| 1 | Lump sum amount worked out by the contractor for \"Buildings & Structures\" as listed in Schedule \"A\" Part-I on Serial Page No. 37 |
| 2 | Lump sum amount worked out by the contractor for \"Internal Water Supply\" as listed in Schedule \"A\" Part-II on Serial Page No. 38 |
| 3 | Lump sum amount worked out by the contractor for \"Internal Electrification\" as listedin Schedule \"A\" Part-III on Serial Page No.39 |
| 4 | Lump sum amount worked out by the contractor for \"External water Supply \" as listedin Schedule \"A\" Part-IV on Serial Page No.40 |
| 5 | Lump sum amount worked out by the contractor for \"External fire fighting system\" as listedin Schedule \"A\" Part-V on Serial Page No.41 |
| 6 | Schedule \"A\" Part - VI : [Miscellaneous Items] [ Internal Water Supply, Internal Electrification,External water Supply,External fire fighting system,HOT Crane]:[To be quoted by the bidder.] |
| 7 | M&L for Point wiring with 1.5 Sq.mm FRLSH PVC insulated unsheathed copper conductor cable, single core multi stranded 1100Volt grade confirming to IS 694: 1990, drawn in and including rigid PVC conduit not less than 20/25mm bore, concealed type, medium grade as per IS 9537 (Part 1-1983) with conduit accessories, junction boxes, tees, terminal boxes with and including concealed pressed steel terminal box of suitable size fabricated out of 2mm thick MS sheet and 3mm thick lminated hylam sheet top cover for fixing switches, switch socket, including one run of 1.5 Sq.mm single core FRLSH PVC unsheathed copper conductor cable as earth continuity conductor and connected to common earth dolly, for one light point controlled by one way switch, complete all as specified and as directed. |
| 8 | Description all as per Serial Item No.6.01 here in before but for fan point controlled by one way switches complete. |
| 9 | Description all as per Serial Item No.6.01 here-in-before but with 2.5 Sqmm copper conductor cable and2.5 Sqmm cable as earth continuity conductor for security light point controlled by one switch, complete all as specified. |
| 10 | S&F Wall mounting fan 450mm sweep 5star rated and energy efficientof approved colour and model, with complete accessories including provision of suitable clamp, flexible cable suitable for 230 Volt, AC 50 Hz, complete all as specified and as directed. |
| 11 | S & F heavy duty exhaust fan 300mm sweep900 RPM operatesin 230 volts single phase with louvers complete withall accessories and necessary PCC work including connection testing etc complete all as specified and as directed |
| 12 | S&F LED Building Security light fitting 40Watts, 230 volts, >100lum/W, with Suitable size GI bracket made out of 25/40mm GI pipe fixed with clamps, nuts&bolts etc., complete with IP 66 protection with LED lamp, driver, bracket with impact and corrosion resistant and all accessories, complete all as specified and as directed. |
| 13 | S&F MCBDP 32- 40 Amps with necessary connecting up in MCB DB complete all as specified and directed . |
| 14 | S&F Energy saving, environmentally friendly & robust 220 V ,AC decorative box type High bay light LED 80 Watt energy efficient,P.F>0.95, >100 lum/watt, with and including LED light driver holder connecting of with three core flexible copper conductor cable of suitable size, complete all as directed by Engr-in-charge. |
| 15 | M&L for Earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead 4mm GI wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of SSR Part-I, including excavation / earth work in any strata, adequate quantity of charcoal and common salt, PCC chamber with with RCC 1:2:4 type B1 40mm thick cover slab with suitable handle and angle iron frame of suitable size to fix the cover, with 20mm bore GI pipe light grade for watering with funnel, wire mesh and 15mm bore GI pipe medium grade for GI wire protection and 4mm GI earth wire, including testing after completion, complete all as specified and directed. Note : Earth wire will be measured after 7.5mtr from the earth strip or earth testing terminal block whichever is lesser under relevant item. |
| 16 | S&F 15mm dia 2 in 1 bib cock (fancy cock) twin elbow valve faucet (wall mount installation type) complete all as specified and as directed by Engr-in-charge. |
| 17 | S&F Health faucet & jet spray with SS flexible tube & Hook Health faucet (wall mounted installation type) complete all as specified and as directed by Engr-in-charge. |
