| 1 | Cleaning of sewage line, horizontal or vertical of dia 75 mm to 150mm by rodding, well flushing using adequate/ sufficient water and making it clear for smooth flow sewage from WC/ NT/ SNT/ FT (at any floor to 1st manhole outside building) including desludging the 1st manhole and cleaning to entire satisfaction of Engineer-in-Charge and removing the sludge to a distance outside of MOD land from site; resetting the manhole cover and making the area neat and clean complete all as specified and as directed.Note: - For the purpose of payment, cleaning of sewage lines and upto including 1st manhole shall be measured as one job. |
| 2 | Cleaning of existing drain pipes upto and including 200mm dia at any depth by rodding manually/ mechanically as required at site from manhole and well finishing after cleaning including getting out sludge if any and liquid materials from connecting manholes deposited the sludge to any distance place outside the defence land at their own cost and cost of removal shall be included in the quoted rates complete all as specified and as directed by Engineer-in-Charge in case requirement of injecting machine is necessary will also be provided by the contractor as directed by Engineer-in-Charge. |
| 3 | Cleaning of Septic tanks of capacity upto and including 25 users to 500 Users by removing sludge and sludge water by pumping or manually or by any means and the sludge/ sludge water is to be disposed off in covered containers to a distance exceeding 2 Kms outside the peripherry of defence land including taking off and refixing manhole covers complete all as specified and as directed. |
| 4 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth, for foundation etc. and getting out in any type of soil complete all as specified and as directed. |
| 5 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed. |
| 6 | Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. |
| 7 | Demolition and breaking up drain pipes (salt glazed stoneware, AC or reinforced concrete) of 150 mm dia, jointed in cement mortar and taking out from trenches and removing debris including concrete bed and haunching from the side outside cantt area complete all as specified and as directed. |
| 8 | Material and labour 150 mm bore/ inner dia double wall corrugated HDPE Pipes (SN-4) with integral socket and necessary fittings, laid in trenches jointed complete all as specified and as directed. |
| 9 | Demolition and breaking up drain pipes (salt glazed stoneware, AC or Reinforced concrete) of 200 mm dia, jointed in cement mortar and taking out from trenches and removing debris including concrete bed and haunching from the side outside cantt area complete all as specified and as directed. |
| 10 | Material and labour 200 mm bore/ inner dia double wall corrugated HDPE Pipes (SN-4) with integral socket and necessary fittings, laid in trenches jointed complete all as specified and as directed. |
| 11 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for cement concrete complete all as specified and as directed. |
| 12 | Material and labour providing pre-cast cement concrete (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in cover slab of manholes, septic tank, soak well etc set in cement mortar (1:4) with plain fair faces including chamfered weathering, throating etc including necessary use and waste of form work complete all as specified and as directed. |
| 13 | Supply and fixing precast cement concrete louvers and jallies, 45mm thick (measured solid), including all moulding and set in cement mortar (1:4) complete all as specified and as directed. |
| 14 | Supply and fixing mild steel TMT bars 6 to 8 mm dia as in reinforcement, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed. |
| 15 | Supply and fixing in repair Vitreous china wash down water closet pan with flushing cistern (one piece) including fixing bolts, soft closer seat cover and flush pipe with \"P\" trap connecting pipe complete all as specified and as directed.Make: - Cera Cat Part No : S1013230 or equivalent in makes as specified in Group - 1 of Appx \"F\". |
| 16 | Supply and fixing in repairs Vitreous china wash down water closet (Pedestal Pattern) \"P\" or \"S\" trap (excluding flushing cistern and flush pipe) including PVC seat cover white closed pattern with recessed bottom and connection to drain or outgoing pipe and flushing pipe complete all as specified and as directed. |
| 17 | Supply and fixing in repair Vitreous china squatting pan \"Orrisa\" pattern size 580 x 440 mm white with integral foot rest, \"P\" or \"S\" trap and lime concrete bedding complete making good disturbed ground complete all as specified and as directed. |
| 18 | Supply and fixing in repairs 10 litres capacity PVC low level flushing cistern including 32mm dia PVC flush pipe, fixing in position with PVC connection pipe of 15mm x 450mm long etc complete all as specified and as directed. |
