| 1 | 11 KV Feeder Work |
| 2 | Supply & Erection of 11 KV Section Double pole structure (Riser) made of following types of supports duly grouted in 1:4:8 cement concrete (1 cement, 4 coarse sand and 8 grit of 20mm nominal size) Plinthed, Plastered and painted in the same manner as already specified for respective supports with one nos. channels of size 100x50mm and 75x40mm M.S. channel and 2 Nos. bracing of angle iron size 65x65x6mm 3M length fixed with packing piece and bolt and nuts as required including cost of material, labour and T & P required for proper completion of work as per direction of E/I. Only manufacturers whose GTP will be Approved in MVVNL |
| 3 | Double Pole S.T. Pole 410 SP-55, 11.00 M. Long |
| 4 | Supply of following Size 11 KV Standered Compacted Aluminium Conductor Screen with Extruded Semi conducting compound, XLPE Insulated, insulation screening with Extruded Semi conducting compoundin combination with Copper Tape, Cores laid up, innersheath of PVC, Galvanised steel strip Armoured & overall PVC sheathed cable confirming to IS 7098 ( Part-2) 2011 with up to date ammendments forproper completion work. Make:- Polycab/Gloster/Finolex/Universal /KEI/ Havells/as per direction of E/I. |
| 5 | 185 Sqmm 3 core |
| 6 | Supply and jointing of 11 KV Indoor/Outdoor jointing kit (Heat Sink) per XLPE cable including cost of all material Labour and T & P forproper completion of work as per direction of E/I. DSR 2022 S.No.10.4.2 & 10.5.2 Make:- Raychem/3M/Densons/as per direction of E/I. |
| 7 | 120-185 Sqmm3core Indoor Type |
| 8 | 120-185 Sqmm3core Outdoor Type |
| 9 | Supply & Fixing of G.I. Pipe of following size for cable duly clamped with supports by 2 No. with clamps of 50 x 6 mm M.S. flats bolts, Nuts and washer required for proper completion of work. Make:-TATA/SAIL/JINDAL/as per direction of E/I. |
| 10 | 100 mm dia (10.20 Kg/M) |
| 11 | Supply of HDPE pipe upto PN-6 working pressure Rating material Grade PE-80 Nominal dia (OD) 140 mm 8.30 mm thicknesscomplete in all respect as per relevants I.S. Technicals specification. |
| 12 | Drilling of Road Parallely & Road Crossing at a depth of 2 to 3 Mtr. as required & laying charges of cable & 140 mm Dia HDPE Pipe complete with all material, labour, Drilling machine & required T&P etc. required for proper completion of work as per Direction of E/I. |
| 13 | Supply & Making of suitable earth of O/H line pole with 2.5 Mtr. Long 20 mm dia M.S. rod complete with 7/16 SWG G.S. wire in 2.00 Mtr. Long 15 mm dia G.I. Pipe (0.96 Kg/Mtr.) duly clamped on pole with 3 No.s 20 x 3 mm M.S. Flat clamp with bolts nuts and washers complete with all material, labour and T&P etc. required for proper completion of work. |
| 14 | Supply & Fixing of danger board of size 200 x 250 x 1.6 mm of M.S. sheet fixed with clamp of 20 x 3 mm M.S. flat including bolts, nuts and washerduly painted completed with all material, labour and T&P etc. for proper completion of work. |
| 15 | Supply & Fixing of barbed wire (1.5kg) duly clamped with 2 No. clamps made of20x3mm at both ends on poles flat including bolts, required for nuts and T&P etc. required for proper completion of work. |
| 16 | Supply & Fixing of cable route marker made of 1:2:4 R.C.C. Block size 1000x400x100 mm grouted with 1:3:6 cement stone grit coarse sand 30cm below G.L. with painting numbering & marking etc. complete with all required material T&P etc. complete in all respects as per direction of E/I. |
| 17 | Supply, Installation, Testing and Commissioning of 33 KV 1250 A STC 31.5 KA / 3 Secoutdoor type Vacuum Circuit Breaker including loading, unloading, carriage & erection of the same on plinth with required channels, nut & boltsmaking all necessary connectionetc. as per direction of E/I. Make:- ABB/Schneider/Siemens/as per direction of E/I. |
