| 1 | Part A : Electrical Istallation Works:Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded \"FRLSH\" PVC insulated & unsheathed copper wire (Polycab/Gloster/Havells) in 20mm size PVC rigid conduit \"FR\"(Precision/polycab make), with 1x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish |
| 2 | (Average run-8 Mtrs) |
| 3 | (Average run-9 Mtrs) |
| 4 | On Board |
| 5 | Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A plug socket with separate 2 nos. 6 A & 2 nos. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required |
| 6 | Supply & Fixing 240 V,2 nos 6A, plug socket with separate 2 nos 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 175x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. |
| 7 | Supply & Fixing 240 V, 2 nos 20A, plug socket with separate2 nos 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 200x150x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required |
| 8 | Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required |
| 9 | Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex coverand making necessary connections as required |
| 10 | Distribution wiring in 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed copper wirein 20mm size PVC rigid conduit \"FRLSH\" (Precision/Polycab make) incl. necy. fittings as required (Make- Gloster/Polycab/Havells) |
| 11 | a) 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) (for PDB to SPNDB) |
| 12 | b) 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) (for AC point & Combined power plug. ) |
| 13 | c) 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) (for power plug & Computer Board ) |
| 14 | d) 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) (for separate plug) |
| 15 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. |
| 16 | a) 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) (for PDB to SPNDB) |
| 17 | b) 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) (for AC point & Combined power plug. ) |
| 18 | c) 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) (for power plug & Computer Board ) |
| 19 | d) 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) (for separate plug) |
| 20 | Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board |
| 21 | Fixing of A.C timer D.B on wall by drilling hole into the wall & fixing the same by suitable size M.S fastner incl. mending good damages. |
| 22 | Supply & fixing of 230 V of digital timer switch (Make - L&K GIC Model no: 67DDT0) |
| 23 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. |
| 24 | Supply of 14 SWG MS downrod having drilled holes for housing nuts, bolts, washers & safety nuts as per direction of EIC for fixing ceiling fan at suitable position as mentioned below - |
| 25 | 2 ft |
| 26 | 3 ft |
| 27 | 5 ft |
| 28 | Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. |
| 29 | Supply & Fixing 240V., Industrial Plug and Socket Outlet having 32A Metal Plug & Socket (2P + E) with plug top and 1 no. 32 A. DP MCB, in SS enclosure complete with all accessories embedded in wall with earthing attachment. (Make: Legrand, Cat No 507863/ABB/L&K/ABB) |
| 30 | Supply & Delivery of 240V 3 pole contactor Make - L&K Model No - MNX 22 cat no - CS94980BOOO./ABB) |
| 31 | Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long) |
| 32 | 30 cm Exhaust fan (12\") |
| 33 | 38 cm Exhaust fan (15\") |
| 34 | Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required |
| 35 | 150 mm x 100 mm x 65 mm |
| 36 | 175 mm x 100 mm x 65 mm |
| 37 | 200 mm x 150 mm x 65 mm |
| 38 | Supply & Fixing 240 V 6 A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required |
| 39 | Supply & Fixing 240 V 16/20 A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required |
| 40 | Supply & Fixing 240 V, 6A plug socket (Brand approved by EIC), without switch & plug top, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for plug by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc. |
| 41 | Supply & Fixing 240 V, 20 A plug socket (Brand approved by EIC), without plug top and switch, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for combined plug switch by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc. |
| 42 | Supply & Fixing 240 V 6 A Modular type switch (Legrand/Anchor/ABB) on existing GI Modular type switch board having top cover plate and making necessary connections as required |
