Renovation Of Electrical Installation As Well As Replacement Of Old Panel, Main Switches And Other Necessary Works At Sealdah Court, Kolkata., sealdah-West Bengal

Public Works Department has published Renovation Of Electrical Installation As Well As Replacement Of Old Panel, Main Switches And Other Necessary Works At Sealdah Court, Kolkata.. Submission Date for this Tender is 11-06-2025. Water Wells Tenders in sealdah West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

49285666
Renovation Of Electrical Installation As Well As Replacement Of Old Panel, Main Switches And Other Necessary Works At Sealdah Court, Kolkata.
Tender
Indian
West Bengal
Sealdah
11-06-2025

Tender Documents

Tender Details

Renovation Of Electrical Installation As Well As Replacement Of Old Panel, Main Switches And Other Necessary Works At Sealdah Court, Kolkata.- 1 Dismantling the existing damaged wiring, cables,switch board,fan,fittings and depositing the fan, fittings to the concerned authority, including mending good damages neatly. ( Dist. Wiring-940 pts,Cables-300 mtrs,SPNMCBDB-23 nos, HTPNMCBDB-6,100A TPNSFU-4 nos ) 2 Dismantling of old main panel and changeover panel after dis connection of existing cables with out any damage carefully and depositing it to the authority. 3 Sub-Station Master Panel : Specification of indoor type L.T. panel Board with ACB as Incomer, Buscoupler and MCCB as outgoing feeders in a suitable transportable unit, ready for operation on being installed in a fixed position. The Panel board shall be Self-supporting, Compartmentalized, Floor mounted, Indoor Type, Dust and vermin proof. Incoming and outgoing cable entry from Top at rear side. Gland plate should be two part detachable type. The Panel board shall be fabricated from 2mm thick (14 SWG) CRCA sheet and base channel will be 75mm x 40mm x 6mm, with MS angle re-enforced / stiffner of 50 mm x 50 mmx 6 mm for vertical and 40 mm x 40 mm x 6 mm for horizontal. Lifting hooks to be provided in each transportable unit. The doors shall be removable type mounted on hinge with key locking arrangement for each compartment. Doors shall be both on front and rear.Degree of protection of the board is IP43. 4 Painting : Board should be properly degreased, derusted before phospheting. Alkaline Melamine Epoxy based Powder coated paint to be done with minimum thickness of 70 micron avg. Shade will be Pebble Grey, No.RAL 7032 both inside and outside. Continious Earth bus of size 50 x 10 mm Cu to be provided at a hight of 200mm from the bottom and brought outside of the panel of 75mm. Depth of the panel : Breaker Panel minium 1100mm and other 750mm. CENTRAL POWER RESEARCH INSTITUTE type test report for the Panel Board for Three phase and Neutral short circuit withstand strength test on main circuit BusBars of HBB+VBB for 65kA rms for 1.0 second with intial peak of 143kA, 415V,AC, 4000A, to be Furnished. 5 Termination : Incoming cable termination Bus should be suitable for bus trunking system. Outgoing feeder terminals should be as per rating. 6 System Voltage : 415V, 50Hz, TPN.Control wiring cable size : minimum single core multistranded 1.5 sqmm PVC Cu flexible wire. (Mk. Finolex / Havells / Polycab)CT wiring cable size: 2.5sqmm flexible 7 INCOMING : a) S & F Air Circuit Breaker, suitable for 415V, 50Hz, 4P, 800A, EDO type, with LI protection (O/C, S/C, EF), along with Castle Key mechanical interlock & electrical interlock (A), (Make: L&T / Siemens / ABB / Schneider) -- 02 (Two) nos. (main incoming from 1250KVA transformer). 8 BUSBAR : Bus Bar Materials : Electrolytic Grade Copper, 90% pure in nature, Semi soft, Tinned electroplated with heat srinkable sleeve. Size of Bus Bar:Main Horizontal & Vertical Bus - 2 x 80 mm x 6 mm per phase & Neutral - suitable for 1200A. Feeder Connection :4 x 50 x 5mm for 415A, 4 x 40 x 5 for 315A. Rest of the connection by suitable size copper bar/cable.BUSCOUPLER :--a) S & F Air circuit Breaker, suitable for 415V, 50Hz, 4P, 800A, EDO type with LI protection (O/C, S/C, EF), along with Castle Key mechanical interlock & electrical interlock (Make: L&T / ABB / Siemens / Schneider) - 01 (One) no. 9 OUT GOING :a)S&F Microprocessor based 415V ,400A, 4P MCCB with Door drive assembly(suitable spreader terminal and rotary handle as required) (Mk. L&T / ABB / Siemens / Schneider) with adjustable LI protection - 2 (Two) Sets. (01 no in operation, 01 no Spare)b) S&F Microprocessor based 415V 315A 4P MCCB with Door drive assembly (suitable spreader terminal and rotary handle as required)(Mk. L&T / ABB / Siemens / Schneider) with adjustable LI