Tender For Road Signage Work On Delhi Kanpur Road (Old N.H.-91) Odr From Km. 83.746 To 90.785 - 15 m-18 m Span Over Head Structure with 300 dia M S - two vertical postSupply, fixing & eraction of built up Overhead Structure of 15M-18M span comprising of two vertical posts of 6.00 M height made up of 300 mm NB heavy class MS pipe as vertical member welded with 10 mm MS plate at top & 12 mm M S plate at bottom. The horizontal Truss shall comprise of 50 mm dia heavy class M.S. pipe and 40 mm dia heavy M S pipe as bracing & 10 mm MS plate at bottom for fixing to vertical post as per structure design & drawing with one of steel primer and two coats of synthetic enamel plant. The work includes construction of RCC Foundation of size 0.90x0.90x1.50 m of required depth as per site condition for built up structure including Earth work in excavation 100 mm thick Lean Concrete in 1:3:6 (cement coarse sand and 40 mm gauge stone ballast and RCC M-25 cement concrete including supply and fixing of 25 mm dia Foundation Bolts 600 mm long as per provision of structure design including cost of reinforcement & shuttering. The lateral vertical clearances and complete. Installation work shall be as per relevant clauses of MORT&H specification section 800 and IRC 67 2012 complete in all respect. The Rates shall include cost of design, fabrication, supply, transportations, Local shifting Erection of Signage structure using crane, inclusive of all taxes etc. all T&P machine, material and labour required for proper completion of work as per direction of Engineer-in-charge. SI.No. 22.08 New Item excluding GST 2 6 m Span over head cantilever Structure with 300 dia M S 1 vertical post Supply, fixing & eraction of built up Cantilever Structure 6 m span comprising of one vertical post of 6.00 M heigh made up 300 mm NBheavy class MS pipe as verticle member welded with 10 mm MS plate at Top % 12 mm MS plate at Bottom. The horizontal Truss shall comprise of 50 mm dia heavy class M.S. pipe and 40 mm dia heavy M.S. pipe bracing % 10 mm diaM.S. plate at bottom for fixingto vertical post as per structure design& drawing with one of steel primer and two coat of synthetic enamle paint. The work includes construction of RCC foundation of size 90 x 90 M of required depth as per site condition for built up structure including eart work in excavation 100 mm thick Lean Concrete in 1:4:8 cement, coarse sand & 40 mm gauge stone ballast. R.C.C. with in 1:2:4cement, coarse sand & 20 mm gauge stonegrit including supply and fixing of 25 mm dia foundation Bolts 600 mm long as per provision of structure design including cost of reinforcement & shuttering.The lateral vertical clearances and complete. Instalation work shall be as per relevant clause of MORT & H specification section 800 and IRC: 672010 compete in all respect. SI.No. 22.04 New Itemexcluding GST 3 Retro-ReflectiveSheeting type-IV with 4 mm thick ACM Double Side: Providing & fixing of reflective signs with a corrosion resistant 4 mm thick with0.4to0.5mmbothsidealuminiumskinaluminiumcompositepanel face to be fully covered with High Intensity prismatic sheeting type IV as per IRC-67:2012 retro reflective sheeting with back frame MS angle of 35x35x5 mm. Legends , letters , numerals and borders etc should be as per MoRTH specificationNo-801.3.7.Thesheetingshallhaveapressure-sensitive adhesiveoftheaggressive-tacktyperequiringnoheat,solventother preparation for adhesion to a smooth clean surface, in a manner recommended by the sheeting manufacturer. The ACM (Aluminium CompositeMaterials)shallbefixedontheBackframeMSAnglewith riveting.MicroprismatictypeIVRetroreflectivesheetingconfirmingto ASTMD4956-09shallbePressurefixed.TheRetroreflectivesheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, liner removal, adhesion,impactresistance,specularglossandfungus resistance, 3 years outdoor weathering and itshaving passed these tests shallbeobtainedfromInternational/GovernmentLaboratory/Instituteby the manufacturer of the sheeting and in case the certificate is obtained from internationalcondition,itshouldalsobeobtainedfromIndiancondition within3yearsoflaunchingofproductbythemanufactureinabroad. Alternatively, a certificate conforming to ASTM Specification (D 4956-09) on artificial accelerated weathering requirements from a reputed laboratory in Indiacanbeacceptedprovisionally.Insuchasituation,the Employer/Client,ifsodesires,couldseekforaperformanceguarantee which would be released after receipt of certificate meeting the requirement ofthreeyearsoutdoorweatheringofthesheetingasperIRC67:2012& Proof of the same Report shall be uploaded which quoting tender. The rate shallincludeallmaterials,labour,T&P,transportation,installationand incidentals all complete as per direction of the Engineer-in-Charge. SI.No. 22.11 New item excluding GST 4 Reflective Raised Pavement Markers (Cat Eye/Road Stud) Supply and fixing of raised pavement marker with Made of Plastic body of RPM/ Road Stud shall be moulded from