Tender For Misc. Electrical And Panel Work At Govt. Engineering College Barmer - SITC of wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel made out of CRCA sheet , required hardware,duly treated for derusting in 7 tank process with dephosphating and with powder coating on both side of panel in desired shadeThe panel having PU/ Neoprene rubber gasket of not less than 3mm thickness , separate detachable gland plate M.S. base channel ,hinged door with locking arrangement for equipment/switchgear. Thickness of sheet shallnot be less than 1.6 mm up to 600 mm length / widthof any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall beof 2.0 mmthick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors with / withoutdetachable extension type structure. (only outer area on all sides shall be measured & panel to be fabricated from CPRI approved fabricator) 2 Supplying and fixing of Aluminium / Copper bus barby means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. 3 Electrolytic grade Aluminium bus bar 4 SF ofCurrent Transformer, with all necessary support in existing panel including connection etc. as required . 5 from 200 / 5 to 400/5Ratio , 10 VA , class 0.5 accuracy 6 from 500 / 5 to 1600/5 Ratio , 15 VA ,class 0.5 accuracy 7 SF of110/220 V, LED (22.5 mm dia ) Indicatinglamp with integral circuit, terminal block, including connection etc. as required. 8 Red/yellow/Green colour 9 Blue colour 10 P & F of Multy functionmeter with LCD/ LED display capable of measuringelectrical parameters like V, I, F, PF, KW, Kva, Kvar, Kwh, Kvah, Kvarh display with 1A/5A CT input for LV/ HV network, RS 485 communication port etc. complete in all respect. 11 SITC of quick make and quick break4 POLEcurrent limiting MCCB having following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip ,earth fault trip, push( test) to trip , including making connections with lugs & spreaders,etc. as required. 12 With Thermal Magnetic release 13 up to 125 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu 14 160 Amp, 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu 15 200 Amp ,25/35kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu 16 250 Amp , 35 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu 17 400 Amp ,35 kA, adjustable O/L & adjustable S/C setting, Ics = 100 % Icu 18 630 Amp , 35/50 kA, adjustable O/L & adjustable S/C setting, Ics = 100 % Icu 19 SITC of quick make and quick break3 pole current limiting MCCB having following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings and conforming to IS 60947-2 / IEC 60947-2 with frontface and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR , shunt trip , earth fault trip, push( test) to trip, including making connections with lugs & spreaders,etc. as required. 20 With Thermal Magnetic release 21 up to 100 Amp , 16 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu 22 up to 125 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu 23 160 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 % Icu 24 P&F metal clad industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in sheet steel enclosure (without MCB) including making connections, testing etc.as required 25 Three / Four pole (Five pin) 26 30A-32A 27 P/Laying P.V.C./ XLPE insulated & P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I / IS :7098 P - I of Group 1 of approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,IInd class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 28 10.0 Sq.mm 29 2 core 30 P&F of thermoplastic/ PVC cable junction boxes of following sizes including clamps for holding the box, cost of DIN rail for MCB mounting, connectors for cables terminals,threaded cable glands made of polyamide material etc. complete in all respect. 31 175mm X 150mm X100mm 32 S & F of Street light bracket made out from following size of B class GI pipe with heavy duty pole clamp, Saddles suitable fastners etc. as required. 33 40 mm Dia. 34 Supply & Installation of TAP Off unit enclosure (w/o MCCB / ACB ) of following capacityMCCB / ACB & suitable forsandwich typeAluminiumbus trunkingas required. 35 160 Amp.to 250 Amp. MCCB 36 300 Amp.to 400 Amp. MCCB 37 Supply & Installation of End Feed unit enclosure (w/o MCCB / ACB ) of following capacityMCCB / ACB & suitable forsandwich typeAluminiumbus trunkingas required. 38 160 Amp.to 250 Amp. MCCB 39 300 Amp.to 400 Amp. MCCB 40 S&F following sizesof ISI marked ( IS:14927 P - II ) PVC casing capping along with accessorieslike coupler, inner, outer, elbow, square box, tee etc. on surfacewith screws, expansionfastenersas required. 41 25 mm x 12 mm 42 32 mm x 12 mm 43 P & F following modular accessories made out of unbreakable and fire retardant poly carbonate with silver contacts including making connections testing etc. as required 44 Blanking plate 45 P& Fof IP-6S protected high power LEDflood light system with Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED fixture supplied with pre wired cable of 1 mtr. Integrated driver shall be high efficiency having efficiency more than 85 % and in compliance to IEC standards/BIS certified. The System level Luminaire efficacy >=100 with High Power LEDs of CREE/NICHIA/OSRAM/PHILIPS/SEOUL make is to be used. LEDDriver Input Voltage AC 110 to 270 V AC with Auto resetting Safety Cut-off. Input Frequency 50Hz±3% Power Factor >0.95 Driver Efficiency >85%, Control Gear Integral Design, THD(I) <10%. Electrical Connector Must be provided Surge Protection Min >=5KV internal and 10KV external in 80W onwards,Humidity 10% to 90% RHWorking Temp -20C to SOC. LEDLuminaire Specifications: Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintenance.Manufactures Word Mark/Name Engraved/Embossed on die cast housing to allow traceability/authenticity till life of fixture. Fixtures shall be CEcomplianced. 46 High Power LED Flood Light 150W 47 SITC of Managed Layer-2 Intelligent Ethernet Switch providing 24 x 10/100 Fast Ethernet ports and with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software