| 18 | Supply and Burring of Safe Earthing Electrode T-39 (Hot Dip Galvainised)Length up to 3000 mm, outer pipe 76 mminner dia 38mmterminal Dia 12 mm, outer GI Pipe of SWG and inner GI Pipe of 12 SWG with Hot Dip Galvanisation up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square CI frame with hinged cover & masonary housing ( from electrode terminal to switch board, cost of 25x3 G.I. Strip will be extra)as per PWD SOR-2018 S.No. 725 (D) |
| 19 | Supply & Laying of 32mm x 6mm G.I. Strip from Earth Electrode directly in the ground as required complete in all respect as per PWD SOR 2018 S.No. 717 |
| 20 | H.T. Work |
| 21 | Supply and Erection of following steel tubular polesBottom Portion Galvanised with base plate with 1/6 over all length of pole grouted with cement concrete below G.L. in 1:4:8 (1 cement 4 fine sand and 8-40mm nominal size OBB) including plinthing of pole 30cm above the groundlevel and 10cm below G.L. with 1:4:8 cement coarse sand & 20mm nominal size stone grit plastering with 1:4 cement sand mortar (1 part cement 4 part fine sand of FM-1.25) painting and numbering and also making strip with enamel paint in white and P.O red colour alternate layers of 20cm upto 1M above the plinth on pole including excavation, back filling etc. rate includes cost of all materials, labour and T & P etc. required for proper completion of work as per direction of E/I. Make:- Only manufacturers whose GTP will be Approved in MVVNL |
| 22 | 410 SP 5511.0 M long |
| 23 | Supply & Fixing of F-bracket for 11KV pin insulator |
| 24 | S.T. pole |
| 25 | Supply & Fixing of V-shape cross arm made of M.S. channel size 75x40mm(5.7kg/m) as per Direction of E/I. |
| 26 | Supply & Fixing of Straight M.S. channel size 100x50mm (7.9 kg/m) 1.380M. Long for Cross Arm |
| 27 | Supply & Fixing of straight of M.S. channel size 75x40 mm (5.7kg/m) 2.24 Mtr. Longfor guarding. |
| 28 | Supply & Fixing of clamps make of 75x10mm M.S. flat with packing piece for securing channel of item no. 3, 4 & 5 with the following types of supports. These will be painted with Al. paint in two coats over one coat of red oxide of complete with bolt & nut etc. |
| 29 | For S.T. pole |
| 30 | Supply & Erection of \"D\" clamps (For Disc Insulator)Made of 50 mm x 6mm flat iron on steel tubular poles / steel rail poles with bolts, nuts etc. complete in all respects including painting with Aluminium paint . as per PWD SOR-2018 S.I. No. 623 |
| 31 | Supply & Fixing of 11 KV pin insulator with pin on steel poles or any where specified including bolt and nut to fasten the pole cap/cross arm with the pole. |
| 32 | Supply & Fixing of 11 KV disc. and fittings B/S type on cross arm/clamps fixed on poles including bolts, nuts and washers etc. for proper completion of work. |
| 33 | Supply & Erection of 11 KV section Double pole structure (Riser) made of following types of supports duly grouted in 1:4:8 cement concrete (1 cement, 4 coarse sand and 8 grit of 20mm nominal size) Plinthed, Plastered and painted in the same manner as already specified for respective supports with one nos. channels of size 100x50mm and 75x40mm M.S. channel and 2 Nos. bracing of angle iron size 65x65x6mm 3M length fixed with packing piece and bolt and nuts as required including cost of material, labour and T & P required for proper completion of work as per direction of E/I. Make:- Only manufacturers whose GTP will be Approved in MVVNL |
| 34 | 11 Mtr. long410 SP-55 |
| 35 | Supply & Fixing Eye bolt 100x12mm with nut on guarding channel fixed on steel supports. |
| 36 | Supply and Erection of suitable size of ACSR conductor weasel, rabbit, raccon & dog confirming to latest relevant IS specification on steel support including binding, jumpering, sagging and cost of all material, labour and T & P required for proper completion of work as per direction of E/I.As Per PWD SOR-2018 S.I. No. 627 |