ASA (Acrylic Styrene Acrylonitrite) or HIPS (High-Imoact Polystyrene) or Acryloniitrite Butadien Styrene (ABS) or Any other suitable material approved by the Engineer. The Marker shall supportaloadof13,635kgtestedinaccordancewithASTM D4280.The Reflectivepanelsshallconsistofnumberoflensescontatningsingleor dual prismatic cubes capable of providing total internal reflection of the light entringthelensface.Lensesshallbemouledofmethylmethecrylate conformingtoASTMD788ofequivalent.Thesloporretro-reflecting surfaceshallpreferablybe35+/-5degreetobaseandtheareaofeach retro-reflectingsurfaceshallnotbelessthan13.00sq.cm.themarker heightshall notbe lessthan10mmandshall notexceed20mm& Width shall not exceed 130 mm. The base of the marker shall be flat within 1.3 mm all road studs shall be legibly marked with the name , trade or other meansofidentificationofthemanufacture.epoxyinstallations,excess adhesive around the edge of the marker, excess adhesive on the pavement and adhesive on the exposed surfaces of the markers shall be immediately removed. The contractor shall submit a two year warranty for satisfactoryfieldperformanceincludingstipulatedretro-reflectanceofthe reflectingpanel,totheEngineer.Inaddition,atwoyearwarrantyfor satisfactoryinfieldperformanceofthefinishedroadmarkershallalsobe given by the contractor who carries out the work of fixing of reflective road markers. Incasethemarkersare displaced,damaged,getwornoutor losetheirreflectivitycomparedtostipulatedstandards,thecontractor wouldberequiredtoreplaceallsuchmarkerswithin15daysofthe intimationfromtheEngineer,athisowncost.Therateshallincludeall materials,labour,T&P,transportation,installationandincidentalsall complete as per direction of the Engineer-in-Charge. SI.No. 22.05RPM (With shank) excluding GST 5 Retro-reflectorised Traffic sign as per IRC-67-2012Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC :67-2012 made of high intensity grade sheeting type-IVvideclause801.3,fixedoveraluminiumsheeting1.5mmthick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixedtothegroundbymeansofproperly designedfoundationwithM 15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The Retro reflective sheeting shall be tested for a certificateofhavingthesheetingtestedforcoefficientofretroreflection, daytime colour and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoorweatheringanditshavingpassedthesetestsshallbeobtained from International/Government Laboratory/ Institute by the manufacturer of thesheetingandincasethecertificateisobtainedfrominternational condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTMSpecification (D4956-09) onartificial accelerated weathering requirements from a reputed laboratory in India can beacceptedprovisionally.In such a situation,the Employer/ Client,if so desires, could seek for a performance guarantee which would be released afterreceiptofcertificate meetingthe requirementofthreeyearsoutdoor weatheringofthesheetingas perIRC67:2012.Legends , letters , numeralsandbordersetcshouldbeasperMoRTHspecificationNo-801.3.7 . P xi) SI.No. 22.20 60 cm circular excluding GST 6 Retro-reflectorised Traffic sign as per IRC-67-2012Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC :67-2012 made of high intensity grade sheeting type-IVvideclause801.3,fixedoveraluminiumsheeting1.5mmthick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixedtothegroundbymeansofproperly designedfoundationwithM 15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The Retro reflective sheeting shall be tested for a certificateofhavingthesheetingtestedforcoefficientofretroreflection, daytime colour and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoorweatheringanditshavingpassedthesetestsshallbeobtained from International/Government Laboratory/ Institute by the manufacturer of thesheetingandincasethecertificateisobtainedfrominternational condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTMSpecification (D4956-09) onartificial accelerated weathering requirements from a reputed laboratory in India can beacceptedprovisionally.In such a situation,the Employer/ Client,if so desires, could seek for a performance guarantee which would be released afterreceiptofcertificate meetingthe requirementofthreeyearsoutdoor weatheringofthesheetingas perIRC67:2012.Legends , letters , numeralsandbordersetcshouldbeasperMoRTHspecificationNo- 801.3.7 . P xi) SI.No. 22.20Bollardexcluding GST 7 Bollard (Single Side)Supply&fixingofBollardmade(SingleSide)outof2mmthick aluminiumsheetfacetobecoveredwithhighintensityprismatic grade type IV sheeting , Legends ,letters , numerals and borders etcshouldbeasperMoRTHspecificationNo-801.3.7.Welded poly shaped to make it monolithic pillar size 1200 mm high Bollard is having a frame 900x600 mm and 600 mm dia for fixation made out of 35 x 35 x 5 mm angle iron and from side is fully cover. (size of foundation 0.45x0.45x0.60m) .excluding GST 8 providing and fixing with painting and lettering of KM Hectetc excluding GST