| 1 | Schedule-A (B/R Work) |
| 2 | Demolition of brick work built in cement mortar including all qoins, arches, pillars, etc.complete all as specified directed ny Engr-in-Charge. |
| 3 | M&L for Brick work with sub class B bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6 all as specified and directed by Engr-in-Charge |
| 4 | All as per srl item No. 2 here in before but except bricks .Note:- Serviceable bricks obatined from srl item No. 1 shall be re-used in srl item No. 3 after cleaning etc complete all as specified and directed by Engr-in-Charge. |
| 5 | M&L Gunitting work for RCCwork as in columns, beam,slab, perapet, chajjas etc by removing all loose concrete on thereinforcement, cleaning the surfaces with wire brushes and reinforcement with sand papers than applying apoxy paint to rusted reinforcement and S&F welded wire mesh fabric size not less than 95x95x3 mm on the prepare surfaces and finally applying guniniting 30 to 40 mm thick (average thickness )with presure gun using 1 part of cement and 3 part of coarse cement incl necessary form work where ever required all gunnited surface shall be brought in complete geometric figure even in the guniting opration only complete all as specified and directed.Note:- Where new or additional reinforcement is required the same shall be paid for separetaly of this schedule as above. |
| 6 | M&L washed stone grit plaster on exterior walls in two layers under layer 12mm cement plaster 1:4 (1cement 4coarse sand) furrowingthe under layer with scratching tool applying cement slurry @ 3kg/sqm top layer 15mm cement plaster 1:1/2:2 ( 1 cement 1/2 coarse sand : 2 stone chipping coloured 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing & washing the top layer with brushes & water to expose the stone chipping and taking down old grit plaster complete all as specified pattern decided by Engr-in-Charge.(payment for providing grooves shall be made separately).Note:- Top layer of shade be of white cement using colouring pigment & stone chipping of desired colour as approved. |
| 7 | Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge |
| 8 | M&L TMT bar mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed by Engr-in-Charge. |
| 9 | All as per item No 07 here-in-before but but 6mm to 8mm dia all as per specified and directed by Engr-in-Charge. |
| 10 | Taking down cement plaster, any description on brick walls or on concrete surfaces including racking out Joints, hacking for Key, scrubbing down with Water, etc., and removing same from the Site(s), complete all as specified and as directed. |
| 11 | M&L for rendering 5 mm thick in cement mortar 1:3 on ceilingon concrete surfaces, finished fair & even without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 12 | M&L for rendering 15 mm thick in cement motar 1:6 on brick work or concrete surfaces other than fair face of brick work, finished fair & even without using extra cement all as specified and directed by Engr-in-Charge. |
| 13 | M&L new plasteredsurfaceapplying two coat of acrylic emulsion paintover one coat ofprimer andone coat of JK/Birla Cement putty cement base puttyall asspecifiedand directed by Engineer-in-Charge |
| 14 | Preparing New Plastered Surfaces of WALLS and applying TWO COATS of DISTEMPER OIL EMULSION (OIL BOUND WASHABLE DISTEMPER) over a Coat of CHALK WHITING, complete all as specified and as directed. by Engineer-in-Charge. (Note:- work will be strictly executed by mechinised means/ tools as required for smart periodical services) |
| 15 | Preparation of new plaster surfaces of ceiling, and applying two coat of white wash on ceiling all as directed by Engr-in-Charge. |
| 16 | M&L for Complete removal of existing treatment upto plastered surfaces includingpreparation of old decorated surfaces of walls and cornices and applying two coat ofexterior grade acrylic emulsion paintover one coat ofcement base puttyall asspecifiedand directed by Engineer-in-Charge |
| 17 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets all as specidfied and directed by Engr-in-Charge. |
| 18 | S&F 8 to 10mm thick densified reqular edged eco friendly light weight calcium silicate false ceiling tiles size 600x600mm including main \"T\" runner of size 24x38mm made from 0.33 mm sheet hot deep galvanized steel sectionmaking good existing frame without disterbing the other false ceiling with all as directed by Engr-in-Charge. |
| 19 | S&F in repair 8 to 10mm thick densifed regular edged eco friendly light weight calcium silicate false ceiling tiles size 600x600mm without disterbing the other false ceiling and making good existing frame with all as specified and directed by Engr-in-Charge. |
| 20 | S&F 4 to 5 mm thick plain AC Boards as in false ceilling with three coat of white wash and making to good existing frame without disturbing the other false ceilling board complete all as specified. |
| 21 | S&F Solid PVC Wall Liningconsisting of 5mm thick plain /wood grain printed colour PVC sheet inclusive of solvent cement & fixing at site on PVC frame as per specification & drawing |
| 22 | S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing |
| 23 | S&F in repairs 25mm dia 16 gauge Aluminiumpowder coated curtain rods with sides designer pattern wall bracket & knobs/domes suitable for 25mm dia curtain rods including cutting and fixing complete all as specified and as directed by Engr-in-Charge |
| 24 | S&F in repair 18/19 mm thick prelaminated particle boardinterior gde prelaminated one side with decorative choice and other side white lamination fixed with screws as in cup board shutters & shelves and pelmet boxes inculding beading etc all as directed. |
| 25 | S&F in repair 25 mm thick Block board interior Gde 2 quality commercial type decorated face veneer on one face fixed with screws as in cup board shelves etc all as directed. |
| 26 | S&F in repair aluminium alloy door seal 1m longfixedto wooden doors completeall as specified and as directed by Engineer-in-Charge. |
| 27 | S&F in repair, Mortice latch with two levers (vertical type), mild steel body and fixed (length of latch 100mm) completeall as specified and as directed by Engineer-in-Charge. |
| 28 | S&F in repairISI marked hydraulically regulated door closer aluminium (extruded section)body type complete suitable for door shutter width upto 1.50 mtr and weight between 61 to 80 kg completeall as specified and as directed by Engineer-in-Charge. |
| 29 | Dismantling ofwall/ floor tile including backing coat any description or any thickness led beded and pointed in any cement motar and removal to out of MD land. |
| 30 | M&L glossy chequered cement concrete tiles 300x300x25mm thick, set jointed and pointed in near cement slurry in floors with white cement and pigments in any colour machine preassed glazed , over cement screed bed 15mm thick cement motor 1:6 all as specified and as directed by Engr-in-charge. |
| 31 | M&L for glazed ceramic coloured designer concept tiles matching with existing tile 350x250x7 or 450x350x7mm size as in walls set and jointed in neat cementslurry over 10mm thick recuing in cement mortar (1:4) and pointed in coloured cement to match for work on vertical surface such as skirting dado etcall as specified and as directed by Engr-in-Charge. |
| 32 | M&L non skid ceramiccoloured tile 7 to 8mm thick (square/rectangulararea of each tilesexceeding 0.11 Square but not exceeding0.18 Sqm in floor over 15mm thick screed bed in cementmotar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match the tile all as directed by Engr-in-Charge. |
| 33 | S&F 18 to 20 mm thickgranite (any type) machine cut laid over cement screed bed 15 mm thick in cm 1:6 and jointed in grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including mirror polishing and bull nosing edging in any position etc all as directed by Engr-in-Charge. |
| 34 | M&L 20-25 mm thick machine cut Kota stone slab flooring over cement screed bed15mm thick in CM 1:6 and jointed with gray cement slurry mix with pigment to match the shade of slab including rubbing and polishing complete all as directed by Engr-in-Charge. |
| 35 | Taking down corrugated steel sheeting,any gauge,thickness including nainital or similar pattern roof covering complete all as directed by Engr-in-charge. |
| 36 | S&F 0.5 mm thick pre coated thick galvalume aluminium zink coated GI based corrougated steel sheeting of any colour having tensile strength of 550 MPA as in roof covering/glading to wall fixed with self tapping screws, complete all as specified and directed by Engr-in-Charge. |
| 37 | M&L post construction ATT along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron.complete all as specified and directed by Engr-in-Charge |
| 38 | M&L post construction antitermite Treatment of soil under existing floors using emulsion @ one litre per litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement :2 coarse sand) to match the existing floors complete all as specified and directed by Engr and Charge. |
| 39 | Demolition in cement concrete in any description and any position not other wise specified and provided as in ground floor and paving nexc. 15 cm thickness (below above ground floor) all as directed by Engr-in-Charge. |
| 40 | M&L for cement concrete 1:3:6 type C-1 (20mm graded stone aggregate) 75 mm thick in plinth protection and courtyard, finished cement surfaces even and smooth with out using extra cement , completeall as specified and as directed by Engineer-in-Charge. |
| 41 | M&L providing 75mm thick cement concrete 1:4:8 type D-2 using 40mm graded aggregate in sub base of floor complete all as specified and directed by Engr-in-Charge. |
| 42 | Dismantling structural steel work incl. steel door, gate, window guard bars, grills etc. |
| 43 | M&L fabricated frame work as in doors /windows frame using MS Box section of required size for making rebate to fix Shutter and other section with gusset plate rails, braces etc. complete drilled for fixing Door Shutter with MS Butt Hinges and hole for tower bolt, sliding boltetc or other covering door etc to be prepared for hanging with and including hinges all as specified and as directed. |
| 44 | M&L for mild steel works as in grills and railing of Fe-410-0or Fe 310-0, complete all as specified and as directed by Engr-in-charge |
| 45 | M&L PCC for1:2:4 type B-1 (using 20mm graded stone aggregate) as in coping, benching & for fixing railing, holdfast etc complete. |
| 46 | S&F Pressed steel frames size of 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified by Engr-in-Charge. |
| 47 | S&F in repair 4.0mm thick sheet glass plain pane best quality fixing to Aluminium/Steel/wooden Sections as in Panel of Doors/Windows/Ventilator and Panelling Works with necessary fixing Arrangements viz Jointing Cleats, Glazing Clips, Rubber Packing, Screws, etc. or fixed with Oil Putty, as required/ordered at Site(s), complete and fixed all as specified and as directed. |
| 48 | S&F in repair 4.0mm thick Glass pane figured pin headed type, best quality, fixing to Aluminium/Steel Sections as in Panel of Doors/ Windows Shutters and Panelling Works with necessary fixing Arrangements viz Jointing Cleats, Glazing Clips, Rubber Packing, Screws, etc. or fixed with Oil Putty, as required/ordered at Site(s), complete and fixed all as specified and as directed. |
| 49 | M&L Preparation of new steel surface exc 10 cm width/girthapplying two coat synthetic enamel paint over one coat of red oxide primerall as specified and directed by Engineer-in-charge |
| 50 | Taking down chowkats or frames exc 1.5 sqm but n exc 4 sqm each with shutters (withour taking off shutters from the frame all as specified and directed by Engr-in-Charge. |
| 51 | Taking down Chowkhats or frames n exc 1.5 Sqm each without taking off shutter from the frame all as specifed and directed by Engr-in-Charge. |
| 52 | S&F 30mm thickfactory made flush door shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides all as specified and directed by Engr-in-Charge. |
| 53 | M&L second class hardwood 35mm thickness plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers; supplied and fitted to chowkats all as specified and directed by Engr-in-Charge |
| 54 | M&L second class Hardwood 35 mm thickness, glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified by Engr-in-Charge. |
| 55 | Preparation of new woodensurfacesof anydescriptionnot otherwise described, over10 cm widthor girth and applying two coat of synthetic enamel paint over one coat of pink wood primer all asspecifiedand directed by Engineer-in-Charge. |
| 56 | S&F stainless steel bright polished barrel tower bolt with plate with 10mm dia of shoot and 200mm long all as specified directed by Engr in Charge. |
| 57 | S&F 125 mm long medium grade stainless steelbutt hinges bright polished fix to steel chowkhat with nut and bolt all as specified directed by Engr in Charge. |
| 58 | S&F 250mm long, 16mm dia stain less steel bright polished door sliding bolt hasp and staple type with fixing of clips 3 Nos with fixing with nut & bolt all as specified directed by Engr in Charge. |
| 59 | S&F stain less steel bright polished bow handle solid type 150mm grip length fency type all as specified directed by Engr in Charge |
| 60 | S&F two legged aluminium floor door stopper with rubbershoe 140mm longcomplete all as specified and directed. |
| 61 | S&F in repair stainless steel wire cloth with 8% nickle 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple |
| 62 | S&F polyester powder coated aluminium frame/chowkhat for door shutter of section 101.0x44.4 mm of gauge 16 fixed in brick masonery or conrcrete work by necessary drilling and rawl plug aggangement etc incl polyester powder powder coated aluminium door shutter top rain and middle rail of section 85x44.4 of 16 gauge and bottomrail of section 150x44.4 mm 16 gauge (all section of such type having arrangement for fixing glass/prelaminated board on one or both sides as required) incl aluminium fittings such handle (2 Nos each shutter), tower bolt, locks (mortise type lock) glazing clips, rubber packing, anodised aluminium snap beading screw, hinges type B-21 150mm long (3 Nos each shutter) etc and one door stopper two legged with each leaf (shutter) complete (Glass and prelaminated board to be measured separately under appropriate item of sch A) complete all as specified and directed by Engr-in-Charge (Make of aluminium section shall be hindalco/Jindal and equvalent) |
