| 1 | To attend complaint for Comprehensive/preventive maintenance of Split & Window ACs / Desert Coolers/ Water cooler / Refrigerator /Deep Freezer of various capacitiesby carrying out periodical maintenance incl cleaning, lubrication, filling refrigerant gas etc, including chemical, anti moisture injection required for cleaning condenser/ cooling coils complete and make serviceable the eqpt complete all as specified and directed. |
| 2 | Supply & Fix in repair sealed compressor unit of any make any type for water cooler of cap 40 Ltrs/hr by cutting of suction and discharge lines and unscrewing the foundation nuts & bolts etc, and fixing with new sealed compressor unit by tightening the foundation nuts and bolts and connecting suction and discharge line with gas welding work etc and checking the leakage in the system and charging the gas R-22 / R-134 upto required pressure and tightening foundation nuts & bolts etc complete all as specified and directed. |
| 3 | All as per Srl Item No. 2.00 here in before but for water cooler of capacity 60 Ltrs/hr . |
| 4 | All as per Srl Item No. 2.00here in before butfor water cooler of capacity 150 Ltrs/hr . |
| 5 | Supply & Fix in repair potential relay box type for water cooler of any capacity complete all as specified and directed. |
| 6 | Supply & Fix in repair relay current type, for water cooler of any capacity complete all as specified and directed. |
| 7 | Supply & Fix in repair rubber hose pipe of 25mm bore with clips for outlet tray of water cooler approximately 1.5 Mtr long as per sample complete all as specified and directed. |
| 8 | Supply & Fix in repair Over load protector assembly complete all as specified and directed. |
| 9 | Supply & Fix in repair float valve assembly suitable for 15mm bore of PVC rigid type complete with ball, fixed to water cooler with threaded GI/PVC nipple washer, check nut etc complete all as specified and directed. |
| 10 | Supply & Fix in repair PVC connection rigid type 450mm long 15mm bore, with adopter at both ends complete all as specified and directed . |
| 11 | Material & Labour in replacement of old condenser of capacity 36 microfaradfins type with new, forced air-cooled including necessary brazing work for water cooler of any capacity including testing for leakage complete all as specified and directed. |
| 12 | Supply and fixing in repair fan motor of1/6 HP capacity water cooler complete all specified and directed. |
| 13 | Supply and fixing in repair push type self closing tap 15mm dia brass chromium plated for water cooler complete with all accessories washers, rubber packing etc complete all as specified and directed. |
| 14 | Supply & Fix in repair thermostat suitable for water coolers of cap 10°C to 30°C complete all as specified and directed. |
| 15 | Supply & Fix in repair steel tray alongwith rubber gasket, waste coupler and GI elbow with check nut of 32 mm dia including necessary brazing work suitable for single tapwater coolerof 40/80 litre capacity complete all as specified and directed. |
| 16 | All as per Srl Item No. 15.00here in before but for double tap water cooler of capacity 60/120 litre . |
| 17 | Material & Labour for making the system leak proof and charging of gas R 22/ R-134as required in water cooler of capacity 40/80 Ltr including replacement of drier and capillary tube and testing on load complete all as specified and directed. |
| 18 | Material & Labour for making the system leak proof and charging of gas R 22/ R-134 as required in water cooler of capacity 60/120 Ltr, 150/ 150 Ltr including replacement of drier and capillary tube and testing on load complete all as specified and directed. |
| 19 | Material & Labour for dismantling of water cooler of any capacity and taking out complete internal assembly ie. inner tank, inlet and outlet connection etc and de-scaling with chemical agent including cleaning and washing and reassembling with same position and making the tank leak proof by necessary brazing/welding work with gasket etc complete all as specified and directed. |
| 20 | Supply & Fix in repair of water cooler inner tank made of stainless steel as per existing capacity (60/80Ltrs) & size with necessary gaskets complete set with drilling work fixing with nut,bolts & washer etc complete all as specified and directed. |
| 21 | Supply and fixing in repair PVC fan blade of 250/300mm for water cooler complete all as specified and directed. |
| 22 | Material & Labour for repairing of the water cooler body front side by cutting the worn out stainless steel sheet and fixing new stainless steel sheet of 20 SWG cut inshape and fixed to frame with suitable fixing arrangement including welding/brazing complete all as specified and directed. |