| 43 | Supply & Fixing 240 V 16 A Modular type switch ((Legrand/Anchor/ABB)) on GI Modular type switch board having top cover plate and making necessary connections as required |
| 44 | Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket ((Legrand/Anchor/ABB)), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 45 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket ((Legrand/Anchor/ABB)), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 46 | Supply & Fixing Socket type fan regulator (Step type) ((Legrand/Anchor/ABB)) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc. |
| 47 | Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) ((Legrand/Anchor/ABB)) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. |
| 48 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Legrand/Schneider) |
| 49 | 6-32 A SP |
| 50 | 20 A DP |
| 51 | 40 A DP |
| 52 | 63 A TP |
| 53 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. (Legrand) |
| 54 | 40A DP |
| 55 | 63A DP |
| 56 | 63 A FP |
| 57 | 80 A FP |
| 58 | 100 A FP |
| 59 | Supply & Fixing of 0 - 500 V range digital voltmeter (Make AE/L&T) in place of damaged one. |
| 60 | Supply & Fixing of 0 - 50 A range digital Ammeter (Make AE/L&T) in place of damaged one. |
| 61 | Fixing only fan clamp for RC ceiling as per specification after cutting the ceiling & binding with reinforcement and mending good the damages. (Ceiling fan are depatmentally supplied) |
| 62 | Supply & Fixing of 9\"\" Heavy Duty exaust fan with making hole complete with all accessorieshaving the following Model / Cat No.(Make -EPC Electrical Pvt. Ltd. )Speed 1420 RPM with Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long) |
| 63 | Supply & Fixing of 12\"\" Heavy Duty exaust fan with making hole complete with all accessorieshaving the following Model / Cat No.(Make -EPC Electrical Pvt. Ltd. )Speed 1420 RPM with Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long) |
| 64 | Supply & Fixing of 240 V., 1200 mm. Sweep, A.C. Ceiling Fan without Regulator, incl. Down Rod, Canopy, Fan Blades etc. and engraving & Painting the Departmental Number on Fan Body and interconnection complete in all respect.(Make:, Orient: Summer Cool/Usha Striker plus/CG HS Plus) |
| 65 | Supply & Fixing of 240 V., 900 mm. Sweep, A.C. Ceiling Fan without Regulator, incl. Down Rod, Canopy, Fan Blades etc. and engraving & Painting the Departmental Number on Fan Body and interconnection complete in all respect.(Make:Orient: Summer Cool/Usha Striker plus/CG HS Plus) |
| 66 | Supply & Fixing of 240 V., 450 mm.Dia (18\"), 3/4 (four) Blades Industrial type full metal body Wall Bracket fan complete with all accessories to be grouted on wall incl. making necessy. connection as per direction of EIC.(Make: EPC Electrical Pvt Lt/ Orient/Crompton) |
| 67 | Supplying and fixing 415 V Four Pole,160A MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection (Legrand). |
| 68 | Supply & Fixing 240 V, 25 A Modular starter (Brand approved by EIC) on 2 module GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc |
| 69 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wireetc. |
| 70 | S & F 250V 25A Timer controller for AC machine in SS double door 2+10-way DB enclosure (Make:- L&T, encloser cat no DBSPN012DD) or equvalant) with S&F following electrical accessories & front door locking arrangement with all connection by finishing the ends of 2x4 & 1x2.5 copper wire dowells solderless socket by crimping method as to GS earthing attachment on wall incl necessary connections as per direction of EIC :-i)10kA, C-Curve, 240V, 25A ,DPMCB (L&K/Schnider/ABB Elegance) --- 1 Noii) 24 Hr programmable Digital/Analog Timer (L&K make cat no 67DDT0) ---- 1 Noiii) 3 pole power contractor (L&K make cat no MNX 22/230V) with 1 NO +1 NC additional contact block ---- 1 setiv) 2 Moduler AC motor stater (Make:- Legrand/Myrius) ---- 1 No.v) 2 Module plate with cover (Make :-Legrand/Myrius) -- 1 Novi) 20A Auto-Off-Bipass SPDT toggle switch (Approved/reputed make) ---- 1 No.vii) 10A SPST Moduler typeswitch (Make :-Legrand/Myrius) - 1 No.viii)Outgoing connector make ELMAX (Approved/reputed make) - 1 No |
| 71 | Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make: L&K) |
| 72 | Supplying and fixing sheet steel (16SWG) cable end box on TPN SFU enclosure with nuts bolts etc incl. powder coated painting |