| 63 | S&F polyester powder coated aluminium frame/chowkhat for window/ ventilator of section 63.5x38.1 mm of16 guage fixed in brick masonery or conrcrete work by necessary drilling and rawl plug aggangement etc incl polyster powder coated of any colour anodised aluminium window & ventilator shutters side hung type without sash bars aluminium with section 44.4x44.4mm of 16 guage including necessary jointing cleats, glazing clips, rubbers packing powder coated anodised aluminium snap beading, screw, powder coated aluminium anodised fittings such as peg stays 150mm long (1Nos), Hinges type B-21 100mm long (2Nos) suitable handle 1 Noscomplete all as specified and directed by Engineer-in-Charge. |
| 64 | M&L, for 12 mm thick pre-laminated particle board, exterior grade, pre-laminated on both side with decorative choice laminations fixed between aluminium section with and including snap fitting aluminium clips of polyester powder coated along with the glass with rubber gasket, complete all as specified and directed by Engr-in-Charge. Make. Anchor/Kitply/Novapan |
| 65 | S&F in repair aluminium anodized grillincluding aluminium beads etc complete all as specified and directed by Engr-in-Charge |
| 66 | S&F 5.5 mm thick tinted glass of selected quality fixed to aluminium frame of any section as in item here-in-before incl snal fit aluminium clips of polyester powder coated along the glass with rubber gasket complete all as specified and directed by Engr-in-Charge. |
| 67 | Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C\" channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and wood grain printed PVC Sheet used 5mm thick x 15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beaading of 10mm x 10mm used instead of exposed portion of PVC sheet beading for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; supplying & fixing in the frame at site as per specification & drawing all as specified and directed by Engr-in-Charge. |
| 68 | Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing all as per specified and directed by Engr-in-Charge. |
| 69 | S&F in repair 600mm x 450 mm bevelled edge mirror of selected quality glass mounted on 6 mm thick fixedon wall with wooden plugs with chromium plated brass screw & cup washer completeall as specified and as directed by Engineer-in-Charge. |
| 70 | S&F in repaircorner glas shelf 10mm thick,200mm quarter round , as bull nosedfixed with stainless steelbracketsteel screw in corner shelfall as specified and directed by Engr-in-Charge. |
| 71 | S&F in repair vertical blinds for windows/door/ventelator of any colour and pattern as approved by Engr-in-Charge including connected items ie. rod, hook etc and completefitting all as specified and as directed by Engineer-in-Charge. |
| 72 | Supply and fixing factory made uPVC white colour Three track three panels sliding window with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead /double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multi-chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge. |
| 73 | Taking down existing bitumen felt roof treatment including cement mortar bedding and cleaning the surface and removal outside the MOD land, complete all as specified and directed. |
| 74 | M&L PCC (1:2:4) type B-1, using 20 mm graded mechanically crushed stone aggregates as in padding to roof to maintain the required slope and finished the surface even and smooth without using extra cement, complete all as specified and directed. |
| 75 | Material and labour, 10mm thickcement plaster in CM (1:4) mixed with WPC as per manufacturer’s instructions on concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. Note : WPC shall be measured and paid separately. |
| 76 | M&L water proofing treatment of roof consisting as under:- (a) Applying evenly a coat of bituminous primer conforming to IS-3384:1986 @ 0.30 litre/sqm including preparation of roof surfaces (b) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg/Sqm on plaster surface all as specified.(c) A layer of 3mm thick APP polymeric membrane of weight not less than 3.60 kg/sqm, reinforced with polyester non-woven fabric (weight not less than 160gm/sqm), duly sealed at over laps & joints with end laps of the 10cm and side over laps of 7.5cm by flame (by torch application) all as per manufacturer’s instructions, complete all as specified and directed. |
| 77 | Supply only water proofing liquid compoundcomplete all as specified and directed by Engr-in-Charge. |
| 78 | M&L Applyingone coat ofaluminium heat resistance painton the roof as per manufacture instructions complete all as specified and directed by Engr-in-Charge. |
| 79 | M&L for Toughned glass 12 mm as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required complete all as specified & directed by Engr-in-Charge . |
| 80 | Note:- The amount of Rs 66090/- against Schedule of Crediton Srl Page 144 shall be deducted from the total amount quoted against Sch \"A\" |