Replacement of pumping Machinery at Srirampur and house wiring, illumination arrangement at Dogachiya, Jahanngar water supply schemes under Central Mechanical Division P.H.E. Dte.- 1 Srirampur PH 1 2 Thorough checking for finding out the faultin Pumping machinery as per direction of EIC. 3 Carrying charges for carrying 17.5 HP pump motor set from PHE office (purto Bhavan) to Srirampur water supply scheme including loading & unloaidng complete as per direction of E.I.C. 4 Supply & delivery of thefollowing materials. 5 3 mtr long 100 mm dia UPVC standard type column pipe [cream color] with both side threaded and one end side socketed with registered KPMG. 6 1.5 mtr long 100 mm dia UPVC standard type column pipe [cream color] with both side threaded and one end side socketed with registered KPMG. 7 80mm. dia. top & bottom adaptor 8 Heavy type suitable dia. MS suspension clamp along with nuts bolts and washers . 9 Heavy type 250mm dia split type tube well cover with 12 mm thick clamping arrangement including holes of column pipe, air pipe and cable entry with 2 sets heavy type suspension clump, nuts, bolts and washer as per departmental design. 10 Anti snapping safety device for pump set by supplying suitable size or MS angle busket and nylon rope of required length includingsupplying of nuts, bolts and all other materials. 11 100 Amp. Re-wireable type TPN main switch (CONFORMS: IS/IEC600947-1&3). (Make: Approve make of P.H.E. Dte.) 12 1.1 KV grade 6 sq.mm x 3 Core water proof flat submersible cable for above motor. 13 Steel Plug, M. S. Nipple, Flange, Nuts, Bolts etc 14 FASD Three Phase415 v ,Submersible Pump starter with Single Phase Preventer(20 HP).(relay range 12.5-20 amp).make- siemens/approved make 15 Hiring charges of derrick set for withdrawing of pumping machinery as per direction of EIC. 16 Withdrawing of 17.5 HP oldpump-motor setby hired derick arrangement after disconnection of all electircal and pipe line connection completeas per direction of EIC. 17 Installtionof supplied 17.5 HP pumping machinery & above supplied items by hired derick arrangement and making all electrical and pipe line connection complete as per direction of EIC. 18 Supply & delivery of thefollowing Items. 19 4ft long 20 watt LED tube light set.make-Phillips/approved make 20 14 watt Led lamp.(make-Phillips/approve make) 21 analog ammeter 0-50 amp.(make-AE/approved make) 22 analog voltmeter 0-500 volt.(make-AE/approved make) 23 voltmeter selection switch.make-approved make 24 102 mm. dia. 0-7 Kg./sq.cm. range, wall mounted pressure gauge (Make: H. Guru/Febig /Approved Make). 25 Voltage monitoring relay 7UG0753 as per sample.make-GIC 26 Indicating Lamp RED.make-ABB 27 Indicating Lamp Blue.make-ABB 28 Labour charges for fitting fixing of above items and testing complete as per direciton of EIC. 29 Supply & fitting fixing of 45 watt, LED Fixture set for Phillips Model no. BRP 031 LED with 40mm. dia. × 2.5mtr. long G.I pipe bracket fixing on wall of the Pump House with 3nos. M. S. clamp properly grouting including making power connection with supply and drawing 2.5sq.mm. copper flexible cable wire with controlling sub switch and continuous earthing from nearest junction board all complete as per direction of E.I.C. 30 Srirampur Ph 2 31 Supply & delivery of thefollowing Items. 32 102 mm. dia. 0-7 Kg./sq.cm. range, wall mounted pressure gauge (Make: H. Guru/Febig /Approved Make). 33 Indicating Lamp RED.make-ABB 34 Indicating Lamp Blue.make-ABB 35 Labour charges for fitting fixing of above items and testing complete as per direciton of EIC. 36 Supply & fitting fixing of 45 watt, LED Fixture set for Phillips Model no. BRP 031 LED with 40mm. dia. × 2.5mtr. long G.I pipe bracket fixing on wall of the Pump House with 3nos. M. S. clamp properly grouting including making power connection with supply and drawing 2.5sq.mm. copper flexible cable wire with controlling sub switch and continuous earthing from nearest junction board all complete as per direction of E.I.C. 37 Jahannagar PH 1 38 Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire in PVC csing caping FR with 1x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire to light/fan/ points with Piano Key type switch fixed on switch board cum JB. 39 a) average run 5 mtr. - 40 Supply & delivery of thefollowing Items. 41 4ft long 20 watt LED tube light set.make-Phillips/approved make 42 14 watt Led lamp.(make-Phillips/approve make) 43 Bulkhead light fittings on wall (Make- Bajaj/ Havells/ approvedmake) 44 16A DP MCB with enclosure (Make- Havells/ Siemens/ ABB/ L&T) 45 Labour charges for fitting fixing of above items and testing complete as per direciton of EIC. 46 Supply and fitting fixing of 25 watt. LED light fixture set[Make: Philips (Type- BRP)/ Havells/ PHED approved make] with 40 mm dia x 2.5 mtr. long G.I pipe bracket fixed on the roof of the pump house with M.S clamp properly grouting including making power connection with supply & drawing 2.5 sq. mm FR grade flexible copper wire through PVC casing/conduit with drawing earth conductor (1.0 sq mm copper flexible wire), S&F of 15 amp switch with pvc board including electrical connection & testing complete as per direction of EIC. 47 Supply and fitting fixing of Ceiling fan (Make: Usha /Crompton/Havels/ other approvedmake) 1200mm. sweep complete with blade, rubber bush etc. including supply and fixing 2×1/1.4 PVC copper wire for down rod with making necessary connection complete. 48 Makingearthing arrangement 49 Earthing with 50 mm dia Gl pipe 3.64 mm thick x 3.04 Mts.long and 1 x4 SWG Gl (Hot Dip) wire (4 Mts. long), 13 mm dia x80 mm long Gl bolts, double nuts, double washers incl. S & F 15mm dla Gl pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above groundlevel driven to an average depth of 3.65 Mts. below the ground level as below: By lSl-Medium Gl pipe 50 Extra for providing masonery enclosure on the top of the earthelectrode of overall size 86.36 cm x 86.36 cm x 46 cm deep(below Ground level) complete with cemented brick work(1:6)of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm withlocking arrangement, Gl reducer including drilling of 46 nos.12 mm dia holes on the Gl pipe 51 Extra for treatment of soil by using salt & charcoal or coke. 52 Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with Gl saddles as required and connection to equipments incl.drilling holes, with bolts, nuts, washers etc. 53 Supplying and fitting-fixing of earth busbar of galvanized (Hot dip) fVS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with Gl bolt,nuts,washers,spacing isolator set etc.as required Length of busbar is 0.5 mtr. 54 Supply & fitting fixing of thefollowing Items. 55 6 sq. mm 2 core 1.1 KV grade XLPE insulated Al. armoured Cable conforming to IS:7098 (Part-I) 2011 with upto date amendments. [Make- Gloster/ Mescab PHED approved Make] 56 40W LED Decorative Post top for 3600light with IP 65 protection for gate light. [Make: Havells (Type- RUBYPT40W) / Philips/ PHED approved make] 57 100W LED flood light luminarie with IP 65 protection.[Make: Philips (Type- BVP)/ Havells/ PHED approved make] 58 Jahannagar PH 2 59 Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire in PVC csing caping FR with 1x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire to light/fan/ points with Piano Key type switch fixed on switch board cum JB. 60 a) average run 5 mtr. - 61 Supply & delivery of thefollowing Items. 62 16A DP MCB with enclosure (Make- Havells/ Siemens/ ABB/ L&T) 63 14 watt LED lamp (Make- Philips/ Havells) 64 4 long 20 watt LED tube light set white colour (Make -Philips/ Havells) 65 Bulkhead light fittings on wall (Make- Bajaj/ Havells/ approvedmake) 66 Service charges for dismantling of damage item andfitting fixing of above itemsand testing complete as per direciton of EIC. 67 Supply and fitting fixing of Ceiling fan (Make: Usha /Crompton/Havels/ other approvedmake) 1200mm. sweep complete with blade, rubber bush etc. including supply and fixing 2×1/1.4 PVC copper wire for down rod with making necessary connection complete. 