| 1 | Taking up cast iron water mains (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead and removal from site complete all as specified and directed for following bores:- |
| 2 | Cast Iron (CI) Pipe 200 mm bore |
| 3 | Cast Iron (CI) Pipe 150 mm bore |
| 4 | Cast Iron (CI) Pipe 100 mm bore |
| 5 | M&L for 200mm bore DI pipeswith spigot and socket ends suitable for tyton joints, centrifugally cast, class K-9,ISI Marked,in any length coforming to IS: 8329 (2000) as per latest amendments, laid in trenches with &including EPDM rubber gasket (Tyton joint) and testing on completion complete all as specified and directed.Note:- Excavation and earth work shall be measured and paid separately under respective items of BOQ. |
| 6 | M&L for 150mm bore DI pipeswith spigot and socket ends suitable for tyton joints, centrifugally cast, class K-9,ISI Marked,in any length coforming to IS: 8329 (2000) as per latest amendments, laid in trenches with &including EPDM rubber gasket (Tyton joint) and testing on completion complete all as specified and directed.Note:- Excavation and earth work shall be measured and paid separately under respective items of BOQ. |
| 7 | M&L for 100mm bore DI pipeswith spigot and socket ends suitable for tyton joints, centrifugally cast, class K-9,ISI Marked,in any length coforming to IS: 8329 (2000) as per latest amendments, laid in trenches with &including EPDM rubber gasket (Tyton joint) and testing on completion complete all as specified and directed.Note:- Excavation and earth work shall be measured and paid separately under respective items of BOQ. |
| 8 | Taking up or down old unserviceablesteel tubing and connections including removal from site complete all as specified and as directed in respect of followings:-Note:- Excavation and earth work wherever required shall be measured andpaid for separately under respective items of BOQ. |
| 9 | GI steel tubing 50 mm bore |
| 10 | GI steel tubing 40 mm bore |
| 11 | GI steel tubing 25 mm bore |
| 12 | GI steel tubing 20 mm bore |
| 13 | GI steel tubing 15 mm bore |
| 14 | Supply & fix medium grade galvanised steel water tubes with all fittings such as bends, elbows, tees, short pieces, union etc and fixed complete to walls and ceilings or laid in trenches/floors complete all as specified & directed in respect of followings:-Note:- Excavation and earth work, wherever required, shall be measured and paid separately under respective items of BOQ. |
| 15 | GI steel tubing 15 mm bore |
| 16 | GI steel tubing 20 mm bore |
| 17 | GI steel tubing 25 mm bore |
| 18 | GI steel tubing 40 mm bore |
| 19 | GI steel tubing 50 mm bore |
| 20 | Supply and fix, in replacement, cast iron sluice valves 200 mm bore, class PN-1.6,conforming to IS-14846, both end flanged with stainless steel spindle, GM nut & CI wheel including making flanged joints with & including minimum 3mm thick rubber sheet, nuts & bolts etc of suitable size complete all as specified and directed. |
| 21 | Supply and fix, in replacement, cast iron sluice valves 150 mm bore, class PN-1.6,conforming to IS-14846, both end flanged with stainless steel spindle, GM nut & CI wheel including making flanged joints with & including minimum 3mm thick rubber sheet, nuts & bolts etc of suitable size complete all as specified and directed. |
| 22 | Supply and fix, in replacement, cast iron sluice valves 100 mm bore, class PN-1.6,conforming to IS-14846, both end flanged with stainless steel spindle, GM nut & CI wheel including making flanged joints with & including minimum 3mm thick rubber sheet, nuts & bolts etc of suitable size complete all as specified and directed. |
| 23 | Supply and fix, in repairs, gun-metal, globe or gate valves, ISI marked, with iron wheel head, screwed both ends for iron pipe and fixed, for 50 mm bore dia of pipe complete all as specified and as directed . |
| 24 | Supply and fix, in repairs, gun-metal, globe or gate valves, ISI marked, with iron wheel head, screwed both ends for iron pipe and fixed, for 40 mm bore dia of pipe complete all as specified and as directed . |
| 25 | Supply and fix, in repairs, gun-metal, globe or gate valves, ISI marked, with iron wheel head, screwed both ends for iron pipe and fixed, for 25 mm bore dia of pipe complete all as specified and as directed . |
| 26 | Supply and fix, in repairs, gun-metal, globe or gate valves, ISI marked, with iron wheel head, screwed both ends for iron pipe and fixed, for 20 mm bore dia of pipe complete all as specified and as directed . |
| 27 | Material and labour for cutting, drilling and taping cast iron / Ductile iron water mains (in position) for branch connection of the internal dia 150 to 200 mm including necessary fittings such as ferrules, nipple short pipe etc complete all as specifiedand directed. |
| 28 | S & F of CI/DI fittings i.e. bends (any type, radius and angle), tapers any type (straight, bend increasing, decreasing or double socket etc), T-pieces single branch, \"Y\" junction double branch, cross (all sockets or socket and spigot), collars, caps and plugs etc suitable for & upto 200 mm bore pipes complete all as specified and directed. |
| 29 | Drilling (Horizontally) to existing road (maximum 10M wide) suitable for passing GI tubing of dia upto 80mm/ 100mm as required at site complete all as specified and directed.Note:- All necessary T&P required at site for drilling shall be arranged by contractor at his own cost and quoted rate shall be deemed to be included for all these provisions and nothing extra shall be paid on this account. |
| 30 | M&L for construction of new valve pit/ chamber of single brick masonry using old size bricks in CM (1:4) of size 1000mmx 1000mmx 1000mm (internal dimensions) including PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate as in foundation & floor (min 150mm thick), internal, external & floor plaster, PCC coping, 5mm thick MS sheet cover with 50x50x6mm MS angle iron frame with locking arrangement including painting two coats of synthetic enamel paint over a coat of red oxide primer and necessary excavation & earth work in any type of soil and removal complete all as specified in respective clause of PS part-II and as shown & specified in details in TD Drg No. CEJZ/TD/819/91 sheet 1/1 dt 16/04/1991 after demolition of existing old unserviceable valve pit chamber complete all as directed. |
| 31 | M&L for construction of new valve pit/ chamber of single brick masonry using old size bricks in CM (1:4) of size 900mmx 900mmx 900mm (internal dimensions) including PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate as in foundation & floor (min 150mm thick), internal, external & floor plaster, PCC coping, 5mm thick MS sheet cover with 50x50x6mm MS angle iron frame with locking arrangement including painting two coats of synthetic enamel paint over a coat of red oxide primer and necessary excavation & earth work in any type of soil and removal complete all as specified in respective clause of PS part-II and as shown & specified in details in TD Drg No. CEJZ/TD/819/91 sheet 1/1 dt 16/04/1991 after demolition of existing old unserviceable valve pit chamber complete all as directed. |
| 32 | M&L for construction of new valve pit/ chamber of single brick masonry using old size bricks in CM (1:4) of size 600mmx 600mmx 600mm (internal dimensions) including PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate as in foundation & floor (min 150mm thick), internal, external & floor plaster, PCC coping, 5mm thick MS sheet cover with 50x50x6mm MS angle iron frame with locking arrangement including painting two coats of synthetic enamel paint over a coat of red oxide primer and necessary excavation & earth work in any type of soil and removal complete all as specified in respective clause of PS part-II and as shown & specified in details in TD Drg No. CEJZ/TD/819/91 sheet 1/1 dt 16/04/1991 after demolition of existing old unserviceable valve pit chamber complete all as directed. |
| 33 | Excavationin trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, for laying of pipe, cable etc or n. exc.10 Sqm on plan and n. exc. 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in hard/dense soil complete all as specified and directed. |
| 34 | Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed. |
| 35 | Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 36 | Cutting the existing PCC/bituminous road of any description to a size not exc. 0.5m wide x 1.0m deep for crossing of pipe including refilling, ramming and makinggood top 100mm thick surfacewith and includingplain cement concrete (1:3:6) type C1 using 20mm graded stone aggregate complete all as specified and directed. |
| 37 | Schedule of credit amount of Rs 20,61,650.00 to be deducted during AOC |