Tender For Construction Of Bphu At Chakulia Rural Hospital Under Goalpokher-Ii Development Block- CIVIL WORKSurface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed. PWD SOR: 1/1 2 Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete (a) Depth of excavation not exceeding 1,500 mm. PWD SOR: 1/2 3 Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation PWD SOR: 1/3 4 (A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) PWD SOR: 2/4 5 Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. PWD SOR: 47 / 3 6 Pre-Constructional Anti-termite measures: (a) Anti termite treatment to bottom surface ( in case of masonry foundation and basements) and the sides (upto a height of 300 mm. from bottom) of the excavation trenches with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. area. The work shall be carried out as per specification described in 6.2.1. of code IS- 6313 (part -II) 1981. (Mode of measurment will be the plan area of foundation treated.) PWD SOR: 5/10 7 (d) Treatment to the back filling of R.C.C. foundation with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight at the rate of 7.5 ltr. per sq.m. of the vertical surface of the substructure of each side of the foundation. The work shall be carried out as per specification as described in para 6.3.1 of code IS- 6313 (part-II) 1981 (Mode of measurement will be per sq.m. of vertical area of foundation treated) PWD SOR: 6/10 8 25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturers specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface). [Note: - Waterproofing as per item 9, polymer based paint as per item 8 (a) of subhead C of Section (C). PWD SOR: 47 / 1 9 Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. PWD SOR: 14 / 1 10 (I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (A) [Pakur Variety] Ground Floor (a) 1:3:6 proportion PWD SOR: 34 / 22 11 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes (i) Pakur Variety a) Gr Flr and Foundation 12 b) First Floor 13 c) Second Floor 14 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. PWD SOR: 43/40 III.Other thanSAIL/ TATA/RINL (a) For works in foundation and upto roof of ground floor/upto 4 m 15 (b) in first Floor 16 ( c) in second floor 17 Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (When the height of a particular floor is more than 4 m the equivalent floor height shall be taken as 4 m and extra for works beyond the initial 4 m ht. shall be allowed under 12 (e) for every 4 m or part thereof) Steel Shuttering9 to 12 mm thk approved quality plyboard shuttering in any concrete works direction of Engineer-In-Charge. PWD SOR: 42 / 36 a) in foundation and Gr Flr 18 b) in First Floor 19 c) In 2nd Floor 20 Brick work with 1st class bricks in cement mortar (1:6) PWD SOR: 15/8 a) in foundation & plinth 21 b) in superstructure Gr Floor 22 c) in First Floor 23 d) in 2nd Floor 24 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. PWD SOR: 16/16 a) in ground floor 25 b) in first floor 26 c) in second floor 27 Labour for Chipping of concrete surface before taking up Plastering work. PWD SOR: 182 / 1 28 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] PWD SOR: 189 / 1 (i) With 1:6 cement mortar (b) 20 mm thick plaster I) in Gr Flr 29 II) in 1st Flr 30 III) in 2nd Flr 31 (c) 15 mm thick plaster I) in Gr Flr 32 II) in 1st Flr 33 III) in 2nd Flr 34 (ii) With 1:4 cement mortar (c) 10 mm thick plasterI) in Gr Flr 35 II) in 1st Flr 36 III) in 2nd Flr 37 Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m. PWD SOR: 192 / 15 38 Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement PWD SOR: 48 / 6(ii) 25 mm. thickIII) in 2nd Flr 39 In ground floor (Plinth Protection) 40 Extra cost of labour over grey artificial stone for (i) Chequering PWD SOR: 49 / 8 41 Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturers specified rate) for concrete of various grades. PWD SOR: 45 / 9 42 Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturers specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contrr]e) I (I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment. (B) Light Colour PWD SOR: 66 / 36 43 18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m] PWD SOR: 54 / 17 44 Supplying,fitting & fixing granite slab 15mm to 18mm thick in floor, lobby, stair, landing and treads etc. over 20mm (avg) thick base of cement morter (1:2) laid with white cement slurry @ 4.40Kg per Square meter before placing of granite and jointed with white cement slurry @ 2.0 Kg per square meter with necessary pigments and complete as per direction of Engineer-in-charge including cost of all materials, labours, curing and roughening of concrete surface complete. In ground floor (c) Area of each Granite slab above 1.00 Square meter. 