68 Supply and fitting fixing of 25 watt. LED light fixture set[Make: Philips (Type- BRP)/ Havells/ PHED approved make] with 40 mm dia x 2.5 mtr. long G.I pipe bracket fixed on the roof of the pump house with M.S clamp properly grouting including making power connection with supply & drawing 2.5 sq. mm FR grade flexible copper wire through PVC casing/conduit with drawing earth conductor (1.0 sq mm copper flexible wire), S&F of 15 amp switch with pvc board including electrical connection & testing complete as per direction of EIC. 69 Makingearthing arrangement 70 Earthing with 50 mm dia Gl pipe 3.64 mm thick x 3.04 Mts.long and 1 x4 SWG Gl (Hot Dip) wire (4 Mts. long), 13 mm dia x80 mm long Gl bolts, double nuts, double washers incl. S & F 15mm dla Gl pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above groundlevel driven to an average depth of 3.65 Mts. below the ground level as below: By lSl-Medium Gl pipe 71 Extra for providing masonery enclosure on the top of the earthelectrode of overall size 86.36 cm x 86.36 cm x 46 cm deep(below Ground level) complete with cemented brick work(1:6)of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm withlocking arrangement, Gl reducer including drilling of 46 nos.12 mm dia holes on the Gl pipe 72 Extra for treatment of soil by using salt & charcoal or coke 73 Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with Gl saddles as required and connection to equipments incl.drilling holes, with bolts, nuts, washers etc. 74 Supplying and fitting-fixing of earth busbar of galvanized (Hot dip) fVS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with Gl bolt,nuts,washers,spacing isolator set etc.as required Length of busbar is 0.5 mtr. 75 Dogachiya PH 1 76 Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire in PVC csing caping FR with 1x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire to light/fan/ points with Piano Key type switch fixed on switch board cum JB. 77 a) average run 5 mtr. - 78 Supply & delivery of thefollowing Items. 79 16A DP MCB with enclosure (Make- Havells/ Siemens/ ABB/ L&T) 80 14 watt LED lamp (Make- Philips/ Havells) 81 4 long 20 watt LED tube light set white colour (Make -Philips/ Havells) 82 Bulkhead light fittings on wall (Make- Bajaj/ Havells/ approvedmake) 83 Service charges for dismantling of damage item andfitting fixing of above itemsand testing complete as per direciton of EIC. 84 Supply and fitting fixing of Ceiling fan (Make: Usha /C.G / Havells/ approvedmake) 1200mm. sweep complete with rubber bush, nut, bolt etc. including supply and fixing 2×1/1.4 PVC copper wire for down rod with making necessary connection complete. 85 Supply and fitting fixing of 25 watt. LED light fixture set[Make: Philips (Type- BRP)/ Havells/ PHED approved make] with 40 mm dia x 2.5 mtr. long G.I pipe bracket fixed on the roof of the pump house with M.S clamp properly grouting including making power connection with supply & drawing 2.5 sq. mm FR grade flexible copper wire through PVC casing/conduit with drawing earth conductor (1.0 sq mm copper flexible wire), S&F of 15 amp switch with pvc board including electrical connection & testing complete as per direction of EIC. 86 Makingearthing arrangement 87 Earthing with 50 mm dia Gl pipe 3.64 mm thick x 3.04 Mts.long and 1 x4 SWG Gl (Hot Dip) wire (4 Mts. long), 13 mm dia x80 mm long Gl bolts, double nuts, double washers incl. S & F 15mm dla Gl pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above groundlevel driven to an average depth of 3.65 Mts. below the ground level as below: By lSl-Medium Gl pipe 88 Extra for providing masonery enclosure on the top of the