| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard dense soil |
| 2 | Cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in foundations, filling and mass concrete |
| 3 | M&L for TMT steel bars 10mm dia and over, cut to length bent to shape required as in reinforce ment to lintels all as spcd and as directed |
| 4 | All as per item No03 here-in-before but 6mm to 8mm dia |
| 5 | All as per item No 03 here-in-before but 5mm dia and over upto and including 10mm dia in stirrups. |
| 6 | Use and waste of form work to sides of concrete foundations, footings, plinth beams for rough finished concrete surfaces |
| 7 | Use and waste of form work to sides of pillars, posts, columns for rough finished concrete surfaces |
| 8 | Use and waste of form work to sides of in floor or roof beams, beam haunchings, girders, bressumers, lintels, cantilevers, shelves incl supports, overhangs etc also splays between floors and beams etc |
| 9 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work incl sides of slab, n exc 200mm thick (Horizontal or sloping) for flat rough finished surfaces of concrete. |
| 10 | M&L for Reinforced cement concrete type B1, 1:2:4, using 20mm graded stone aggregate as in footings, plinth beams and mass concrete |
| 11 | M&L for Reinforced cement concrete type B1, 1:2:4, using 20mm graded stone aggregate as in Columns., pillars |
| 12 | M&L for Reinforced cement concrete type B1, 1:2:4, using 20mm graded stone aggregate as in floor or roof beams, beam haunchings, girders, bressumers, lintels, cantilevers, shelves incl supports, overhangs etc also splays between floors and beams etc |
| 13 | M&L for RCC nominal mix 1:2:4 type B-1 using 20mm graded stone aggregate as in slabs supported on walls, beams etc., |
| 14 | Returning filling in using excavated soil including spreading, levelling, watering and well ramming in layers not exc 25cm |
| 15 | Removal of surplus spoil to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point |
| 16 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 5cm but n exc 10cm wide |
| 17 | M&L for old size Brick work with fly ash bricks straight or curved on plan and 6 metre mean radius built in CM 1:6 all as specified |
| 18 | M&L for old size Brick work with fly ash bricks straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 |
| 19 | M&L for Rendering 10mm thickin CM 1:3 on ceiling of concrete surfaces and finishedeven and smooth without using extra cement |
| 20 | M&L for three coats of white wash on newly plastered surface on ceiling incl Preparation of new plastered surfaces |
| 21 | M&L for rendering 10mm thick in CM 1: 6 as under layer and 5mm thick in CM 1:4 mixed with water proofing compound as finishing layer to external wall surfaces and finishing the surfaceeven and smooth \ |
| 22 | Supply only liquid water proofing chemical. |
| 23 | M&L for Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) incl Preparation of new plastered wall surfaces |
| 24 | M&L for Rendering 10mm thickin CM 1:6 on fair faces of brick work or concrete surfaces and finishedeven and smooth without using extra cement on internal wall surfaces. |
| 25 | M&L for two coats of oil bound distemper over a coat of primer over 3mm thick wall care putty to internal wall surfaces incl Preparation of new plastered surfaces |
| 26 | M&L for Hardcore (stone) of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface |
| 27 | M&L for 75mm thick cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection & paving finished even and smooth without using extra cement. |
| 28 | Bitumastic gola, with 80/25 bitumen and coarse sand mixture. 1:3 by weight, at the junction of panels of plinth protection |
| 29 | M&L for 75mm thick Cement concrete 1:4:8 type D-2, using 40mm graded stone aggregate as in sub base |
| 30 | Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in brick walls |
| 31 | Supplying and laying of 20mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings laid in walls/floors complete all as specified. |
| 32 | All as per item No 31 here-in-before but of 25 mm CPVC pipes |
| 33 | All as per item No 31 here-in-before but of 50 mm CPVC pipes |
| 34 | S&F 25mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe. |
| 35 | All as per item No 34 here-in-before but 50mm bore |
| 36 | S&F PVC (SWR) floor trap with grating including jointing to solvent cement waste pipe 75 mm dia. |
