| 1 | Earth work in Surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan lncluding getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. (All kinds of soil)( DAR.No-2.1.1, (Rs-102.57) |
| 2 | Providing and laying in Position Cement Concrete of l 1:5:10 (1 cement, 5 Coarse sand (Zone-lll) Derived from natural Sources : 10 graded Stone aggregate 40 mm nomical size Derived from natural Sources ) DAR N0-4.1.10, (Rs-5149.38) |
| 3 | Brick work with Common burnt clay F.P.S.(Non Modular ) bricks of Class- designation 7.5 in foundation and plinth in 1:4 Cement and Coarse sand of Mortar in including Supply of all materials labour T& etc required for proper completion of work as per DAR.No-6.1.1, (Rs-5822.46) |
| 4 | Brick work with Common burnt clay F.P.S. (Non Modular ) bricks of Class designation 7.5 in Superstructure above plinth level up to floor V level in all shapes and size in Cement Mortar 1:4 Cement and Coarse sand in including Supply of all materials labour T& etc required for proper completion of work as per DAR.No-6.4.1, (Rs-7381.59) |
| 5 | 12 mm thick Cement Plaster with Cement mortar in proportion of mix 1:4 (1 cement : 4 coarse sand). DAR-13.4.1, (Rs-282.29) |
| 6 | Centering and shuttring including strutting, Propping etc. and removal of from for suspended floors, roofs, landings, balconies and access platform. DAR-5.9.3,(Rs-732.48) |
| 7 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). DAR-5.3, Rs-9088.80 |
| 8 | Steel reinforcement for R.C.C. workincluding Straightening, Cutting, Bending, Placing in position and binding all Complete upto Plinth Level. Themo-Mechanicaily Trated Bars of grade Fe-500D or more.DAR-5.22C.1, (Rs-78.71) |
| 9 | Providing and Fixing 12.5 mm thick Tapered edge Gypsum moisture resistant Board False Ceilingwith Steel Section and Perameter Channal and Hungers Fixereshorizental level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main \"T\" runner suitably spaced at joints to get required length etc. Complete as Per Direction of Engineer in Charge. DAR-12.45.3, |
| 10 | Supply and Fixing of PVC wall Panel approved make, including supply of all material & labour and T & P etc. requird for proper completion of work. Rs-950 |
| 11 | DismantlingDoors, windows and clerestory window (Steel or Wood) shutterincluding chaukhat, architrave, holdfast etc. complete and stacking within 50 meters lead of area 3 sqm and below. DAR.No-15.12.1, (Rs-290.07) |
| 12 | Providing wood work in frame of doors, window, clerestory window and other frames,wrought framed and fixed in posotion with hold fast lugs or with dash fasteneres of reqiured dia & lenght (hold fast lugs or dash fastener shall be paid of separately.(Sal wood,DAR-9.1.2, (Rs-92045.56) |
| 13 | Providing and fixing wire gauge shutter using galvanized M.S. wire guage of average width of aperture 1.4 mm in both directions with wire of dia 0.63, for doors, window and clerestory windows with hinges and necessary screws : 35, mm thick Shutter with ISI marked M.S. Pressed butt hinges bright finished of required Size Second class teak wood Jali Door . DAR No-9.27.1.1, (Rs-3833.08) |
| 14 | Supply and fixing of Stenless Steel Door And Window Fittings as Sliding Bolt, Tower Bolt, Handels etc. Complete as Direction of i/c.(Rs-667) |
| 15 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/ coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/ to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 Note:- Structural design proof checked from a Government Engineering Institute, to be provided shall be paid separately. by the manufacturer for : (i) Sites with basic wind speed > 45 m/sec as per IS 875 – Part 3 (ii) Sites with structure height more than 20m for all wind speeds Using R2 series with frame (70mm & above) x (40mm & above) & Glazed sash (25mm & above) x (50mm & above) with zinc alloy (zamak powder coated touch locks with hook (Height upto 1.2 metre).Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R2 series with frame (70mm & above) x (40mm & above) & both glazed and fly screen sash (25mm & above) x (50mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height upto 1.2 metre). As DSR -9.147.A4.1, (Rs-8684.38) |
| 16 | 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. DAR-11.4. Rs-772.93 |
| 17 | Providing and laying in Position Cement Concrete of Specified Grade excluding the cost of Centering and shuttering all work up to plinth level 1:6:12 (1 cement, 6 Coarse sand (Zone-lll) 12 graded Brick aggregate 20 mm nomical size) SI.No-273. (Rs-4553) |
| 18 | Providing and laying Rectifited Glazed Ceramic floor tiles of Size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, ln colour White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with Grey cement Slurry @3.3kg/Sqm including Grouting the Joints with and matching pigment etc., complete. (DAR-11.39) (Rs-1050.63) (Endura Tiles) |
| 19 | Providing and Fixing of aluminium work for doors, window, Ventilators and Partitions with extruded built up standard tubular sections appropriate Z sections and other sections of approved make conforming to IS:733 and ISl;1285, Fixing with dash fasteners of required dia and size, including necessary filling up the gape at junctions, i.e. at top, bottom and sides with required EPDM rubber/neorapan gascket etc. aluminium section shall be smooth rust free straight mistred and jointed machanically whrever required including clear angle, aluminium snap beading for glazing/Paneling, C.P. Brass/Stainless Steel Screws, all complete as per architectural Drawing and the directions of Engineer-in-charge. (Glazing, Paneling and dash fasteners to be Paid for Separately) (For Fixed Portion) Anodised aluminium (anodised transparent of dyed to required shade according to IS 1868 minimum anodic coating of grade AC 15)DAR-21.1.1.1, (Rs-391.06) |
| 20 | Providing And Fixing Float Glass Panes 4.0 mm thick(Weight not less than 10.00 kg/Sqm), (DAR-9.7.7.1) (Rs-1770.91) |
| 21 | Providing and Fixing of glazing in Aluminium door/ window, Ventilator shutter and Partitions etc. with EPDM Rubber/neoprene gasket etc. complete as per the architectural drawings and the direction of Engineer-in-Charge. (Cost of aluminium Snap beading shall be paid in basic item). with APC Sheet (Aluminium Power Coated Sheet). (Rs-1134) |
| 22 | Providing and laying Vitrified floor Tile Size of600x600 mm in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved Make, in all colours & shades, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Jointing with grey Cement Slurry @ 3.3 kg/Sqm including grouting the joint with white cement and matching Pigments etc. Complete.. (DAR-11.41.2) (Rs-1227.15) |
| 23 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. DAR No-15.60, |