Tender For Repair/Replacement Of Unsv Lt Ug Cables, Lt Feeder Pillar Boxes At Tech Area Of Afs Yelahanka; 1 Supply and layingin trenches, LT underground cableof size 10 Sqmm2 core XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall including taking down complete all as specified and as directed. 2 All as per item No 1 here-in-before but 16 Sqmm 4 core 3 All as per item No 1 here-in-before but25 Sqmm 3.5 core 4 All as per item No 1 here-in-before but35 Sqmm 3.5 core 5 All as per item No 1 here-in-before but70 Sqmm 3.5 core 6 All as per item No 1 here-in-before but95 Sqmm 3.5 core 7 All as per item No 1 here-in-before but120 Sqmm 3.5 core 8 All as per item No 1 here-in-before but240 Sqmm 3.5 core 9 All as per item No 1 here-in-before but300 Sqmm 3.5 core 10 M & L for boring of holes under roof, pavement, hardstanding by trenchless technologyand necessary machine including GI pipe of 50/80/100mm dia suitable for 0.4mpa working pressure complete all as specified and directed. 11 Supply and laying GI tubing light grade 50mm dia in trenches/fixing on pole /wall/crossing in drain etc. for protection of UG cable complete all as specified and directed. 12 Supply and laying GI tubing light grade 80mm dia in trenches/fixing on pole /wall/crossing in drain etc. for protection of UG cable complete all as specified and directed. 13 Supply and fix in repair 63 Amp rating, 415V, 10KA C curve miniature circuit breaker (MCB) of four pole in the MCB DB complete with connection testing and commissioning complete all as specified and directed. 14 Supply and fix in repair 32 Amps rating, 240V, 10 KA B curve miniature circuit breaker (MCB) of Single Pole and Neutral, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. 15 Supply and fix cable route indicator made out of 3 mm thick MS sheet of size 20 cm x 15 cm duly painted with two coats black paint over a coat of red oxide primer and writing cable direction, capacity, size of cable with white paint, mounted on angle iron 40x40x3 mm, angle height 45 cm, (30cm below ground level) with PCC 20cmx20cmx15cm all as specified and as directed. 16 Supply, installation and commissioning in repair LT out door loop in loop out terminal box with sloping canopy of size 600x450x250mm made out of 3 mm thick CRCA sheet duly painted with two coats of synthetic enamel paint over a coat of red oxide, front and rear hinged doors mounted on 40x40x6 mm MS angle iron frame 90 cms height erected in ground with PCC foundation 1:4;8 with 40mm stone aggregate including supply and fixing insulated aluminium bus bar of size 50x 6mm for three phase and neutral 300mm length suitable for 8 outgoingsrespectively mounted on insulators and terminating with suitable cable with glands and provision of one MCCB 63 Amps 4 pole ,415 Amps, 50 Hz of breaking capacity 16 KA as incomer with RYB Indicator,including taking down old terminal boxes complete all as specified and directed. 17 Supply, installation and commissioning in repair LT out door loop in loop out terminal box with sloping canopy of size 600x450x250mm made out of 3 mm thick CRCA sheet duly painted with two coats of synthetic enamel paint over a coat of red oxide, front and rear hinged doors mounted on 40x40x6 mm MS angle iron frame 90 cms height erected in ground with PCC foundation 1:4;8 with 40mm stone aggregate including supply and fixing insulated aluminium bus bar of size 50x 6mm for three phase and neutral 300mm length suitable for 8-10 outgoings respectively mounted on insulators and terminating with suitable cable with glands and provision of one MCCB 125 Amps 4 pole ,415 Amps, 50 Hz of breaking capacity 25 KA as incomer, RYB indicator for incoming including taking down old terminal boxes complete all as specified and directed. 18 Supply,install,testing and commissioning of LT Panel boardCPRI approved outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars duly insulated by insulation of RYB colour 600 Amps rating mounted on porcelain insulators .The panels shall be factorymade, double door, made out of 3.15 mm thick MS sheettotally enclosed dust, vermin and rust prooffront operated, front and rear opening with locking arrangement fixed with MSangle iron frame of size 50X50X5 mm duly embedded in PCC platform and duly powder coated with 7 tank process with colour as directed including internal wiring with multistranded copper conductor cable of suitable size including lugs and cable gland to incoming and outgoing cable all as directed at site and comprising of the following: INCOMING MCCB 4 pole 400 Amps 35 kA - 01 NosOUTGOING :- MCCB 4 Pole 200 Amps 25 kA - 01 Nos MCCB 4 pole 125 Amps 25 kA - 03 Nos MCCB 4 pole 63 Amps 16 kA - 01 Nos Multifunctional VAF meter, PF meter - 1 Nos RYB Neon indicating lamp -1 set of threeMS work including angle iron frame and PCC work Internal wiring including copper lugs Note: Bottom portion of the Panels should minimum 45 mm above the ground level 19 Supply,install,testing and commissioning of LT Panel boardCPRI approved outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars duly insulated by insulation of RYB colour 300 Amps rating mounted on porcelain insulators .The panels shall be factorymade, double door, made out of 3.15 mm thick MS sheettotally enclosed dust, vermin and rust prooffront operated, front and rear opening with locking arrangement fixed with MSangle iron frame of size 50X50X5 mm duly embedded in PCC platform and duly powder coated with 7 tank process with colour as directed including internal wiring with multistranded copper conductor cable of suitable sizeincllugs and cable gland to incoming and outgoing cable all as directed at site and comprising of the following: INCOMING:-MCCB 4 pole 200 Amps 25 kA - 01 NosOUTGOING:-MCCB 4 pole 100 Amps 25 kA - 03 Nos MCCB4 pole 63 Amps 16 kA - 02 Nos Multifunctional VAF meter, PF meter - 1 No RYB Neon indicating lamp -1 set for incoming MS work including angle iron frame and PCC work Internal wiring including copper lugs. 20 Supply,install,testing and commissioning of LT Panel boardCPRI approved outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars duly insulated by insulation of RYB colour 300 Amps rating mounted on porcelain insulators .The panels shall be factorymade, double door, made out of 3.15 mm thick MS sheettotally enclosed dust, vermin and rust prooffront operated, front and rear opening with locking arrangement fixed with MSangle iron frame of size 50X50X5 mm duly embedded in PCC platform and duly powder coated with 7 tank process with colour as directed including internal wiring with multistranded copper conductor cable of suitable sizeincllugs and cable gland to incoming and outgoing cable all as directed at site and comprising of the following: INCOMING :-(a) 4 Pole MCCB 200 Amp, 50 Hz, 415 V with rupturing capacity 25 KA, Incomer -1 NoOUTGOING(b) 4 Pole MCCB 160 Amp, 50 Hz, 415 V with rupturing capacity 25 KA, -01 No(c) 4 Pole MCCB 63 Amp , 50 Hz, 415Vwith rupturing capacity 16 KA - 01 Nos (c)Digital Volt meter (0-500 V)-01 No(d)Digital Ammeter-01 No(e) CTs 200/5- set of 3 No(f) LED type Indication lamps (RYB)-one set 21 Supply and fixing in replacement of 7 meter high hot dipped octagonal poles with 130mm bottom dia and 70mm top dia made up of 3mm thick HT Sheet alongwith base plate of size 200x200x12mm including foundation bolts & bracket of size M20x600mm EN 8 grade J type foundation bolts and numbering of poles, in white paint over black painted back ground at a height of 1.5m from bottom of pole with 5 cm large bold letters 2 (inch) wide withetc complete as required and complete accessories as required including dismantling existing pole complete all as specified and directed. 22 Supply and fix in repair glow signage boards withbase frame made from angleiron andbacksideformACP sheet 3mm thick with IP 68 ProtectionLED module, goodquality virgin monomerAcrylic sheet,MES Logo &Southern Command logo in letters with 5 mm sun board channel, including completewiringandpower supplywith IP 68 protection , each letter will be made with computer offset for havingsame letter style and type as approved complete all as specified and directed for following boards :- 23 (a) POWER HOUSE MAIN RECEIVING STATION (11/.440KV) MILITARY ENGINEER SERVICES GARRISON ENGINEER (AF) YELAHANKA 24 (b ) 112 HU SUB STATION (11/.440 KV)MILITARY ENGINEER SERVICES GARRISON ENGINEER (AF) YELAHANKA 25 (c) COMPLAINT CELL MILITARY ENGINEER SERVICES GARRISON ENGINEER (AF) YELAHANKA 26 (e) SUB STATION A (11/.440 KV) MILITARY ENGINEER SERVICES GARRISON ENGINEER (AF) YELAHANKA 27 (f) SUB STATION B (11.440 KV) MILITARY ENGINEER SERVICES GARRISON ENGINEER (AF) YELAHANKA 28 Supply and jointing straight through joint outdoor type 1100 volts grade heatshrinkable type suitable for 3.5x 25 sqmm to3.5x 95 sqmm LT XLPE cable and testing after jointing complete all as specified and as directed. 