| 37 | All as per item No 36 here-in-before but multi floor trap |
| 38 | S&FPVC (SWR) pipes single socketed, in any length with rubber ring joints or solvent cement, laid in floor , 75mm bore. |
| 39 | All as per item No 38 here-in-before but 110mm bore |
| 40 | M&L for glazed ceramic coloured joint free tiles in vertical surfaces,350 x 250 x 7mm or 450 x 350 x 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement including backing coat with 10mm thick in CM 1:3 all as specified and as directed. |
| 41 | M&L for Non skid ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match as in coloured tiles over and including screed bed 15 mm thick in CM 1:6all as directed |
| 42 | S&F Solid PVC door Frame of size 50mmX47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawingNote:-i) Existing wall edges will have to be finished properly in cement plaster 1:4 including fixing of 6 Nos wooden plugs for catch door frame size not exc 17Sqcm average sectional areas and 100mm long. (ii)Frame will have to be fixed to the wooden plugs inserted in wall using 6 Nos of 100mm long MS screw, 3 each on either side.(iii)PCC strip of section 5*5mm will have to be created at bottom incl smooth finish in each door opening. |
| 43 | S&F Factory Made Solid Panel PVC Door shutter 30mm thick (Style) consisting of frame made out of M S tubes for top & bottom rails, M S frame shall be covered with heat moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail and bottom rail and jointed together with solvent cement, supplying & fixing in frame at site as per specification & drawing |
| 44 | S&F Butt hinges of size 100 mm,type B11, cast brass, with aluminium hinge pin, bright polished |
| 45 | S&F Aluminium anodised barrel tower bolts of extruded section 200 mm size |
| 46 | S&F Extruded aluminium alloy handles, fabricated type, anodised 150 mm long |
| 47 | S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolt and sliding bolts of extruded sections or cast aluminium alloy and fixed. |
| 48 | S&Fin repairs vitreous china wash down water closet (pedestal pattern) , white, of style and pattern as existing, complete with and including plastic seat cover, white coloured all as directed. |
| 49 | Supply only Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device |
| 50 | Supply only PVC, syphonic action type, flushing cistern, low level, white, 10 ltrs, with inlet ball valve, float, handle and flush pipe incl. brackets including 32 mm dia flush pipe |
| 51 | S&F Vitreous China oval shaped wash basin counter type, white, size 550 x 400mm embedded on granite platforms including cutting for and pinning in ends of brackets or erecting stand brackets, incl supply and fixing of 32 mm Waste coupling of PTMT (half or full threaded) (Minimum weight 32mm-45gms) |
| 52 | Supply only Pillar taps 15mm, cast copper alloy with capstan heads, CP fancy type, screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipe and fixed. |
| 53 | S&F 32mm dia Low density polyethylene pipes of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc for wash basin |
| 54 | S&F Bib taps Chromium plated 15mm bore cast copper alloywith crutch or butter fly handle chromium plated screwed down for iron pipe or for brass ferrule fixed. |
| 55 | S&F stop valves15 mm bore chromium plated with long shank and cup (Concealed type) high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed |
| 56 | S&F 450 x 600mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with CP brass screws and cup washers |
| 57 | S&F Brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges |
| 58 | S&F PVC connection 15 mm size with PTMT nuts of length 450mm. |
| 59 | S& F Soap dish, vitreous China white, approximate size 160x 160x90mm, fixed to plugs with chromium plated brass screw |
| 60 | Supply and fix Vitreous China Urinal, Half stall type white coloured completeincluding providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) |
| 61 | M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in CM 1:4 incl pointing in white cement 1:2 using marble dust with admixture of pigment or matover andincluding cement screed 15 mm thick in CM 1:4all as directed |
| 62 | Rounding to edges of Granite/stone slabs one edge, such as in steps, cooking platform, and other similar situations. |
| 63 | S&F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) |