| 19 | Supply and fixing in repair Vitreous china urinal, half stall type, white (minimum), with including 32mm bore PTMT waste coupling and PVC connection pipe of 15mm x 450mm long and PVC waste pipe 32mm bore complete all as specified and as directed. |
| 20 | Supply and fixing in repairs Vitreous china bowl urinal flat back, with grating and union for discharge pipe including 32mm bore PTMT waste coupling, PVC connection pipe of 15mm x 450mm long and 32mm PVC waste pipe complete all as specified and as directed. |
| 21 | Supply and fixing in repairs Vitreous china wash hand basin, oval shape counter top, any coloured including 32mm bore PTMT waste coupling, PVC connection pipe of 15mm x 450mm long and 32mm PVC waste pipe complete all as specified and as directed.Make: - Cera Cat Part No : S2030102 or equivalent in makes as specified in Group - 1 of Appx \"F\". |
| 22 | Supply and fixing in repairs Vitreous china Wall hang wash hand basins including 32mm bore PTMT waste coupling, waste pipe and PVC connection pipe of 15mm x 450mm long complete all as specified and as directed.Make: - Cera Cat Part No : S2040121 or equivalent in makes as specified in Group - 1 of Appx \"F\". |
| 23 | Supply and fixing in repair Vitreous china Pedestal for Wash Hand Basins complete all as specified and as directed. |
| 24 | Supply and fixing in repair PVC connection 15 mm dia 450 long with PTMT nut at both ends complete all as specified and as directed. |
| 25 | Supply and fixing in repairs 15mm dia PVC connection with brass check nut of length 600mm complete all as specified and as directed. |
| 26 | Supply and fixing in repairs 32 mm dia bore PVC flexible pipe for wash hand basin complete all as specified and as directed. |
| 27 | Supply and fixing in repair PVC (SWR) pipes single socketed in any length with solvent cement joints, fixed to wall/ floor/ trenches for the following bore of pipe: - |
| 28 | 110 mm dia bore. |
| 29 | 75mm dia bore |
| 30 | Supply and fixing in repair PVC (SWR) bends any radius with solvent cement joints, fixed to for the following bore of pipes: - |
| 31 | 110 mm dia bore. |
| 32 | 75mm dia bore |
| 33 | Supply and fixing in repair PVC (SWR) junction single, single (T) equal or unequal with solvent cement joints, fixed to for the following bore of pipes: - |
| 34 | 110 mm dia bore. |
| 35 | 75mm dia bore |
| 36 | Supply and fixing in repair cover of CI oval access door with bolts and rubber gasket to make it water tight for 100 mm bore CI bends complete all as specified and as directed by Engineer-in-Charge. |
| 37 | Supply and fixing in repair cover of CI oval access door with bolts and rubber gasket to make it water tight for 75 mm bore CI bends complete all as specified and as directed by Engineer-in-Charge. |
| 38 | Dismantling CI/ PVC pipe 75/ 100mm bore complete all as specified and as directed by Engineer-in-Charge. |
| 39 | Material and labour of CI sand cast pipe 75 mm bore fixed to wall/ laid in trenches etc jointed with cement joints complete all as specified and as directed by Engineer-in-Charge. |
| 40 | Description all as per Ser item No 33.00 here-in-before but 100mm bore complete all as specified and as directed by Engineer-in-Charge. |
| 41 | Dismantling floors hearth or wall tilling including cement mortor bedding (but not backing) removing unserviceable materials outside MOD area and rubbish off the premises complete all as specified and as directed. |
| 42 | Material and labour Non-skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. fixed with approved tile adhesive and provided with 4mm spacer, spacer gaps to be filled with approved epoxy grout complete all as specified and as directed by Engineer-in-Charge. |
| 43 | Material and labour Non-skid ceramic tiles 7 to 8 mm thick (square/rectangular) in vertical surface such as skirting, dado etc. fixed with approved tile adhesive and provided with 4mm spacer, spacer gaps to be filled with approved epoxy grout complete all as specified and as directed by Engineer-in-Charge. |
| 44 | Material and labour Non-skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile not exceeding 0.18 Sqm, in floors etc. fixed with approved tile adhesive and provided with 4mm spacer, spacer gaps to be filled with approved epoxy grout complete all as specified and as directed by Engineer-in-Charge. |
| 45 | Material and labour Glazed ceramic tiles 300 x 450 x 7mm thick on vertical surface such as in skirting, dado etc. fixed with approved tile adhesive and provided with 4mm spacer, spacer gaps to be filled with approved epoxy grout complete all as specified and as directed by Engineer-in-Charge. |
| 46 | Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 47 | Material and labour PCC 75mm thick (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) in sub base complete all as specified and as directed by Engineer-in-Charge. |
| 48 | Demolition of stone slabs and tiles of any description or thickness in floors/ walls laid bedded and pointed in any mortar etc. complete all as specified and as directed. |
| 49 | Material and labour Granite (of any type) 16-20mm thick (tabled rubbed and polished) as in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in colour cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick screed bed in cement mortar (1:6) edges of slab to be rounded from all sides (including cutting, wastage and polishing) complete all as specified and as directed. |
| 50 | Supply and fixing Machine cut kota stone slab flooring 16-20mm thick over 15 mm thick cement screed bed in cement mortar (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed by Engineer-in-Charge. |
| 51 | Supply and fixing Machine cut kota stone slab 16-20mm thick over 10 mm thick as in vertical surface over rendering in cement mortar (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed by Engineer-in-Charge. |
| 52 | Material and labour Coloured chequered tiles of size 30cm x 30cm x 25mm thick set, jointed and pointed in neat cement slurry in floors with grey pigment cement and pigment etc and screed bed or bedding layer of mortar 20mm thick (1:4) for laying floor finishes complete all as specified and as directed. |
| 53 | Material and labour for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 grade with grey cement and pigment etc complete all as specified and as directed by Engineer-in-Charge. |
| 54 | Material and labour Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 55 | Material and labour PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in coping including weathering, slightly rounded or chamfered angles and including necessary form work complete all as specified and as directed. |
| 56 | Material and labour PCC (1:3:6) type C-2, 100 mm thick laid as in plinth protection/ paving etc finished even and smooth without usnig extra cement complete all as specified and as directed. |
| 57 | Taking down cement plaster on brick or stone walls etc. including racking out joints, hacking for key, scrubbing down with water, any description etc. and removing of the rubbish outside of MOD land complete all as specified and as directed. |
| 58 | Demolition of brick work or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed. |
| 59 | Material and labour brick work with sub class \"B\" bricks straight or curved on plan exceeding 6 m mean radius built in cement mortar (1:4) complete all as specified and as directed. |
| 60 | Material and labour brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exceeding 6m in mean radius, built in cement mortar (1:6) but except brick i.e. using serviceable bricks obtained from Ser item No. 53.00 here-in-before complete all as specified and as directed. |
| 61 | Material and labour 15 mm thick rendering on brick work or concrete surface in cement mortar (1:4), surface finished even and fair without using extra cement complete all as specified and as directed. |
| 62 | Material and labour two coats of cement based paint including preparation of new plastered surfaces over one coat of primer complete all as specified and as directed. |
| 63 | Supply and fixing rotational moulded polyethylene water storage tanks 2000 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part - I including dismantling of existing water tank, including 20mm ball valves, 20mm tank nipple complete all as specified and as directed by Engineer-in-Charge. |
| 64 | Supply and fixing rotational moulded polyethylene water storage tanks 1000 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part - I including dismantling of existing water tank, including 20mm ball valves, 20mm tank nipple complete all as specified and as directed by Engineer-in-Charge. |
| 65 | Supply and fixing rotational moulded polyethylene water storage tanks 500 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part - I including dismantling of existing water tank, including 20mm ball valves, 20mm tank nipple complete all as specified and as directed by Engineer-in-Charge. |
| 66 | Supply and fixing in repairs 20mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (minimum weight 210 grams) complete all as specified and as directed by Engineer-in-Charge. |
| 67 | Supply and fixing in repairs PVC water tank covers required for 500 litres to 1000 litres PVC water tanks complete all as specified and as directed. |
| 68 | Cleaning and removal of scale and dirt etc from water storage tanks exceeding 250 and not exceeding 500 litres of capacity and from mouths of circulating pipes etc. complete all as specified and as directed. |
| 69 | Cleaning and removal of scale and dirt etc from water storage tanks exceeding 500 and not exceeding 1000 litres of capacity and from mouths of circulating pipes etc. complete all as specified and as directed. |
| 70 | Cleaning and removal of scale and dirt etc from water storage tanks exceeding 1000 and not exceeding 2000 litres of capacity tanks and from mouths of circulating pipes etc. complete all as specified and as directed. |