| 1 | Dewatering of following including disludging of sluldge at bottom in foul condition including taking out other dirty & filthy materials from manhole & septic tanks by sewage pump or manually using buckets/baskets, lifting the same upto 4.50M depth of tank/MH and removing to out side MD land including cleaning/clearing for following :- |
| 2 | Manhole of any dimension upto 1.5 Mtr deep |
| 3 | Manhole of any dimensionexc 1.5 Mtr but n exc 3 Mtr deep. |
| 4 | Septic Tank up to 10 User capacity. |
| 5 | Septic Tank up to 50 User capacity. |
| 6 | Septic Tankexc 50 and n exc100 users capacity. |
| 7 | Septic Tank exc 100 and n exc200 Users capacity. |
| 8 | Cleaning of SWG/RCC Sewage line of 75 to 200mm bore dia of pipe of foul condition by rodding the drain/sewage line using flexible rod/suitable device or by any other means for removing blockage from sewar line, mud, silt and any other debries obtained from sewage line with water to remove blockage and cleaning the entire rubbish, sludge etc and burrying the material obtained from sewage line including all precautionery and safety measures etc complete all as specified and directed. |
| 9 | Removing blockage from water closet, floor or gully or Nahani Trap traps and bends by rodding thoroughly and pouring water under pressure and Cleaning, clearing the drainage to efficient and Smooth flow of sludge/waste water all as specified and directed by Engineer-in-Charge. |
| 10 | NOTE FOR SL NO. 1(a)to(f), 2 &3 :-(i) Contractor\"s supervisor will report on all working days along with Two safai wala and Printed contractor\"s firm name complaint slip book at 0830 hrs at B/R Haig Line to receive complaints for blockage and to submit completion report on the same day by 1700 hrs.(ii) Printed complaint slip book area wise as per format approved by Engineer-in-Charge shall be provided and maintained by contractor.(iii) Rate quoted above shall be deemed to incl the cost of T&P, equipment, safety device etc alongwith sufficient labour to full fill the requirement to the entire satisfaction of Engineer-in-charge.(iv) if there is any major blockage in sewer line/septic tank for which additional Safaiwalas and special T&P is required same shall be provided by contractor without any extra cost to Govt. therefore contractor is adviced to visit the site before quoting the rates in tender.(v) In the event he fails to attend the complaint recovery @ Rs. 1000 per day shall be effected from the amount due to the contractor. |
| 11 | Cutting out of shrubs, kerbs and small plants of stem girth n.exc 30CM measured 1M above average ground level including cutting of grass & removing the unserviciable material like branches, leaves, grass & garbage to clear the alignment of existing sewage/drainage line to make site workable condition & making good the disturbed ground complete all as directed. |
| 12 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft soil complete all as specified and directed. |
| 13 | All as per Sl item No. 5 above but exc 1.5m depth and n exc 3.0m depth and getting out hard/dense soil complete all as specified and directed. |
| 14 | Returning, filling in soft/loose/hard/dense soil including spreading, levelling, watering & well ramming in layers n.exc 25cm complete all as specified and directed. |
| 15 | Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick spread, levelled and rammed including watering |
| 16 | Removing excavated material (surplus soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-charge. |
| 17 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, Dia of pipe 150mm bore complete all as specified and as directed. |
| 18 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, Dia of pipe 100mm bore complete all as specified and as directed. |
| 19 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, Dia of pipe 300mm bore pipe complete all as specified and as directed. |
| 20 | M&L for 150mm Inner dia DWCPE (SN8) as per IS -16098 (part-III) drain pipes laid in trenches on moorum bed including jointing and testing complete all asspecified and directed by Engineer-in-charge.Note : Moorum shall be measured separately |
| 21 | M&L for 100mm Inner dia DWCPE (SN8) as per IS -16098 (part-III) drain pipes laid in trenches on moorum bed including jointing and testing complete all asspecified and directed by Engineer-in-charge. |
| 22 | M&L for 300mm Inner dia DWCPE (SN8) as per IS -16098 (part-III) drain pipes laid in trenches on moorum bed including jointing and testing complete all asspecified and directed by Engineer-in-charge. |
| 23 | M&L for 150mm bore Reinforced concrete pipes single socketed, class NP-2, laid and jointed, complete all as specified and as directed. |
| 24 | M&L for cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in concrete bed to drain pipes including packing under & haunching against the sides of pipes after they are laid & tested for 150mm & bore pipe, complete all as specified and as directed. |
| 25 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed. |
| 26 | M&L for cement concrete Type 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundations, haunching and packing of pipe complete all as specified and as directed. |
| 27 | M&L for cement concrete Type B1 1:2:4 (20 mm graded aggregate) as in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs/benching and the like including weathering, slightly rounded for chamfered angles and throating including demolition of cement concrete (unreinforced) is ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 28 | Demolition of brick work or stone / boulder masonry built in cement mortar including all quoins, arches, pillars etc. |
| 29 | M&L for Autoclaved aerated concrete (AAC blocks (light weight) for masonry fixed with ready mixed jointing mortar complete all as specified and as directed. Make/Brand of ready mixed jointing mortar: Shall be \"Speed Dry Mix\"/\"DUBOUND\"/MAGIC BOND\"/\"BUILDWELL\". Make/Brand of ACC block : \"AEROCON\"/Ecolite ISI marked Grade-I as approved by GE. |
| 30 | M&L for Brickwork with fly ash old size bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and as directed. |
| 31 | M&L except brick work with sub class \"B\" brick straight or curved on plan exc 6m mean radius with old size bricks in CM 1:6 complete all as specified and directed. |
| 32 | Taking down cement plaster any description on brick or stone walls etc including racking out joints hacking for key scrubbing down with water etc complete all as specified and as directed. |
| 33 | M&L for Rendering15mm thick with Ready Mix Plaster of Make- ACC’s “ACCOPLAST” / CK Birla’s “AEROCON” / Speed Dry Mix’s “ECO PLASTER” / “MAGIC PLAST” / “BUILDWELL on brick work or concrete surfaces etc finished surfaces even and smooth complete all as specifed and directed. |
| 34 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for Note- Rate includes for reinforcement cutting as required to facilitate demolition. |
| 35 | M&LPre-cast reinforced cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate in manhole cover/slabs and placing in position including necessary form work in CM 1:6 complete all as specified and directed. |
| 36 | S&F for mild steel TMT bars 8mm to 10mm dia cut to length, bent to shape required including cranking, bending, spirally for hooping columns, hooking ends & binding with & including MS wire (annealed) not less than 0.9mm dia of or securing with clips complete all as specified and as directed. |
| 37 | Dismantling of PVC Pipes with fittings upto 75mm to 110mm dia complete all as specified and as directed. |
| 38 | S&F for PVC (SWR) pipe110 mm dia single socketed in any length with rubber ring jointed levelfixed to walls complete all as specified and as directed. |
| 39 | All as per Item No. 30 above but except pipe. |
| 40 | S&F for PVC (SWR) pipe75 mm dia single socketed in any length with rubber ring jointed levelfixed to walls complete all as specified and as directed. |
| 41 | All as per Item No. 32 above but except pipe. |
| 42 | S&F for PVC (SWR) bends with access door 110 mm dia complete all as specified and as directed. |
| 43 | S&F for PVC (SWR) bends with access door 75 mm dia complete all as specified and as directed. |
| 44 | S&F PVC (SWR) plain bend 110 mm dia complete all as specified and as directed. |
| 45 | S&F PVC (SWR) plain bend 75 mm dia complete all as specified and as directed. |
| 46 | S&F PVC (SWR) branch piece singleor double \"Y\" equal or unequal with access door 110 mm dia complete all as specified and as directed. |
| 47 | S&F PVC (SWR) branch piece singleor double \"Y\" equal or unequal with access door 75 mm dia complete all as specified and as directed. |
| 48 | S&F PVC (SWR) vent cowl 110 mm dia complete all as specified and as directed. |
| 49 | S&F PVC (SWR) vent cowl 75 mm dia complete all as specified and as directed. |
| 50 | S&F in repairs 75mm bore PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 51 | S&F in rep vitreous china squatting Pan “Orissa” Pattern, of size 580mm x 440mm white with integral foot rests and trap (excluding flushing cistern and flush pipe) including provn of cement concrete bedding complete asfixed complete all as specified. |
| 52 | S&F in rep vitreous china wash down water closet pan (pedestal pattern), white including connection to drain (or outgoing pipe) and to flushing pipe with and including plastic water closet seat, white closed pattern with flat bottom, cover and mild steel hinges device complete all as specified. |
| 53 | M&L fornon skidCeramic dark coloured tiles 6-7mm thick (squar/ ractangular) area of each tiles exc 0.06 Sqm but not exc o.11Sqm, in floor including 15mm thick screed bedding in CM (1:6) and jointing with neat cement slurry and pointing with white/coloured cement to match the surfaces including demolition of stone slabs and tiles laid, bedded and pointed in any mortar of any description or thickness in floors, aprons etc.complete all as specified and directed. |
| 54 | Cutting into road/ black top/PCC pavement of any thickness including excavation in any type of soil upto 0.50m to 0.80m width and 0.50m to 1.50m depth, refiling, compaction of soil after laying of PCC bed, haunching and pipe, packing and compaction with existing soling/GSB/WBM/WMM, and top surface prepared with 0.15m thick cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) complete all as specified and as directed. |
| 55 | Cutting into existing manholes for removing existing branch drain, making good to pipe and rendering cutting out branch channel, and making good benchings complete all as specified and as directed. |
| 56 | Demolition of stone slabs and tiles laid, bedded and pointed in any mortar of any description or thickness in floors, aprons, walls etc complete all as specified and as as directed. |
| 57 | M&L for precast cement concrete interlocking tiles 60 mm thick Rouber moulded, prepolished with strength 35 N/sqmm as in floor/pavement laid on 30 mm thick stone dust cushioning laid dry to the profile complete all as specified and as directed. |
| 58 | M&L for chequered cement concrete tiles 30cmx30cmx25mm thick Rubber moulded with grey cementandpigment, over and including 15mm thick screed in CM (1:6), set jointed & pointed in neat cement slurry in floors complete all as specified and as directed. |
| 59 | Taking up or down 15mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and as directed. |
| 60 | Taking up or down 20mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and as directed. |
| 61 | Taking up or down 25mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and as directed. |
| 62 | S&F 15mm boreTubes, `medium grade\" galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed. |
| 63 | S&F 20mm boreTubes, `medium grade\" galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed. |
| 64 | S&F 25mm boreTubes, `medium grade\" galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed. |
| 65 | M&L for cement concrete (1:4:8) type D2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and as directed. |
| 66 | M&L for Glazed ceramic tilesof size300 mm x 450 mm x 7mm thick (coloured) of superior qualityfixed on vertical surfaces such asskirting/dado etc, set and jointed in neat cement slurry over 10mm thick backing coat in CM (1:4)and pointed in coloured cement to match the colour of tile complete all as specified and directed. |
| 67 | Note: Amount of sch of credit of Rs.78,800/-will be deducted from total amount of BOQ. |