| 64 | S&F 40mm dia Low density polyethylene pipes of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc for urinal |
| 65 | S&F Vitreous china urinal partition white of size 310x700 mm, partition slabs terminating about 40cm above floor line |
| 66 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 67 | S&F Toilet paper holder of stainless steel with flat recessed type complete all as spcd fixed to walls with chromium plated (CP) brass screws |
| 68 | S&F rotational moulded, triple layered, polyethylene water storage tanks of capacity 500 litres (cylindrical, vertical with closed top) hoisted and fixed in position all as specified including supply & fixing of 20mm dia Ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed |
| 69 | S&F Powder coated anodised aluminium frame / shutters for doors, partitions with one or more rebates including jointing cleat for fixing etc., complete all as spcd. |
| 70 | S&F 4.0mm thick figured glass, pin head type as louvers in strips, width not exceeding 100mm fixed to aluminium frames of window / ventilator |
| 71 | M&L for rendering 10mm thick on concrete surfaces finishedeven and smooth without using extra cement in CM 1:4 with liquid water proofing liquid as per manufacturers instructions on roof slab .Note : Water proofing chemical shall be measured and paid separately |
| 72 | M&L for water proofing treatment with APP based polymeric membrane modified prefabricated five layer water proofing membrane, not less than 3mm thick and weighing not less than 3.80 Kg/Sqm reinforced with non woven polyester matt black finished over compatible primer at 0.3 litre/Sqm, touching the membrane on whole surface uniformly while unrolling the membrane by LPG and sealed with trowel after necessary preparation of surface complete all as per manufactures instructions. The over lap joint shall be provided of 75mm in longitudinal direction and 100mm in transverse direction respectively. All the angles, abutments and the drainage outlets shall be sealed with extra care to ensure full bondage. Manufactures : IWL India Ltd/SAPL (ARGO-P) Hydrates Ltd (Hydroflame)/STP. Note : The work shall be carried out be authorised applicators of manufactures.Four course of roof treatment consist of as under:-(i)Applying one coat of bituminous primer conforming to IS-3384 @ 0.30 ltr /sqm (ii)Laying of APP based membrane as specified thickness and weight (iii) Applying one coat of Bitumen grade 85/25 @ 1.2 kg/Sqm (iv)Applying two coats aluminium paints @ 100ml/sqm |
| 73 | S&FPVC (SWR) pipes single socketed, in any length with rubber ring joints or solvent cement, fixed to walls, 75mm bore. |
| 74 | All as per item No 73 here-in before but 110 mm bore. |
| 75 | S&F stack clamps of 50mm× 5mm× 5mm small flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof Bore of pipe 110mm |
| 76 | All as per item No.75 here-in before but 75mm bore. |
| 77 | S&F PVC (SWR) bend 110mm bore |
| 78 | All as per item No.77 here-in before but 75mm bore. |
| 79 | S&F PVC (SWR) bend 110mm bore, with access door |
| 80 | All as per item No.79 here-in before but 75mm bore. |
| 81 | S&F PVC (SWR) junction single, (Single T) equal or unequal for 110mm bore pipe with access door |
| 82 | All as per item No 81 here-in before but 75mm bore. |
| 83 | S&F PVC (SWR) junction double, (Double T) equal or unequal for 110 mm bore pipe with access door |
| 84 | All as per item No 83 here-in before but 75mm bore. |
| 85 | S&F PVC (SWR) vent cowl 110mm |
| 86 | All as per item No 85 here-in before but 75 mm bore. |
| 87 | M&L for 150mm dia Reinforced concrete pipes NP3, laid and jointed complete with collars. |
| 88 | M&L for cement concrete 1:3:6 type C2 using 40mm graded stone aggregate as bed to 150mm dia drain pipes including packing under and haunching against the sides of pipes after they are laid and tested. |
| 89 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required, internal dia of pipe 150mm |
| 90 | M&L for providing lintels upto 1.5m clear span on half brick partition wall with cement concrete Type B1, 1:2:4 using 20mm graded stone aggregate including necessary form work. |
| 91 | Surface excavation n.exc.30cm deep and avg 15cm deep and getting out in hard/dense soil. |
| 92 | M&L for 100mm thick Cement concrete 1:4:8 type D- 2, using40mm graded stone aggregate as in sub base |
| 93 | M&L for 50mm thick sand cushion for paver block |