| 18 | Design, Supply, installation and testing of horizontal split case centrifugal type pumping set for clear water suction, 415Volt, 3 phase, 50 Hz, 70meter head, 2900 LPM discharge capacity, with and including soft starter , single phase preventer, suitable control switch gear ACB/MCCB with wiring, MFM meter and PLC panel and suitable cable upto 25m, MS frame and necessaryfoundation, with\"Y\" strainer with cored hole/slots including suction discharge, and header pipes,electrically driven, confirming to IS 1520 & IS 6595 (Part-2), directly coupled with suitable AC induction motor through a flexible coupling, mounted on a common sturdy and robust C.I/M.S base plate, speed matching with nominal speed of Prime Mover at Duty condition, shut off head Min 110% & max 130% of the specified head , CI casing, Bronze Impellor, SS Shaft sealingwith mechanical seal, CI Stuffing Box, water sealed or mechanically sealed, Bronze Wear Rings, CI Gland, vibration proof coupling, heavy duty CI/MS base plate for pump & motor with ‘I’ section girders, channels, plates, bolts & nuts etc. vibration insulator, with induction type electric Motor , IE-3 NFLP, AC, 50 Hz 415Volts, 3-Phase, 1450 RPM, confirming to IS 4691 & IS 325 (amended up-to-date), IP 23 protection, “F” Class insulation, temperature rise limited to class B, ambient temperature up to 45degree C with 10% more than maximum power required by the pump and capable of providing rated output up to +10% voltage variation and + 3% frequency variation or lubricated roller driving and bearing or combination of both, grease lubricated roller bearing for non driving end bearing, complete for best efficient functioning with 3 years performance guarantee after complete installation, all as specified and as directed. Note:Contractor has to submit drawings for approval before manufacturing at factory and pump/ motors shall be confirming to GRIHA 3 rating. Quoted rate shall be inclusive of cost of cable required from starter to pump set motor. |
| 19 | Design, Supply, installation and testing of horizontal split case centrifugal type pumping set for clear water suction, 415Volt, 3 phase, 50 Hz, 60 meter head, 2400 LPM discharge capacity, with and including soft starter , single phase preventer, suitable control switch gear ACB/MCCB with wiring, MFM meter and PLC Panel and suitable cable upto 25m, MS frame and necessary foundation, with cored hole/slots including suction discharge, and header pipes,electrically driven, confirming to IS 1520 & IS 6595 (Part-2), directly coupled with suitable AC induction motor through a flexible coupling, mounted on a common sturdy and robust C.I/M.S base plate, speed matching with nominal speed of Prime Mover at Duty condition, shut off head Min 110% & max 130% of the specified head , CI casing, Bronze Impellor, SS Shaft sealing with mechanical seal, CI Stuffing Box, water sealed or mechanically sealed, Bronze Wear Rings, CI Gland, vibration proof coupling, heavy duty CI/MS base plate for pump & motor with ‘I’ section girders, channels, plates, bolts & nuts etc. vibration insulator, with induction type electric Motor , IE-3 NFLP, AC, 50 Hz 415Volts, 3-Phase, 1450 RPM, confirming to IS 4691 & IS 325 (amended up-to-date), IP 23 protection, “F” Class insulation, temperature rise limited to class B, ambient temperature up to 45degree C with 10% more than maximum power required by the pump and capable of providing rated output up to +10% voltage variation and + 3% frequency variation or lubricated roller driving and bearingor combination of both, grease lubricated roller bearing for non driving end bearing, complete for best efficient functioning with 3 years performance guarantee after complete installation, all as specified and as directed. Note: Contractor has to submit drawings for approval before manufacturing at factory and pump/ motors shall be confirming to GRIHA 3 rating. Quoted rate shall be inclusive of cost of cable required from starter to pump set motor. |
| 20 | S&F Cast Iron Foot valves ball type suitable for 150mm bore, shall confirm to IS:4038-1986,fitted with and including \"Y\" strainer which will have cored holes/solts with strainingand including necessary fixing arrangements complete all as specified as directed. |