protection - 01 (One) Sets.c) S&F Microprocessor based 415V 250A 4P MCCB with Door drive assembly(suitable spreader terminal and rotary handle as required) (Mk. L&T / ABB / Siemens / Schneider) with adjustable LI protection - 02 (Two) Sets. d) S&F Microprocessor based 415V 100A 4P MCCB with Door drive assembly(suitable spreader terminal and rotary handle as required) (Mk. L&T / ABB / Siemens / Schneider) with adjustable LI protection - 01 (One) Sets. c) S&F Microprocessor based 415V 63A 4P MCCB with Door drive assembly (suitable spreader terminal and rotary handle as required)(Mk. L&T / ABB / Siemens / Schneider) with adjustable LI protection - 04 (Four) Sets. 10 TERMINATION :-- All outgoing terminations are from the rear side of the panel. 11 CABLE ALLEY :Cable alleys on both sides for incoming of ACB interconnection 12 INTERCONNECTION :CT wiring by 2.5 sq mm, Metering circuit with 1.5 sq mm single core stranded FR PVC copper wire with proper copper socketing & taping. (Mk. RRKable / Havells / Polycab) 13 READING ARRANGEMENT :a) S & F 3 ph Commmunicable Multifunction Metering MFM (KWH, KW, KVA, V, I, F, PF) Device (Make- L&T, Cl. 1 WL501010OOOO) - 02 Sets. b) 800 A / 5A, 15VA, Cl. 1 CT Coil (Mk. AE) - 06 nos. c) LED type indicating lamp ( R ,Y, B, ON,OFF,TRIP indication for 2 nos. I/C and ON,OFF indication for 10 nos. O/G ) -32 nos g) 2A C curve MCB - 32 Nos(Prior approval must be taken from Accepting Authority regarding the drawing / design and specification of the panel with BOM before starting of construction of Panel) 14 5.6 Gr Stainless Steel Bolts & Nuts mus be used for all Bus Bar Connection in the total panel. Bus Bar Support Material : FRP (thickness minimum 10 mm for main bus) Acralyic Sheet / Backelite guard to be provided in front of Bus Alley / Back side of MCCB. 15 Supply, Delivery at site, installation, testing, and Commissioning of L.T. cubical type Indoor, single tier, fully compartmentalized, free standing, floor mounted distribution panel board, having rigid and self supporting structure fabricated with 14 SWG CRCA sheet.The base of panel being made with80mm x 40mm x 4 mm M.S. channel. Each compartment should be provided with hylam board at back side. Construction Details: All incoming & outgoing switches are to be housed in respective compartments with hinged and gasketted doors at the front having two blank compartments as future provision. All doors should have panel locking arrangement in such a fashion that it can not be switched ON unless the feeder remains in OFF position. The Cable entry should be made at the bottom of the panel and there should be Cable Alley at both sides as per approval of EIC. Neoprene or similar synthetic compounds, not subject to deterioration due to the climatic conditions, should be used for gaskets, sealing rings, diaphragms, etc. The complete panel board is to be painted (heat-chamber) after required surface treatment by 7 tanks process / sand blasting with 2 coat of red oxide primer & 2 coat of finishedpowder coated painting. (Panel should be built from CPRI approved manufacturerINCOMING:i) S & F 415V, 320A TPN on load front operatedchange over switch.-01 no (Make: L&T/ Schneider/ Siemens/ABB) 16 ii) S & F 415V, 415A, TPN TPN SFU with 3nos DIN type HRC fuse as per rattings- 1 nos.OUTGOING: i) S & F 415V, 315A, TPN TPN SFU with 3nos DIN type HRC fuse as per rattings- 2 no.ii)S & F 415V, 63A, TPN SFU with 3nos DIN type HRC fuse as per rattings- 3 Set BUSBAR & METERING: 415V, 600A capacity having Busbar of( 2 x 40 x 5)mm ----- 04 Nos.(The busbar shall be hard drawn high conductivity electrolytic grade copper(99.9% purity) flats conform to IS:5082 and uniform in X-Section fited on porcelain chair) (a) 230 V, R,Y,B LED indicator----- 01 Sets. (Make:L&T/Kaycee/Schneider/Siemens/ABB)(b) 3Ph. Digital Ammeter with selector switch (Make - L&T Model NOVA/similar of Schneider/Siemens/ABB) - 1 sets.(c) 3Ph. Digital Voltmeter with selector switch(Make - L&T Model NOVA/similar of Schneider/Siemens/ABB) - 01 sets.(d) 600/5 Amp C.T ( Kappa) - 03 nos. (e) Slide-lock fuse for instrumentation and indicator ckt on each phase--03 set(f) S & F EI danger board 15cm X10cm (6X4)on panel---01 Nos. (N.S) 5.6 Gr Stainless Steel Bolts & Nuts must be used for all Bus Bar Connection in the total panel. 17 Supplying and fixing 415V, 100 A TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.(Make-L&T/Siemens)( near rising main) ( For incoming of proposed Light VTPNMCBDB)( For Gr. floor to 4th floor) 18 Supplying and fixing 415V, 125 A TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.