45 In First floor (c) Area of each Granite slab above 1.00 Square meter. PWD SOR: 34 / 63 of 315 46 Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. PWD SOR: 64 / 35(A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a) Area of each tile upto 0.09 Sq.m (ii) Other than Coloured decorative including white 47 (B) WALL With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a) Area of each tile upto 0.09 Sq.m (ii) Other than Coloured decorative including white 48 Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) Inner Walls PWD SOR: 198 / 5 I) in Gr Flr 49 II) in 1st Flr 50 III) in 2nd Flr 51 Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturers specification) including cleaning and smoothning of surface. PWD SOR: 195 / 7 52 Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturers specification and as per direction of the EIC. (b) TwoCoats PWD SOR: 196 / 8I) in Gr Flr 53 II) in 1st Flr 54 III) in 2nd Flr 55 Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturers specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer Super Protective 100% Acrylic Emulsion Two Coats PWD SOR: 197 / 17I) in Gr Flr 56 II) in 1st Flr 57 III) in 2nd Flr 58 Supplying fitting and fixing in position approved P.V.C. door frame (Matt finish) made of extruded P.V.C. multichamber hollow section having dimensions 60mm x 50mm x 2mm (+/-0.2mm), horizontal section will be joined with vertical section by galvanised steel screws after inserting two number steel brackets as reinforcement making suitable space for placing hinges, one steel tube 40mm x 20mm x 1.20 mm will be inserted on one full vertical side of the frame (hinge side) as reinforcement, the frame will then be fixed in the opening with the help of P.V.C. expandable fastner/wooden gutties and galvanised steel screws including cost of all materials and labour, hire charges of tools and appliances, carriage of all materials, taxes and all other incidental charges complete. PWD SOR: 117 / 8 59 PVCDoor Shutter-37 mm thick Supplying fitting and fixing P.V.C. door shutter of approved quality & shade in position, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C. multicavity hollow chamber of suitable size and section with 2.0 mm (+/-0.2 mm) wall thickness, the section will have 2nos. built in beads, horizontal & vertical section shall be fixed to each other by self tapping screws and 2 nos. of solid plastic or M.S. tubular galvanised brackets of length 200mmx80mm and other100mmx100mm both 1.20 mm in each corner of the shutter frame for placing hinges. Polymer based multicavity hollow section of 105 mm x37mm with 2.0 mm (+/- 0.2 mm) wall thickness will be fitted in the middle as lock rail reinforced by solid polymer bar of 200 mm long at both ends abd screws from both sides. The section frame will then be fitted in by PVC panels of size 100 mmx20 mm with wall thickness of 1.2 mm (+/- 0.2 mm) and 2 nos. of 6 mm dia and screws from both sides 6mm dia bright rod will be inserted horizontally with both side check and nut system and stretches where fixing of hinges / hasp bolt / tower bolt / door ring are required to be strong enough to with stand wear and tear. The rate is inclusive of cost of all materials, labour, and hire of tools and plants and appliencies. Carriage of all materials taxes and all other incidental charges complete.The rate is exclusive of cost of hinges, hasp bolt, tower bolt,door ring etc. In ground floor. PWD SOR: 133 / 26I) in Gr Flr 60 II) in 1st Flr 61 Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. In ground floor (Payment will be made on the area of the