| 21 | Design supply installationtesting and commissioning offire pump Electrically Driven horizontal split casecentrifugal type confirming to IS: 12469:1988 with CI casing bronze impeller and stainless steel shaft mounted on heavy duty bearing suitable for continuous operation with range of operation 0% to 150% of ratedcapacity of 440V,3 phase 50 Hz 70m Head 1450 RPM, 2280 LPM discharge including necessary foundation , suction and discharge pipe and all necessary items for electric and water supply connection upto main header with suitable foot valve with Y strainer with cored holes / slots including LT panel for controlling three motors accommodating with suitable soft starter and MCCB/ACB as per OEM recommendations and the pump shall be supplied with auto release valve/ pressure gauge at delivery and compound gauge at suction side (as per NFPA-20), and following parameters shall be provided for protection for motors : (a) Motor protection delay, (b) Over load / under load protection relay, (c) Motor protection relay, (d) Complete auto/ manual operation and test mode to test the pumps. All accessories complete all as specified. Note :- Contractor has to submit drawings for approval before manufacturing at factory and pump/ motorsshall be confirming to GRIHA 3star rating. |
| 22 | Design supply installationtesting and commissioning of fire pump Diesel Driven horizontal split casecentrifugal type confirming to IS: 12469:1988 with CI casing bronze impeller and stainless steel shaft mounted on heavy duty bearing suitable for continuous operation with range of operation 0% to 150% of ratedcapacity of 440V,3 Phase, 50 Hz, 70m Head 1450 RPM, 2280 LPM discharge including necessaryfoundation and all necessary items for electric and water supply connection upto main header with suitable foot valve with Y strainer with cored holes / slots and pump shall be supplied with auto release valve/ pressure gauge at delivery and compound gauge at suction including LT panel accommodating with suitablesoft starterand MCCB/ACB as per OEM recommendations. The pump shallbe supplied with its control panel 500 ltrs diesel engine tank having magnetic oil level indicator magnetic gauge, mounting stand and 2 nos of Dry batteries. The pump and engine & controller & battery cables, all other accessories and fittings as per the technical specifications complete in all respectcomplete all as specified. Following parametres shall be displayed in control panel for each engine driven pump set: -(a) Low fuel, (b) Low battery, (c) High temperature, (d) Low lub oil, (e) Engine start / fail,(f) Engine run.Note :- Contractor has to submit drawings for approval before manufacturing at factory and pump motorsshall be confirming to GRIHA 3star rating. |
| 23 | Design supply installation testing and commissioning ofback pull out type electrical motor driven Jockey pump horizontal split case centrifugal type confirming to IS 12469:1988 with CI casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for automating operation with run over loading power characteristics for frequent start one stop operation for 440 V, 3 phase, 50 Hz 70m Head, 1450 RPM, 180 LPM dischargewith suitable foot valve with Y strainer with cored holes / slots including including necessary foundation , suction and discharge pipe and LT panel accommodating with suitable soft starter and MCCB/ACB as per OEM recommendations and following parameters shall be provided for protection for motors : (a) Motor protection delay, (b) Over load / under load protection relay, (c) Motor protection relay, (d) Complete auto/ manual operation and test mode to test the pumps.(e) the electric motor capacity shall be of 11KW complete all as specified.Note :- Contractor has to submit drawings for approval before manufacturing at factory and pump motorsshall be confirming to GRIHA 3star rating. |
| 24 | M&L for supplying erection testing and commissioning of Double Girder HOT Crane with span 6 mtr approx.Having 3 ton capacity and lifting hook height 3 mtrs from floor level, long travel of length 8 mtr with phosphorusbronze cladding wheels grade 80 load chain & zinc plated hand chain, non-ferrous parts like chain wheels, chain guides, ratchet wheel and stripping fork, double girder rails, controlling panel chain pully block confirming to IS: 807, IS 3177 & IS : 3822 or latest IS complete all as specified and as directed.Note:- Span and long travel may vary slightly as per site conditions. |