29 Supply and jointing straight through joint outdoor type 1100 volts grade heatshrinkable type suitable for 3.5x 120 sqmm to3.5x 240 sqmm LT XLPE cable and testing after jointing complete all as specified and as directed. 30 Supply and fix in repair CTs suitable for existing LT panel board of capacity 400 to 630 Amps all as specified and as directed. 31 Supply and fix in repair CTs suitable for existing LT panel board of capacity 250 to 320 Amps all as specified and as directed. 32 Supply and fix in repair CTs suitable for existing LT panel board of capacity 63 to 200 Amps all as specified and as directed. 33 Supply and fix in repair LED indicator lamps (R Y B ) suitable for existing panel all as specified and directed. 34 Supply and fix in repair digital ammeter 500amps range suitable for mounting existing panel all as specified and directed 35 Supply and fix in repair digital voltmeter 500 Volts range suitable for mounting existing panel all as specified and directed 36 Supply and fix in repair selector switches suitable for ammeter/voltmeter all as specified and as directed. 37 M & L for Earthing complete with galvanised earth plate electrode of size 600x600x6 mm thick buried directly in ground earth pit not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 mtrs below ground level connected to GI Strip of size 32x6mm upto a length of 7.5 metre long by means of bolts, nuts, washers etc. and protected by GI pipe light grade 15 mm dia and 20 mm dia GI tubing light grade with funnel for watering, all as shown in electrical plate No 3 of SSR Part-I, back-fill with salt and charcoal, provision of test point including connected to earth test point and necessary earth work excavation in any type of soil PCC (1:3:6) type C1 bed and chamber RCC (1:2:4) type B1, iron grill including GI cover with hinge and funnel watering pipe etc all as specified and directed. 38 Supply and fix in repair Display board for Pro-33 of 30 KW Solar String Inverters of make ABB complete all as specified and as directed. Make : ABB Cat (Part No YVDH0002)/ FIEMER or equivalent compatible with existing. 39 Supply and fix in repair Logic Board of 20 KW Solar String Invertersof make ABB complete all as specified and as directed. Make : ABB Cat (Part No VPBV1830E0) / FIEMER or equivalent compatible with existing. 40 Supply and fix in repair AC filter board of 20 KW Solar String Invertersof make ABB complete all as specified and as directed. Make : ABB Cat(Part No VKA.V1811.7)/ FIEMER or equivalent compatible with existing 41 Supply and fix in repair PCBA Communication board of 20 KW Solar String Invertersof make ABB complete all as specified and as directed. Make : ABB Cat(Part No VTAV06L09.3) / FIEMER or equivalent compatible with existing 42 Supply and fix in repair PCBA DC filter boardof 20 KW Solar String Invertersof make ABB complete all as specified and as directed. Make : ABB Cat (Part No 1908.0SI) / FIEMER or equivalent compatible with existing. 43 Supply and fix in repair Dehn DG M TT 275 FM of 20 KW Solar String Invertersof make ABB complete all as specified and as directed. Make : ABB Cat (Part No 3AYNAC275N-SPD) / FIEMER or equivalent compatible with existing. 44 Supply and fix in repair AC Filter boardof 30 KW Solar String Invertersof make ABB complete all as specified and as directed. Make : ABB Cat (Part NoYVD.H0027.0) / FIEMER or equivalent compatible with existing. 45 Supply and fix in repair Fuse control boardof 20 KW Solar String Inverters of make ABBcomplete all as specified and as directed. .Make : ABB Cat (Part No VTA.V0R.7.SI) / FIEMER or equivalent compatible with existing. 46 Supply and fix in repair IGBT Board of 30 KW Solar String Invertersof make ABB complete all as specified and as directed. Make : ABB Cat (Part No YVP.H0004.0) / FIEMER or equivalent compatible with existing. 47 Supply and fix in repair Negative/Positive Fuse board of 50 KW Solar String Inverters of make ABBcomplete all as specified and as directed. Make : ABB Cat (Part No VKA.V2Y36)/ FIEMER or equivalent compatible with existing. 