ceiling fan complete with blades, down rods,electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDCmaking all electric connection. huck and suitable size rod for hanging ceiling fan all as specified and as directed |
| 117 | S&F hot water Geysers of 25 ltrs capacity 5 star ratedvertical type includng fixing of bolts, nuts grouted into the wall, and necessary cement work, making good of disturbed surface of wall, giving electric, hot and cold water pipe, tab etc and water connection and testing after installation all as specified and directed. |
| 118 | Supply & laying galvanized steel tubing, medium grade laid in trenches/floor/wall and joined including necessary fittings such as bends, elbow, tees, sockets, etc for 15mm dia pipe all as specified and directed.. |
| 119 | M&L in repairs Sub main wiring with two run of single core 6 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia concealed on wall/ceiling in PVC conduit, medium gradeISI markedwith all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall along with one run of6 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion including taking down old wiring all as specified and directed. Note: (i) Two runs of 4 sqmm and one run of6 sqmm cable and one run of PVC conduitshall be measured as one RM. (ii)Cutting of chases in the wall of appropriate size shall be carried out with electric cutter machine . (iii) Necessary plastering in the disturbed surface of wall and distempering /white washing to match the existing colour shall be included in the unit rate quoted. |
| 120 | M&L in repairs Sub main wiring with two run single core 4 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia Cassing cappingISI markedwith all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of4 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion inculding taking down old wiring all as specified and directed.Note: (i) Two runs of 6 sqmm and one run of6 sqmm cable and one run of PVC conduitshall be measured as one RM. |
| 121 | Supplying, laying, commissioning & testing LT underground cables 10 Sqmm X 3 Core, 1100 Volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi-stranded aluminium conductor all as per IS 7098 (Part -1) laid including suitable sizetrenches, ducts, drawn through pipes or fixed on poles, as and when required all as specified and directed.. Note : Rate inclusive of aluminium Lugs and furrowl used in cable connection. |
| 122 | M&L for earthing complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers, galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm C/c both ways andone handle for lifting made out of 8 mm dia TMTbar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy