Tender For Provn Of Trg Shed No 01 At Ima Dehradun; 1 SCHEDULE A PART-I (BUILDING WORK) 2 Construction of Block of Training Shed including Porch, Plinth Protection, Steel Truss with Galvalume Roof Sheet including all fittings and fixtures complete all as specified, directed and as shown on drawings. 3 Construction of block of Cycle Parking Shed, including Ramp, Plinth Protection, complete all as specified, directed and as shown on drawings 4 Construction of Block of Scooter Parking Shed including Ramp, Plinth Protection, complete all as specified, directed and as shown on drawings. 5 SCHEDULE A PART II-A (Internal Water Supply) for details refer Sch A in pdf folder 6 SCHEDULE A PART II-B (Internal Water Supply) 7 S & F two wayBib cock brass CP with wall flange quarter turn (low-flow) 15mmdia complete all as specified and directed.Make JAQUAR –QQT 7041, Kohler-16094IN-4-CP, Grohe - 20237001 8 S & F hand shower (health faucet) with 1 meter long easy flex tube in chrome finish and wall hook with NRV (back flow preventer) complete all as specified and directed.Make- JAQUAR -ALD573, Kohler-12927IN-CP, Grohe - 26352000 9 Supply and fix angle cock brass CP 15mm diacomplete all as specified and directed.Make JAQUAR-QQT7053,Kohler 76390IN-9-CP,Grove 2201100M 10 Supply and fixing pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for 15mm bore GI pipe, complete all as specified and directed.Make Jaquar- QQT7011, Kohler-26042 IN-4-CP, Grohe - 32813000 11 S & F Bib tap, cast copper alloy fancy type with cruth or butterfly handle screwed down, screwed for 15mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed. Make Jaquar- QQT7037, Kohler- 160931N4-CP, Grohe - 20237000 12 S & F Stop valves, cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type)screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed for following sizes 20mm dia.Make- Jaquar- QQT7083K,Kohler-16087IN-4-CP, Grohe - 2201100M 13 S & F Stop valves, cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type)screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed for following sizes 25mm dia.Make- Jaquar- QQT7083K,Kohler-16087IN-4-CP, Grohe - 2201100M 14 S & F Stop valves, cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type)screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed for following sizes 32mm dia. Make- Jaquar- QQT7083K,Kohler-16087IN-4-CP, Grohe - 2201100M 15 SCHEDULE A PART III-A (Internal Electrification) for details refer Sch A in pdf folder 16 SCHEDULE A PART III-B (Internal Electrification) 17 M & L for point wiring using 1.1 kV grade single core FR-LSH flexible cable, conforming to IS 694: 2010, having multi-drawn thin strands of electrolytic copper conductors and insulation for phase, neutral, and earth continuity conductor connecting to earth dolly, colour-coded as per IS 11353: 1985, drawn in medium grade UPVC surface / recessed conduits on surface/on truss including necessary saddle, fixing arrangements, conforming to IS 9537 (Part- 3): 1983, of size not less than 20 mm NB, including cutting chases, factory made not less than 1.2 mm thick sunken, modular flush sheet galvanized metal enclosure having zinc coating not less than 120 GSM, , conforming to IS 14772: 2000, 18 having top, bottom, side and back-wall knockouts for conduit entry from any direction, suitable modular cover-plates and making good of disturbed surfaces of wall / ceiling / floor, etc. complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. Notes[i] Wiring from the DB (distribution box) to switch shall be deemed inclusive in the quoted rates.[ii] Sunken modular flush sheet metal enclosures shall be deemed inclusive in the quoted rates.[iii] Modular cover plates shall be deemed inclusive in the quoted rates.(iv) Refer drawing for location of switch board , light fitting and other accessories. 19 One light point controlled by one switch, with cables 1.5 mm² size 20 One additional light point on the same switch, with cables 1.5 mm² size 21 One light point controlled by two 2-way switches, with cables 1.5 mm² size 22 One fan point controlled by one switch, with cables 1.5 mm² size 23 One exhaust fan point controlled by one switch, with cables 1.5 mm² size 24 One 6 A socket outlet, on the same board with other switches, with cables 1.5 mm² size 25 One 6 A socket outlet, independent, with cables 1.5 mm² size 26 One 16 A socket outlet, independent, with cables 2.5 mm² size 27 One 25 / 32 A socket outlet, independent, with cables 4 mm² size 28 S & F modular type 6 A 1-way SP switch conforming to IS 3854: 2012 with finger-proof terminal complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. 29 S & F modular type 6 A 2-way SP switch conforming to IS 3854: 2012 with finger-proof terminal complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. 30 S & F 3 pin, 6 A, 250 V ceiling rose conforming to IS 371: 1999 and having terminal capacity 3 X 1.5 mm² with IK 04 and IP 20 protection complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. 31 S & F modular type 16 A 1-way SP switch conforming to IS 3854: 2012 with finger-proof terminal complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. 32 S & F single pole & neutral, modular type, double door 4 way, metallic distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for DP RCCB / RCBO / Isolator / MCB as incomer and SP MCBs as outgoing, reversible metal door, 100 A copper busbar, fully shrouded neutral bar, earth bar, wire set & cable ties for cable management, pre fitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. Note [DP RCCB / RCBO / Isolator / MCB & SP MCBs shall be measured and paid separately. 33 S & F modular type 2/3 pin combined shuttered type 6 A socket, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. 34 S & F triple pole & neutral, 6 way modular type, double door, metallic distribution board, conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FP RCCB / RCBO / Isolator / MCB as incomer and SP/TP MCBs as outgoing, reversible metal door, 100 A copper busbar, fully shrouded neutral bar, earth bar, wire set & cable ties for cable management, pre fitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified in IS 732: 2019 and directed by the engineer-in-charge.Note FP RCCB / RCBO / Isolator / MCB & SP/TP MCBs shall be measured and paid separately. 35 S & F modular type 2/3 pin combined shuttered type 16 A socket, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. 36 S & F MCB 6- 32 A, 230 V, 50 Hz, SP MCB (C curve)for conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. 37 S & F modular type 3 pin 25/32 A socket, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. 38 S & F MCB 40- 63 A, 230 V, 50 Hz, FP MCB (C curve)for conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. 39 S & F modular type 25/32 A SP MCB, conforming to IS 60898- 1: 2002 complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. 40 M & L for earthing complete with GI earth plate electrode of 60 cm x 60 cm x 6 mm size, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GIwire of diameter 4.0 mm as earth lead, by means of bolts, buts, check nuts and washers of galvanised iron or steel, galvanized iron pipe of 15 mm diameter, connected to earthing test point, all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion and including excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep, with a 10 mm thick CI cover, hinged to CI frame on ground level, GI watering pipe, funnel, etc. complete all as specified and directed by the engineer-in-charge. 41 M & L for 4.0 mm diameter GI wire as earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. complete all as specified and directed by the engineer-in-charge. 42 S & F 20 W surface / wall mountedLED batten capable of delivering 2000 lumen, having PC diffuser, luminous efficacy of > 90 lumen/W, CRI > 80, PF > 0.9, CCT 6500K,independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed by the engineer-in-charge. 43 S & F 3-star (EEL) T-shape lamp capable delivering 1000 lumen having luminous efficacy of > 100 lm/W, starting time < 0.5 s, CRI > 80, CCT 6500K, PF >0.9, input voltage range 140- 270 V, input frequency 50- 60 Hz and B22 socket complete all as specified and directed by the engineer-in-charge. 44 S & F10 W mirror light, surface / wall mountedLED batten capable of delivering 1000 lumen, having PC diffuser, luminous efficacy of > 110 lumen/W, CRI > 80, PF > 0.9, CCT 6500K,independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed by the engineer-in-charge. 45 S & F 12 W surface mounted round shapeLED downlight capable of delivering 1200 lumen. having minimum luminous efficiency > 100 lumen/W, CCT 6500K, CRI > 80, high quality polycarbonate diffuser, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection complete all as specified and directed by the engineer-in-charge. 46 S & F 140 W High bay light duranto mounted LED,LED capable of delivering 14500 lumen,having minimum luminous efficiency > 105 lumen/W extruded aluminium housing with PC diffuser and integrated electronic driver with high efficiency long life LED chips, CRI ≥ 80, power factor ≥ 0.95, system luminous efficacy > 100, having average life 50000 hrs, operating voltage 140- 270, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the LED fitting including hanging arrangements from ceiling with SS chain 2 meter height complete all as specified and directed. 47 S & F 25 W street light having high efficiency long life LED module with SMD LED package mounted on MCPCB with high LED efficacy of ≥ 2600 lumen/W, integral SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, IP 66 protection, high effiency polycarbonate cover with integrated lens housed in pressure die-cast aluminium alloy heat sink for effective thermal management, sturdiness, excellent corrosion resistance, separate optical and control gear compartment & top opening for easy maintenance, suitable for side entry, pole mounting with bracket arm OD 35 mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer complete in all respect as specified and directed by engineer-in-charge. 48 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed by engineer-in-charge. Make 1) Havells Model No – HAVELLS GLAZE 1200mm BLDC,2) Orient Model No –ORIENT ELECTRIC ECO TECH PRO,3) Crompton Model No-ENERGION HS 1200mm 49 Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades, and frame and louvers complete all as specified and directed by engineer-in-charge.Make 1) Havells Model No – VENTIL AIR DB 300mm, 2) Orient Model No –ORIENT POWER FLOW 300mm, 3) Crompton Model No-.TRANS AIR 300mm 50 SCHEDULE A PART IV (Site Clearance and Earthwork) for details refer pdf folder 51 SCHEDULE A PART V A (Road, Path and Culvert) for details refer pdf folder 52 SCHEDULE A PART V B (Road, Path and Culvert) 53 M & L Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern,complete. all as specified and directed. 54 SCHEDULE A PART VI A (Area Drainage) for details refer pdf folder 55 SCHEDULE A PART VII A (Sewage Disposal) for details refer pdf folder 56 SCHEDULE A PART VII B (Sewage Disposal) 57 M&L for soakage well with size 1.8m dia x 3.0 m effective depth including excavation in any type of soil, foundation in PCC 1:3:6, walls of honeycombed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonry in Cement mortar, RCC cover slab in M-25, interconnecting pipes of RCC complete filled with brick bats complete all as specified and directed.and shown on drawing No GDBU22029/SP-01B Sheet 7/7 58 SCHEDULE A PART VIII A (External Water Supply) for details refer pdf folder 59 SCHEDULE A PART VIII B (External Water Supply) 60 Material and Labour for construction of Valve pit chamber of size 600 x 600 x 600 mm using PCC 1:4:8 type D-2 using 40mm graded stone aggregate for foundation 20cm thick, 23 cm stone wall in C.M (1:4) 15 mm thick rendering all around the stone work in CM (1:6), 75 mm thick PCC (1:2:4) type B-1 coping with 20mm graded stone aggregate including necessary form work for grouted including 3.15 mm thick MS top sheet cover with locking arrangement, MS frame made out of 40x40x6 mm angle iron including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer as finishing coat including demolition of existing valve chamber and clearing the debris complete all as specified and and directed. 61 Cutting cast iron/GIpipe up 150 / 100 mm bore, in position for insertion of new tees of size including jointing materials complete all as specified and directed 62 SCHEDULE A PART IX A (EXTERNAL ELECTRIC SUPPLY)for details refer pdf folder 63 SCHEDULE A PART IX B (EXTERNAL ELECTRIC SUPPLY) 64 Supply and Installof Tubular steel poles shall be swaged type & shall conform to IS 2713 (Parts 1 to 3) 1980.A through hole of 14 mm diameter shall be provided in each pole at a height of 300 mm above the planting depth for earthing arrangements. Finials and base plate shall be of cast iron and conform to the details given in fig. 3 and 4 of the Standard (I.S. 2713 Part 1 to 3-1980). Protection Against Corrosion The poles shall be coated with two coasts of black bituminous paint throughout internally and externally up to the planting depth. 65 The remaining portion of the exterior with two coat of emulsion paint including aluminium paint to GI bracket for street lightsand two coats of zebra marking with enamel from ground level and upto 1 mtr hight including white washing the coping and cleaningthe bushes surrounding the pole bottom upto 1 mtr width with CI base plate and finial taper plug, bolts, nuts & screws as specified type 410 SP 31,(9.0 Mtr long) complete all as specified and directed. 66 S&F fuse boxHot press moulded SMC junction box not less then 02 mm thick factory fabricated front openable duly painted and of size 300 X 250 X 100 mm having bakelite connector suitable for 3 phase and neutral link including MCB SP 6 amps gunmetal cable gland for LT cable fixed to pole with MS 25X3 mm GI clamps made to shape with required nut bolt washers etc. for street light fittingscomplete all as specified and directed. 67 M&L for earthingcomplete with usingusing Galvanised MS earth Plate (600 x 600 x 6mm) thick electrode and 32×6mm galvanised iron strip as earthing lead buried directly in ground, earth pit not less than 2.25 mtr deep below ground level with top edge of the earth plate not less than 1.50 m below ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to be packed thickness of 15 cm all round the plateusing 32x6mm galvanized iron strip as earth lead moulded and rivetted to earthplate at one end and connected to main equipment 68 at switch/control board at another end, copper earth leadprotected in and including 40 mm dia GI ‘medium grade’ pipe from upper end of earth plate upto equipment with & including 20 mm dia bore GI pipe ‘medium grade’ as water pipe from earth chamber to upper edge of the earth plate,GI funnel with wire mesh fixed on water pipe and provision of PCC 1:2:4 type B1(using 20 mm graded stone agg) as in pits chamber and RCC pit cover 50 mmthick of precast RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as per electrical plate No.3 of SSR Part-II 2010 and testing on complete all as specified and directed. 