48 Supply and fix in repair Power module external fanof 50 KW Solar String Inverters of make ABB complete all as specified and as directed. Make : ABB Cat (Part No VUD.V1U04) / FIEMER or equivalent compatible with existing 49 Supply and fix in repair Switch disconnector OT100F4N2of 50 KW Solar String Invertersof make ABB complete all as specified and as directed. Make : ABB Cat (Part No ZEC.00132)/ FIEMER or equivalent compatible with existing 50 Supply and fix in repair Power module internal fan of 50 KW Solar String Invertersof make ABB complete all as specified and as directed. Make : ABB Cat (Part No ZFV.V1U02.0) / FIEMER or equivalent compatible with existing 51 Supply and fix in repair PCBA Input fuse board negative sideof 50 KW Solar String Invertersof make ABB complete all as specified and as directed. Make : ABB Cat (Part No YVD.V2Y5W.0) / FIEMER or equivalent compatible with existing. 52 Supply and fix in repair DC Switch 4 poleof 50 KW Solar String Inverters of make ABBcomplete all as specified and as directed. Make : ABB Cat (Part No ZEC.00196) / FIEMER or equivalent compatible with existing. 53 Supply and fix in repair MCCB 400 Amps, 4 pole 415 Volts,50 Hz, 36 KA adjustable thermal setting type and confirming to IEC 60947-II complete all specified and directed. 54 Supply and fix in repair MCCB 350 Amps, 4 pole 415 Volts,50 Hz,36 KA adjustable thermal setting type and confirmingto IEC 60947-II complete all specified and directed. 55 Supply and fix in repair MCCB 200 Amps, 4 pole 36 KA adjustable thermal setting type and confirmingto IEC 60947-II complete all specified and directed. 56 Supply and fix in repair MCCB 125 Amps 4 pole 25KA, adjustable thermal setting type and confirmingto IEC 60947-II complete all specified and directed. 57 Supply and fix in repair MCCB 100 Amps 4 pole 25KA adjustable thermal setting type and confirmingto IEC 60947-II complete all specified and directed. 58 Supply and fix in repair MCCB 63 Amps 4 pole 16KA adjustable thermal setting type and confirmingto IEC 60947-II complete all specified and directed. 59 Upgradation of existing Software for SCADA System for 1 MW Solar Power Project with accesstoweb portal - server charges for 1 Years with following key components :(i) Interactive dashboard (II) Single line diagram (iii) Solar radiation & weather data (iv) Graphs and reports (v) Superuser dashboard for centralized monioring (vi) Mobile app on android & iOS 60 Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil all as specified and as directed. 61 Returning filling in excavated soil upto a depth of 30 cm after riddling of excavated soil (in lieu of sand) for cushioning of cable and refilling of trenches with left over normal excavated soil including spreading, levelling, watering and well ramming in layers complete all as specified and as directed. 62 Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. 63 Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size 250 mm x 150mm x 40mm all as specified and as directed. 64 M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate in foundation complete all as specified and directed. 65 M&L for PCC 1:3:6 type C1 using 20mm graded stone aggregate for stay and coping for poles including necessary form work to exposed surface finished smooth and even complete all as specified and directed. 66 M & L for hardcore of gauge not exceeding 63 mm of broken stone, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed 67 M&Llocal sand dry, filling in trenches around under ground cable complete all as specified and directed. 68 M& L for spreading / filling loose stone aggregate of 40mm graded complete all as specified and directed. 69 Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed. 70 M&L in repair for Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 71 Supply & fixing in repairfor Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work including hung as gates, including pintle hinges, stops, hand made sliding bolts etc conforming to Fe.290.Gde-E-165, complete all as specified and directed. 72 Supply only Chain link MS galvanised fencing, any size or type complete all as specified and directed. 73 Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed. 74 M&L for preparation of new steel surfaces of any description not other wise described over 10 cm width or grith and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. 75 Supply & fixing in repair shock treatment chart of size 1mtr x 0.5mtr printed in English, Hindi and local languageframed on all sides with wooden beading and glazing with 3mm thick ordinary glass complete all as specified and directed.