}

Tender For Operation And Maintenance Of Street Light Panel Repairing Work Of Electrical Dept Of Trimbak Municipal Council, trimbak-Maharashtra

Directorate Of Municipal Administration has published Tender For Operation And Maintenance Of Street Light Panel Repairing Work Of Electrical Dept Of Trimbak Municipal Council. Submission Date for this Tender is 29-05-2025. Street Lighting Tenders in trimbak Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

49292655
Tender For Operation And Maintenance Of Street Light Panel Repairing Work Of Electrical Dept Of Trimbak Municipal Council
Tender
Indian
Maharashtra
Trimbak
29-05-2025

Tender Documents

Tender Details

Tender For Operation And maintenance Of Street Light Panel Repairing Work Of Electrical Dept Of Trimbak Municipal Council-1. In the year 2024-25 or in the middle of the year, the work of the office of Trimbak Municipal Council Electricity Department, the maintenance of street lights in the Municipal Council area and the switching on and off of the street light panels in the Municipal Council area as per the schedule given by the Municipal Council. 2 Tubular Type Pole Erecting Concrete Gut Center 3 Lokhandi girder (eye section) raising between poles concrete gut (concrete material with pole drop and water drain) 4 Polar Aluminum Conductor Wire Cover (complete with bracket cut shape insulator etc. and fittings) Stand/stay for 5 poles Lavane (concrete material with stand) 6 Naveen underground cable laying 4X16 sq.mm 7 Digging with DWC pipe for cable 8 old worn out poles 9. Shifting of HT/LT electric pole (eye section girder and tubular pole), well placed Kadhun from one platform, raising new platform and opening electrical conductor connection with fittings. 10 To repair the cable and start it (excavation joint material etc.) to extinguish the pit. 11 Raising concrete foundation for tubular/girder pole (2 to 3 feet height) with material 12 road divider RCC Concrete Foundation 13 Polla Eyepaint Coloring Material 14 New Ceiling Fan in Building Lavane-Supplying and erecting regular/ standard model ceiling fan of 600mm. Sweep complete erected in position as per specification no. FG-FN/CF 15 new wall fans in buildings 16 Installing new tubes (LED) in buildings 17 Installing new panel lights (LED) in buildings 18 Minor wiring repairs in buildings 19 Covering 10 Sq.mm overhead service wire for pole/street light, removing old wire and inserting new wire. 20 Street light fault clearing, repairing and other related works. 21 house wiring per watt 22 Himast pole wiring replacement and repair (wires) 23 Repairing Panel Box (Cut Out 100 A) Changing Contactor Wiring 24 Inverter fitting and corresponding wiring 25 Making decorations for Ganesh Utsav and Thorpurushachi Jayanti in the city, buying halogen/LED lamps and other related items and buying Kadhun. 26 On the occasion of second and third Shravani Monday and on the day of Shivratri, to make immediate electricity arrangements at necessary places in the Municipal Council area. 27 Municipal Council Offices Electricity to illuminate 28 2.5 sq.mm 3 core flexible copper wire 29 150 w LED Flood Light Replacement and Removal 30 2 core 4 sq.mm siuminiam armored cable sheath 31 pipe type earthing 32 5 to 10 kva generator supplies 33 Servicing 5 to 10 kva generators. 34 Steel tubular swaged pole With Double Fitting 8 m Long Pole Supply 35 Supplying and erecting electronic type driver for outdoorLED fitting26 to 45 watts 36 Supplying and erecting electronic type driver for outdoorLED fitting46 to 75 watts 37 Supplying and erecting electronic type driver for outdoor LED fitting76 to 100 watts 38 Supplying and erecting electronic type driver for outdoorLED fitting101 to 150 watts 39 Supplying and erecting electronic type driver for outdoorLED fitting151 to 200 watts 40 Supplying and erecting 20mm dia. corrugated flexible polypropylene conduit 41 Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW 42 Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW 43 Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV 44 Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV 45 Supplying and erecting recess type, 3 pin plug socket 6A with piano switch 6 A combined unit erected on polished double wooden block/ folded or screwed board with top of either wooden or plywood pasted with sunmica and with connecting leads 46 Point wiring in for light/fan/bell in 20 mm metal conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, flush type switch, earthing and required accessories as per specification No: WG-PW/SW 47 Supplying and installing armored single mode optical fiber cable with 6 fiber, core dia 50/125μm (OS1/OS2) 10/40 GBPS speed in provided underground HDPE pipe complete. 48 Supplying and erecting exhaust fan heavy duty 230 V, A.C. 50 cycles 375/380 mm. 900 RPM complete erected in position as per specification no. FG-FN/EXF 49 Supplying and erecting fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted. 50 Supplying and erecting fan hook of 10 mm. M.S. round bar grouted in RCC slab with making the site as original. 51 Supplying and erecting electronic type step regulator for ceiling fan 600/ 900/1200/ 1400 mm. sweep, complete erected on prove 52 Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0TR to 1.2TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC 53 Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBAat position as per specification no. APAC/ WAC 54 Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 22mm complete. 55 Supplying single door refrigerator domestic type of 200 to 230 litres storage capacity, minimum 5 Star inverter type, stabilizer free operation suitable for operation on 100V/300 V, 50Hz with automatic temperature control, shall be marked on unit for sealed unit in refrigeration system and marking sr. no. and date of erection complete. 56 Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter changeindication system .(for TDS more than 200) 57 Supplying, installing, testing and commissioning of single phase, 230V, 50 Hz, 1400 to 1600VA digital pure sine wave inverter with backup time of ........ hrs. based on Insulated Gate Bipolar Transistor (IGBT) technology complete as per specification no. AP-INV Each 13007 3-6-4 Supplying, installing, testing and 58 Supplying, erecting, testing and commissioning of 2kVA capacity online pure sine wave, with backup time of ....... hrs. PWM & IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS 59 Supplying and erecting 12V/100Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. 60 Supplying and erecting 12V/130Ah to 135Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. 