supply of Biochemistry Lab Items , Reagents/Kits/ Chemical/Glassware/ Polyware Etc Items , Albumin (Liquid) , End Point, Linearity =8Gm/L , Alk. Phos. (Liq.) ,Kinetic, Linearity = 1200U/L , Alt (Gpt) (Liq) ,Kinetic,Linearity =600U/L , Amylase (Liq) ,Kinetic, Linearity = 1500U/L , Ast (Got) (Liq), Kinetic, Linearity = 600U/L , Bilirubin (Direct) (Liq) ,Fixed Time, Linearity = 8Mg/Dl , Bilirubin (Total) , Fixed Time, Linearity =25Mg/Dl , Calcium (Liq.) , End Point, Linearity =15Mg/Dl , Cholesterol (Liq.), End Point, Linearity =1000Mg/Dl , Serum Ck-Mb Kit With Calibrator And Control (Liquid Stable Or Lyophilised Reagent Reconstitution Stability 30 Days At 2-8°C Immunoinhibition Uv Kinetic Method), Linearity = 2000 U/L With Lyophilised Calibrator And Control Having Reconstitution Stability = 7 Days At 2-8°C. , Ck-Nac ,Kinetic,Linearity =2000U/L , Creatinine (Liq) ,Kinetic, Linearity =25Mg/Dl , Gamma-Gt (Liquid) ,Kinetic, Linearity = 1000U/L , Glucose (Liq.) , Kinetic, Linearity =600Mg/Dl , Hb A1c/Hb (Liquid), With Calibrator, End Point, Linearity =7-23G/Dl , Hdl Cholesterol (Liquid) Direct Clearance Method, Kinetic, Linearity =150Mg/Dl , Ld Pyruvate - > Lactate (Liquid),Kinetic, Linearity = 1100U/L , Lipase ,Kinetic, Linearity = 600U/L , Phosphorus (Inorganic) (Liq.) End Point, Linearity =20Mg/Dl , Total Protein (Liquid) (Mono Reagent), End Point, Linearity = 12Gm/Dl , Triglycerides (Liquid), End Point, Linearity = 1000Mg/Dl , Urea (Liq.) ,Kinetic, Linearity = 300Mg/Dl , Uric Acid (Liq), End Point, Linearity = 20Mg/Dl , Csf Microprotein (Liquid Stable, Ready To Use) Linearity=400Mg/Dl.(For Fully Automatic Clinical Chemistry Analyser) , Magnesium, End Point, Ready To Use, Liquid Stable, Linearity=50Mg/Dl , Serum Ada , Multi Calibrator For Fully Auto Analyser(For Calibration Of Allbiochemical Parameters Except Hba1c , Hdl, Ckmb. Calibrator Should Be Tracable To Internationally Accepted Norms. Calibrator Will Run As Per Requirement Time To Time) , Multi Control(Low/High /Normal) For Fully Auto Analyser(For Control Of Allbiochemical Parameters Except Hba1c , Hdl, Ckmb). Above Biochemical Parameter Should Be Traceable For Internationally Accepted Norms. , External Quality Control , Hb A1c Control Level 1 And Level 2 , Hdl/Ldl- Cholesterol Calib , Lipid Control Level 1 , Lipid Control Level 2 , Serum Ironwith Calibrator & Control And Tibc ( Total Iron Binding Capacity ) , Total Acid Phosphatase , G6pd With Control , Transferrin With Calibrator ( Serum Protein Multi .Cal) & Control (Ita Sera) , Ferritin Withcalibrator & Control , Ammonia Withcalibrator & Control , Ise Low/ High Urine Standard , Myoglobin , Urine Calibrator , Urine/Csf Albumin Calibrator , U&Csftotal Proteins Red Prrogallolcolour 150 Ml. , Crp Latex, R1 4 X 30 Ml, R2 4 X 30 Ml , D-Dimer, R1 2 X 12.5 Ml, R2 2 X 12.5 Ml , Crp Latex Calibrator Normal Set (Level 1-5) 1X2 Ml , Crp Latex Calibrator Highly Sensitive Set (Level 1-5) 1X2 Ml , D-Dimer Calibrator (Level 1) 2X2.5 Ml, (Level 2) 2X0.5 Ml , Crp Latex Control Serum (Level 1-2) 2X3 Ml , D-Dimer Control (Level 1 - 2) 2 X 0.5 Ml , Starter Kits (1+2) , Wash Buffer , Reaction Modules , Light Check , Il-6 , Pct , Ferritin , D Dimer , Crp , Nt-Probnp , Vitamin B12 , Vitamin D3 , Folic Acid (Fa) , Myoglobin , Troponin I (Ctni) , Thyroglobulin , Pm Kit , Ise Electrode (Cl) Linearity =191 Mmol/L. , Ise Electrode (K) , Ise Electrode (Na) Linearity =37 &187Mmol/L , Wash Solution, 4X5l(Must For 5800 And Dxc700 Au) , Cleaning Solution6x450ml , Photometer Lamp, 12 V, 20 Wt(1Each)-(Must For 480 And Dxc 700) , Sample Cup, 2.5Ml(Pkg Of 1000) , Mixing Bar (Spiral) Au5800 , Mixing Bar (L-Shaped) Au5800 , Sample Probe(1 Each) , Reagent Probe (1 Each) , S-Syringe(1 Each) , R-Syringe(1 Each) , Pinch Valve Tubing(Pkg Of 2) , Mixing Bar (Spiral) Au480/Dxc 700 Au , Mixing Bar (L-Shaped) Au480/Dxc 700 Au , Lithium Electrode , Hitachi Sample Cup, Polystyrene, Highly Transparent, Non-Sticky, 17Mm X 38Mm Or 2Ml , White Paper