(Make-L&T/Siemens)(at rising main)( For incoming ofproposed A.C VTPNMCBDB)(for Ist floor to 4th floor) 19 Supply & Deliveryoffollowing 1.1KV gradeXLPE insulated Aluminium Ar. cable ( Make -Gloster/ RR cable/ Havells/ polycab) 20 4 core 16sqmm 21 4 core 25 sqmm 22 4 core 35sqmm 23 4 core 50sqmm 24 4 core 70 sqmm 25 4 core 95sqmm 26 4 core 150 sqmm 27 4 core 185 sqmm 28 Laying of followingcableson wall/surfaceincluding S & F MS saddleswith earthing attachment in10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting. 29 4 core 16 sqmm 30 4 core 25 sqmm 31 Laying of following cableson wall/surfaceincluding S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting. 32 4 core 35sqmm 33 4 core 50sqmm 34 Laying of following cableson wall/surfaceincluding S & F MS clamps with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting. 35 4 core 50sqmm 36 4 core 70 sqmm 37 4 core 95sqmm 38 4 core 150 sqmm 39 4 core 185 sqmm 40 Supplying and fixing 1.1 KV , 16 sqmm single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. (From existingRisingto proposed 100A TPN SFU ) 41 Supplying and fixing 1.1 KV , 35 sqmm single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. (From existingRisingto proposed 125A TPN SFU ) 42 Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc, incl. supplying sockets, tapes. 43 (a) 25 Sq.mm. 44 (b) 35 Sq.mm. 45 S & F 40mm heavy gauge Polythene flexible Pipe. 46 S & fixing double door 6 way Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (L&T/Siemens/ABB ) ( For light load) 47 Incoming -415V, 100A Four Pole MCCB -1 no (L&T/Siemens/ABB ) 48 Outgoing-63A TP MCB -5 nos.(L&T ),40 A SPMCB-3 (L&T/Siemens/ABB ) 49 S & fixing double door 8 way Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Legrand/L&T/Schneider ) ( For A.C load) 50 Incoming -415V, 125A Four Pole MCCB -1 no(Legrand/L&T/Schneider ) 51 Outgoing-63A TP MCB -7 nos.,40 A SPMCB-3 (Legrand/L&T/Schneider ) 52 S&F 415 V, 16-32A per way, 4 way Horizontal TPN MCBDB with SS enclosure, double door with IP 42/43 protectionconcealed in wall after wall cutting and mending good the damages to original finish incl. interconnection with suitable size of Cu wire, neutral link and earthing attachment.(Make -legrand //L&T/Schneider /ABB) 53 Incoming -FP MCB Isolator 63A-1. (Make -legrand //L&T/Schneider /ABB) 54 Outgoing :6 A -32 A SPMCB-12 nos.(Make -legrand //L&T/Schneider /ABB) 55 Supplying and fixing double-door(2+12 way) SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make -legrand/ Schneider /ABB) 56 Incomong -DP MCB Isolator 40A -1.(Make -legrand/ Schneider /ABB) 57 Outgoing 6 A -32 A SPMCB-12 nos(Make -legrand/ Schneider /ABB) 58 Supplying and fixing double-door(2+8 way) SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make -legrand/Schneider /ABB ) 59 Incomong -DP MCB Isolator 40A -1.(Make -legrand/Schneider /ABB ) 60 Outgoing 6 A -32 A SPMCB-8 nos(Make -legrand/Schneider /ABB ) 61 Supplying and fixing double door sheet steel(16SWG), powder coatedcable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachmentas to G.Sa) 6 way VTPN DB 62 b) 8 Way VTPN DB 63 Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded FRPVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit FR (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded FRPVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 3 no. “Ph, N & E” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending goodthe damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] [E15, 5]as to G.Sa) Average Run 8 mtr. 64 b) Average Run 10 mtr. 65 Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded FRPVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit FR (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded FRPVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with modular type switch fixed on modular type switch box on wall complete with 3 no. “Ph, N & E” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment, painting the MS box and mending goodthe damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] as to G.S Average Run 8 mtr. 66 Distn. wiring in 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC single core stranded FRPVC insulated & unsheathed copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish(On Board) 67 Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit FR (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. (On Board) 68 Supplying and Drawing 1.1 KVsingle core stranded FRPVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe/PVC rigid conduit and by the prelaid GI fish wire and making necy. connection as required as to G.S 69 a) 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) as ECC 70 b) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) as ECC For Power plug and Computer board15A plug. 71 c) 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC 72 d) 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) as ECC .(From TPN MCB DBto 2+12 way SPN MCB DB) . 73 e) 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) ECC (FromVTPNMCBDB to HTPNMCBDB ) 74 Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as to G.Sa) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) 75 b)2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) 76 c) 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) 77 d) 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) 78 Supplying and fixing compression type gland of PVC Al, Armoured cable complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry.as to G.Sa) 4 core 400 sqmm 79 b) 4 core 185 sqmm 80 c) 4 core 150 sqmm 81 d) 4 core 95 sqmm 82 e) 4 core 50 sqmm 83 f) 4 core 35 sqmm 84 g) 4 core 16 sqmm 85 Finishing the end of PVC Al, Armoured cable by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :a) 4 core 400 sqmm 86 b) 4 core 185 sqmm 87 c) 4 core 150 sqmm 88 d) 4 core 95 sqmm 89 e) 4 core 50 sqmm 90 e) 4 core 35 sqmm 91 f) 4 core 16 sqmm 92 Supplying and fixing 20 mm dia PVC Rigid Conduit FR [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works as to G.S 93 Supplying and fixing 25 mm dia PVC Rigid Conduit FR [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works as to G.S 94 Cutting channel of 40 mm x 40 mm size on masonry wall by electrical operated cutting machineincl. S&F heavy gauge 19 mm dia 3 mm thick polythene pipe without earth continuity wire, by means of anchoring chemical(Hilti/Sica) and GI U hook of 8SWG incl. supplying and drawing 18 SWG GI Wire asfish wire and mending good damages to original finish by using own tools and tackles. 95 Supply & Fixing 240 V, 6A, plug socket with separate 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex coverand making necessary connections as required. (Seperate 5 A Plug point) 96 Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required 97 Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required ( Computer Board) 98 Supply & Fixing 240 V, 3 nos. 6 A & 1 nos. 16 A5 pin Modular type plug socket with 3 nos. 6A & 1 no 16 A Modular type switch (Brand approved by EIC), on 2 row 12 Module GI Modular typeswitch board with 2 row 12 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire along with necessary copper made (Ph,N & E) bar.all are Schneider /Legrand make) [computer board] 99 Supply and Fixing 4 long Single LED tube light fittings (Philips Make, TMC 502 P 1xT-LED 22W complete with 1 no. MAS LED tube 1200mm 18W 865 T8 I-2100lm] equivalent to crompton/Wipro) suspended 25cm below the ceiling with 2Nos 20mm dia EI Conduit (14SWG) supports fixed with L type MS clamp whose one side fixed on ceiling after cutting the ceiling plaster with 4 Nos 40mm long GIfastner and another side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduitL type (50x125)mm, 6mm thick and 25mm with MS clampsand mending good damages to original finish and painting etc. by 2X24/0.20 mm (1.5 sqmm) flexible copper wire of 1.10 mt length. 100 Supply and Fixing 4 long double LED tube light fittings (Philips Make, TMC 502 P 2xT-LED 22W complete with 2 nos.MAS LED tube 1200mm 18W 865 T8 I-2100lm) equivalent to Crompton/Wipro) suspended 25cm below the ceiling with 2Nos 20mm dia EI Conduit (14SWG) supports fixed with L type MS clamp whose one side fixed on ceiling after cutting the ceiling plaster with 4 Nos 40mm long GIfastner and another side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduitL type (50x125)mm, 6mm thick and 25mm with MS clampsand mending good damages to original finish and painting etc. by 2X24/0.20 mm (1.5 sqmm) flexible copper wire of 1.10 mt length. 101 Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (for A.C) 102 Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. 103 Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. 104 Supply and fixing of Timer control unit for1 Ph AC machine with 12 way SPNDB Boxarrangement .