| 1 | Repair / maintenance of street / security/Flame proof lights any type, flood lights, post top lanterns or any other external lights in its position fixed on pole / high mast / building structure or by taking down to ground, if required, testing all the components / parts, wiring etc, identifying and replacing the defective components like, electronic driver (in case of LED lights),connector, connection wires/ cable, MCB etc including refixing the fittingto its original position (if taken down), including repair / maint of street light control timer & junction box all as directed by Engr-in-charge. Note:(i)The rate against the above mentioned item is deemed for cost of labour and allied expenses only. (ii) Spares such as, electronic driver, connector, connection wire, MCB, timer spares etc) replaced against above mentioned item will be measured & paid for separately under respective items of BOQ here-in-below. |
| 2 | (iii)The contractor\"s representative will report to concerned JE E/M at 0900hrs daily to collect the list of defectivelights fittings and will submit the completion report as per complaints received on the same daybefore 1730hrs to the JE E/M. (iv) The contractor has to rectify thedefects / repair and make the street light functional within 24 hours from the time the list of defective street lights is handed over to him / his rep by the concerned JE E/M.In case the street light is not made functional for whatsoever reason within the specified time limit, an amount of Rs 150/- per such defective street light per day will be recovered from the amount due to him through RAR / Final Bill.The contractor shall carry out repair / maint work simultaneouslyfor different areasby engaging separate team of electricians / technicians for DRDL/ASL/PCDA/MES QUARTERS area in order to ensure prompt & timely rectification of defects.(v) Contractor shall arrange requisite and cost sufficient number oftransport and vehicle mounted hydraulic ladder at his own cost wherever required. |
| 3 | (vi) The contractor shall maintain proper record of repair / maintenance in a binded register duly bringing out the details of spares replaced on each and every street light and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maintenance record register to Engineer-in-charge for inspection on every Monday or as and when asked for.(vii) The contractor shall be fully responsible for the safety of his men engaged for executing this work and he will provide all requisite safety equipments anddepartment shall not be responsible for any kind of mishap / accident / injury to his men.(viii) The contractor shall maintain sufficient stock of spares / material required for repair / maintenance of street lights with the concerned JE E/M against the supply only items here-in-below. |
| 4 | PVC insulated copper conductor FRLS grade2.5 sqmm,three core cable, ISI marked. |
| 5 | PVC insulated copper conductor FRLS grade1.5 sqmm,three core cable, ISI marked. |
| 6 | Supplying and fixing 4 sqmm stranded 1100volts grade heavy duty cablePVC insulated aluminiumconductor, served with innersheathing of PVC tape andoverall PVC sheathed inservice connections suspended by insulating hangers notmore than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular |
| 7 | Supplying and fixing6 sqmm stranded 1100volts grade heavy duty cablePVC insulated aluminiumconductor, served with innersheathing of PVC tape andoverall PVC sheathed inservice connections suspended by insulating hangers notmore than 1 metre apart including4mm suspension wire, one twin core cable flat or circular |
| 8 | Re-stringing, tightening and fixing in position, the existing OH ACSR conductor LT Line phase with neutral and earth wire 230V, 2/3 wire by loosening and taking down existing binding wire from the insulator of any size of ACSR conductor and bringing it to required sag including provision of new binding wire and tightening of cross arms on each pole and requiredtrimming of tree branchesNote: 1.Span length (any No of wires)of conductor shall be measured in running meter unit.2.Unit rate quoted by the contractor shall be deemed to include for cutting and trimming branches of the trees coming in contact with ACSR conductorand separators as directed. |