| 23 | Supply and fixing runningcapacitor 20 mfd capacity for water cooler complete all as specified and directed. |
| 24 | Supply and fixing running capacitor 10 mfd capacity for water cooler complete all as specified and directed. |
| 25 | Supply & Fix in repair sealed compressor unit for any make and any type ofAir Conditioner, window/Split type, 1.5 ton capacity, by cutting of suction and discharge lines, unscrewing the foundation nuts & bolts etc, and fixing of new sealed compressorunit by connecting suction and discharge lines with gas welding / brazing work including checking the leakeage in the system and charging the gas R -22/ R-410 upto required pressure and tightening foundation nuts & bolts etc complete all as specified and directed. |
| 26 | All as per Srl Item No. 25.00but for air conditioner window/split type, 2 ton capacity . |
| 27 | Supply & Fix in repair Electric blower Motor of capacity 1/8 HP for Air conditioner window type/split type 1.5 ton/02 ton capacity complete all as specified and directed. |
| 28 | Supply & Fix in repair Thermostat of capacity 16°C - 30°C with regulating knob for AC window/split type, working on SP, 230V, AC complete all as specified and directed. |
| 29 | Supply & Fix in repair evaporating coil assembly with copper tubefor window type AC of capacity 1.5 toncomplete all as specified and directed. |
| 30 | Supply & Fix in repair condensingcoil assembly with copper tubefor window type AC of capacity 2.00 toncomplete all as specified and directed. |
| 31 | Supply & Fix in repair copper pencil strainer of requisite length of dia 6.25mm (min) complete all as specified and directed. |
| 32 | Supply & Fix in repairPVC blade for blower motor for window type AC/Split AC of Capcity 1.5 TR/ 02 TR complete all as specified and directed. |
| 33 | Supply & Fix in repair of PCB circuit with remote control for air conditionerof capacity 1.5/2 ton complete all as specified and directed . |
| 34 | Supply & Fix in repair starting capacitor 40 mfd, working voltage 275 volts, 50 Hz, AC suitable for window type room AC of capacity 1.5 TR/2.00TR & Water coolercap 40, 60 ltr complete all as specified and directed. |
| 35 | All as per Srl Item No. 34.00 here in before but for 60/80 mfd. |
| 36 | Supply & Fix in repair running capacitor 36 mfd 440 volts, AC 50 Hz, type SMRC suitable for room AC (Capacity 1.5 TR / 2.00 TR) complete all as specified and directed. |
| 37 | All as per Srl Item No. 36.00 here in before but 45 mfd . |
| 38 | Supply & Fix in repair Metal clad plug top, 3 pin , 20 amps, 230 volts complete all as specified and directed. |
| 39 | Supply & Fix in repair single pole and neutral enclosure with metal clad plug and socket 20 Amps and one single pole MCB 25 Amps complete all as specified and directed . |
| 40 | Supply & Fix in repair PVC front grill suitable for window type room AC of 1.5 ton/ 2 ton capacity complete all as specified and directed. |
| 41 | Supply & Fix in repair three core, 2.5 Sqmmcopper wire PVCinsulated unsheathed,multistranddrawn through the PVCconduit/ PVC flexible pipe complete with suitable size of copper lugs etc complete all as specified and directed. |
| 42 | All as per Srl Item No. 41.00 here in before but of size 4 Sqmm . |
| 43 | Supply & Fix in repair MCB single pole, 16 to 25 amps rating, 240 volts, \"B\" series, 10 KA breaking capacity & connection with aluminium/copper lugs complete all as specified and directed. |
| 44 | All as per Srl Item No. 43.00 but for 40 Apms rating. |
| 45 | Supply & Fix in repair MCB, 32 amps rating, single pole & neutral, 240 volts, \"B\" series, 10 KA breaking capacity & connection with aluminium/ copper lugs complete all as specified and directed. |
| 46 | All as per Srl Item No. 45.00 but for 40 amps rating. |
| 47 | Material & Labour for Re-charging of refrigerant gas (R-22) for window type AC /split Type AC of Cap 1.5 Ton after vaccuming dehydration, leak testing of the system as per standard practice, testing for proper cooling effects and satisfactory performance complete all as specified and directed. |
| 48 | All as per Srl Item No. 47.00 but for Window AC/Split AC 2 Ton capacity. |
| 49 | Supply and fixing in repair relay, box type, for Air Conditioner window/split type of cap 1.5 Ton complete all as specified and directed . |
| 50 | Supply and fixing in repair selector switch rotary typefor AC, 1.5 ton/02 toncapacitycomplete all as specified and directed. |
| 51 | Supply & Fix in repair air filter for split type Air conditioner of 1.5/2 ton capacity complete all as specified and directed . |