| 94 | Machine pressed precast concrete interlocking paver block with grey cement and no pigment any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade |
| 95 | Providing precast cement concrete 1:2:4 type B-1 using 20mm graded stone agg in window or door cills, lintels, use with masonry), string courses, copings, landings, cover slabs for man holes etc and set in CM 1:4 |
| 96 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe 410-W (Gde E 250) quality A. |
| 97 | S&F Hand rails, half round or other steel section, drilled and counter sunk for balusters running bars, wind ties for roof including securing bolts, flat iron fillets including all necessary drilling, bolting or riveting etc., and similar work conforming to Fe-290 gde E-165 |
| 98 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, 12mm dia and 15cm long. |
| 99 | S&F 0.71 mm thick aluminium alloy colour coated roofing sheets of alloy IS designation 31500, temper H*8 conforming to IS 737 and dimension as per IS code 2676 with characteristics of good formability and corrosion resistance and troughed profile with centre to centre pitch of 200mm, depth of 32mm, overall profile width 1092mm, cover width 1000mm at all heights, levels and locations. The profile sheet shall be fixed to steel members in slope or reqd pitch or curvature with hex cap headed self drilling / tapping SS screws M6, 60mm long with 3mm EDPM seal washer etc., all inclusive of scaffolding, T & P and sundries etc., |
| 100 | Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1 : 3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., and cutting chases for concealed water tubing or concealed conduit wiring etc., and making good in brick / concrete walls exc 10cm but not exc 20 cm girth. |
| 101 | M&L for preparation of new steel surfaces over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as spcd and as directed. |
| 102 | All as per item No 101 above but n.exc10 cm in width or girth. |
| 103 | Cutting holes in brick wall in cement mortar for inserting hold fast and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required depth of embedded portion of hold fasts or lugs thickness exc half brick and not exc 1 brick. |
| 104 | S&F MS Hold fasts confirming to Fe-290 Grade E-165 |
| 105 | S&F collapsible steel gates, top hung consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc, as specified erected in position and securing runners with hold fasts and brackets complete. |
| 106 | S&F solid PVC wall lining consisting of 5 mm thick single side prelam PVC sheet inclusive of solvent cementand fixing at site on PVC frame as per specification and drawing. |
| 107 | S&F 5mm thick PVC fillets of width 35 mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specification. |
| 108 | Taking down door shutters exc 1 sqm and not exc 2 sqm each and refixing in the same opening. |
| 109 | S&F Anodised aluminium snap grid frame work size of grid 605 x 605 mm forfalse ceiling all as specified. |
| 110 | M&L for 4mm thick non asbestos fibre cement building board fixed or laid/inserted to aluminium frame work in ceiling flat. |
| 111 | Preparation of new ceiling surfaces and applying two coats of oil bound distemper all s specified. |
| 112 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handle 2 Nos in each door, hinges anodised aluminium snap beading , screws etc completeall as specified. |
| 113 | M&L 12 mm thick pre-laminated particle board exterior grade prelaminated both sides with decorative choice laminations fixed with screws. |
| 114 | S&F 4.8 mm thick sheet glass, ordinary quality and fixed with aluminium beading in square exc 0.5 sqm in each pane. |
| 115 | Taking down carefully copper/ Aluminium point wiring (light, fan, socket or power) complete (fitting such as switches, ceiling roses, pendants, regulators, sockets, etc can be measured separately) removing the material from wall/ceiling etc, making good the disturbed surfaces and taken as credit. |
| 116 | Material and Labour for Point wiring complete with 1.5 sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade, multistranded copper conductor drawn through and including non-metallic rigid PVC conduit PVC conduit fittings and conduit accessories concealed in walls, roofs and floors etc., including Modular flush boxes and Modular cover plates for switches concealed in walls, roof and socket / electronics fan regulator / telephone socket,including provision of 1.5 sqmm PVC insulated unsheathed cable with multi stranded copper conductor as earth continuity conductor and connecting to common earth dolly all as specified for one light/fan point controlled by one way switch complete including cutting chases, pinning in, making good tofacing where required and pointing in cement mortar 1:3 for concealed conduit wiring and making good the disturbed surfaces, matching with the existing wall surfaces, cutting not exceeding 10 Cm girth all as specified and as directed. |
| 117 | (a) One light point controlled by one switch. |
| 118 | (b) One Exhaust Fan controlled by One Switch / Ceiling |
| 119 | (c) One 3 pin 5 amps switch socket on independent board. |
| 120 | (d) One 3 pin 5 amps switch socket on same board along with other switches. |
| 121 | (e) One bell point controlled by bell push switch on independent board |
| 122 | All as per item No 116 herein before but with 2.5 Sqmm single core PVC cable for one 3 pin 15 amps switch socket outlet on independent board.Note for item Nos.116 to 117:- (a) The wiring shall be done in proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.(b) For concealed wiring the quoted rate shall be inclusive wherever required cutting chases etc. |
| 123 | Supply and fix Wall mounted LED 20 W Batten Basic all purpose surface and wall mounted LED batten with Aluminium housing & Integrated electronic driver all as specified and as directed. |
| 124 | Supply and fixing wall mounted LED batten, Extruded aluminium housingprovided efficient heat dissipation withpolycarbonate diffuser with integrated electronic driver high efficacy. short circuit & voltage cut off protection, wide operating voltage range of 140V to 270V wide, lumen output of 1050,10W including lamp with complete all as specified and as directed. |
| 125 | Supply and fix 30W MP Bldg Sec lights new generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP 66 roadway luminaries with high power LEDs as light source and electronic driver of lamp type 30W LED 6000K all as specified and as directed. |
| 126 | Supply and fix MCB Distribution board, 240 volts single pole and neutral, double door, sheet steel, enclosure powder coated with 100 Amps rated bus bar with neutral link, 8 ways, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed. |
| 127 | Supply & Fix MCB SP 230 volts, 40 amps \"C\" Curve 10 kA Capacity complete all as directed. |
| 128 | Supply & Fix MCB SPN 230 volts, 40 amps \"C\" Curve 10 kA Capacity complete all as directed. |
| 129 | S&F Ceiling rose surface bakelite 65mm x 50mm two to three terminals all as directed. |
| 130 | S&F Modular switch 1 way 6A, 1 module, 240 Volts complete all as specified and directed |
| 131 | S&F Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed |
| 132 | Supply and fix Exhaust Fan 300mm Metal Body Heavy Duty all as specified and as directed. |
| 133 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out soft / loose soil for laying cables / pipes / erection of poles etc all as specified and as directed. |
| 134 | Removing using excavated material surplus soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as directed. |
| 135 | Returning filling in using excavated soil including spreading levelling watering well ramming in layers not exceeding 25 cm each all as directed. |
| 136 | Supplying and laying burnt brick \"B\" class standard size for protection of cable as directed. |
| 137 | Supply, lay, spread in trenches fine aggregate Sand including spreading, levelling, punning for cushioning of cable all as directed. |
| 138 | Supply & Lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 2 core 10 Sqmm all as specified and as directed.Note :-i) Lugs and glands are deemed to be included in the rate quoted for laying of cable and to be used properly wherever required while connecting cables to the panel board.ii)Earth work such excavation, refilling, etc. shall be measured separately under relevant items. |
| 139 | S&F of tubes light grade of size 40 mm dia galvanised with all fittings and fixed complete to walls and ceiling or laid in trenches, fixed on pole /under road crossing or passing through gutters etc including necessary road cutting and making good with PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate complete including taking down old u/s GI tubing all as specified and as directed. |
| 140 | M&L for Earthing complete with galvanised steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried directly in ground vertically to a depth of not less than 2.25 mtr below normal ground level with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanised iron/steel earth strip 25x4 by means of bolts, nuts, washers and check nuts made out of galvanised iron, protected by GI pipe light grade 15 mm bore dia and connected to main control board all as shown in Electrical plate No 3 of MES SSR Part I including necessary excavation and earth work in any type of soil, salt, charcoal dust, PCC 1:2:4 type B1 in chamber, RCC 1:2:4 chamber cover with 6 mm dia MS bar at 100 mm centre to centre both ways and MS 6 mm dia hook complete all as specified and directed. |
| 141 | M&L for sub main wiring with PVC insulated, FRLS 1100 volts grade single core multistranded copper conductor cable conforming to IS specifications, 2 runs of 6 sqmm including one run of 6 sqmmsingle core multistranded copper conductor PVC insulated cables as earth continuity conductor with colour code drawn through and including one run of 25 mm dia rigid PVC conduit and conduit accessories or casing capping incl accessories fixed on wall/ceiling etc., or concealed in wall and connecting to common earth dolly including taking down old unsv all as specified and directed. Note:- (a) The wiring shall be done in proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.(b) For concealed wiring the quoted rate shall be inclusive wherever required cutting chases etc. |
| 142 | Supply and fix Rigid Non metallic PVC Conduit 20 mm dia, medium grade all as directed. |
| 143 | Taking down carefully by unscrewing from boards/outlet boxes, wall ceiling fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, with plug, switch fuse and regulators etc., taken as credit and making good the disturbed surfaces of wall etc all as directed. |
| 144 | Supply and Fix Switch piano flush type 5 amps single pole, one way, 240 Volts all as directed. |
| 145 | Supply and Fix Switch socket outlet 3 pin, 5 amp, flush typeall as directed. |
| 146 | Supply and Fix Bell push flush type 5 amps single pole 240 Voltsall as directed. |
| 147 | Supply and Fix Bell ding dong, AC, 230 volts, single pole all as directed. |
| 148 | Supply and Fix Switch socket outlet multipurpose 3 pin, 15 amp and one pin, 5 amp controlled by one switchall as directed. |
| 149 | Supply and Fix Switchflush type direct to fit press type 10 /20amps single pole, one way, 240 Voltsall as directed. |
| 150 | Supply and Fix Socketflushtype direct to fit press type 10 /20 amps single pole, one way, 240 Voltsall as directed. |
| 151 | S&F Modular Fan step regulator, 120W - 1 module for ceiling Fan of 1200 mm sweep all as specified and as directed. |
| 152 | S&F Modular white cover with plate with frame 3 module incl matching with white cement wk if necessary |
| 153 | S&F Modular white cover with plate with frame 8 module incl matching with white cement wk if necessary |
| 154 | S&F Modular flush box 3 module |
| 155 | S&F Modular flush box 8module |
| 156 | Supply and fix in replacement of metal clad socket single pole and neutral enclosure with a two pin and earth plug top and socket complete with one single pole MCB 230 Volts 20/32Amps all as specified and as directed. |
| 157 | Replacement of any type of light fitting and supply and fix Panel lighting PLANO TAPS 2x2 recess amounted luminaries which suites various ceiling types,35mm depth with tapered housing makes is most flexible to install in low clearance ceiling. Unique Dual Optics-Primary (Individual PMMA Lense on LEDs)& Secondary (Opal diffuser ) to ensure homogeneous uniform lighting distribution and unmatched visual comfort. Make Havells Cat Part no PLANO2x2PLR36WLED830TAPS /Equivalent make as listed in PS |
| 158 | Supply and install hi wall split units indoor/ outdoor complete with cordless remote control unit and inbuilt air ioniser and plasma filter for better indoor air quality with minimum 4 star rating and EER 3.2 of capacity 1.5 TR |
| 159 | Supply and fix Voltage stabiliser for automatic operation single phase naturally air cooled indoor & designed for input variation between 170 V to 250 V with output voltage stabilised at 230 volts with accuracy of + 2.5% and of capacity 4KVA |