| 9 | Cutting/ trimming / punning tree branches overhanging or interfering or obstructing electrical pole or street lightsin such a way that theclearance between Street light pole and tree branches should not be less than 3 mtrs around the Pole/Fitting complete all as directed. (Note: Quoted rate is deemed toinclude necessary hydraulic ladder arrangement and tree cutting machine and tools required at site.) |
| 10 | M&L for scrapping down and removing of old deteriorated paint from steel tubular poles LT preparing surface for painting and applying black & yellow paint strips of 30 cms each upto 1.5 m above the PCC and applying one coat of red oxide and two coats of aluminium paint for the remaining height of pole including MS clamps, GI bracket, fittings etc and marking of pole No, 2m above the PCC muff, letter shall not be more than 6 cm height with 16 cm dia circle around the marked No. complete all as directed. Note : Quoted rate is deemed to include removal of any type of boards, direction plates etc and refixing the same after painting |
| 11 | S&F in repairs automatic timer switch distribution board, factory assembled in powder coated sheet steel enclosure, single Phase, suitable for 6KW load, comprising of 32 Amps, 3 Pole, MCB SPN, 40A power contactor and 230V digital timer switch for controlling street lights outdoor type,including angle iron base and stand for fixing the panel with suitable PCC foundation as per site requirement . |
| 12 | S&F in repairsautomatic timer switch distribution board, factory assembled in powder coated sheet steel enclosure, suitable for 12KW load single phase comprising of 65 Amps SP MCB, 63A power contactor and 230V digital timer switch for controlling street lights,including angle iron base and stand for fixing the panel with suitable PCC foundation as per site requirement . Note:- Rate quoted shall be inclusive of necessary excavation & earth work and PCC foundation. |
| 13 | S&Fin repairs SMC junction boxes (weather proof) IP 66,on street light poles made out of thermoplastic of size not less than 195 mmx 135 mmx 90 mm size withconnector for connecting incoming and outgoing of cableincluding provision of 01 No of MCB SP 06 Amps to control the pole light circuit andMS brackets made out of 32 x 4 mm flat for fixing the box on post complete with nuts, bolts and washers and suitable size of double compression cable glands for incoming, outgoing of cable Complete all as directed. |
| 14 | S&F in repairs of LED 45watt street light fitting made up of pressure die cast housing with toughened glass and individual LEDs with street optics and IP 66 protection, 6500K includingfixed to pole/wall with necessary MS clamp & accessories complete all as directed. |
| 15 | S&F in repairs LED street light 60 W secondary optics made in pressure die cast housing and heat shrink in aluminium extrusion and IP 66 protection, 5700K color temperature fixing to the bracket or street light pole with necessary nuts and bolts as required at site complete all asdirected. |
| 16 | S&F in repairs LED street light 90 W secondary optics made in pressure die cast housing and heat shrink in aluminium extrusion and IP 66 protection, 5700K color temperature fixing to the bracket or street light pole with necessary nuts and bolts as required at site complete all asdirected. |
| 17 | S&F in repairs LEDstreet light 100 W secondary optics made in pressure die cast housing and heat shrink in aluminium extrusion and IP 66 protection, 5700K color temperature fixing to the bracket or street light pole with necessary nuts and bolts as required at site complete all as specified and directed. |
| 18 | Supply & Fixing LED flood lights 60 watts230 V AC outdoor type with thermal management in multiple optics IP 66 Luminaire with aluminium die casting,toughened glass and unique lens system for enhanced illumination and equipped with IP66 protection with impact and corrosion resistant complete with driver and lamp including removal of existing & complete all as directed |
| 19 | Supply & Fixing LED flood lights 80 watts230 V AC outdoor type with thermal management in multiple optics IP 66 Luminaire with aluminium die casting,toughened glass and unique lens system for enhanced illumination and equipped with IP66 protection with impact and corrosion resistant complete with driver and lamp including removal of existing & complete all as directed |