| 37 | Raccon/Dog |
| 38 | Supply and Erection of 7/16 SWGG.S. wire used with guarding channel on steel poles including the cost of material, labour and T & P etc. required for proper completion of work. |
| 39 | Supply & Fixing of Cradle type guards of 6 SWGG.I. wire including binding etc. complete as Per PWD SOR-2018 S.I. No. 629 |
| 40 | Making Suitable earth of H.T. overhead line pole with 2.5 Mts. long 20mm M.S rod connected with 7/16 SWGG.S. wire duly clamped & binded on pole including the cost of materials, labour and T & P required for proper completion of work as per direction of E/I. |
| 41 | Supply & erection of stay set at 3.5 Meters away from the pole complete with galvanized 19 mm dia x 1.80 Metres long stay rod, 30 cm x 30 x 6.3 mm anchor plate, thimble stay clamps, stay insulator, 19mm600 mm double screwtightener, 7/3.5 mm G.I. Stay wire etc. in 1:3:6 cement concrete complete in all respect. As per PWD SOR-2018 S.I. No. 631 |
| 42 | Supply and Erection of strut stay atleast 1.8Mts. away or as per actual site requirement for following types or supports duly grouted plinthed with cement concrete in the ratio 1:4:8 (1 part cement, 4 part fine sand and 8 part 20mm size nominal size grit) plastered with cement find sand mortar in the ratio 1:4 (1 part cement & 4 part fine sand of FM-1.25) painted and numbered in the same manner as already specified for S/F of respective support for L.T. works. Including 2 Nos. M.S. clamps made of 50x6mm M.S. flat with nut bolt and washers required for proper completion of work as per direction of E/I. |
| 43 | 410 SP 55, 11 Mtr. long S.T. Pole |
| 44 | Supply & Fixing of danger board (L.T.) size 200x150mm at suitable height of pole as per direction of E/I |
| 45 | Same as above but size 200x250mm |
| 46 | Supply & Fixing of barbed wire (1.5kg) duly clamped with 20x3mm M.S. flats at both ends on steel poles at suitable height as per direction of E/I. |
| 47 | Supply & Laying of 3 Core Standered Aluminium Conductor XLPE (Cross Linked Polyethylene) insulated PVC Bedded, Galvanised Flat Steel Strip armoured Cables Confirming to IS 7098 (Part-II with latest Ammendments) 11 KV Grade at a depth of 900 mm below Ground Level over a cushion of 100 mm thick fine river sand all around and protected with well burnt bricks on sides and on top put across. The armouring of cable shall be properly connected with earth conductor by clamps. Make:- Polycab / Gloster/Finolex/Universal /KEI/ Havells/as per direction of E/I. |
| 48 | 120 Sqmm 3 Core as per PWD SOR 2018 S.No. 506 (f) |
| 49 | Supply and jointing of Outdoor Type 11 KV jointing kit (Heat Sink) per XLPE cable including cost of all material, Labour and T & for proper completion of work as per direction of E/I. DSR 2022 S.No. 10.5.2 Make:- Raychem/3M/Densons/as per direction of E/I. |
| 50 | 120 Sqmm3core |
| 51 | Supply & Fixing of following Size of G.I. pipe \"B\" class for cable clamped with supports by 3 Nos. clamps made of 20x3mm M.S. flat and suitable size of nut bolt and washer required for proper completion of work as per direction of E/I. Make:-TATA/SAIL/JINDAL/as per direction of E/I. |
| 52 | 80 mm dia |
| 53 | L.T. Work |
| 54 | Supply and Erection of 8.5 Mtr. long PCC pole confirming to the I.S.S. No. IS 2678-1960,IS 1343-1960 & IS 456-1964 grouted with 1:4:8 cement, concrete ( 1 cement, 4 fine sand and 8-OBB of 40mm nominal size including plinthing with 20mm nominal size stone grit 10cm below the G.L. & 30cm above the G.L. plastering with 1:4 cement mortar, painting and numbering of pole and making strip with enamel paint complete with all materials, labour and T & P etc. and also including the cartage of pole to site of work.Only manufacturers whose GTP will be Approved in MVVNL |