earthelectrode of overall size 86.36 cm x 86.36 cm x 46 cm deep(below Ground level) complete with cemented brick work(1:6)of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm withlocking arrangement, Gl reducer including drilling of 46 nos.12 mm dia holes on the Gl pipe 89 Extra for treatment of soil by using salt & charcoal or coke 90 Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with Gl saddles as required and connection to equipments incl.drilling holes, with bolts, nuts, washers etc. 91 Supplying and fitting-fixing of earth busbar of galvanized (Hot dip) fVS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with Gl bolt,nuts,washers,spacing isolator set etc.as required Length of busbar is 0.5 mtr. 92 Supply & fitting fixing of thefollowing Items. 93 6 sq. mm 2 core 1.1 KV grade XLPE insulated Al. armoured Cable conforming to IS:7098 (Part-I) 2011 with upto date amendments. [Make- Gloster/ Mescab PHED approved Make] 94 40W LED Decorative Post top for 3600light with IP 65 protection for gate light. [Make: Havells (Type- RUBYPT40W) / Philips/ PHED approved make] 95 100W LED flood light luminarie with IP 65 protection.[Make: Philips (Type- BVP)/ Havells/ PHED approved make] 96 Kalyanpur PH 1 97 Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire in PVC csing caping FR with 1x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire to light/fan/ points with Piano Key type switch fixed on switch board cum JB. 98 a) average run 5 mtr. - 99 Supply & delivery of thefollowing Items. 100 16A DP MCB with enclosure (Make- Havells/ Siemens/ ABB/ L&T) 101 14 watt LED lamp (Make- Philips/ Havells) 102 4 long 20 watt LED tube light set white colour (Make -Philips/ Havells) 103 Bulkhead light fittings on wall (Make- Bajaj/ Havells/ approvedmake) 104 Service charges for dismantling of damage item andfitting fixing of above itemsand testing complete as per direciton of EIC. 105 Supply and fitting fixing of Ceiling fan (Make: Usha /C.G / Havells/ approvedmake) 1200mm. sweep complete with rubber bush, nut, bolt etc. including supply and fixing 2×1/1.4 PVC copper wire for down rod with making necessary connection complete. 106 Supply and fitting fixing of 25 watt. LED light fixture set[Make: Philips (Type- BRP)/ Havells/ PHED approved make] with 40 mm dia x 2.5 mtr. long G.I pipe bracket fixed on the roof of the pump house with M.S clamp properly grouting including making power connection with supply & drawing 2.5 sq. mm FR grade flexible copper wire through PVC casing/conduit with drawing earth conductor (1.0 sq mm copper flexible wire), S&F of 15 amp switch with pvc board including electrical connection & testing complete as per direction of EIC. 107 Makingearthing arrangement 108 Earthing with 50 mm dia Gl pipe 3.64 mm thick x 3.04 Mts.long and 1 x4 SWG Gl (Hot Dip) wire (4 Mts. long), 13 mm dia x80 mm long Gl bolts, double nuts, double washers incl. S & F 15mm dla Gl pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above groundlevel driven to an average depth of 3.65 Mts. below the ground level as below: By lSl-Medium Gl pipe 109 Extra for providing masonery enclosure on the top of the earthelectrode of overall size 86.36 cm x 86.36 cm x 46 cm deep(below Ground level) complete with cemented brick work(1:6)of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm withlocking arrangement, Gl reducer including drilling of 46 nos.12 mm dia holes on the Gl pipe 110 Extra for treatment of soil by using salt & charcoal or coke 111 Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with Gl saddles as required and connection to equipments incl.drilling holes, with bolts, nuts, washers etc. 112 Supplying and fitting-fixing of earth busbar of galvanized (Hot dip) fVS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with Gl bolt,nuts,washers,spacing isolator set etc.as required Length of busbar is 0.5 mtr. 113 Add GST @ 18% 114 Add Cess @ 1%