| 20 | Supply & Fixing LED flood lights 100 watts230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection with impact and corrosion resistant complete with driver and unique lens system for enhanced illumination and lamp including removal of existing & complete all as directed |
| 21 | Supply & Fixing LED flood lights 150 watts230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection with impact and corrosion resistant complete with driver and unique lens system for enhanced illumination and lamp including removal of existing & complete all as directed |
| 22 | S&Fin repairs LED 80 watt highbay light fiitting made up of pressure die cast housing with toughened glass and individual LEDs withIP 66 protection, 5700K includingfixing to High mast pole/truss with necessary nuts, bolts and washers complete all as directed. |
| 23 | S&Fin repairs LED 120 watt highbay light fiitting made up of pressure die cast housing with toughened glass and individual LEDs withIP 66 protection, 5700K includingfixing to High mast pole/truss with necessary nuts, bolts and washers complete all as directed. |
| 24 | S&F in repairsIntegral LED bollards 8 watt with opal acrylic diffuser made of extruded aluminium housing and IP65 protection including PCC foundation with suitablephospher bronze/GI nuts and bolts for fixing the bollard as per site requirement complete all asdirected Note:-Rate quoted shall be inclusive of necessary excavation and concrete required. |
| 25 | Supply & Laying, jointing & testing of XLPE UG LT cables,insulated, PVC sheathed aluminium conductor multi stranded armoured heavy duty 1100 Volt grade laid in trenches/ducts/along poles/through pipe under road etc with new aluminium lugs for the following cable sizes all asdirected. |
| 26 | 10 sqmm 4 core |
| 27 | 16 sqmm 4 core |
| 28 | 25 sqmm 3.5 core |
| 29 | 35 sqmm 3.5 core |
| 30 | 50 sqmm 3.5 core |
| 31 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables and getting out in soft/loose soil complete all asdirected. |
| 32 | Returning, filiing in, including spreading, levelling watering and well ramminginlayers not exceeding 25 cm thick each, using soil complete all as directed. |
| 33 | Removing excavated surplus soil obtained from excavation to a distance not exceeding 1.5 m above the starting point, complete all as specified. |
| 34 | Supply and laying in repairs corrugated HDPE pipe of40mm dia for cable protection confirming IS-14930 1 & 2 , in trenches or fixing to the pole with necessary accessories complete all as directed. |
| 35 | S&F in repair light gradeGI pipe bracket of 40/32mm dia, 1.2mtr long, bent to shape for street light fitting fixed on pole using new 2 Nos FI clamps, nuts, bolts and washers complete all asdirected. |
| 36 | M& L for repair of highmast lights by taking down the light assembly by motor operation or mannually, taking out defective parts and fixing the highmast light in its original position after repairing all as directed by Engineer in charge Note : defective cabel, wire and lights will be measured and paid separately in relevant items of work. |
| 37 | Earthingwith GI plate electrode 600x 600x 6 mm thick buried directly in ground vertically to a depthnot less than 2.25 mtr deep below normal ground level with top edge of earth plate, not less than 1.5 mtr below normal ground level connected to GI wire of size 4 mm by means of bolts, nuts/check nuts and washers etc of galvanised iron, protected by 15 mm dia galvanised iron pipe, light gradeupto a length of 7.5 mtr away from earth electrode and connected to main switch/control board including necessary excavation earth work in any type of soil and PCC 1:3:6 type C1 for earth chamber,40 mm thick RCC cover slab 1:2:4 type B1 with 8 mm dia TMT Bars at 140 mmc/c both ways,GI funnel, wire mesh, lugs, charcoal and salt etc complete all as shown in Electrical plate No. 3of SSR Part I and testing complete including removing unserviceableearthing material completeall asdirected.Note : GI earth wirebeyond 7.5 metres will be measured and paid separately. |
| 38 | S&F in repairsgalvanised steel earth wire of 4mm dia on the over head LT pole with the help of aluminium tapes/ binding wire and necessary clamps for fixing the earth wire, providing the required sag for avoiding tension in earth wire complete all as directed. |