gate covered by two guard rails and two extreme channels) PWD SOR: 106 / 18 62 M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge. PWD SOR: 105 / 16III) in 2nd Flr 63 (a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor. (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr PWD SOR: 104 / 13I) in Gr Floor 64 II) in First Floor 65 Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx) PWD SOR: 109 / 22 66 (a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. PWD SOR: 200 / 1a 67 A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface With super gloss (hi-gloss) (iv) Two coats (with any shade except white) PWD SOR: 200 / 2A 68 Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white For 2-Track window : Members for Bottom frame @ 0.875 Kg per Mtr. and for Top and Side frame @ 0.778 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr. For 3-Track window : Members for Bottom frame @ 1.233 Kg per Mtr. and for Top and Side frame @ 1.067 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kg per Mtr. and Interlock member @ 0.612 Kg per Mtr. PWD SOR: 245 / 15 69 Supplying, fitting & fixing of partly glazed partly panelled or fully glazed single leaf Aluminium swing door of all aluminium sections viz door frame ( top and side frame), shutter( top rail, bottom rail, lock rail, door vertical) , glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868- 1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium door with door spring,/aluminium hinges, glass / Panel board all complete as per architectural drawings and direction of Engineer-incharge. ( Excluding cost of glass/ panel board, door spring/ Al hinges, door closer, door stoper, handle, tower bolt and locking arrangment etc) 10-12 Micron thickness Annodizing film Natural white PWD SOR : 246 / 16 70 Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work). (A) In 10-12 Micron thickness Annodizing film PWD SOR: 233 / 1 I) Natural white h) Louvered windowi) Top, bottom and side member 71 ii) Louvered Section. 72 iii) Cleat angle ( Non-annodized). 73 g) Fixed glazing.i) Top, bottom and side member 74 ii) Mullion. 75 iii) Glazing clip. 76 Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws: PWD SOR: 145 / 29 (vii) 100 x 75 x 4.0mm 77 Supplying 4 lever mortice lock or any approved make and brand as per direction of the Engineer- in -Chargeii) 100 mm. PWD SOR : 243 / 12 78 Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units: PWD SOR: 239 / 2iv ) Fixed glazing. 79 v ) Louvered window. 80 Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. PWD SOR: 243 / 9i) 4mm thick clear glass. 81 viii) 8mm thick coloured / tinted / smoke glass. 82 Providing, fitting and fixing in position, medium density fibre board conforming to IS: 12406-1988 for plain and IS: 14587-1998 for prelaminated made of wood fibre bonded with Urea formaldehyde for interior grade and Phenol Formaldehyde for exterior grade conforming to per IS:848-1974 as per approved make and brand as per direction of Engineer-in-Charge.C) Both side decorative lamination (II) Interior Grade (ii) 12mm PWD SOR: 177 / 13 (c )I) in Gr Floor 83 II) in First Floor 84 Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: (a) With continuous plate base (Hexagonal/ Round rod) (iv) 125 mm grip x 10 mm dia rod. PWD SOR : 145 / 30 85 Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws PWD SOR : 144 / 26(vii) 225mm long x 10mm dia. bolt. 86 iv) 150mm long x 10mm dia. bolt. 87 i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. PWD SOR : 141 / 10(b) 250mm long. 88 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. PWD SOR : 213 / 21A) UPVC Pipes: (ii) 110 mm. Dia. 89 a) Plain Tee(ii) 110 mm. Dia 90 b) Plain Y(ii) 110 mm. Dia. 91 c) Bend 87.5 degree(ii) 110 mm. Dia. 92 d) Shoe(ii) 110 mm. Dia 93 Design, Fabrication, Supply,Delivery (factory to health facility) and Fixing of Vinayl Printed Signage/Display board ( Size of board 4 X 5 sqft - 1 nos. .) , fabricated with 16 SWG rectangular MS angle / flat iron structure. Facia to be made of 1.5 mm ACP sheet and Logo, Color,lettering style etc. will be made as per approved specification which is to be digitally printed on Vinayl sheet by computerized inscription. Vinayl printed sheet to be fixed on ACP sheet. Ready signage to be fixed on wall/roofby 50x50 mm angle iron or as per site requirementincl. The matter is to be done as per approved specification. Non-Schedule. As per rate analysis. 94 SANITARY AND PLUMBINGSupplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) PWD SOR: 12 / 19 (I) (a) For Exposed Work PVC Pipes 1. 40 mm 95 (b) For Concealed Work1. 15mm 96 2. 20mm 97 3. 25mm 98 Supplying, fitting and fixing Peets valve fullway gunmetal standar dpattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.). PWD SOR: 4/I-4i) 15mm dia 99 ii) 20mm dia 100 iii) 25mm dia 101 Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. (b) For Concealed Work (i) CPVC Pipes Class-1,SDR-11 PWD SOR: 29 / 1(b) 15mm 102 Supplying, fitting and fixing bib cock or stop cock. PWD SOR: 6 / 7 (a) (i) Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand). 103 (d) (i) Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand). 104 Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (d) 2000 litre capacity PWD SOR: 37 / 6 105 Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc. PWD SOR: 36 / 2 106 Labour for punching hole in plastic water storage tank upto 50 mm dia.PWD SOR: 38/13 107 Wash basin vitreous china of approved make (without fittings) supplied,fitted and fixed in position on 75mm X 75 mm X 75 mm wood blocks and C.I. brackets including two coats of painting of C.I. brackets (ii) 550 mm X 400 mm size PWD SOR: 41 / 1 (ii) 108 Supplying, fitting and fixing White Vitreous China Sink in position on C.I. (b) Laboratory sink with rim and overflow (i) 450 mm X 300 mm X 150 mm PWD SOR: 42 / 5(b)(i) 109 Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. (ii) 450 mm long PWD SOR: 43 / 9 110 Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps.(iii) 900 mm long PWD SOR: 43 / 10 111 Supplying, fitting and fixing 15 mm swan neck tap with left & right hand operating nob with aerator (Equivalent to Code No. 510, 510(A) and Model - TROPICAL / SUMTHING SPECIAL of ESSCO or similar brand). PWD SOR: 44 / 16 112 Supplying, fitting and fixing pillar cock of approved make. a) (i) CP Pillar Cock - 15 mm. (Equivalent to Code No. 507 & Model - Tropical / Sumthing Special of ESSCO or similar brand). PWD SOR: 45 / 19 113 Supplying, fitting and fixing with cement jointing (3:1) salt glazed stoneware pipe including excavation of earth upto 1.50 metre depth in all sorts of soil both mixed or unmixed and refilling (but excluding concreting at bottom and sides). (iii) 150 mm PWD SOR: 66 / 16(iii) 114 Supplying, fitting and fixing with cement jointing (3:1) with jute gasket soaked in cement mortar PWD SOR: 67/17(a) Stoneware bend(iii) 150 mm 115 (b) Stoneware single T or Y junction(ii) 150 mm 116 Supplying, fitting and fixing C.I. round grating(i) 100 mm PWD SOR: 67/18 117 Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Meter Length (b) 110 mm PWD SOR: 68 / 23 118 Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineerin- charge. (Payment will be made on centre line measurement of the total pipeline including specials. PWD SOR: 74 / 24(A) Above ground(ii) 110 mm dia 119 (B) Under ground(ii) 110 mm dia. 120 Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 PWD SOR: 70 / 23viii) Double Y with Door(b) 110 mm 121 xi) Door Bend (T.S.)(b) 110 mm 122 xv) Vent Cowl(b) 110 mm 123 xvi) Pipe Clip(b) 110 mm 124 (ii) Plain Tee(b) 110 mm 125 Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. (a) With P trap PWD SOR: 79 / 2 126 Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. PWD SOR: 81 / 10(a) E.W.C.(ii) Plastic (hallow type) white 127 Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete. i) Polythene Flush Pipe PWD SOR: 81 / 11 128 Supplying, fitting and fixing liquid soap container PWD SOR: 82/17 129 Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm PWD SOR: 82 / 19 130 Supplying, fitting and fixing towel rail with two brackets. (a) C.P. over brass(i) 25 mm dia. and 450 mm long PWD SOR: 82 / 22 131 Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. i) With Pakur variety. (SAIL/TATA/RINL) PWD SOR: 87 / 1 (7th Corri) 132 Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. PWD SOR: 89 / 4 - 7th Corri 0 mm thick dry brick work and 250 mm thick cement brick work (1:6) and With 25 1.00m inside dia. (SAIL/TATA/RINL) (Other than SAIL/TATA/RINL) 133 Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm. Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,Part- I.Payment will be made separetly on the basis of actual height based on relevant I.S.Code. (ii) For 20 users A) With Pakur variety. (SAIL/TATA/RINL) PWD SOR: 88 / 3 - 7th Corri 134 (I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor(A) [Pakur Variety] Ground Floor (a) 1:3:6 proportion PWD SOR: 34 / 22 135 Supply fitting and fixing Fire Exyinguisher Conforming to ISI marked ( IS 15683:2006) ABC type fire extinguisher stored pressure type of 6 kgs. Capacity , with initial filling in brand new cylinder with poder coated finish , fitted with gun metal union , discharge hose , wall mounting bracket and suitable sinage etc. complete ( Make: Fire Shield / New age / De Flame / Andex or equivalent ). A level should be pasted on the body of the Extinguisher duly signed & stamped by the Agency stating 1. Date of Installation 2. Date of Expiry/ Date of next refilling.( warranty card need to be submitted ) 136 DG SETEarth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete (a) Depth of excavation not exceeding 1,500 mm. PWD SOR: 1/2 137 Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. PWD SOR: 14 / 1 138 (A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) PWD SOR: 2/4 139 (I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (A) [Pakur Variety] Ground Floor (a) 1:3:6 proportion PWD SOR: 34 / 22 140 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes (i) Pakur Variety a) Gr Flr and Foundation 141 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. PWD SOR: 43/40 III.Other thanSAIL/ TATA/RINL (a) For works in foundation and upto roof of ground floor/upto 4 m Reinforcement (0.8% of concrete) 142 Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (When the height of a particular floor is more than 4 m the equivalent floor height shall be taken as 4 m and extra for works beyond the initial 4 m ht. shall be allowed under 12 (e) for every 4 m or part thereof) Steel Shuttering9 to 12 mm thk approved quality plyboard shuttering in any concrete works direction of Engineer-In-Charge. PWD SOR: 42 / 36 a) in foundation and Gr Flr 143 Brick work with 1st class bricks in cement mortar (1:6) PWD SOR: 15/8 a) in foundation & plinthBrick work (1:6) 144 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] PWD SOR: 189 / 1 (i) With 1:6 cement mortar (b) 15 mm thick plaster I) in Gr Flr 145 GST 18 % (FOR CIVIL WORK,S&P,DG BASE) 146 CESS 1% (FOR CIVIL WORK,S&P,DG BASE) 147 ELECTRICAL PART (SCHEDULE ITEM)SUB-HEAD I: INTERNAL WIRING All wiring Item including provision of conduit, conduit accsories , circuit wiring, switch, box and all fitting completed as required. INTERNAL WIRING Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Havells/RR Kabel/KEI/Polycab-Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall tolight/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish2x22/0.3 (Ph. & N) and 1x22/0.3 as ECCAverage run 6 mtr 148 Average run 7 mtr 149 Average run 8 mtr 150 Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire (Havells/RR Kabel/KEI/Polycab-Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light point with 2 no. 2 way piano key type switch fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works [PVC casingcapping on surface and Switch board concealed] Average run 9 mtr 151 Supplying and Drawing 1.1 KV single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Havells/RR Kabel/KEI/Polycab-Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required2x36/0.3 (1.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC 152 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC [Power & 20A Board] 153 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC [A.C. Point] 154 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC [HTPN DB to SPN DB] 155 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC [UPS] 156 3x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as Neutral, ECC [FUSE BASE to LT Panel] 157 Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.2.5 sqmm 158 4 sqmm 159 6 sqmm 160 16 sqmm 161 CONDUIT PIPESupplying and fixing polythene pipe complete with fittings as necy.. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction).19mm dia 3mm thick Polythene Pipe 162 25mm dia 3mm thick Polythene Pipe 163 Cutting Channel of size (31 mm x 31 mm) on RCC plastered ceiling by Electric operated cutting machine incl. supplying & fixing heavy gauge 13 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI U hooks of8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles19 mm dia 3 mm thick polythene pipe without earth continuity wire 164 Cutting Channel of size (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI U hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles25 mm dia 3 mm thick polythene pipe without earthcontinuity wire 165 SWITCH BOARDSDistn. wiring in 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Havells/RR Kabel/KEI/Polycab-Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish2x22/0.3 (Ph. & N) and 1x22/0.3 as ECCOn Board 166 Average run 6 mtr 167 Supply & Fixing 240 V, 4 nos. 6A, plug socket with separate 4 nos. 6 A Piano key type switch, indicator & 16A switch type SP MCB (Havells/Legrand/L&T-Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. [CPU Board] 168 Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Havells/Anchor/Legrand-Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. [Separate 20A Plug Point] 169 Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A plug socket with separate 2 nos. 6 A & 2 nos. 20A Piano key type switch, indicator & 20A switch type SP MCB (Havells/Anchor/Legrand-Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. [Power Board] 170 Supply & Fixing 240 V, 25A Modular type socket, 25 A, Modular type starter (Havells/Legrand/L&T-Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [AC Board] 171 TPN D.BSupplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Legrand / Havells / Siemens/L&T).6 way [Enclosure (LTTD06N)] [EDB-1, Gr. Fl., EDB-2, NDB-2, 1st Fl.] 172 8 way [Enclosure (LTTD08N)] [NDB-1, Gr. Fl.] 173 Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts boltsetc incl. provision for earthing attachment.6 way HTPN DB 174 8 way HTPN DB 175 SPN D.BSupplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.(Legrand / Havells / Siemens/L&T)(2+16 Way) Enclosure [ELDB1-Gr. Fl., ELDB 2-1st Fl.] [Enclosure (607713)] 176 (2+12 Way) Enclosure [LDB 1Gr. Fl., LDB 2-1st Fl.] [Enclosure (607712)] 177 Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mendinggood the damages to original finish incl. painting, connection & provision for earthing attachment4 Way [UPS: I/C & O/G] 178 MCB Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection(Legrand / Havells / Siemens/L&T) .Single pole 6-32A MCB [NDB 1,2, EDB 1,2, ELDB 1,2, LDB 1,2 O/G] 179 Single pole 32A MCB [EDB 1,2 O/G - ELDB 1,2] 180 Single pole 40A MCB [NDB 1,2 O/G - LDB 1,2] 181 Four pole 63A MCB Isolator [NDB 1,2 I/C] 182 Four pole 40A MCB Isolator [EDB 1,2 I/C] 183 Four pole 40A MCB [UPS 4 WAY I/C & O/G] 184 Double Pole 40A MCB Isolator [UPS O/G, LDB 1,2 I/C] 185 Double Pole 32A MCB Isolator [ELDB 1,2 I/C] Make-Legrand 186 SUB-HEAD III: SUPPLY & FIXING OF FANSSupply & Fixing Socket type fan regulator (Step type) (Havells/Anchor/Legrand-Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc. 187 Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box. 188 Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessaryconnection as required by 2x1.5 sqmm flexible copper wire along with fixing of safety rope 189 Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:30 cm (12) 190 Supply & Fixing louver shutter on wall with necy.. bolts & nuts (6 mm dia x 62 mm long)For Al : 30 cm Exhaust fan (12) 191 Supplying & Fixing 240 V AC Buzzer (Ancho) on HW board incl. S&F HW board 192 SUB-HEAD IV: SUPPLY, LAYING & FINISHING OF CABLELaying on Wall / surface with Saddles / clampsLaying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting 193 Laying in Underground TrenchLaying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoringsurface duly rammed 194 CABLE TERMINATIONSupplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :For 4 core upto 50 sqmm 195 For 4 core upto 35 sqmm 196 Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required65 mm dia ISI 197 Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials 198 4 core 35 sqmm cable 199 SUB-HEAD V: EARTHING:Excavation of soil for installation of Earth Electrode and filling & ramming.For Morrum Soil 200 Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By TATA-Medium GI pipe [D.G. Body:2, D.G. Neutral: 2, LT PANEL:2, UPS: 2] 201 Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe 202 Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. 203 Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. 204 Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damagesSolid GI wireNo. 6 SWG 205 SUB-HEAD VI: TELE. TV & DATA POINTS:TELEPHONE AND NETWORKING BOARDSupply & Fixing RJ45 sitable for CAT6 cable (Brand approved by EIC) with PVC board and top cover plate on wall and making necessary connections & testing as required 206 Supply & Fixing Telephone socket (RJ11) Modular type (Brand approved by EIC) with PVC board and top cover plate on wall and making necessary connections & testing as required. 207 TELEPHONE AND NETWORKING CABLESupplying & Drawing 2-pair Telephone cables with high density polyethylene insulated solid annealed high conductivity bare copper of dia 0.5mm in prelaid PVC rigid conduit / in polythene pipe embeded in wall. 208 Supplying & Drawing LAN cable (CAT6) (Brand approved by EIC) in prelaid PVC rigid conduit/ in polythene pipe embeded in wall. 209 Supplying and fixing PVC casing-capping [Precision Make] on wall or ceiling, incl. necy. PVC fittings etc. and mending good damages to building works20x10mm Size 210 Supplying & Fixing Out door type CFL/LED luminaire (Havells make-LHRC4185099 or equivalent) with deep drawn aluminium housing anodised inside & clear acrylic cover and accessories incl. for 85 watts CFL lamp / 20 watt LEDincl. S&F 32mm dia GI pipe bracket, clamp, nut & bolts etc. 211 Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitablesize of MS fastener 212 Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. 213 Fixing only lamp 214 Average District Charge 7% (On Scheduled items) (ELECTRICAL) 215 SUB-HEAD II: LT PANEL/DISTRIBUTION BOARDS LT PanelMain LT Panel :- Supply, delivery, installation, testing & commissioning of Indoor Cubical type L.T. Distribution panel board of required size, wall/stand mounted compartmentalized with maple arrangement having rigid & self supporting structure with cable alley fabricated from 2 mm thick CRCA sheet steel and 35x35x5 mm M.S. angle frame for panel mounting support and making necessary grouting arrangements with neet cementing finish as per direction of EIC. [Dim. - 1600mm x 1450mm x 350mm]. The panel board consisting of the following item:-415V, 200A electrolyte grade tinned copper BBC (Raw power Busbar & D.G. Busbar) with vertical section of 25X6mm sizefor neutral & Phases. Bus-bars shall be fixed with FRP insulator chair & seperator & the entire bars are insulated with PVC heat Sinkable sleeve of suitable size & color as per direction of E.I.C. [equal bar for each i.e. 4-bar]and interconnections for:- 125A SFU and all inter-connecting links should be made with suitable size copper strip/copper wire.A) Incomming Arrangement: a) 415V 50 Hz 125A TPN SFU (panel mounting cubicle type) conforming to IS 13947 in open execution three pole & neutral, Make- Legrand/Havells/L&T -01 no.B) Bus Section:415V, 200A electrolyte grade tinned copper bus bar, with vertical section of size 25x6mm for Phase RYB, neutral bars of each. A bus bar shall be fixed with FRP chair & the entire bars are insulated with PVC heat Sinkable sleeve of suitable size & color as per direction of E.I.C. - 02 nos.C) Outgoing Arrangement:a) 415V 125A MCCB Breaking Capacity:- 25kA/35kA with fixed thermal & fixed magnetic/adjustable thermal & fixed magnetic setting, panel mounting cubicle type conform to IS :13947, Make- Legrand/Havells/L&T-04 nos.b) 415V 125A TPN On load Changeover switch, front operated Changeover switch in open execution type, Make- Legrand/Havells/L&T - 01 no.c)Triple Pole 63A MCB (Legrand/Havells/L&T) -03 nos.d)Triple Pole 40A MCB (Legrand/Havells/L&T) -01 no.e)Double Pole 32A MCB (Legrand/Havells/L&T) -04 nos.f) Single Pole 6-32A MCB (Legrand/Havells/L&T) - 08 nos.D) Metering Panel:a) S&F 3-ph digital single function panel meter, Voltmeter (L&T)- 02 nos.b) S&F 3-ph digital single function panel meter, Ammeter (L&T) - 02 nos.c) S&F 200/5A 15VA Class-1 C.T. (KAPPA) - 06 nos. d) S&F Gen next LED phase R-Y-B indicator-Make-L&T 06 nos. e) S&F 6A SP MCB (c-curve)-Make-Legrand/Havells/L&T06 nos.f) S&F 08X06 Danger Board02 nos.E) Cable Alley:Cable entry arrangement will be provided in the cubicle panel in vertical position of size 1450mm x 350mm x 350mm with suitable capacity 4 way AC/DC connector indicating phase & neutral for each outgoing main switches & gland plate must be placed at the bottom of the panel with detachable type as per direction of E.I.C.F) Painting:The complete panel board shall be painted by 2 coats of powder coated synthetic enamel paint over two coats of R.O. primer of Approved make & brand & color as per Direction of E.I.C.G) Constructional Details:All incoming & outgoing panel mounted cubicle switch disconnector fuse shall be housed in respective compartment with hinged & gasketted door at front, All doors shall have panel lock arrangement. The panel shall be properly gasketted to prevent ingress of dust & moisture & remain. Busbar will be properly arrange & all switches shall be fixed by M.S. nuts & bolts on angle iron/flat iron frame base as per direction of E.I.C. 216 FUSE BASESupply of 2 mm thick wooden ply board of size 3 ftx2 ft and fixing the same in wall by necessary nuts, bolts etc. Incl. Supply and fixing of 3 nos. 100A, 415V, Porcelain Fuse carried and base (Havells make, cat no: IHKKRN4100) and neutral bar at wooden board. 217 SUPPLY OF FANSSupply & delivery of Sweep:- 48 (1200mm) AC ceiling fan, 50-70 Watts, Speed:->=350 RPM, Air delivery:->=220 CMM, make: (Orient PSPO NEWBREEZE or SUMMERCOOL / equivalent of EPC or USHA STRIKER PLUS or CROMPTON (with safety rope) [Approved by EIC] 218 Supply & delivery of Sweep:-36 (900mm) AC ceiling fan, 50-70 Watts, Speed:->=380 RPM, Air delivery:->=145 CMM, make: (Orient PSPO NEWBREEZE or SUMMERCOOL / equivalent of EPC or USHA or CROMPTON or HAVELLS (with safety rope) [Approved by EIC] 219 Supply & delivery of heavy duty Exhaust Fan of Sweep:-12 (300mm), 240 volt, 50 Hz, AC , 50-60 Watts, Speed >900 RPM, Air delivery >=1145 CMM suitable for . [Make - Orient(Model:Power Flow)/EPC/Havells/Crompton Greaves] [Approved by EIC] 220 Supplying of 1.1 KV. Grade LT power cable, XLPE insulated, cores laid up, PVC inner sheathed aluminium armoured conductor of the following specificaion:- (make: Polycab/Gloster/Havells)50 sqmm 4 core (A2XWY/A2XFY) 221 Supplying of 1.1 KV. Grade LT power cable, XLPE insulated, cores laid up, PVC inner sheathed aluminium armoured conductor of the following specificaion:- (make: Polycab/Gloster/Havells)35 sqmm 4 core (A2XWY/A2XFY) 222 Supply & fixing of unipolar hexagonal flat mounting insulator for busbar support for fixing of neutral earth busbar at the side of D.G. foundation & location of UPS of the following specification:-i). Polyester without halogenii) UL94 VO self-extinguishing.iii) Colour red RAL 3002.iv) Operating temperature from -40 to +130°C.v) Deformation under load temperature (ASTM D643): > 200°C.vi) Dielectric constant (ASTM D150): 4/5.vii) Arc resistance (ASTM D495): > 180 s.viii) Water absorption (ASTM D570): < 0.3%. 223 SUB-HEAD VII: SUPPLY & FIXING LED LIGHTING FIXTURE for INTERNAL WORKSupply & delivery of single 4ft Batten type LED tube light fitting,1200 mm, Efficacy>= 100 lm/W, THD<10%, complete with all accessories. (Make:-Havells: LED Pride Plus NXT Batten 22 W 6500 K) or equivalent of Philips, Crompton etc. [Approved by EIC] 224 Supply & Delivery at site 9 watt LED Bulb,Efficacy>=90 lm/W, Base Cap:-B22 [Make-Havells, LED DEKOR BULB 9 W B22 CDL] or equivalent of Crompton, Philips etc. [Approved by EIC] 225 GST 18 % (FOR ELECTRICAL WORK) 226 CESS 1% (FOR ELECTRICAL WORK) 227 WBSEDCL Charge