| 1 | Supply and Laying cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables(heavy duty) 1100V grade with stranded aluminium conductor of size 6 Sqmm 2 core complete all as specified & directed by Engr in Charge. |
| 2 | All as per Ser item No. 1 above but of size 10 Sqmm 2 core |
| 3 | All as per Ser item No. 1 above but of size 16 Sqmm 4 core |
| 4 | All as per Ser item No. 1 above but of size 25 Sqmm 3.5 core |
| 5 | All as per Ser item No. 1 above but of size 35 Sqmm 3.5 core |
| 6 | All as per Ser item No. 1 above but of size 50 Sqmm 3.5 core |
| 7 | All as per Ser item No. 1 above but of size 70 Sqmm 3.5 core |
| 8 | All as per Ser item No. 1 above but of size 95 Sqmm 3.5 core |
| 9 | All as per Ser item No. 1 above but of size 120 Sqmm 3.5 core |
| 10 | All as per Ser item No. 1 above but of size 150 Sqmm 3.5 core |
| 11 | All as per Ser item No. 1 above but of size 240 Sqmm 3.5 core |
| 12 | Dismantling cross arms of MS channel or angle sections etc. complete all as specified & directed by Engr in Charge. |
| 13 | Dismantling insulators any type and size complete all as specified & directed by Engr in Charge. |
| 14 | Dismantling of stay assembly complete, (Demolition of concrete, etc and excavation measured separately) complete all as specified & directed by Engr in Charge. |
| 15 | Dismantling of ACSR conductors of any type complete all as specified & directed by Engr in Charge. |
| 16 | S&F MS junction box IP-66 \"halogen free and weather proof for out door opertion on street light pole of 200mm x 160mm x 100mm size and bakelite terminal plate suitable for 4 pole for loop in loop out of XLPE armoured cable up to 35 Sqmm x 4 core, MCB SP 6 Amps C Series (01Nos), cable lugs, and 4 No of suitable size aluminium bus Bar and MS fixing bracket made out of 25mm x 4mm MS flat for fixing the box to pole complete with bolts and nuts, and washers complete all as specified & directed by Engr in Charge. |
| 17 | S&F MS junction box IP-66 \"halogen free and weather proof for out door opertion on street light pole of 200mm x 160mm x 100mm size and bakelite terminal plate suitable for single pole and neutral for loop in loop out of XLPE armoured cable up to 10 Sqmm x 2 core, MCB SP 6 Amps C Series (01Nos), cable lugs, and 2 No of suitable size aluminium bus Bar and MS fixing bracket made out of 25mm x 4mm MS flat for fixing the box to pole complete with bolts and nuts, and washers complete all as specified & directed by Engr in Charge. |
| 18 | S&F for fixing of GI pipe (light grade) bracket of 40mm bore size of 1.2 mtr long bent to shape for fixing of LED street light fittings and fixing to pole, walls etc including fixing of clamp, nut, bolt etc complete all as specified & directed by Engr in Charge. |
| 19 | S&F Cable PVC insulated and FR PVC round sheathed copper conductor 2 core AC 1100 Volts grade 1 sqmm size and required flexible conduit etc complete all as specified & directed by Engr in Charge. |
| 20 | M&L for Earthing complete with galvanised earth plate electrode of size 600x600x6 mm thick burried directly in ground earth pit not less than 2.25 m below ground level connected to4 mm dia GI earth wire as earth lead by means of bolts,nuts,washers of Gl all as shown in electrical plate No 3 of SSR part I connected to earth test point including earth work excavation in any type of soil PCC (1:3:6) type C1 bed and chamber RCC (1:2:4) type B1 cover 40mm thick including 6 mm dia reinforcement and funnel watering pipe etc complete all as specified & directed by Engr in Charge. (Earthing for street light pole) |
| 21 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 m in depth in a hard/dense soil for laying underground cables/ errection of steel tubular poles / stay pit etc complete all as specified & directed by Engr in Charge. |
| 22 | M&L for laying dry bricks old size with subclass \"B\" made of burnt clay best quality locally available with permissible tolerance, laid straight trench for protection of cable complete all as specified & directed by Engr in Charge. |
| 23 | Returning and filling in two parts (i) using riddled soil obtained from excavated soil upto depth of 30 cm (8 cm below cable and remaining above cable for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil complete all as specified & directed by Engr in Charge.Note- Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS - 1255-1983 and refilling in trenches as in cable cushioning. |
| 24 | Removing excavated surplus material to a distance n.exc 50 m and depostimg where directed at alevel n exc. 1.5 m above the starting point in any type of soil complete all as specified and directed by Engr-in-Charge. |
| 25 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified & directed by Engr in Charge. |
| 26 | M&L for Tubes, \"light grade\" 50mm bore, galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors |
| 27 | M&L for Tubes, \"light grade\" 80mm bore, galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors |
| 28 | Supply, install, testing and commissioningoutdoor Feeder piller panel board kiosk type factory made dust/vermin proof made out of CRCA sheet 3.15 mm thick CPRI approved duly powder coated having opening and locking arrangementboth in front and rear side(independent door for each item on front side) mounted on 4 Nos angle iron 50x50x6 mm, 45 cm long embedded in PCC 1:3:6 type C2 complete with aluminium bus bar ofrating 1.5 times the rated capacity of incomer, IP 65 protection, suitable cable gland for incomming and outgoing cables with lugs and connections etc required nuts ,bolts and washer incl complete control wiring with suitable size PVC copper conductor cable and provn of cable lugs etc. Including provision of following accessories/eqpt incl cable gland etcINCOMING(a) MCCB 500 A, 415 V , 4 pole with over load short circuit protection, breaking capacity 35 KA-01(b) Multi function meter for measuring V,A,F,kW,KVAincludingCTs of suitable capacity -01(c) LED Phase Indication lamp (RYB) -01 Set |
| 29 | OUTGOING(a) MCCB 320 A, 415 V , 4pole with over load short circuit protection, breaking capacity 35 KA-01(b) MCCB 125 A, 415 V , 4pole with over load short circuit protection, breaking capacity 35 KA-01(c) MCCB 100 A, 415 V , 4pole with over load short circuit protection, breaking capacity 35 KA-01(d) MCCB 63 A, 415 V, 4 pole with over load short circuit protection, breaking capacity 25 KA-01(e) Wiring of above accessory with suitable size of copper conductor cableNote :-(i) All MCCBs / instruments / MCBs / Bus Bar shall be housed in a separate housing with on- off latches in the housing. (ii) Space for provn of one extra MCCB should be provided in the panel. (iii) Front and back openable. |
| 30 | Supply, install, testing and commissioningoutdoor Feeder piller panel board kiosk type factory made dust/vermin proof made out of CRCA sheet 3.15 mm thick CPRI approved duly powder coated having opening and locking arrangementboth in front and rear side(independent door for each item on front side) mounted on 4 Nos angle iron 50x50x6 mm, 45 cm long embedded in PCC 1:3:6 type C2 complete with aluminium bus bar ofrating 1.5 times the rated capacity of incomer, IP 65 protection, suitable cable gland for incomming and outgoing cables with lugs and connections etc required nuts ,bolts and washer incl complete control wiring with suitable size PVC copper conductor cable and provn of cable lugs etc. Including provision of following accessories/eqpt incl cable gland etcINCOMING(a) MCCB 320 A, 415 V , 4 pole with over load short circuit protection, breaking capacity 35 KA-01(b) Multi function meter for measuring V,A,F,kW,KVAincludingCTs of suitable capacity -01(c) LED Phase Indication lamp (RYB) -01 Set |
| 31 | OUTGOING(a) MCCB 250 A, 415 V , 4pole with over load short circuit protection, breaking capacity 35 KA-01(b) MCCB 63 A, 415 V, 4 pole with over load short circuit protection, breaking capacity 25 KA-02(c) Wiring of above accessory with suitable size of copper conductor cableNote :-(i) All MCCBs / instruments / MCBs / Bus Bar shall be housed in a separate housing with on- off latches in the housing. (ii) Space for provn of one extra MCCB should be provided in the panel. (iii) Front and back openable. |
| 32 | Cutting of road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including making good the distrubed surface complete all as specified & directed by Engr in Charge. |
| 33 | Painting to existingof steel poles 11/9 Mtr long long with one coat of synthetic enamel paint in alternate strips of blackand yelow colours 30 cm height each total 05 Nos commencing form the top of PCC coping incuding painting of coss arms, nut bolts, clamps etc as fixed on pole with tow coats of aluminium paint and marking pole No with paint as per approved pattern, complete all as specified & directed by Engr in Charge. (Numbring shall be hand written only, size of letter 100X10mm (Heightxwidth)) |
| 34 | S&F cable route indicator shown \"LT UG cable\" with aero made of CI in suitable eleiptical shape and fixed in MS flat 50X6mm, 70cm long ( all word embosed) and embaded in PCC block of size 30 x 30 x 60cm in ground duly painted in silver colour complete all as specified & directed by Engr in Charge. |
| 35 | Schedule of Credit |