| 39 | S&F in repairs cable jointing kit forstraight through joint (epoxy) for 1.1 KV grade suitable for 3.5 coreXLPE, PVC insulated and sheathed aluminium conductor under ground cable includingthimbles, nuts & bolts, washers etc and testing after jointing complete, all as directed upto 50 sqmm size. |
| 40 | M & Lin repairs Loop type insulator of working pressure of 1.1 KV, vitreous porcelain,white, brown or green Large size, with overall dimensions90mmx140mm, clearance of hole25.5mm |
| 41 | S&F, in repairs stay assembly complete with accessories as shown in electrical plate No.1 of SSR part I including loop type insulator, stay clamps, stay strands, excavation & earthwork and PCC work complete all as specified and directed.Note:- Rate quoted shall be inclusive of necessary excavation & earthwork and concrete as required. |
| 42 | M&L for paintingthe pole number on the LT/Street Light pole in circular shape with black synthetic enamel paint background andwhite synthetic enamel painted letters.Note:- The numbers and words shall be all as directed by the Engineer-in-charge. |
| 43 | S&F Electronic driver for 45/60 watts LED road way/Flood light/post top/High Bay. |
| 44 | S&F Electronic driver for 90/100/120watts LED road way/Flood light/post top/High Bay. |
| 45 | S&F Electronic driver suitable for 150 watts LEDroad way/Flood light/post top/High Bay |
| 46 | Providing and making steel pole collar with cement concrete (1 cement : 3 coarse sand : 6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc as required. (volume of pole/ pipe not to be deducted) |
| 47 | S&F in repairs post top lantern LED type 15 watt 230 watts volts AC outdoor type with decorative post top for 360 degree indirect light IP65 protection with impact and corrosion resistant complete with driver and lamp along withnecessary wiring,accessroies complete all as directed. |
| 48 | Supply and lay GI tubing 40 mm dia, light grade for cable protection at road crossing/on poles and tubing sealed at bith ends after laying the cables including taking out old GI tubing complete all as directed. |
| 49 | S&F LED strip plate for repair of 25/35 watts LED security light fittings |
| 50 | S&F LED strip plate for repair45/50/60 watts LED road way/Flood light/post top |
| 51 | S&F LED strip plate for repair90/100 watts LED road way/Flood light/post top |
| 52 | S&F LED strip plate for repair 120/150 watts LED street light/Flood light fittings. |
| 53 | S&F in repair aluminium conductor steel reinforced any size in over head lines on LT/ HT poles including stretching the aluminium conductor and binding with binding wires of aluminium or aluminium tapes etc. Jumpers and connections, complete all as specified and directed by Engr-in-charge. |
| 54 | M & L in replacement Steel tubular swaged poles completewith cast iron base plate, finial taperplug, bolts, nuts & screws asspecified type 410 SP-22 (8.5metres long) |
| 55 | M & L in replacement Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint |
| 56 | S&F in replacement recess mounted Flame proof LED high bay light with IP-66 protection pressure die cast body with high power SMD LEDs as light source of with very luminous efficacy 50 W, 240V, aluminium heat sinkalongwith inbuilt elctronic driver, wide beam angle ,including hanging the fitting with required hook arrangement required at site, complete removingunserviceable wires/cables incluidng taking down of exisitng fixture all as specified and directed. |
| 57 | S&F in replacement recess mounted Flame proof LED high bay light with IP-66 protection pressure die cast body with high power SMD LEDs as light source of with very luminous efficacy 70 W, 240V, aluminium heat sinkalongwith inbuilt elctronic driver, wide beam angle ,including hanging the fitting with required hook arrangement required at site, complete removingunserviceable wires/cables incluidng taking down of exisitng fixture all as specified and directed. |
| 58 | S&F in replacement recess mounted Flame proof LED high bay light with IP-66 protection pressure die cast body with high power SMD LEDs as light source of with very luminous efficacy 100 W, 240V, aluminium heat sinkalongwith inbuilt elctronic driver, wide beam angle ,including hanging the fitting with required hook arrangement required at site, complete removingunserviceable wires/cables incluidng taking down of exisitng fixture all as specified and directed. |