| 55 | 8.5 Mtr. long PCC pole |
| 56 | Supply & Fixing of suspension type clamp made of Al alloy and shall be capable of holding Al alloy messenger wire of compacted dia. The eye hook shall be made of forged or mild steel the clamp size 50x6mm M.S. Flat shall be provided with black weather resistant plastic coating of atleast 1mm thickness to prevent insulation of phase conductor from chafing due to rubbing against the clamp it shall provided sufficient flexibility to allow the movement of clamp at both, straight and angle location its hard ware shall have good finished and all ferous fittings, eye hook, bolts, nut and washer shall be galvanized with zinc and it also includes all the cost of material, labour T & P proper completion of work. |
| 57 | Supply & Fixing of dead end clamp made of high strength Al alloy and U-bar shall be made ofhot dip galvanised steel and eye hook of forged steel or mild steel clamp size 50x6mm shall be suitable for holding suitable messenger wire all ferous fitting eye hook bolt, nut and washer shall be galvanised with zinc including the cost of material, labour. T & P for proper completion of work. |
| 58 | Supply & Fixing of piercing connector made of Al alloy suitable of holding main conductor/ tap conductor of compacted diameter the connector shall be covered by the black weather resistant insulation cover made of polythylene atleast 2 mm thick to avoid short circuit and corrosion including the cost of material, labour. T & P for proper completion of work. |
| 59 | For phase wire |
| 60 | For street lightwire |
| 61 | For neutral conductor |
| 62 | Supply & Fixing of distribution board box for three phase 10 way 100 Amp. connection made of Standard Approved Make Size 450x300x200mmcomplete with 03 No. kit kat 63Amp phase bus bar 25x5mm, neutral bus bar 20x5mm, copper flat, clamps holes etc. including the cost of material, labour,T & P etc. required for proper completion of work. |
| 63 | Supply & Laying of following size of Arial bunch cable 1100 V grade confirming to latest relevant specification on steel/PCC supports including binding, jumpering sagging and cost of material, labour,T & P etc. required for proper completion of work. |
| 64 | (3Cx120 + 95+16) Sqmm |
| 65 | (1Cx35) Sqmm |
| 66 | (1CX16) Sqmm |
| 67 | Supply & erection of stay set at 3.5 Meters away from the pole complete with galvanized 19 mm dia x 1.80 Metres long stay rod, 30 cm x 30 x 6.3 mm anchor plate, thimble stay clamps, stay insulator, 19mm600 mm double screwtightener, 7/3.5 mm G.I. Stay wire etc. in 1:3:6 cement concrete complete in all respect. As per PWD SOR-2018 S.I. No. 631 |
| 68 | Supply and errection of strut set atleast 1.5 meters away or as per actual site requirement grouted in the same manner as specified for respective supports & plinthing of pole with 1:4:8 cement, concrete (1 cement 4 coarse sand and 20mm nominal size stone grit) 40Cm high with 30cm above G.L.& 10Cm below G.L., plinthing, plasteringand painting including clamps made of 50x6mm M.S. flat with bolts nuts and washers etc. complete in all respect as per direction of E/I with following supports. |
| 69 | With 8.5 Mts. long PCC Pole |
| 70 | Making suitable earthing of PCC poles with 2.5Mts. long 20mm dia M.S. rod with 7/16 SWGG.S. wire in 15mm dia 2Mtr. long G.I. pipe duly clamped with 3 nos clamps and binding on poles including cost of labour & T & P etc. required for proper completion of work. |
| 71 | Supply and laying of 32x6 mm G.I. strip from earth electrode directly in the ground as required complete in all respect .As per UP PWD SOR 2018 SI No. 717 |
| 72 | Supply and fixing of palm or pin copper tin plated cable socket (lugs) to the cable leads insulating with tape and making connections etc. complete in all respects as per direction of E/I. |
| 73 | 16 Sqmm. As Per PWD SOR-2018 S.I. No. 504 (d) |
| 74 | 35 Sqmm. As Per PWD SOR-2018 S.I. No. 504 (f) |
| 75 | Transformation Work |
| 76 | Supply and Erection of Double Pole Structure made of following types of support duly grouted in 1:4:8 cement concrete (1 cement, 4 coarse sand and 8 grit of 20mm nominal size plinthed plastered & painted in the same manner as already specified for respective supports suitable for Pole mounted type substation with different types of M.S. Channel and angle iron duly fabricated for disc fittings D.O. fuse set, TPMO ladder stand projecting outside dropper and bracings, including cost of all material, labour and T & P required for proper completion of work as per direction of E/I.Only manufacturers whose GTP will be Approved in MVVNL |
| 77 | With 11 Mtr. long 410 SP 55 S.T. Pole Bottom section Galvanised with base plate |
| 78 | Supply and Erection of Double Pole Structure made of following types of support duly grouted in 1:4:8 cement concrete (1 cement, 4 coarse sand and 8 grit of 20mm nominal size plinthed plastered & painted in the same manner as already specified for respective supports sutable for plinth mounted type substation with different types of M.S. Channel and angle iron duly fabricated for disc fittings D.O. fuse set, TPMO ladder stand projecting outside dropper and bracings , including cost of all material, labour and T & P required for proper completion of work as per direction of E/I. Only manufacturers whose GTP will be Approved in MVVNL |
| 79 | With 11 Mts. long 410 SP 55 S.T. Pole Bottom section Galvanised with base plate |
| 80 | Supply and errection of 11 KV TPMO set complete in all respect as per direction of E/I. |
| 81 | Supply and errection of 11 KVD.O. fuse set complete in all respect as per direction of E/I. |
| 82 | Supply and fixing of H.T./L.T. jumpering and connections on double pole/four pole, lightning arrestor and transformer. The rates include the cost of all materials, labour and T & P etc. required for proper completion work. |
| 83 | Supply, Installation, Testing & Commissioning with Loading & Unloading offollowing size11/0.433 KV \"Energy Efficient (Level-1)\" Aluminium Wound, Outdoor, Delta- Star, Distribution Transformer as per BIS 1180-2014 Standards and Latest Specification of MVVNL Make:-Make: TRANSTRON/MODERN /ELECON or Whose Latest GTPApproved in MVVNL having valid CPRI/ERDA Type Test Report |
| 84 | 63 KVA |
| 85 | Supply, Installation, Testing & Commissioning with Loading & Unloading offollowing size 11/0.433 KV \"Energy Efficient (Level-1)\" CopperWound, Outdoor, Delta- Star, Distribution Transformer as per BIS 1180-2014 Standardsand Latest Specification of MVVNL Make:-Make: TRANSTRON/MODERN /ELECON or Whose Latest GTPApproved in MVVNL having valid CPRI/ERDA Type Test Report |
| 86 | 250 KVA |
| 87 | 400 KVA |
| 88 | Supply, Installation, Testing and Commissioning of Outdoor Type,dust and vermin proof weather proof with rain canopy on four sideswith locking arrangement, 800A/630A ACB L.T Panel Fabricated out of 2.0mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineer in charge after proper sheet treatment process of sheet steel. All indicating lights shall be LED type and all wiring shall be done from PVC Insulated copper flexible wire. The panel shall be completed in all respect and shall consist of following material.Incomer: 800A/630 A F.P Manual Fixed type A.C.B with Metering (ie Ameter with ASS, Voltmeter with VSS) along with, Phase Indicating Lights, CT,Control MCB etc. -1 Set Panel will have suitable rating (1Amp/Sqmm) of Aluminium Bas bar for Proper Temination of Cables. ( minimum 400 sqmm6 nos )All bus bars shall be insulated with coloured heat shrinkable PVC sleeved. All bus bar supports shall be non hygroscopic DMC/SMC supports. Make:- ABB/Schneider/Siemens/as per direction of E/I. |