| 52 | Supply & Fix in repair air filter washable of Nilon mesh suitable for window type air conditioner of 1.5/2 ton capacity complete all as specified and directed . |
| 53 | Supply & Fix in repair toggle switch for AC 1.5/2 ton cap complete all as specified and directed. |
| 54 | Supply & Fix in repair sensor remote switch for AC 1.5/2 ton cap complete all as specified and directed. |
| 55 | Taking out the old/unserviceable heating/cooling unit from the machine of Air conditioner of 1.5/2 ton capacity and Supply & Fix reversable unit (Hot and Cold) complete all as specified and directed. |
| 56 | Supply & Fix copper pipe with insulation of size 1/2\", 1/4\" for Split AC of 1.5/2 ton capacity complete all as specified and directed. |
| 57 | All as item No 56.00 above but for size 3/8\", 5/8\" . |
| 58 | Supply and fix stand set (GI bracket of suitable size)for outdoor AC unit of capacity 1.5/2 ton capacity complete all as specified and directed. |
| 59 | Material & Labour for disconnecting, dismantling of existing split/ window type AC 1.5 /2 TR & refixing the same at new location including gas charging complete all as specified and directed. |
| 60 | Supply & Fix in repair Vertical / submersible pump 100 watt capacity operating on Single Phase, 230 Volts, 50 HZ, AC of any type of Desert Cooler, complete all as specified and directed . |
| 61 | Supply & Fix in repair Desert cooler fan motor of any capacity as per existing operating on Single Phase 230 Volts, 50 HZ, ACwith fan blade and mounting Kit complete all as specified and directed. |
| 62 | Supply & Fix in repair fan regulator with selector switch suitable for 3 Speed fan motor fordesert cooler of capacity 40/60 litre, Single phase, 230V, ACcomplete all as specified and directed. |
| 63 | Supply & Fix in repair forPVC pipe 15mm bore of length 450mm standard quality for desert cooler complete with fixing arrangement complete all as specified and directed. |
| 64 | Material & Labour forwood wool pad/ Khas root pad of desert cooler as approved by GEof 3000/4000 CUM/Hour capacity ofsuitable size including taking down old unserviceable pads of any type complete all as specified and directed . |
| 65 | Supply & Fix in repair 1.5 Sqmm, 3 core copper wire PVCinsulated sheathed drawn through the PVCconduit/ PVC flexible pipe complete with suitable size of copper lugs etc complete all as specified and directed . |
| 66 | Supply & Fix in repair elbows and water hub suitable for 15 mm dia PVC flexible pipe of desert cooler complete all as specified and directed. |
| 67 | Supply & Fix in repair compressor refrigerator of 165/175/180/190/230 ltrs capacity and fixing new sealed compressor unit, brazing work, making the system leak proof, vacuumising and charging with gas R-134 and testing complete all as specified and directed . |
| 68 | All as per Srl Item No. 69.00 here in before but for refrigerator of 260/280/286/ 290 ltrs capacity . |
| 69 | All as per Srl Item No. 69.00 here in before but for refrigerator of 310/315/320 ltrs capacity . |
| 70 | Supply and Fixingin repair relay box type for refrigerator of capacity 165/190/260/280/315 litre complete all as specified and directed. |
| 71 | Supply and fixing in repair of thermostatic auto defrost switch with knob for refrigerator of capacity 165/190/260/280/315 litre complete all as specified and directed. |
| 72 | Material & Labour for removing the burnt/defective sealed compressor unit of any make from any type ofdeep freezer unscrewing the foundation nuts & bolts etc, supply and fixing of new sealed compressor unit of capacity 320/400 litre relay box by connecting suction and discharge lines with gas welding/brazing work etc.and tightening foundation nuts & bolts etc and charging of gas upto the required pressure complete all as specified and directed. |
| 73 | Material & Labour for charging refrigerant gas R-22/R-134 in Deep freezer of cap 200/250/320/400 ltrs complete all as specified and directed. |
| 74 | Supply & Fix in repair Vegetable tray as per sample and suitable for refrigeratorof capacity 165/220/315 Ltr complete all as specified and directed . |
| 75 | Supply & Fix Evaporator suitable for Voltas/Godrej refrigerators capacityfixed in repairs for 165/290/315 ltr capacity complete all as specified and directed . |
| 76 | Material & Labour for replacement of over load starting relay kit suitable for 165/280/315 Ltrs capacity refrigerators of any make and testing complete all as specified and directed . |
| 77 | Material & Labour for replacement of Fan motor of capacity 12 volt, 5 watt, 240 volts,SP for frost free freeze complete all as specified and directed . |
| 78 | Material & Labour for charging refrigerant gas R-22/R-134 in refrigerator of cap 165/286/310 ltrscomplete all as specified and directed . |
| 79 | Material & Labour for replacement of electronic chip (PCB) including defrost timer,biometal for refrigerator of capacity 165/180 ltrs complete all as specified and directed . |
| 80 | Supply & Fix in repair of freezer to refrigerator of 165/190/260/315 litres capacity complete all as specified and directed.. |
| 81 | Supply and fixing for replacement capacitor 4 mfd complete all as specified and directed. |
| 82 | Supply and fixing Plug top, 3 pin, 15 Amp, SP, 230V, fixed in repairs complete all as specified and directed . |
| 83 | Material & Labour for removing the blockage in evaporating coil of Deep Freezer of capacity 320/400 litre complete all as specified and directed . |
| 84 | Supply and fixing in repair Plug top, 3 pin, 05 Amp, SP, 230V, fixed in repairs complete all as specified and directed . |
| 85 | Taking down of defective/burnt stablizer from various locations under GE Utility Ambala of capacity 1 to 5 KVA, single phase and Re-installation ofVoltage stablizer after repair of the defective parts and winding of burnt transformer alongwith replacement with new parts/ winding and testing complete all as specified and directed. (Note :- New parts to be used in repair of replacement shall be measured and paid seperately as supply only item as follows.) |
| 86 | Supply only relay 24 Volts 250 Ohms complete all as specified and directed. |
| 87 | Supply only Condensor of existing capacity complete all as specified and directed. |
| 88 | Supply only Transistor of existing capacity complete all as specified and directed. |
| 89 | Supply only Circuit Card of existing capacity complete all as specified and directed. |
| 90 | Supply only Ceramic IC of existing capacity complete all as specified and directed. |
| 91 | Supply only Transformer winding (copper) complete all as specified and directed. |
| 92 | Supply only Mosfet of existing capacity complete all as specified and directed. |
| 93 | Supply only Volt meter as per existing complete all as specified and directed. |
| 94 | Supply only Indicator lamp (red/green) complete all as specified and directed. |
| 95 | Supply only Terminal strip complete all as specified and directed. |
| 96 | Supply only Push button 03 Nos. (Per set) complete all as specified and directed. |
| 97 | Material & Labour in replacement of angle iron stand for desert cooler made out of angle iron40x40x5mm of required size with four legs and set of four angle for desert cooler support, duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 98 | Material & Labour for one coat of spray painting with synthetic enamel paint to Desert Cooler / refrigerator / Water Cooler any cap including anti-corrosive black paint on compressor, condenser coil Scratching out the existing paint with sand paper and filling up the scratches with putty complete all as specified and directed. |
| 99 | Material & Labour for replacement of 22 guage MS sheet of Desert Cooler bottom tank including nut, bolts, screws, welding if required, painting with two coats of synthetic enamel grey paint over a coat of red oxide primer complete all as specified and directed.. |
| 100 | Supply and fixing outdoor unit Cap 1.5 Ton suitable for/compatible with Split AC indoor units of capacity 1.5 ton including PCB for automatic control with copper condensor coil, condenser fan motor, fan blades,compressor,capacitor ,relay,connector etc with all other parts of outdoor unit (complete set up) incl refrigerant R-407/22 as required at site including taking down existing complete all as specified and directed. Make-Voltas/ LG/ Bluestar / Hitachi |
| 101 | Supply and Fix in repair condensing fan motor/ outdoor unit motor as per existingsuitable for 1.5/2.0 Ton split type AC complete all as specified and directed. |
| 102 | Supply and Fix in repair condensing fan motoras per existingsuitable for 1.5/2.0 window type AC complete all as specified and directed. |
| 103 | Supply and fixing Indoor unit as per existing suitable for/compatible with split AC outdoor unit of capacity 1.5 Ton with evaporator coil/cooling coil, LCD display, PCB card, multi fan speeds, blower motor,auto air swing motor, filter,on-off timer ,inlet & outlet copper pipe, etc. with all other parts of indoor unitincluding remote control hand set and taking down existing complete all as specified and directed. Make-Voltas/LG/Bluestar / Hitachi |
| 104 | Note:-For the items for which specifications not mentioned any where in the DCS, the BIS specifications shall be followed. |
| 105 | Note:-Amount of credit ofRs. 145639.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in pdf form which will be deducted offline while acceptance of tender. |