Laboratory Tissue Roll(For Cleaning Of Equipments, Pattern Plain And Should Be Thick And Not Leave The Rashes Or Fibers On Cleaning Surfaces) , Tray With Divided 2-4 Compartments(Perfect For Hold And Transport Of Racks With Samples) , Marker Pen With Fine Tip (Red/Black, Usable On Glassware) , Antiseptic Soap For Hand Wash (Liquid) , Hand Sanitizer (Liquid), Concentration Of Contents According To Who Guidelines , Sodium Hypochlorite Solution (5-10%) , Acid Wash Solution (Should Be Compatible Withimola I & Ii) , C1wash Solution 2.5L. (Should Be Compatible Withimola I & Ii) , Cleaning Solution (Contamination Avoidance) (For Beckmann Coulterau 680) , Cleaning Solution Weekly Wash (Forbeckmann Coulter Au 680) , Ise Buffer (For Au680) , Ise Calibator Afolig Bag ( For Imola) , Ise Calibrant B ( For Imola) , Ise Electrode (Ref)(Forbeckmann Coulter Au680) , Ise Internal Ref (For Beckmann Coulterau680) , Ise Mid Std (Forbeckmann Coulter Au680) , Ise Ref (Forbeckmann Coulter Au680) , Ise Selectivity Check (Forbeckmann Coulter Au680) , Ise Serum Std High (Forbeckmann Coulter Au680) , Ise Serum Std Low (For Beckmann Coulterau680) , Wash Solution (For Au680) , Pm Kit For Imola Rx Imola , Ise Wash Solution( For Randox Imola) , Wash Solution No. 1 (Fully Autoanalyzer Imola/Modena) , Wash Solution No. 2 (Fully Auto Analyzer Imola/Modena) , Wash Solution No. 3 (Fully Auto Analyzer Imola/Modena) , 20 Bag Filter Element , 10 Cartidge Filter , 10 Carbon Filter , 10 D.I.Cartridge , 1812 Ro Membrane , Booster Pump , Pressure Gauge , Solenold Valve , Flow Restrictor , 7 Ltr.Resin Recharge , Inlet Valve , Peristalitic Pump Head (Cal A) , Peltier Tile , Halogen Lamp , Spt Nozzle , Saline Diluent , Sodium Electrode , Potassium Electrode , Chloride Electrode , Reference Electrode , Alkaline Wash Solution , Acid Wash Solution , Ise Detergent , Ise L Solution , Ise Buffer , Serum Low/ High Calibrators , Precision Check Kit , C1 Solution Wedge , Tube Set For Ise , Tube Set , Na Electrode (Beckman Coulter Au680) , K Electrode(Beckman Coulter Au680) , Clelectode(Beckman Coulter Au680) , Ref Electrode(Beckman Coulter Au680 , S Tube , R Tube , Peristalitic Pump Tube , Light Source Lamp , S Probe , R Probe , 1 Year Pm Kit , 2 Year Pm Kit , Peltier Assembly , Dp Pinch Valve Tube Assembly (For Au680) , Internal Filling Solution For Ckk Lyte , Cleaning Solution Pack Ckk Lyte , K Electrode For Ckk Lyte , Na- Electrode For Ckk Lyte , Ref -Electrode For Ckk Lyte , Trouble Shooting Kit For Ckk Lyte , Ckky- Lyte Universal Reagent Pack , Cl- Electrode For Ckk Lyte , Internal Filling Solution For Ckk Lyte , Microcentrifuge Tubes With Attached Hinged Cap (1.5 Ml) , Microcentrifuge Tube (1.5 Ml) , Micropipette 10 ?L Fixed Volume , Micropipette 50?Lfixed Volume , Micropipette Fixed Volume 100 ?L , Micropipette Fixed Volume 1000 ?L , Micropipette Fixed Volume 500 ?L , Micropipette Variable Volume Range 100-1000 ?L , Micropipette Variable Volume Range 10-100 ?L , Micropipette Variable Volume Range 200-1000 ?L , Micropipette Variable Volume Range 20-200 ?L , Micropipette Variable Volume Range 5-50 ?L , Poly Propylene Micro Litre Tips (Upto 200 ?L) Yellow Tips. , Poly Propylene Micro Litre Tips (Upto 200 ?L-1000 ?L) Blue Tips , Test Tube Stand (48 Holes) Plastic , Test Tube Stand (96 Holes) Plastic , Torniquete , Vacutainers Sodium Citrate Vial , K3-Edta Tubes Evacuated Blood Collection (Plastic) Tube With Spray Dried K2 Edta/K3 Edta With Lavender Safety Cap. It Should Be Made Of Clear Latex Free Polyethylene Terepthalate. 13Mm×75Mm With 3.0Ml Volume.Batch Wise Sterility, Pyrogenicity And Toxicity Certificate Should Be Given. Gamma Sterilize With Certificate Proof Of Pervious Training Record. Firm Should Provide Training To Technicians/Nurses Regularly. (1×100). , Blood Sample Vial With Screw Cap 17X45 Mm , Glass Test Tube(75X12mm) , Plane Vial With Clot Activation 4 Ml , Access Sample Cups ( 2 Ml) , D-10 Dual Recorder Pack , Lyphocheck Diabetes Control