Supply, delivery & installation of various electro mechanical accessories for repairing & rejuvenation of damaged electro-mechanical equipment at pump house no.-1 of Jamboni w/s scheme of Paschim Medinipur Dist. under Jhargram Mechanical Division P.H.E Dte.- 1 102 mm. dia 0-10 kg/cm² range wall mounted bourden type pressure gauge complete for tubewell outside the pump house including brass cock & fittings.Make :-As per approved vendor list of PHED vide no. 2783/79/F/2018 dated 25.03.2025 with latest amendments. 2 102 mm. dia. wall mountedbourden type depth gauge with suitable dia. and length of steel air pipe with all fittings including supply of one good quality Hand pump for tubewell outside the pump house. (This cost includes 15 mm. dia. G.I. pipe approx. 90 ft. length and specials)Make :-As per approved vendor list of PHED vide no. 2783/79/F/2018 dated 25.03.2025 with latest amendments. 3 Anti-snapping safety device for above pump by supplying1 dia. Nylone rope of required length (double) including supply of all necessary materials as required. 4 M.S suspention clamp with necessery nuts,bolts & washeretcsuitablefor 80 mm dia pipe( Size 500 mm X 80 mm X 8 mm each) 5 80 mm dia, P.N. 1.0, CIDF Non return valve conforming to IS: 5312, part-I. Make :-As per approved vendor list of PHED vide no. 2783/79/F/2018 dated 25.03.2025 with latest amendments. 6 80 mm dia, PN-1.0, CIDF sluice valveconforming to IS:14846. Make :-As per approved vendor list of PHED vide no. 2783/79/F/2018 dated 25.03.2025 with latest amendments. 7 80 mm dia, (PN-1.0) CIDF, wafer type butterfly Valve operated by three phase actuator conforming to IS:13095/1991 having IP 68 protection.Make :-As per approved vendor list of PHED vide no. 2783/79/F/2018 dated 25.03.2025 with latest amendments. 8 80 mm dia heavy type suitable length CI/MS Black pipes (for delivery header,backwash line for pump along with necessary bends, specials, fittings , viz flanges, bolts, nuts, gaskets, concentric enlarger , MS dismenteling joint, for connecting main pipe line etc. including providing MS/Bricks/PCC support for laying of pipes, valves as required to make the installation complete. (This includes the cost of supply, delivery of common header & short piece of required length to connect the delivery pipe line) 9 1.1 KV Grade 415 V, 4 core 16 sq.mm. PVC sheathed XLPE insulated Al. armoured cable conforming to IS:7098 (PART-1) 2011 with latest amendmends as applicable.Make :-As per approved vendor list of PHED vide no. 2783/79/F/2018 dated 25.03.2025 with latest amendments. 10 1.1 KV grade, 12 core, 1.5 sq. mm. Copper Control Cables, Solid Copper Conductor & Balance Stranded Copper, XLPE Insulated PVC Innersheathed, Armoured exruded PVC Type ST2 Sheathed as per IS 7098 (Part 1) 1988. (For actuator connection from panel)Make :-As per approved vendor list of PHED vide no. 2783/79/F/2018 dated 25.03.2025 with latest amendments. 11 415 V, Three phase PLC Panel with minimum 2mm thickness and degree of protection IP-54, conforming to IS-8623 with suitable Bus bar, Digital Voltmeter Ammeter,Contactor, delay timer, MCB, Valve Actuator starter etc. with PLC Logic & UPS .i) 5 - 7.5 HP DOL (Drawing & Bill of material shall be approved by E.I.C)Make :-As per approved vendor list of PHED vide no. 2783/79/F/2018 dated 25.03.2025 with latest amendments.SPEC: As per Specification attached 12 15 KVA, 3 phase oil cooling typeservo motor operated Voltage Stabilizer, having unbalance 200 - 500 V input voltage, and 415(±1%) output voltage , Auto/manual servo voltage stabilizer with U/V,O/V,O/L protection with MCB at output side, input MCCB, Ammeter etc. as per I.E rules and as per instruction of EIC.Make :-As per approved vendor list of PHED vide no. 2783/79/F/2018 dated 25.03.2025 with latest amendments. 13 Hard wooden board (450mm X 304.8 mmx 25 mm thick) 14 63 Amp, 240/415 V Porcelain fuse unit (Base & Bridge)Make :-As per approved vendor list of PHED vide no. 2783/79/F/2018 dated 25.03.2025 with latest amendments. 15 63 Amps, 415 V,ICTPN (Iron Claded Triple Pole Neutral) main switch in sheet steel enclosure having rewireable type fuse grip.Make :-As per approved vendor list of PHED vide no. 2783/79/F/2018 dated 25.03.2025 with latest amendments. 16 63 Amps, 415 V Bus-Bar chamber having 4 nos. copper Bar. Make :-As per approved vendor list of PHED vide no. 2783/79/F/2018 dated 25.03.2025 with latest amendments. 17 63 Amp, 4 pole on load change over switch Make :-As per approved vendor list of PHED vide no. 2783/79/F/2018 dated 25.03.2025 with latest amendments. 18 6-32 Amp,10 kA, 240/415V, 50 Hz SP MCB conforming to IS / IEC: 60898-1, C characteristics. (10 Amp- 1 no.,16 Amp-1 no., 6 Amp- 4 nos.) Make :-As per approved vendor list of PHED vide no. 2783/79/F/2018 dated 25.03.2025 with latest amendments. 19 8 way SP&N Double Door horizontal Distribution Board (I/C 2 + O/C 6) conforming to IS 13032 & IS 8623 and IP42/43. Make :-As per approved vendor list of PHED vide no. 2783/79/F/2018 dated 25.03.2025 with latest amendments. 20 LED street light luminarie IP 66 LM6-HPDC Housing Street light aerodynamically designed with better thermal management/ Potted driver is to be provided,the luminaire and housing should be from the same manufacturer(cat no- BRP052 LED 045 CW SLMR FG S1 PSU GR ,System Efficacy greaterthan 100 lumen/watt) Make-Philips OR Equivalent and same techinal specification ofHavells.The manufacturer has to provide LM79/LM80 reports corresponding to the luminaire/LED Chip along with type test Certificate.Respectively the luminaire manufacturer should have an in house NABL Accredited testing facility. 21 Installation of the above supplied itemInstallation, testing & commisioning of above supplied MCC, voltage stabiliser, valves & others items(item no 1 to 8, 11 to 20) by jointing submersible cable within the tubewell situated outside the pump house by making derrick arrangement by assembling the column pipes properly and fitting, fixing the pressure gauge, depth gauge, air pipe etc. in position and erection of delivery line & wash out line with the C.I specials and Tee including mending damages goods etc.all complete as per direction. This also includes the charges for laying submersible cable, control cablefrom tubewell & actuator to control panel respectively by underground trench, saddle on wall, through G.I. pipe and connection with required feeder of panel all complete. 22 Supply and installation of 2 mm thick, powder coated anticorosive painted G.I.Fabricated outdoor mounted kenopy type Cable Jointing Box having four legs and six nos. 100 Amps Al Bus bar, hinje type front having IP 55 protection &locking arrangement as per direction of E I C . 23 Dismantling the existing delivery line, valves & realigning the delivery line to minimize the loss of head with necessary backwash arrangement by fitting fixing the sluice valve & mending the damages of pump house wall with brick works, plastering & painting all complete as per direction. 24 Making suitable size pump foundation base ( Size: 1.00 mtr. x 1.00 mtr. x 1.5 mtr.) with supplying cement, sand, stone chips etc. in the portion of (4:2:1) including plastering, neat cement finishing including painting etc. all Complete as per direction of EIC. (i) Tubewell outside pump house 25 Making required nos. of brick pillar 0.25 mtr. X 0.25 mtr. For supporting of valves, actuator and pipes with 12 mm thick plaster and net cement finish including painting all complete as per direction of E.I.C 26 S&F of 3 dia 1.5 mt minipole with baseplate to be fixed on rooftop incl. S&F of 1.5 mtr long arm bracket (removable type) incl. CC (6:3:1) muffing(450X450X600) with 3 mm thick neat cement finish & painting incl. S&F of 200x150x100 mm 16 SWG GI loop box with necessary power connection by3x 22/0.3 (1.5 Sq.mm) (2 nos. P&N and 1 no. ECC) FRLSH PVC insulated & unsheathed copper wire (Approved make) in 20 mm size PVC rigid conduit FRLSH (Precision make) incl. necy. fittings as required as per direction of EIC. 27 Laying of cable (as in item no. 13) on wall/surface incl. S & F of MS saddles with earthing attachment in 10 SWG GI (Hot Dip) wire, making holes etc. as necy. mending good damages and painting all complete as per direction of E.I.C. 28 Supplying and fixing of compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry ofcable (as in item no. 9) all complete as per direction of E.I.C. 29 Finishing the end of cable (as in item no. 9) by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materialsall complete as per direction of E.I.C. 30 Making internal wiring/electrification of the Pump house by (2x 22/0.3 (1.5 sqmm) + 1x 22/0.3 (1.5 sqmm) single core PVC insulated multistrand FRLSH Grade flexible copper wire through 20 mm PVC conduit pipe/casing by supplying one no. 40 Amp, 10kA, 240/415V,50 HzSPN/DP MCB Isolator conforming to IS / IEC: 60947-3, C characteristics. (As per approved vendor list of PHED vide no. PHE/IV/2277/W-181/19 dated 25.09.2019) with required module PVC Board & piano key type switch. (ave. run 6 mtr). i) LED Tube set point-2 nos., Bulk Head light point- 1 no., 5 pin 6 Amps. Plug point- 1 no., 16 Amp socket & switch- 1 no, indicator- 1 no. each,with necy. earthing arrangement & one fan point (Total point 6 nos. points) including drawing power by suitable gauge (2.5 mm2) of copper wire from installed cut-out to SPN/DP MCB within DB through 20 mm PVC casing capping (precision make) as per direction of EIC (fittings should be of Philips make & wiring should be with continuous earthing arrangement and 20W two nos. 4 ft long LED tube light setsPHILIPS Astra Line, one no. bulk head (Endura WT202W LED6S NW PSU S2 PC), one no. 0-4 step fan regulator (Humfree), fittings etc to be supplied by agency). 31 Earthing with 50 mm diameter G.I. pipe 3.64 mm thick x 3Mtr. (10ft.) long and 1 x 4 SWG G.I. wire (4Mtr.long) 13 mm diameter x 80mm (3inch) long G.I. Bolts, double nuts, washer including S & F of 15mm diameter G.I. pipe protection (1 Mtr. Long) to be filled with bitumen partly below ground level to an average depth of 3.65Mtr.(12ft.) below the ground level and restoring the surface duly rammed.i) For soft soil by ISI Medium GI pipe. 32 Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 36.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm diaholes on the GI pipe. 33 Extra for treatment of soil by salt and charcoal coke for pipe electrode. 34 Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.Length of busbar is 0.5 mtr. 35 Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. 36 Supply, delivery and fitting-fixing of 230 volt1200 mm sweep AC ceiling fan withball bearing complete with all accessories such as blade, canopy, fork, down rod etc. Make :-As per approved vendor list of PHED vide no. 2783/79/F/2018 dated 25.03.2025 with latest amendments. 37 Add GST @ 18 % 38 Add Cess @ 1 %