61 Supplying and erecting 12V/200Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete 62 Supplying & erecting four pole ON LOAD change over switch, 415V, 32A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary zandle, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3 . 63 Supplying and erecting triple pole mini feeder pillar with 500V, 200A FPMCCB as incomer and 2 outgoing circuits with HRC fuse base and cartridge of 100A with aluminium bus bar erected in 14 SWG CRCA sheet box with supporting angles, self locks, gasket having IP54,IK10 protection and slanting top to be erected on provided foundation complete as per specification no. SWSWR/MFP 64 Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 65 Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 66 Supplying, fixing and commissioning MCB type change over switch 2 pole, 25 A with 3 positions (I-O-II) with centre off position as per specification no. SWSWR / MCBCOS 67 Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 68 Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB 69 Supplying and erecting static energy meter with 240V 50 Hz. AC supply 5 to 30 A, ISI mark, accuracy class 1.0 with backlit LCD display, (measuring and display kWh, kVAh, V,I,PF, frequency, kW, kVA, six months history of Energy & MD in kW & kVA) with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof PVC wires duly tested by electric supply company. 70 Supplying and erecting static energy meter with 3 x 240V 50 Hz. AC supply 10 to 60 A, ISI mark, accuracy class 1.0 with backlit LCD display, (Measuring and display Trivector, V, I, kW, PF, Hz, Last month history of kWh and MD in kW) with special features like TOD, Tamper logging, Optical Communication Port & Display in absence of Power & with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof PVC wires duly tested by electric supply company. 71 Supplying and erecting LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 , 3x240V,50 Hz with optical & RS 232 port, backlit LCD, measure & display trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF events, instantaneous parameters of rating 1/5 A with display in absence of power complete with zero adjustment & testcertificate from manufacturer erected on provided M.S. box and connected toCTs. 72 Supplying and erecting single phase 10 to 60 A net meter of accuracy class 1.0, 240V, 50 Hz, with backlit LCD display, optical port ( measures import kWh, export kWh, net kWh, V, I, kW, 12 months history of energy) with wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer 73 Supplying and erecting three phase 10 to 60 A net meter DLMS compliance of accuracy class 1.0, 3 x 240V, 50 Hz, with backlit LCD display, optical port and RJ 232 port (measures import kWh, kVAh, export kWh, kVAh, Net kWh, kVAh, V, I, kW, 6 months history of energy) with wiring connections and mounting hardware on provided panels complete with calibration certificate frommanufacturer. 74 Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 240 sq.mm., with necessary material as per specification No. CB-JT/LT 75 Supplying & erecting FRP box of size 150mm x 125mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification No. CB-SB 76 Supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm dia with 4.5x3.65x3.25 mm thickness (4.5+1.75+1.75 m) length respectively and total 8.0 m long with pole cap, base plate in provided foundation. (weight 101 kg)as per specification no. OH-PL/STP 77 Supplying, erecting, testing and commissioning of diesel generating set with alternator of 30 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 5.9 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mountedon anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWGCRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 65 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG 78 Carrying out Servicing of DG set up to 50 kVA with/without AMF Panel of any make to ensure smooth running of DG set for 30 mins on load. Checking for abnormal sound and leakages, Carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minorleakages if any. Inspect alternator, stator and rotor for normal speed & proper frequency, Examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping up with Distilled water, Checking V belts with necessary adjustment, Checking and retightening of nut bolts including coupling bolts of engine and alternator, Checking & cleaning of radiator and leakage testing Checking of radiator & fuel supply hose pipes, Checking of AVR, excitation diodes, its connections confirming proper output voltage. Checking & resetting of valve tappets, Cleaning of DG set internally using blower, cleaning radiator, Attending breakdowns as and when required during One month period or during VIP visit within 2 hours of intimation and Submit the servicing report to engineer in charge.(Non Comprehensive) as per specification No. GEN-SER-AMC 79 Supplying, erecting, testing and commissioning 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR 80 Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. 81 Refilling of fire extinguisher of CO2 type by dismantling from site to workshop for refilling which includes removing of existing powder and cleaning the cylinder, delivery pipe , nozzle internally and refilling new powder complete with reinstalling properly at site with necessary certificate. 82 Making trench in soft soil having 0.75 m depth and minimum 0.3 m width for laying provided cables up to voltage level of 1.1kV complete As per specification No. CW-EXN-CTR 83 Excavating soft murum / soft soil road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site good complete. 84 Making cement concrete foundation including excavation ( 45 x 45 x 120 ) cm deep in 1:3:6 cement concrete, 20 to 25 mm stone metal, (45 x 45 x 45) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (for 6 m pole) 85 Supplying and erecting mains with WP 2 x 2.5 sq. mm. 1100 V grade aluminium PVC insulated and PVC sheathed wires on G.I. bearer wire No. 8 SWG complete erected with required size of porcelain reel insulators and 16 SWG G.I. binding wire. 86 Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW 87 Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. 88 Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete. 89 Supplying and erecting modular type D.P. switch 32A with indicator, duly erected on provided plate and box with wiring connections complete. 90 Supplying and erecting 16 to 32 A, 10kA, DPMCB suitable to fix in 2 module of modular switch in provided box complete & duly concealed with necessary material and connected. 91 Supplying and erecting modular type 5 pin socket with safety shutters 3 module socket 6A 240V AC supply, duly erected on provided plate and box with wiring connections complete duly erected.

Key Value

Document Fees
INR 2000 /-
EMD
INR 10000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail