Provision Of Solid Waste Management Plant At Rms; 1 Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. 2 Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft and loose soil etc complete all as specified and as directed. 3 M&L for Cement Concrete (1:4:8)Type D-2(using 40mm graded crushed stone aggregate) as in foundation filling/ mass concrete complete all as specified and as directed. 4 M & L for RCC (Nominal Mix) (1:1.5:3) type B-1 (using 20mm graded crushed stoneaggregate) as in Foundations, including rafts,footings, foundation beams;plinth beams; bases for columns, etc.; basement slabs,under-reamed piles and mass concrete complete all as specified and as directed 5 M & L forRCC (Nominal Mix) (1:1.5:3) type B-1 (using 20mm graded crushed stoneaggregate) as in columns, pillars, piers, posts and struts complete all as specified and as directed 6 M&L for RCC (Nominal Mix) (1:1.5:3) type B-1 (using 20mm graded crushed stone agg) as in beams, cantilvers, bressummers, lintels over 1.5m span complete all as specified and as directed 7 M&L for TMT bars 10 mm dia and above, as in reinforcement for concrete, cut to length, bent to shape required including cranking , bending , hooking ends and binding with and including mild steel wire(annealed) not less than 0.9 mm etc complete all as specified and directed. 8 M&L for TMT bars 6 to 8mm dia , cut to length, bent to shape required including cranking , bending spirally for hooping for columns, hooking ends as in stirrups, spacers, binders etc and binding with and including mild steel wire(annealed) not less than 0.9 mm or securing with clips etc complete all as specified and directed. 9 Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed. 10 Use and waste of formwork to sides of pillars posts, struts, piers, columns and stanchions finished the suface rough. 11 M&L for hardcore of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammmed to a true surface complete all as specified and as directed. 12 M & L for Mild steel work in tubular trusses including special shaped washer etc complete in using ERW or induction butt welded tubes confirming to IS 1161-1979 grade St-240 including painted one shop coat of zinc chrome primer paint including preparation of surface before fabrication complete all as specified and as directed. 13 M&L for cement concrete type B-1 (1:2:4) (using 40 mm graded stone aggregate) 100 mm thick in paving complete all as specified and as directed. 14 M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe 410 -W (Gde-E- 250) quality-A and painted one shop of zinc chrome primerincluding preparation of surface before fabrication complete all as specified and as directed. 15 S&F Plates (plain or chequered) channels. Square cut or notched ) (ordinary and counter sunk) forming holes, without any attachment of Fe-410-W (Gde-E-250 quality-A)complete all as specified and directed. 16 S&F for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,exc 22.5 cm but n exc 30cm long and 16 to 20mm dia of neckcomplete all as specified and directed. 17 Use and waste of formwork to sides and soffits of floors or roof beams, beams haunchings, girders,bressummers lintels, cantilevers, shelves including supports overhangs etc also splays between floors and beams complete all as specified and as directed 18 M&L for brick work with sub class `B bricks (using old size burnt bricks) straight or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and as directed 19 M&L for Machine cut kota stone slab flooring 20-25mm thick ,laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete laid over and including 20mm thick screed bed in CM (1:3) complete all as specified and as directed. 20 M & L rendering 15mm thick in cement mortar (1:4) on fair faces of brick or concrete work finished even and smooth without using extra cement complete all as specified and directed. 21 M & L rendering 5mm thick in cement mortar (1:4) on fair faces of brick or concrete work finished even and smooth without using extra cement complete all as specified and directed. 22 M&L for 75 mm thick PCC (1:3:6) type C2 , using 40 mm graded stone agg in plinth protection/aprons/path laid to slope of 1:12, finished fair and even without using extra cement with and including all necessary formwork to divide tha area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 10 mm wide joints throughout thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and directed 23 M&L for preparation of new steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide primer all as specified & directed 24 S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roofcovering /cladding to wall, fixed with self tapping screws etc complete all as specified and directed. 25 S&F 0.63Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, dripand straight flashings (length and girth asfixed) with grade ofzinc coating 275 complete all as specified and as directed. 26 M&L for preparation for newly plastered surfaces and applying two coats of white wash complete all as specified and as directed 27 Returning, filling in, including spreading, leveling, watering & well ramming in layer s not exc 25 cmcomplete all as specified and as directed. 28 Removing excavation material n exc. 50m & deposited where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed. 29 Supply, Installation & testingEnvironmental Friendly Waste Disposal Incinerator system comprising as specified and as directed of followings : - (i) Biofics Organic Waste Composting Machine - Model/Make BF 500, Capacity 500Kg/Day, automatic type, microbes supported composting on high temp based, biomass retention period 3-4 days, compostting cycle time 24 hrs, Brim Capacity 2000Litre, Waste mixing chamber/composting tank ss 304 (min 3 mm thickness sheet), mixing Blades ss 304 (Min 16 paddles with tampered) periodical rotation at low RPM, outer body ss 304, shredder shaft double shaft high strength 4140 alloy steel shredder with capacity 400-500kg/ht x 2 , 13 blades 13 spacers ss 304, MS channel structure frame with inbuiltcontrol panelPLC based (Makes for panel, motor & Heater :L&T/schneider/Siemens/ABB/Havells/kirloskar/crompton), Effluent Bloweer 0.50KW, Effuent filtrationMOC ss 304 body and internal piping, agitaor motor power 5 HP, shredder motor 3 HP, compact gear box, Both auto and manual mode, door sensors, temp sensors, moisture sensors, bacteria culture provided for first generation and booosing in future, 30% moisture organic compost, volume reduction should be more than 85%, 01 year electric, 2 year mechanical on site warranty incl 01 yearAMC. (ii) Biofics incinerator Unit BI 50 KgElectric incinerator, Muncipal solid waste, Capacity 50 Kg/Hr, mode of heating electric and manual feeding and ash removal. 30 item 29.00 Contd..(iii) Biofics Canveyor Belt-Clint bucket type conveyor, capacity 500 kg/Hr,inbuilt disintegrated control panel, Main motor 2 HP, Minimum 10 ft lenth and 2 feet width, all contact surfaces SS and EN Non - contact surface SS & MS Powder coated and fixed with organic waste composting Machine. (iv) Biofics organic waste shredder :-(a) waste processing capacity per Hr -100-200 kg/hr (b) Appx Dimension ( in feet) ( L x H x W) -3 x 3 x 5 Feet (c ) Power Consumption per hr -1.5 KW appx (d) Motor with planetary Grear Box -03 HP (e) Motor Make -ABB/CG/Bharat Bijili/Havells (f) all contact surfaces SS and EN Non - contact surface SS & MS Powder coated(g) 01 year electric, 2 year mechanical on site warranty incl 01 yearAMC, 18 inch blades, PET, PP, PVC, HPE, LDPE, Nylon ABS etc, inbuilt disintegrated panel. 31 item 29.00 Contd..(v) Biofics Plastic waste shredder :-(a) waste processing capacity per Hr -100-200 kg/hr (b) Appx Dimension ( in feet) ( L x H x W) -3 x 3 x 5 Feet(c ) Power Consumption per hr -1.5 KW appx (d) Motor with planetary Grear Box -03 HP (e) Motor Make -ABB/CG/Bharat Bijili/Havells (f) all contact surfaces SS and EN Non - contact surface SS & MS Powder coated (g) 01 year electric, 2 year mechanical on site warranty incl 01 yearAMC, 18 inch blades, PET, PP, PVC, HPE, LDPE, Nylon ABS etc, inbuilt disintegrated panel.