| 1 | Demolition of concrete block masonry built in cement mortar or cement lime mortar complete all as specified and directed. |
| 2 | M&L for Pre-cast cement concrete block masonry Type C1 1:3:6 (using 20mm graded aggregate) with solid blocks, exc.10cm in width and setting in cement mortar (1:6), complete all as specified and directed. |
| 3 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth in soft/loose soil; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed. |
| 4 | M & L for plain cement concrete 1:4:8, Type D-2 (using 40mm graded aggregates) asin foundations, filling and mass concreteetc complete all as specified & as directed. |
| 5 | Demolition of cement concrete of any description and in any position not otherwise specially provided for as in surface channel complete all as specified and directed. |
| 6 | Dismantling of Chainlink wire fencing of any description and in any position complete all as specified and directed. |
| 7 | Dismantling posts or struts (wood, steel or RCC)any section incl taking out embedded portion and making good disturbed ground complete all as specified and directed. |
| 8 | Excavation in post hole for similar holes each n exc 0.50 Cum getting out returning filling in and ramming earth around in layers nexc 25 cm watering and removed surplus soil to a distance nexc 50m and making good surface in soft/loose soil complete all as specified and directed. |
| 9 | M &L for cement concretetype B2 1:2:4 (using 40 mm graded stone aggregate) as in foundations filling for post holes and mass concrete complete all as specified and directed. |
| 10 | S & F of Framed works for chain links angles, frame work for watertanks includingetc conforming to Fe-290.Gde-E-165 complete all as specified and directed. |
| 11 | S & F Hand rails, half round or other steel section or core for wooden hand-rail straight portion,drilled and countersunk forbalusters running bars, for doors, balusters, nosing to steps including embeding in concreteand screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire meshetc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 12 | Taking down cement plaster on brick or stone wall including racking out joints, hacking for key scrubbing down with water etc complete all as specified & directed. |
| 13 | M & L for rendering 10 mm thick in CM (1:4) on brick work or concrete surfaces mixed with water proofing compound incl chajja, facia etc, finished the surfaces even and smooth without using extra cement mixed with water proofing compound complete all as specified and directed.( WPC measured separately) |
| 14 | M&L for applying two coats of cement base painton new plastered surfaces of wall over and including a coat of primer complete all as specified and as directed. |
| 15 | Supply only integral water proofing compound conforming to IS: 2645 - 1975 specification complete all as specified and as directed. |
| 16 | M & L for PCC 1:2:4 type B-0 (using 20mm graded crushed stone agg) as in coping, benching, holdfast, fixing of fencing post above walletc,finished even and smoothusing extra cementincl necessary form work complete all as specified and directed. |
| 17 | M & L for providing precast cement concrete louvres and jallies, 25mm thick (measured solid) type B0 1:2:4 (using 12.5mm garded aggregate) set in cement mortar 1:4, including all mouldings and demolition of old louvers and jallies complete all as specified and directed. |
| 18 | Supply only chain link mild steel galvanized fencing of mesh size 75 x 75 mm & nominal dia of mesh wire not less than 3 mm complete all as specified and directed. |
| 19 | Fixing only chain link fencing including line wires, any mesh size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed. |
| 20 | Restraining & re securing of mild steel barbedwire any typeincluding making good staples complete all as specified and directed. |
| 21 | S & F galvanised two strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts incl securing or laying at crossing with and provision of mild steel wire staples or steel pins complete all as specified and directed. |
| 22 | S & F of mild steel screw bolt (machine made with hexagonal or square head at one end and screwed the other or screwed both ends each screw and to be fitted with washer and one hexagonal or square nut lengthof bolt n exc 5cm and dia of shank 5 to 10 cm complete all as specified and directed. |
| 23 | S & F 10 mm dia & overmild steel round or square bars fixed behind chain link fencing as straining bars etc and similar articles complete all as specified and directed. |
| 24 | M & L for preparation of new steel surfaces exc 10cm width or girth and apply one coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified and directed. |
| 25 | M & L for preparation of new steel surfaces n exc 10cm width or girth and apply one coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified and directed. |
| 26 | M&L for manufacturing of ornamental and decorative type steel gate with structural steel conforming to Fe 410-o or 310-O all as specified, revolving on bearing plate including pintal hinges fixed on pillar in PCC blocks of size as required as site , including all locking arrangement, all as per sample approved by the Engr-in-Charge and directed and fixed in position.Note :-1.Steel gate shall be manufactured as per sample approved by the Engr-in-Charge . Photographs for the samples shall have to be collected by the contractor from the manufacturer of the gates in the area for approval of the Engr-in-charge. The cost of the same shall be deemed to be inclusive in unit rateaccordingly. |
| 27 | Dismantiling of stone slabs and tiles (Kota/ Granite stone etc.)of any discription or any thickness in floors, aprons, skirting, dado etc.laid bedded and pointed in any mortar complete all as specified and directed. |
| 28 | M&L Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing laid over 20mm thick screed layer in cement mortar 1:6 and pointed in white cement with pigment to match with colour of tile complete all as specified and directed. |
| 29 | M&L Granite (of any type) tiles 20mm thick machine cut, in skirting/dado laid over cement screed and jointed with grey cement slurry, and pointed with whitecement with admixture of pigment to match the shade of granite stone including grinding and polishing complete laid over 10mm thick screed layer in cement mortar 1:4 complete all as specified and directed. |
| 30 | M&L for providing precast cement concrete type B1 1:2:4 (using 20 mm graded aggregate) in apex stone/kerb stone with plain fair faces including chamfers, weathering throating etc and set in CM 1:4 complete with joints, size and shape as approved complete all as specified and directed. |
| 31 | M & L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) for filling of gap between road, kerbs stone and interlocking paver block with finished fair complete all as speificed and directed. |
| 32 | M & L for preparation of new concrete surfaces of any description over10 cm width or girth and applying two coats of synthetic enamel paint over and including a coat of primer complete all as specified and directed. |
| 33 | M & L for preparation of old painted concrete surfaces of any description over10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed. |
| 34 | M&L for exterior grade, coloured, cement concrete designer chequered tiles of size 30cm x 30cm x 25mm thick set, jointed and pointed in neat cement slurry with grey cement and pigment to match the shade / colour / matrix of tiles as in floor etc complete all as specified and directed. |
| 35 | M&L for screed bed or bedding layer of mortar 20mm thick in CM 1:6for laying floor finishes complete all as specified and directed. |
| 36 | M&L providing precast cement concrete rubber moulded coloured interlocking tiles with grey cement and pigment conforming to IS-15658-2006 of 80 mm thick (M-40 grade) of approved design and pattern complete all as specified and directed. |
| 37 | M & L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in as in sub base complete all as specified and directed. |
| 38 | M & L for 60 mm thick paver blocks rubber moulded PCC M-35 with grey cement and pigment conforming to IS-15658-2006 of approved design and pattern complete all as specified and directed. |
| 39 | M & L for Sand filling under floors or in foundation incl watering and consolidation for laying interlocking tiles complete all as specified and directed. |
| 40 | M & L for cutting of Bitumenous road edges to achieve straight/vertical edges to accommodate paver blocks/PCC subbase/sand Cushining etc complete all as specified and directed. |
| 41 | M & L for 100 mm thick PCC 1:2:4 type B2, (using 40 mm graded stone aggregate) as in floors/pavingfinish even and smoothwithout using extra cement complete all as specified and directed. |
| 42 | Dismantling wrought iron or mild steel work of any description not otherwise provided forcomplete all as specified and as directed. |
| 43 | Supply & fix rolled mildsteelin joist, angle ,channelas in purlins, rafters cleats etc conforming to Fe-410- W (Gde-E-250)quality A complete all as specified and directed. |
| 44 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws complete all as specified and as directed. |
| 45 | S&F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge / roof covering/ cladding to wall, fixed with self tapping screws completeall as specified and as directed. |
| 46 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends complete all as specified and directed. |
| 47 | S&F Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and as directed. |
| 48 | NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor. |