| 1 | Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed. |
| 2 | Clearing compound premises of shurbs, plants, jungles etc.by cutting and removing as directed (Specific permission ofEngineer-in-Charge prior to execution will be necessary).(Payment to be made on area cleared) |
| 3 | Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed. |
| 4 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. |
| 5 | a) In ground floor including roof. |
| 6 | Cutting chase upto 125 x 150 mm. and subsequent mending of damages. |
| 7 | (a) in brick wall [Cement-3.6 Kg/Mtr] |
| 8 | Removal of rubbish, earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge |
| 9 | Labour for Chipping of concrete surface before taking upPlastering work. |
| 10 | Cleaning the concrete surface by removing dirt and debris, marking defective locations and removing loose concrete by careful stripping untill hard surface is exposed, cutting the concrete to regular shape, wire brushing the exposed surface and removing debris from site complete as per direction of the Engineer - in - Charge. |
| 11 | Applying epoxy based reactive joining agent for joining the old concrete with fresh concrete to be applied within manufacturer\"s specified time as per manufacturers specification. (0.4 Kg / m² of concrete surface). |
| 12 | Note: Applicable only when the full diameter of reinforcement steel is exposed. |
| 13 | Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturer\"s specified rate) for concrete of various grades. |
| 14 | Supplying and laying Polythene Sheet (150gm / sq.m.) overdamp proof course or below flooring or roof terracing or infoundation or in foundation trenches. |
| 15 | Cement concrete (1:1.5:3) with graded stone chips 5.6 mm size with hexagonal square mesh wire netting, I.R.C. fabric mesh or X.P. M. fitted and fixed after tying the existing reinforcement on concrete without distributing the same and with proper scarping and cleaning the reinforcement and disturbed concrete with wire brush etc. after applying a coat of cement including the cost of wire netting I.R.C or X. P. M. & cost of all handling and scaffolding complete as per direction of Engineer-in -charge. |
| 16 | c) 37.5mm thick |
| 17 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] |
| 18 | (i) With 1:6 cement mortar |
| 19 | (b) 20 mm thick plaster |
| 20 | (ii) With 1:4 cement mortar |
| 21 | (c) 10 mm thick plaster |
| 22 | Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc.NOTE:Cement 0.152 cu.m per100 sq.m. |
| 23 | (a) Cleaning the walls and ceiling by scraping, sand papering and smoothening down the surface including putting. |
| 24 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. |
| 25 | A) UPVC Pipes: |
| 26 | (ii) 110 mm. Dia. |
| 27 | B) UPVC Fittings: |
| 28 | a) Plain Tee |
| 29 | (ii) 110 mm. Dia. |
| 30 | c) Bend 87.5 degree |
| 31 | (ii) 110 mm. Dia. |
| 32 | d) Shoe |
| 33 | (ii) 110 mm. Dia. |
| 34 | Brick work with 1st class bricks in cement mortar (1:6) |
| 35 | (b) In superstructure, ground floor |
| 36 | Making one set of scaffolding only for replacing glass panels, painting, uprooting plant and another repairing works of building and S&P works for external works only with 10 cm. dia bamboo as main posts at the rate of 1 metre centre to centre and 7.5 cm. dia bamboo ties @ 0.75 metre apart fitting and fixing with necessary coir, nails etc. as per direction of the Engineer-incharge. |
| 37 | This item should be executed only after prior approval of the Engineer-incharge). Firstly, one number to be paid and then labour rate for shifting up to further nineteenth (19) times @ 10% each time to be considered. If necessary further after twenty times of total use, another one number new and labourrate for shifting to be considered accordingly. |
| 38 | a) 3.90 metre height |
| 39 | Shifting Charge |
| 40 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) |
| 41 | (When the height of a particular floor is more than 4 m the equivalent floor height shall be taken as 4 m and extra for works beyond the initial 4 m ht. shall be allowed under 12 (e) for every 4 m or part thereof) |
| 42 | (f) 25 mm to 30 mm shuttering without staging in foundation |
| 43 | Scraping of moss, blisters etc.thoroughly from exterior surface of walls necessitating the use of scraper, wire brush etc. (Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge) |
| 44 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of theEIC. |
| 45 | In Ground Floor: |
| 46 | (b) Two Coats |
| 47 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. |
| 48 | In Ground floor (Two Coat) |
| 49 | a) Normal Acrylic Emulsion |
| 50 | Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer\"s specification) including cleaning and smoothning of surface.Two Coats |
| 51 | Cleaning and removing paint mark from glass pane with spirit and removing strains etc. |
| 52 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. |
| 53 | (a) For works in foundation and upto roof of ground floor/upto 4 m |
| 54 | (i) Tor steel/Mild Steel |
| 55 | I. SAIL/ TATA/RINL |
| 56 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. |
| 57 | (iv) With local hard blackstone variety chips (crusher broken) |
| 58 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)(a) For Exposed WorkPVC Pipes (Dia) |
| 59 | 15 mm |
| 60 | 20 mm |
| 61 | 25 mm |
| 62 | Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 35 kg per sq. cm. (for gas line only). |
| 63 | (vii) 25 mm dia |
| 64 | (viii) 20 mm dia |
| 65 | Supplying, fitting and fixing bib cock or stop cock. |
| 66 | (f) (i) Polythene Bib Cock / Stop Cock (HD) with metal inlet (EMCO / ATLAS or equivalent)15 mm |
| 67 | Supplying, fitting and fixing shower of approved brand and make. |
| 68 | (g) PTMT overhead shower ( Prayag or equivalent) |
| 69 | (i) 75 mm round |
| 70 | Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer |
| 71 | (a) 500 litre capacity |
| 72 | Labour for hoisting plastic water storage tank. |
| 73 | (i) Upto 1500 litre capacity. |
| 74 | (a) Upto 1st story from G.L. |
| 75 | Labour for punching hole in plastic water storage tank upto 50 mm dia. |
| 76 | Cleaning and disinfecting upto 2000 litre Water Tank including masonry reservoir. |
| 77 | Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. |
| 78 | (ii) 450 mm long |
| 79 | Supplying,fitting and fixing approved brand 32 mm dia. P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps. |
| 80 | (i) 600 mm long |
| 81 | Cleaning wash basin/ sink with acid. |
| 82 | Cleaning E.P. or Anglo-Indian W.C. with acid. |
| 83 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. |
| 84 | In ground floor including roof. |
| 85 | (a) upto 150 mm. thick |
| 86 | (a) M.S.or W.I. Ornamental grill of approved design jointscontinuously welded with M.S, W.I. Flats and bars of windows,railing etc. fitted and fixed with necessary screws and lugs in ground floor. |
| 87 | (Add extra @ 1% for each addl. floor upto 4th floor and @ 1.25% for each addl. floor above 4th floor) |
| 88 | (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. |
| 89 | Removing old paint from blistered painted surface of steel or other metal by chipping including scraping and cleaning and exposing the original surface. |
| 90 | (a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 91 | (b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 92 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : |
| 93 | (a) On timber or plastered surface :With super gloss (hi-gloss) - |
| 94 | (iv) Two coats (with any shade except white) |
| 95 | (b) On steel or other metal surface : |
| 96 | With super gloss (hi-gloss) - |
| 97 | (iv) Two coats (with any shade except white) |
| 98 | Add GST 18 % ( CGST 9 % + SGST 9 %) |
| 99 | Add Cess 1 % |