( Make- L&T / Legrand/ ABB).a) 12 way SPNDB or timer DB-1nob)40A DPMCB isolator-1noc) Digital 24 hrs time switch-1 nod) 40A 2 pole power contractor-1 noe) Centre off 2-way toggle switch-1 no 32Af) Barrier type Terminal -1 no g) LED indicating lamp-2noH)2x4+1x2.5 sqmm cu wire ( Gloster/KEI/rr/kABEL) 105 Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/ perspex top cover by screw incl.making necy. connections etc 106 Supply anddelivery of 1200mm sweepA.C. Ceiling fan [Make- Crompton Aura Prime antidust/ Orient quasar ornamental/ eq. to Havells) 107 Fixing of ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire including Supply & fixing safety arrangement for AC Ceilling fan by stranded GI strain wire of suitable gauge with one end fixed at RC clamp with special type socket/nut bolts thimble which throughly crimped with the strain wire passing through the down rod and also other end connected with armature spindle by its existing jam nut hole with special arrangement (sample approved by EIC). The length of strain wire varies as per site situation also considering any type of work required i.e. enlarging the existing holes by file etc.to complete the job incl. installation as per direction of aEIC.(Test report of GI wire to be submitted)Safety feasibility to be checked by the EIC with its application. 108 Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt length. 109 Supply & installation of 230 volt,50 Hz, 450mm (18) sweep AC Pedstal fan with metal body & metal Blade (Make- Crompton,model-ACVORTEX18PF,100 watt,1440 RPM/equivalent of EPC/ALMONARD) as per direction of EIC 110 S&F of 250 V, 1420 rpm, 12 sweep AC Exhaust fan ( Heavy duty, make-EPC/equivalent to Crompton)after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection incl S & F GI louver shutter as per direction of E.I.C 111 Supplying & fixing Down rodfor suspension of Ceiling fans exceeding 30cm with S&F additional 1 no.20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 3x24/0.20 mm (1.5sqmm.)flexible copper wire of 1.10 mt. length. 112 Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991) (29,D-14) 113 Supplying and Fixing GI water proof looping cable box of size 250mm X 250mmX 100mmdeep on angle iron frame on wall having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, one NL on porcelain insulator, earthing terminal with lug etc. with arrangement for fixing compression type brass cable glandfor upto 4 core 25 sqmm XLPE insulated Aluminium armoured cable incl. painting with anticorrosive paint 114 Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers of 415V,100A ,4 bars having dimension of Al bars (25mm X 5 mm ) on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991)(Dimension of sheet metal box( 500mm x 500mmX150mm)). 115 Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers of 415V,315A ,4 bars having dimension of Al bars (50mm X 10 mm ) on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991)(Dimension of sheet metal box(500mmX 500mm X150mm)). 116 Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers of 415V,415A ,4 bars having dimension of Al bars (65mm X 13 mm ) on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991)(Dimension of sheet metal box( 500mm X500mm X150mm)). 117 Excavation of soft soil for installation of Earth Electrode and filling & ramming. 118 Earthing with 50 mm dia GI pipe3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level by ISI-Medium GI pipe. 119 Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. 120 Connecting the equipments body to earth busbar incl. S & F 25 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl. drilling holes, bolts, nuts,washers etc. 121 Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. 122 Dismantling the existing TPNDB, SPNDB and its cable, wires connection by agencies own tool and tackles and refixing the same in another position with all necessary connections as per direction of EIC 123 Hiring charge of appropriate size of bus bar & panel board with reqd size & length cables incl. all type of connection & dismantling temporarily as per requirement in actual for catering power supply in normal condition as far as possible during the work period (upto 3 days) as per direction of EIC. 124 Charges for hiring & running of 250 KVA Silent Movable Green DG set with suitable size Cu cable (4 Nos. Cable Length each 100 Mtr. Long - RYBN) incl connection at required point & with operator / guard for 24 hrs. (DG Set will be tested ON LOAD at least 80% of capacity before installation) (Oil consumption rate 30 Ltrs./Hr.) 125 Charges for diesel incl. carrying charge (carrying charge extra @ Rs. 1.00 pLtr. - carrying charge included storing container for oil) 126 Less cost of all dismantled items including unserviceable materials of existing pancels with different rated main switches and ACBs etc.

Key Value

Document Fees
Refer document
EMD
INR 125324.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail