Providing, Installation of DUAL AC/DC/Hybrid Borewell With 300 mm Dia Machine BoreWell With 200 mm Casing Tube Well Under Production of Designer Plants for Promotionof High-Density Plantation and Rejuvenation of Orchards (HADP) At FOA Wadura, SKUAST-K.- 1 Transportation of boring equipment to site incl. all sorts of carriage etc for casing pipes, GI pipes, transpormer etc. Complete in all respects. 2 Drilling of 300 MM dia machine bore bit cost excluding casing pipe 200 MM The well is to be developed using compressed air from an Air Compressor of adequate capacity and pressure rating. As the water becomes clear, surging or backwashing is done to make the development more perfect. The final discharge should be free from sand. The physical chemical analysis of water sample tested has to be as per the specified IS codes. After completion of development the well is tested for its performance that is yield characteristics and efficiency. The water has to be disinfected after completion of test for yield to ensure that the quality of water and as laid down as per specified IS standards. The grouting and sealing of tube well has to be done to ensure safe sanitary conditions Conducting / arranging Geo-hydrological/Geo-physical ground water investigation survey for location of bore well .All expenses involved for getting done the Geo-hydrological/Geo-physical ground water investigation survey are to be borne by the contractor.Including successful commissioning of bore well. 3 Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketedplain ended casing pipes of 200mm nominal size dia having minimum wall thickness 7.1 mm Heavy Grade marked as H , conforming to IS 3589 of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, as per relavant IS , including required hire & labour charges, fittings & accessories, all complete, for all depths. Note: The pipe shall be of TATA/JINDAL/ESSAR make.The work also inclusive the cost of welding charges and welding rod of approved IS code required for complete execution of the work mentioned in the Item. 4 Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.The Gravel should be Pea gravel which is used in bore well gravel packing works.Development of bore well with compressor till sand free water is available, including all sorts of labour charges as required at site for completion of bore well. 5 P/f of 200 mm Shoe 6 P/f of HP submersible motor 15 hp Stage 8-10 Make Kirloskar or equivalent. Complete in all respects with pump section etc and. Etc 300 LPM Outlet size80mm 7 Providing of submersible 10 sq mm flat cable copper Havels 3 core 8 GI pipe C type with flange after every 10 ft length with welding etc with 4 lengths having perforation standard Dia 3 /80mm with Heavy Make Jindal /Prakash Surya 9 Bend / elbow GI 80/100 mm complete 10 Supplying, installation, testing & commissioning of 20 KWcopper wound servo voltage stabilizer with following specification:1. No. ofinput phases :Three2. Frequency : 50HZ ± 3%3. Capacity : 20 KWfitted with Voltmeter 0-50 (2-Nos) AE make with roter switch, RYB indication primary and secondary brass terminals with oil 4. Input voltage: 90--2005. Output: 220—200 PN, 400-440V P-P6. Oil Immersed with oil topping completeMake Chinar /Equivalent 11 MCCB 100 AMake 4 pole 36 KA Hager /Legrand 12 S/I of Changeover , Panel Mounted Standard Make 100 Amp TPN 13 Supply installation testing and commissioning of star delta starter 30 HP rangewith features as below:MUG25 S Heavy duty or equivalent 1. Fully - Automatic type3. Under voltage protection4. Thermal overload protection5. Single phase preventor protection Kilburn/Equivalent/L&T 8. Overload /under load protectionThe job includes mounting of starter on underneath panel boardComplete with internal and external connections etc, Duly tested on load. MakeBentex / Kilburn / L&T CS91533CNFO 42A 14 Fabrication, supply, installation, testing & commissioning of intdoor type compartmentalized feeder pillar having front area not less than 0.60 Sqmtr 900 mm x 900 mm) and depth 30 Cm (NS)made out of 2mm thick CRCA sheet having separate cable and bus bar alley, 1 door arrangement i/c locking arrangement, having 200 Amp four polealuminium bus bar of full length with base frame made out of50mmx50mmx6mm (thick)angle iron having 80cm legs for erection in ground with construction of cement concretesuitable foundationsizecomplete with connections and interconnections with copper conductor PVC insulated cables/ insulated aluminium busbar strips of appropriate size and terminal blocks (on outgoing) including supplying & fixing following switchgears & accessories there in, powder coating, labelling, earthing etc. complete as required. Providing and fixing following accessories in existing cubical panel board i/c making connection etc. as reqd. Providing and fixing following accessories in existing cubical panel board i/c making connection etc. as reqd. with single phase preventer and MCB 100 A 4 Pole = 1 Nowith high cut and low cut protection. 15 Cable 10SQ mmfor star to delta connection 16 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. DSR CODE 7.3.1 for 35 Sq mm 17 Supply , laying of 1100 Vcore3.5 C 35 AYY XLPE 1100VXLPE un-armored cable in ground etc 18 Earthing with GIearth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. With GI strip 25x5 mm etc . Complete in all respects 19 GI Nuts and bolts of size 80 MM with gas cut washers as required 20 Flat Iron Clamps of size 80 mm 21 Threading of GI pipes for delivery section and cutting etc 22 32 mm PVC conduit 23 20 mm flexible conduit 24 Solar part 25 SITC of Solar Panel 390 watt or greater MONO Perc = 15 KW (500Wx30) with 72 Cells & should have a 25 years of warranty MNRE approved. Solar PV Module /ALMM approved. Warranty for Pump 2 years , Structure 1 year ,Make Sunlight Infra Energy Pvt Ltd. or equivalent SITC VFD /inverter / starter /Converter / All in One SolutionShould be Approved by MNRE, & Tested by Govt Approved Solar testing Lab & test Certificates should be Enclosedsuitable for 15 HP and covered in MS fabricated outdoor type panel . Dual Operation with Solar & AC power supply. Galvanized AL Structure with fasterners 6 MM - SS Farstener with two Washers with 25 x 3 GI Strip for Structure Earthing GI Earthing Strip (AC+DC+LA) with complete earthing works pit , PVC cover, Chemical 2 Mtr Long electrodeetcstructure to bear 150 Km/Hr wind velocity .with cement concrete block as design approved.Complete work in al respects. Min clearance height 1.5Mtr above ground. 26 17.2 MM Dia, 3 M Long, CU Plated, Chemical Earthing 27 1Cx 4 sq.mm 1.1 kVSolar PV cable (R+B) 4 SQmm DC Solar cable for Module/SJB/AJB/ Inverter/Polycab /Havells /Finolex 28 MC4 Connector Pair (Male, Female,Pins) - Suitable for 4 Sq.mm for connecting string 29 Main Junction Box 30 S/I of 25 sq mm PVC conduit 31 S/I of flexible PVC pipe 25 sq mm 32 S/I of DC trip and short circuit protection digital type for AC DB DC protection. 33 S/I of MCB TP 40/32 A 34 S/I of Copper lugs for 6 sq mm cables 35 Fabrication of Shelter forStabilizer, Control Panel of size 10x10 ftx 8 ftfabricated in Angle iron 50x50x5 mmwith GI roofing etc , Cement concrete Platformabove ground 12 inches , complete work in all respects . 36 S/I of HDPE/PPR PVC Casing pipe 200 MM Grade Heavy –H with sockets etc as needed at site . 37 S/I of HDPE /PPR PVC pipe (Heavy ) 80 mm nominal size dia having minimum wall thickness Heavy Grade marked as H 38 S/I of anchor /tie wire as needed at site 39 Note:-The rates quoted are inclusive of all carriages of materials (Mechanical/Manual) from source to site workand all extra charges including dewatering if any during the execution of work till complete in all respects.