69 All as per item no 14.04 & 14.05above but for poles & other machinary equipments using 4 mm dia GI wire as earthing electrode as earth lead and MS galvanised plate of size 600 mmx600 mmx6mm as earth electrode complete all as specified and directed. 70 M & L for sub main wiring withPVC insulated unsheathed , 1100 Volts grade, copper cable2x2.5 sqmm stranded conductor and drawing through and including rigid PVC non metalic surface conduit of suitable size with conduit accessories such as junction boxes, bends, tees etc. including continus earth wire PVC insulated unsheathed 1100 volts grade,cable 2.5 sqmm copperconductor and connected to common earth dolly complete as directedNote :-(i) One run of PVC conduit two runs of cable and one run of earth wire shall be measured and paid as one unit. 71 Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all specified and as directed. 72 Supply, installation, commissioning and testing of factory made (CPRI approved) LT panel Board of Suitable size out door type (double door) 415 Volts, dust proof, vermin proof made out of CRCA sheet 3.15 mm thick duly compartmentalized inside panel with 2 mm thick CRCA sheet , to accommodate the incoming and outgoing each switch gear shall have be independent opening,and having provision for front and rear side opening with rubber beading, suitable size bus bar and mild steel cable glands for each cable to make it weather and vermin proof.double door hinged type,both side openable, air fins for ventilation, panel shall be mounted on ISMC Chanel of size (50 x 50 x 6 mm) 73 & duly spray paintedinternally and externally with two coats of synthetic enamel paint over a coat of red oxide primer supported on 04 legs suitable long each duly grouted in plaincement concrete blocks in 1:2:4 type B1 (using 20 mm graded stone aggregate) incl all connections incoming / out goingcomplete all as specified and comprising of following accessorycomplete all specified and as directed. 74 INCOMING : MCCB 4 Pole, 50 Amps ,415 Volt of breaking capacity 25 KAwith Adjustable Thermal and Adjustable Magnetic- 01 Nos.OUTGOING :MCB TPN, 415 V, 25Amps -02 NosMCB SPN, 240 V, 6 Amps -03 Nos Voltmeter (0.500) volts digital type with selector swwitch.-01 NoAmpere Meter (0-100) Amperes, 96mm square, digital type, CT connected with suitable CTs and selector switch-)1 NoPhase indicator, LED type, -each Set 75 Supply and fixing Air termination, single pointed aluminum rod 12mm dia and 300mm long complete all as specified and directed 76 Supply and fixing Test point terminal block made of gun metal or phosphorus bronze size (75x75x25) mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed 77 Supply and fixing Aluminum strip (25 x 3.15) mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed 78 Supply and fixing Galvanized Iron strip (25 x 3.15) mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed 79 SCHEDULE A PART X (AIR CONDITIONING, REFRIGERATION & WATER COOLER) 80 Supply, installation, commis-sioning of Water cooler fullystainless steel, electric driven single phase having approx storage and nominal cooling 120 ltr and nominal cooling capacity 60 ltrcomplete all as specified and directed. 81 Supply and fix voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V t0 250 V with output voltage stablized at 230 volt with accuracy +2.5 % and capacity 1 KVAcomplete all as specified and directed. 82 Supply and fix RO plant of out put capacity 25 ltr /hr complete all as specified and directed. 83 SCHEDULE A PART XI (STAND BY DG SET) 84 Supply and installation of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS 10001/10002 and alternator as per IS: 13364 complete with Relay Panel and switch Gear for Automatic starting on main failure and switch over on mains after restoration of main supply with AMF Panel , control panel having meter and sound proofas per CPCB norms and foundation etc (as per OEM design),of capacity 30 KVA complete all as specified and directed. 85 (A) The technical Specifications of Gen Set is comprising of the following accessories:-(a) Cooling SystemRadiator, Centrifugal Water Pump(b) Exhaust SystemExhaust Manifold, Flexible Pipe of Silencer, Residential Silencer(c) Fuel SystemFuel Pump, Fuel Injector, Fuel Filter 86 (B) Lub Oil SystemLub Oil Pump, Lun oil Filter, Lub oil Cooler( e)Air SystemAir Intake Manifold, Air cleaner Assembly(f) GovernorElectronic(g) Starting SystemElectric Starting-As per manufacturer recommendation, Battery Charging alternator, Wiring harness for connecting engine to control panelNote :- Refer Particular Specification (DG Set) for complete description such as Acoustic Enclosure, Base Frame, Performance parameters, Canopy Features, Thermal Insulation, Noise suppressor, all as specified