}

Tender For Special Structural Repair And Retrofitting Work In Rajasthan High Court Building, Jodhpur (Fire Detection) - Sitc Of Ul 10Th Edition / En54 / Vds Certified Automatic Floating Sensitivity Type Analog Addressable Multi Criteria (Two Optical/Smok, jodhpur-Rajasthan

Rajasthan State Road Development And Construction Corporation Limited has published Tender For Special Structural Repair And Retrofitting Work In Rajasthan High Court Building, Jodhpur (Fire Detection) - Sitc Of Ul 10Th Edition / En54 / Vds Certified Automatic Floating Sensitivity Type Analog Addressable Multi Criteria (Two Optical/Smok. Submission Date for this Tender is 27-05-2025. Structural Work Tenders in jodhpur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

49257433
Tender For Special Structural Repair And Retrofitting Work In Rajasthan High Court Building, Jodhpur (Fire Detection) - Sitc Of Ul 10Th Edition / En54 / Vds Certified Automatic Floating Sensitivity Type Analog Addressable Multi Criteria (Two Optical/Smok
Tender
Indian
Rajasthan
Jodhpur
27-05-2025

Tender Documents

Tender Details

Tender For Special Structural Repair And Retrofitting Work In Rajasthan High Court Building, Jodhpur (Fire Detection) - SITC of UL 10th edition / EN54 / VDS certified Automatic Floating Sensitivity type Analog addressable Multi criteria (two optical/Smoke sensor to reduce false alarm) detector with mounting base & LED etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . And Also Following the guideline of Fire Safty Audit Report Issue By CE PWD Jodhpur SITC of Response Indicator for indicating the activation of the Remotely located Detector for Addressable type Detectors Etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . And Also Following the guideline of Fire Safty Audit Report Issue By CE PWD Jodhpur SITC of UL 10th edition / EN54 / VDS certified Analouge Addressable type Multi criteria (Heat & smoke) Beam detector along with interface module having a coverage area with a distance of min. 10 m and max. 100 m ,Operating temperature range: -20 C to +55 C, Response sensitivity of 40% , shall UL/EN54 certification including transmitter and receiver unit with mounting base & LED etc including the cost of all accessories, mouting arrangement Etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . And Also Following the guideline of Fire Safty Audit Report Issue By CE PWD Jodhpur Supplying and drawing Fire Resistant flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for cables. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . And Also Following the guideline of Fire Safty Audit Report Issue By CE PWD Jodhpur 2 x 1.5 Sq.mm Armoured With Outer Sheath in Red Color SITC of EN / LPCB/ UL listed / approved conventional automatic fire Alarm Rate of Rise cum fixed temperature thermister type Heat Detectors , 12 / 24 volt D.C., visual alarm indicator (LEDs) Blink - green in stand by and Steady - red in alarm complete in all respects with base as required.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . And Also Following the guideline of Fire Safty Audit Report Issue By CE PWD Jodhpur SITC of UL 10th edition / EN54 / VDS certified Addessable Manual Call point (MCP) with LED / FIRE Indication Etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . And Also Following the guideline of Fire Safty Audit Report Issue By CE PWD Jodhpur SITC of UL 10th edition / EN54 / VDS certified Addressable sounder with strobe light, Loop Powered / Direct powered from FACP with sound level 90 dB and programmable from the panel etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . And Also Following the guideline of Fire Safty Audit Report Issue By CE PWD Jodhpur SITC of Response Indicator for indicating the activation of the Remotely located Detector for Addressable type Detectors Etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . And Also Following the guideline of Fire Safty Audit Report Issue By CE PWD Jodhpur SITC of UL 10th edition / EN54 / VDS certified Addressable control (input/output) modules/ Relay Module for shutting down lifts, Hooters, AHUs, Acknoledgement of Sprinkler system with potential free contact monitoring Etc. as Required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .And Also Following the guideline of Fire Safty Audit Report Issue By CE PWD Jodhpur SITC of UL 10th edition / EN54 / VDS certified Microprocessor based inteligent, Analogue addressable,modular, expandable networkable loop Fire Alarm Control Panel with each loop capacity of min 125 detectors per loop with total of 125 detectors & devices with Loop length up to 1 KM as per NFPA 72 approval. The Panel shall be able to give pin point location of addressable units via the address code for each unit. The Panel shall also be able to automatically switch off all control switches when-ever any Alarm is triggered. . The panel shall have 230 + 5 % volts power supply, Automatic battery charger 24V, sealed lead acid maintanence free battries sufficient for 24 hours normal working and then be capable of operating the system for 30 minutes during emergency condtion. Loop interface cards, communication module, LCD/LED unit to indicate Fire / Fault Signal of individual unit, inbuilt networking port(both RS485&Ethernet),Serial port for printer,two supervisory inputs,two position key switch and USB port for programming.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . And Also Following the guideline of Fire Safty Audit Report Issue By CE PWD Jodhpur 1 - Loop Panel Add Extra for per Loop expansion beyond Two Loop SITC of UL 10th edition / EN54 / VDS certified Active Repeater Panel for Fire Alarm System with inbuilt networking port (both RS485 & Ethernet),Serial port for printer,two supervisory inputs,two position key switch and USB port for programming. The Repeater Panel shall allow users to acknowledge, reset,silence, program, view hisory events.etc (All functions similar to main panel)The user interface of the repeater panel shall be same as the Main Controller with menu driven user interface with smart search.including the cost of all accessories Etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . And Also Following the guideline of Fire Safty Audit Report Issue By CE PWD Jodhpur

Key Value

Document Fees
INR 590 /-
EMD
INR 86300.0 /-
Tender Value
INR 43.15 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents-1 0 KB
Click here to download tender document Tender Documents-1 0 KB
Click here to download tender document Tender Documents-1 0 KB
Click here to download tender document Tender Documents-1 0 KB
Click here to download tender document Tender Documents-1 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail