Power Government Departments Closing in 0 days TDR #49297831

Tender For Biennial Electrical Maintenance Works At Captive Power Plant, Hwp, Manuguru During The Period 2025-27.

Issued by Government Departments · aswapuram, Telangana
Tender Value
37.65 Lakhs
Estimated cost
Bid Submission
31 May 2025
0 days left
EMD
75300
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
aswapuram → Telangana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Biennial Electrical Maintenance Works At Captive Power Plant, Hwp, Manuguru During The Period 2025-27.

BOQ

Name of Work: Biennial Electrical Maintenance Works at Captive Power Plant, HWP, Manuguru during the period 2025-27.
Sl. No. Item Description
1Preventive Maintenance of circuit breakers of following voltage level and type:
2220kV SF6
333 kV VCB
411 kV VCB
5415V ACB
6Preventive maintenance of 220kV Isolators
7Preventive maintenance of 220kV switchyard bay marshalling box
8Preventive maintenance of switchgear panel of following voltage level:
933kV
1011kV
11415V
12Preventive Maintenance of transformers of following rating:
13220/33kV, 40MVA
1433/11kV, 40MVA
1533/6.6kV, 16MVA
1611/6.6kV, 8MVA
17Below 8MVA
18Oil topup in transformers of following rating:
19Above 8MVA
208MVA and below
21Replacement/Drying of Silica Gel of transformer
22Arresting of oil leak from transformer of following rating:
23220/33kV, 40MVA
2433/11kV, 40MVA
2533/6.6kV, 16MVA
2611/6.6kV, 8MVA
27Below 8MVA
28Transformer oil sample collection and testing(for BDV) as per relevant Indian standard. BDV kit will be provided by department
29Disconnection of power cables from transformer(rated 40 MVA) terminals(after opening terminal box cover) for the purpose of measuring of IR value and subsequent connection and closing of terminal boxes. Measurement of IR value covered in other item.
30Disconnection of ground connection from transformer(rated 40 MVA) neutral terminals for the purpose of measuring of IR value and subsequent connection. Removal and reconnection of any other ground connections in the circuit are also covered in this item. Measurement of IR value covered in other item.
31Disconnection of power cables from transformer(rated between 8MVA and 40MVA) terminals(after opening terminal box cover)/bus bar terminals for the purpose of measuring of IR value and subsequent connection and closing of terminal boxes. Measurement of IR value covered in other item
32Disconnection of ground connections from transformer(rated between 8MVA and 40 MVA) neutral terminals for the purpose of measuring of IR value and subsequent connection. Removal and reconnection of any other ground connections in the circuit are also covered in this item. Measurement of IR value covered in other item.
33Disconnection of power cables from transformer(rated 8 MVA and less) terminals(after opening terminal box cover) for the purpose of measuring of IR value and subsequent connection and closing of terminal boxes. Measurement of IR value covered in other item.
34Disconnection of ground connections from transformer(rated 8MVA and less) neutral terminals for the purpose of measuring of IR value and subsequent connection. Removal and reconnection of any other ground connections in the circuit are also covered in this item. Measurement of IR value covered in other item.
35Removal of existing Oil Temperature indicator/Winding temperature indicator of transformer and replacing it with spare by proper mounting. Connection and disconnection of indicator terminals from marshalling box is in the scope of contractor
36Measurement of Insulation resistance value/ Polarisation index value of transformer winding/power cable/circuit breaker/bus bar/motor etc.
37Measurement of dielectric disspitation factor/Capacitance value of insulations of 220kV CT/PT/transformer/OIP bushing
38Troubleshooting of control/protective/power circuits of 220kV circuit breaker/ 220kV isolator/ 220/33kV 40MVA transformer/220kV CT/220kV PT etc.
39Troubleshooting of control/protective/power circuits of 33kV switchgear/33kV breakers/33kV-11kV-6.6kV voltage level transformers etc.
40Troubleshooting of control/protective/power circuits of 6.6kV-415V voltage level transformer/6.6kV motor etc.
41Troubleshooting of control/protective/power circuits of 415V circuit breaker/ 415V transformer/ 415V switchgear/ 415V motor etc.
42Troubleshooting of control/protective circuits of 220V DC/48V/24V DC system
43Installing semaphore switch/ Annunciator/ Ammeter/ Voltmeter/ Energy meter/ Synchronising selector switch/Protective relay/Selector switch/Indication lamp/contactor/overload/MCB/fuse holder/TPN switch etc by cutting the panel door to suitable size, proper mounting as per instructions of EIC and proper terminations of wires with lugs
44Replacement of fuse holder/MCB/semaphore switch/ Annunciator/ Ammeter/ Voltmeter/ Energy meter/ Synchronising selector switch/Protective relay/Selector switch/Indication lamp/contactor/overload/TPN switch etc with spare and proper terminations of wires same as before
45Improvement of IR value to satisfactory value(as directed by EIC) of 33kV outgoing cubicle by hot air blowing/ heating with luminaires etc.
46Improvement of IR value of 415V motor to satisfactory value(as directed by EIC) by hot air blowing in terminal box/ heating with luminaires etc.
47Preventive Maintenance of HT motor
48Condition monitoring of HT motor
49Improvement of IR value of 6.6kV motor to satisfactory value(as directed by EIC) by hot air blowing in terminal box/ heating with lumiaires etc.
50Preventive Maintenance of LT motor and its module
51Condition monitoring of LT motor
52Temporary power supply connection / disconnection at different location (material collection from plant store and safe return to plant in contractor scope)
53Condition monitoring of LT module
54Shifting of CTs/PTs/LT motors/Control transformers/testing kits etc. from DPS store/E-U store to site/site to store when required
55Removal of connection of 220KV overhead conductors from OIP bushings for testing of bushings and re-termination after completion of testing
56Pre-monsoon checks of transformers as per checklist
57Disconnection of cables from motors/overhead lines/TBs etc. for troubleshooting etc. and reconnecting after completion of troubleshooting
58Supply of paint and painting of the surface of cable tray/panel/motor/exhaust fan etc. Minimum quantity of synthetic enamel smoke grey paint to be supplied:60 litres
59Preparation of various documents in system as per technical specifications
60Supply of 1.5V AA cells as and when required, Make: Duracell
61Supply of 9V cells as and when required, Make: Duracell
62Puncture Repair of cargo loader tyre as and when required as per technical specifications
63Installation of quarter turn locks(Zinc die casting body, steel cam, chrome plating) including supply of lock with key for electrical panel of following dimensions:Panel cut-out:22mm dia.(approx.) as per sample. Grip length upto 100mm as per sample.
64De-dusting of modules/panels, Segregation of spares/scrap in section stores etc.
65Fabrication, painting(one coat each of red oxide and synthetic enamel grey) of support angles/transformer control cabinet canopy/cable tray canopy/neutral grounding resistor enclosure etc. including supply, cutting, welding of MS sheet/plate/angle of required thickness, required GI nuts, bolts, plain and spring washers and fixing at site as per technical specifications. Supply of red oxide and synthetic enamel grey paint is also in the scope of contractor
66Supply of magnetic oil gauge suitable for 33kV/6.6kV 10/16 MVA transformer as per technical specifications. Make: Sukrut/Yogya/Atvus/Viat
67Replacement of supplied magnetic oil gauge as per item Sl.No.47 as per technical specifications
68Supply and replacement of control transformer in HV testing kit. Specification of transformer: 230V/115V,50Hz, 300VA. Double winding type, Chassis mount

AI Tender Summary

OUR REF NO 49297831
AUTHORITY Government Departments
TENDER VALUE 37.65 Lakhs
LAST DATE 31-05-2025
Authority
Authority Name Heavey Water Board
Work Description Biennial Electrical Maintenance Works At Captive Power Plant, Hwp, Manuguru During The Period 2025-27.
Basic Detail
Tender No HWPM/EU/AMC/2025/01/NIT , Dt.15.05.2025
Bidding Type Tender
Location
City aswapuram
State Telangana
Key Dates
Publish Date 23 May 2025
Submission Date 31 May 2025
Open Date 06 Jun 2025
Finance
Tender Value 37.65 Lakhs
Tender Fee Ref. Documents
EMD 75300
Exemption Not Available
Document List
df8495b3-4af2-4d90-bb59-412eb3ab67d7.html
BOQ_905138.xls
TechnicalSpecifications.pdf
Tendernotice_1.pdf
Formstobesubmittedbybidde_1.pdf
GCCMaintenanceWorks2023.pdf
Safetyguidelines.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 23, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
May 31, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jun 06, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

df8495b3-4af2-4d90-bb59-412eb3ab67d7.html

xls

BOQ_905138.xls

pdf

TechnicalSpecifications.pdf

pdf

Tendernotice_1.pdf

pdf

Formstobesubmittedbybidde_1.pdf

pdf

GCCMaintenanceWorks2023.pdf

pdf

Safetyguidelines.pdf