| 73 | Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – (As per Drawing no. 470 of PWD Specification Book – May 1991) |
| 74 | 415 V, 100/125 A Dimension of Cu. Bars 4 x 15x3mm Dimension ofSheet Metal Box 500x150mm |
| 75 | Part B : Comound Illumination & Cabling Works:S & F Of 240 Volt,150W LED street light(Philips Cat no -BRP334LED144CWR5CF6PSUS1V1/ equivalent of Osram or GE Lighting) in place of damaged one as per direction of EIC. |
| 76 | S & Delivery of 1.1 KV grade PVC Al/Armoured Cable (Make- Gloster/Havells/Polycab) in UG Trench as to GS |
| 77 | For 4 core 35 sqmm |
| 78 | Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed |
| 79 | Laying of cable upto 3/4 core 35 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages andpainting |
| 80 | Supplying and fixing compression type gland complete with brassgland, brass ring & rubber ring for dust & moisture-proof entry ofXLPE/PVC armoured cables as below : |
| 81 | For 4 core upto 35 sqmm |
| 82 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : |
| 83 | For 4 core upto 35 sqmm |
| 84 | S & Delivery of 1.1 KV grade PVC Al/Armoured Cable (Make- Gloster/Polycab/Havells) in UG Trench as to GS |
| 85 | 4 core 10 sqmm |
| 86 | 3 core 6 sqmm |
| 87 | Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting. |
| 88 | Supplying and fixing compression type gland complete with brassgland, brass ring & rubber ring for dust & moisture-proof entry ofXLPE/PVC armoured cables as below : |
| 89 | 4 core upto 10 sqmm |
| 90 | 3 core 6 sqmm |
| 91 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : |
| 92 | 4 core upto 10 sqmm |
| 93 | 3 core 6 sqmm |
| 94 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium/Tata) Protection with necessary fittings and jointing metarials as required (Cable Protection) |
| 95 | 50 mm dia |
| 96 | Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting. |
| 97 | (a) 200 x 150 x 100mm |
| 98 | Part C : LED Sign Board Repairing Works: Repair of glowsign board by using of imported 12 V DC LED modules having three LED in a single base module and the LEDs will emit mild attractive blue / white colour light and the two run of LED for each letter base area and shall be properly fixed in the male part of the Acrylic letters including necessary interconnections using soldering and heat sink. |
| 99 | Specification of the LEDs is given as below :a) LED - White / Blue, GE / Samsung (Cat. No. Tetra mini max, Code No. GEWHMMTS8) Vinb) Type - Straight, 3 Nos. Led per modulec) Life - 70,000 burning hours.d) Visibility - 100 mtrs at least, for normal eyee) Power supply - 20 Amp. (GE / VIN)f) Power consumption - 1.5 watt per moduleg) Input - 230V, AC output 12V DC (Double Led layer) |
| 100 | Thorough washing & cleaning of glowsign board after opening all the letters and refixing the same with silicone to prevent water and insects. |
| 101 | S & F of imported heavy duty IP 65/66,12 V DC, 600 Watt SMPS (Make - Approved by EIC) in suitable enclosure to be fixed in the signage frame for driving total LED system of the signage in a distributed manner for uniform load sharing (parallel connection) in view of long run continuous use.(make- Samsung/Nicha/Cray/Osram) |
| 102 | Supply & interconnections with soldering covered by heating tube each wire end. (Make : - Gloster / Havells / Polycab). |
| 103 | 2 x 22/0.3 (1.5 sqmm) cu. wire. |
| 104 | Finishing of the PVC insulated wire ends by socketting with pin / ring / split type copper sockets and insulated tapes etc., including supplying sockets, tapes.(make Dowells /Arun) |
| 105 | 2 x 22/0.3 (1.5 sqmm) |
| 106 | Scaffolding arrangement for working at different level height of the road-side gate by making suitable heavy type scaffolding (size 65\" wide x 25\" height) by bamboo, ropes and wooden planks etc. to be provided for as per direction of the EIC. |
| 107 | TERMS & CONDITIONS :-The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/ submission of bill.If any refurbished material is supplied and installed, penal action will be taken as per existing rules.As per requirement of worksite, part layout would be given & work has to be taken up within 24 (twenty four) hours of layout & completed as per site requirement for smooth patient care service. |
| 108 | Defect Liabibility Period 1 (One) year |
| 109 | Make & model of each and every material to be approved by EIC |