| 89 | 800A/630A |
| 90 | Supply & Fixing of lightening arrestor set (3 Nos.) suitable for mounting on steel supports complete with all materials, labour and T & P required of proper completion of work as per direction of E/I. |
| 91 | Supply & Erection of TPN Distribution Pillar Fabricated with Wire Clad Dust and Vermin Proof as per Drawing consisting suitable size of Copper Bus Bar 60 x10mm or Equivalent sectional area consisting Henley\"s Pattern fuse unit set complete as follows, Metallic Pillar shall be made of 14 SWG MS Sheet on frame of angle Iron size 35x35x5mm Duly painted with 2 Coat of approved paint over rust resisting primer both side locking arrangement and handle & Danger Board complete with suitable masonary plate-form for mounting the pillar. The Pillar shall have earthing terminals as per Direction of E/I. Only PWD & CPRI Approved Make |
| 92 | Incoming : Two (2) Nos. 500 Amp.Fuse unit |
| 93 | Outgoing : Two (2) Nos. 500 Amp.Fuse unit |
| 94 | Outgoing : Two (2) Nos. 300 Amp.Fuse unit |
| 95 | Supply & Erection of TPN Distribution Pillar Fabricated with Wire Clad Dust and Vermin Proof as per Drawing consisting suitable size of Copper Bus Bar 60 x10mm or Equivalent sectional area consisting Henley\"s Pattern fuse unit set complete as follows, Metallic Pillar shall be made of 14 SWG MS Sheet on frame of angle Iron size 35x35x5mm Duly painted with 2 Coat of approved paint over rust resisting primer both side locking arrangement and handle & Danger Board complete with suitable masonary plate-form for mounting the pillar. The Pillar shall have earthing terminals as per Direction of E/I.Only PWD & CPRI Approved Make |
| 96 | Incoming : Two (2) Nos. 300 Amp.Fuse unit |
| 97 | Outgoing : Three (3) Nos. 300 Amp.Fuse unit |
| 98 | Construction of fencing plinth of following sizes in Ist class brick work including plaster and providing flat bricks soling and pointing the same with 1:2 cement and fine sand mortar over 75mm thick cement concreting in the ratio 1:6:12 in open space of the cage as per direction of E/I |
| 99 | 6x4x0.23m for Substation |
| 100 | Supply of fixing of 2.45M. High cage fabricated with 3.0mm thick expanded metal/wire mesh of equivalent weight fixed on 50x50x6mm angle iron frame having vertical members spaced at 1.0M to 1.25M. and horizontal members spaced at 1.20M the vetical members shall be grouted in ground and horizontal members in the wall to a depth of 300mm with ends folded. The cage shall have 1000x2000mm size single leaf door with locking arrangement having door frame fabricated with 35x35x5mm angle iron and 3mm expanded metal wire mesh of equivalent weight duly fixed with the cage member. The cage shall have nut bolt arrangement for opening the sides by providing tees 45x20cm of angle iron size 50x50x6mm as per direction of E/I. It shall be painted with red oxide primer and synthetic enamelled paint as per direction of E/I. including all materials, labour and T & P for proper completion of work.PWD SOR 2018 SI No. 1142 |
| 101 | Supply and Burring of Safe Earthing Electrode T-39 Zn-Zinc Coated, Length 3000 mm, outer pipe 76.30 mm x 3.2 mm inner pipe 42.40 mm x 2.6, terminal Dia 12 mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square CI frame with hinged cover & masonary housing (From electrode terminal to switch board, cost of 25 x 3 GI Strip will be extra) UPPWD SOR-2018 item no. 726 (D) |
| 102 | Construction of plinth for Transformer size 2.0x1.25x1.0 Complete With all materials, labour and T & P required for proper completion of work as per specification drawing and direction of E/I |
| 103 | Supply & Laying of following size of Al. conductor PVC insulated armoured served sheathed cables 1100V grade at a depth of 750mm below GL over a cushion of 75mm thick sand all around & protected with burnt bricks on sides andon top. On surface the cable run shall be fixed on M.S clamps etc. of suitable size or as directed by the Engineer- Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.as per PWD SOR 2018 SI No. 501 (o), (r) & (t) Make:- Polycab / Gloster/Finolex/Universal /KEI/ Havells/as per direction of E/I. |
| 104 | 120 Sqmm3½core |
| 105 | 240 Sqmm3½core |
| 106 | 400 Sqmm 3½ core |
| 107 | Supply and fixing of palm or pin copper tin plated cable socket (lugs) to the cable leads insulating with tape and making connections etc. complete in all respects as per PWD SOR 2018 SI No. 504 (j), (m) & (o) |
| 108 | 120 Sqmm |
| 109 | 240Sqmm |
| 110 | 400Sqmm |
| 111 | Street Lighting Work |
| 112 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 45to 50 Watt. Confirming to IP 66 and above Protection complete in all respect as per PWD SOR 2018S.NO. 1421CAT-AAA Make:- Havells/Polycab/Philips /Jaquar/as per direction of E/I. |
| 113 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 75to 90 Watt. Confirming to IP 66and aboveProtection complete in all respect as per PWD SOR 2018 SI NO. 1423 CAT-AAA Make:- Havells/Polycab /Philips/Jaquar/as per direction of E/I. |
| 114 | Supplying and fixing of 32 mm dia x2.00 meters long G.I. pipe(medium class) bracket for mounting of fluorescent/HPMV/HPSV street light fitting on pole including bending the pipe to the required shape.2 nos 40mmx3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. DSR 2022 S.No. 12.34 |
| 115 | Supply & Fixing of 12.5 Mtr. High Mast Shaft of approved make with rising system hot dip Galvanised inside & out side dip, having pole sheet thickness 3mm. Top dia minimum 150mm, Bottom dia 310mm base plate 25mm thick suitable for wind velocity as per IS 875 Part3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 luminaries & its control gear boxes 0.75 HP Power tool motor, 3 pointsuspension system with steel wire rope 6mm dia, double drum winch, including making suitable foundation as per manufacture drawing/site requirement along with foundation bolts nuts,washers, anchor plates etc. complete in all respect as per PWD SOR 2018 S.No. 651 Make:- BAJAJ/VALLMONT/RRISPAT CONSOUL/as per direction of E/I. |
| 116 | Supply and fixing ofFactory Wired Integral LED Flood Light Luminaries with Die cast Aluminium housing and lenses built with mandatory Driver set suitable for 170 to 200 Watt. confirming to IP65/66 Protection complete in all respect including labour. Cat AAA (18700-22000 System lumens, high power LED with lenses, 110lm/w, PF>0.95, THD<10% at full load, CRI> 70%, potted driver set ( non circuitary) phase to phase protection at 440 Volt & > 300 Volt auto cut and restart feature with 5 years warrantee as per PWD SOR 2018 SI No-1455 CAT-AAA Make:- Havells/Polycab /Philips/Jaquar/as per direction of E/I. |
| 117 | Supply & Laying of following size of Al. conductor PVC insulated armoured served sheathed cables 1100V grade at a depth of 750mm below GL over a cushion of 75mm thick sand all around & protected with burnt bricks on sides andon top. On surface the cable run shall be fixed on M.S clamps etc. of suitable size or as directed by the Engineer- Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.as per PWD SOR 2018 SI No. 501(b) & (i) Make:- Polycab / Gloster/Finolex/Universal /KEI/ Havells/as per direction of E/I. |
| 118 | 10 Sqmm 2 Core |
| 119 | 16 Sqmm 4 Core |
| 120 | S&F of100 Amp. 415 V metal clad T.P.N. HRC Type Switchfuse unit complete with HRC Fuse on angle Iron Bracket complete in all respect.PWD SOR 2018 SI NO. 328 CAT-B |