| 1 | Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in Soft/loose soil complete all as specified and directed. |
| 2 | Removing excavated material (soils) exc. 50m and n.exc 100m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 3 | Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed. |
| 4 | Excavating over areas, exc 1.5 m and n exc 3.0mdeep and getting out in soft/loose soil complete all as specified and directed. |
| 5 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, foudation of pole, stay assembly etc. or laying of LT/HT cable etc, or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out in hard/ dense soil complete all as specified and directed. |
| 6 | Returning, filling in, including spreading, levelling watering and well ramming in layers n.exc 25cm in Soft/loose soil complete all as specified and directed. |
| 7 | Removing excavated material (soils) n.exc 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 8 | Refilling under floor, including spreading, levelling watering and well ramming in layers n.exc 25cm in Soft/loose soil complete all as specified and directed. |
| 9 | M&L for cement concrete 1:4:8 type D2, using 40mm graded stone aggregate in foundation, filling and mass concrete, complete all as specified and directed. |
| 10 | M&L for reinforced cement concrete(design mix) M-30 (20mm graded aggregates ) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed. |
| 11 | M&L for reinforced cement concrete (design mix) M-30 (20mm graded aggregates ) in Columns, pillars, piers, posts and struts etc complete all as specified and directed. |
| 12 | M&L for reinforced cement concrete (design mix) M-30 (20mm graded aggregates ) in beams, cantilevers, bressumers, lintels over 1.5 clear span etc complete all as all as specified and directed. |
| 13 | M&L for reinforced cement concrete (design mix) M-30 (20mm graded aggregates ) in chajja,etc complete all as specified and directed. |
| 14 | M&L for reinforced cement concrete (design mix) M-30 (20mm graded aggregates ) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc complete all as specified and directed. |
| 15 | Use & waste of formwork to sides of concrete foundations, rough finished surfaces of flat concrete, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, etc complete all as specified and directed. |
| 16 | Use & waste of formwork to fair finished surfaces of flat concrete, sides and soffits of floor or roof beams, beam haunchings, girders, bressumers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed. |
| 17 | Use & waste of formwork to fair finished surfaces of concrete, sides of pillars, posts, struts, piers, columns and stanchions,etccircular in plan complete all as specified and directed. |
| 18 | Use & waste of formwork to fair finished surfaces of flat concrete, chullah hoods, chajjas, troughts and similar items including edges etc complete all as specified and directed. |
| 19 | Use & waste of formwork to fair finished surfaces of flat concrete, soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), etc complete all as specified and directed. |
| 20 | Use & waste of formwork to rough finished edges/surfaces of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed. |
| 21 | M & L for CRS bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed. |
| 22 | M&L for CRS bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed. |
| 23 | M&L for CRS bars 5mm and above upto and including 10mm dia in stirrups, spacers and binders cut to length bent to shape required, and binding with MS wire not less than 0.9mm dia complete all as specified and directed. |
| 24 | M&L for precast PCC block masonry type in CM 1:5:8 with soild block of any size and set in CM 1:6 complete all as specified and directed. |
| 25 | M&L for rendering 15mm thick (in two coats, 10mm 1st coat +5mm 2nd coat) to un-fair faces of brick or concrete wall surfaces in cement mortar 1:4 finished even and smooth (without using extra cement) including mixing only integral water proofing compound in second coat as per manufacturer\"s instruction. Note : a) Integral water proofing compound will be measured and paid separately. |
| 26 | M&L for rendering 10mm thick to fair faces of concrete in cement mortar 1:6including mixing only integral water proofing compound as per manufacturer\"s instruction. Note : a) Integral water proofing compond will be measured and paid separately. |
| 27 | M&L for rendering 5mm thick on concrete surfaces, on ceiling, in CM 1:3 finished even and smooth (without using extra lime or cement) complete all as specified and directed. |
| 28 | M&L for preparation of newly plastered surfaces and applying three coats of white wash on wall etc complete all as specified and directed. |
| 29 | Material & Labour for applying Two coats of 100% Premium acrylic Emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new surfaces complete all as specified and directed. |
| 30 | M&L for preparation of newly plastered surfaces & applying two coats of white wash on ceilings etc complete all as specified and directed. |
| 31 | Supply only integral waterproofing compound. |
| 32 | S&F powder coated aluminium frames including slidingtracks, etc for doors, windows, ventilators, partitions with one or more rebates including jointing cleats for fixing, fittings like hinges, handles,locks, and also standerd closing and opening systems for louvers glass etc complete all asspecifiedand as directed. |
| 33 | S&F powder coated (Thickness or powder coating not less than 50 micron) aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified. |
| 34 | M&L for 4.0 mm thick sheet glass in squares exc 0.5 sqm in each pane, etc all asspecifiedand as directed. |
| 35 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples. |
| 36 | S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and as directed. |
| 37 | S&F rolled mild steel framed work (Fe-290 Gde E-165) as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete. |
| 38 | M&L for preparation of new steel surfaces exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer all complete. |
| 39 | M&L for 100 mm thick cement concrete type D-2, 1:4:8 (40mm graded aggregate) in sub-floors, sub-bases, floors and pavings etc. |
| 40 | M&L for 100 mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) in sub-floors, sub-bases, floors and pavings etc. |
| 41 | Material and labour for cement concrete 1:3:6 type C-2, 75 mm thick using 40mmgraded stone aggregates as in plinth protection finished fair and even without using extra cement, completeall as specified and as directed. |
| 42 | M&L for Hard core of gauge n.exc 63 mm, deposited, spread and leveled in layers n exc. 15 cm thick, watered and rammed to a true surface with broken stone or boulders. |
| 43 | M&L for rendering 10mm thick on fair faces of concrete surfaces of roof as water proofing treatment, in CM 1:4 finished even and smooth (without using extra lime or cement) complete all as specified and directed. |
| 44 | M&L for water proofing treatment to roofs surfaces including a coat of applied bituminous shalitex primer @ 0.30 lit per sqm evenly on roof surface and a coat of hot bitumen 85/25 @ 1.2 kg/sqm shall be applied on primed surface and laying of 3mm thick APP modified polymeric membrane (weight not less than 3 kg/sqm) unrolled and bonded completly to the substrate with side overlap of 75 mm and end overlap of 100 mm and then sealed/fused by flame or bitumenand a coat of hot blown bitumen grade 85/25 @ 1.2 kg/sqm shall be applied on top ofAPP modified polymeric membrane as per manufacturer instruction and finally it will be finished with a coat of aluminium paint @ 0.20 kg/sqm ,complete all as specified and directed . |
| 45 | M&L for preparation of new steel surface over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete. |
| 46 | S & F rolled mild steel in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted,bolted or welded attachment, Fe 410-W (Gde-E-250) quality-A, etc |
| 47 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 grade,with grey cement and pigmentcomplete all as specified and directed. |
| 48 | M&L for point wiring complete with 4.00 Sq mm single core PVC insulated but unsheathed multistrand copper conductor FRLS cable 650/1100 Volts grade conforming to IS-694 drawn through PVC concealed conduit (minimum 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISI marked with wall thickness not less than 1.8 mm heavy duty including conduit accessories concealed pressed steel terminal boxes of size coverwhite/coloured including 2.5 Sq mm PVC insulated but unsheathed copper conductor FRLS cable as earth continuity wire for one 3 pin 15 or 16 Amps socket outlet on independent board as specified. |
| 49 | M&L for point wiring complete with 1.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FR cable 650/1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed or surface conduit as required minimum 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/recessed in wall or ceiling etc including 1.5 Sq mm PVC insulated but unsheathed multi stranded copper conductor FR cable as earth continuity wire including making good disturbed surface as per existing specification for one light point controlled by one way switch. |
| 50 | S&F modular socket out let multipurpose6 pin 15/16 Amp flush, type complete all as specified & directed. |
| 51 | M&L for modular switch 1 way 16 A, 1 module including modular cover plate with frame complete all as specified & directed. |
| 52 | M&L for module switch 1 way 6 A, 1 module including modular cover plate with frame complete all as specified & directed. |
| 53 | S&F LED batten integratedchannel20 watt (4 feet) with eye soft technology& glarefree diffuser , 50 Hz , 6500K , lumen efficiency greater than 100lm/watt , energy efficient driver, wall mounted complete including connection with flexiblecable copper conductorthree coreof size 23/.2 mm upto ceiling rose/connector. |
| 54 | S&F LED security light luminaire 1x45W on pole having IP-65, 10 KVA SPD protection with minimum system efficiency > 85%, made of pressure die cast housing, toughened glass in the front and peanut lens for batwing light distribution with excellent thermal management. The fitting should have rated CCT 5000K complete with all accessories. |
| 55 | S & F sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 08 ways, 415 Volts, ISI marked, 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed. |
| 56 | Supply and fixing of MCB TPN, 415 volt, 32 Amp capacity, 10 KA, \"C\" curve complete all as specified and directed. |
| 57 | Supply and fixing of MCB SP, 240 volt, 6 Amp to 32 Amp capacity, 10 KA, \"C\" curve complete all as specified and directed. |
| 58 | Material and labour for earthing completewith galvanizedearth plateelectrode in 60 cm x 60 cmx6 mm thick buried directly in ground verticallyat a depth not less than 2.25 meterbelowgroundlevel with top edgeof earth plateat depth not lessthan 1.5 mtrbelow ground level connecting to and including GI wire 4.00 mm dia mmby means of GI bolts, nuts, check nuts and washerlight grade,15 mm dia GI protectionpipeandconnected to equipment, GIpipe medium grade20 mmdia forwatering and includingfunnel wire mesh, RCCpitcoverand PCC 1:3:6type C-2 including Rocksalt, charcoal, excavationand earth workdisposalof surplussoil shown as plateNo 3 of SSR Part - I2009 and all as specified complete.Note : - Theunitrate quoted shalldeemed to have included for GIprotection pipe, GIearth wire up to 7.5mtr, GI waterpipe, wiremesh , funnel , excavation, RCC pitcover complete. |
| 59 | Supply and fixing in repairs LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, impact and corrosion resistant including thermal management in multiple optics with IP 66 protection, fixing on existing brackets. |
| 60 | S&F in replacement prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and 102mm x 279mm at bottom, class 10 all as specified and directed.Note: Concrete for foundation and coping for the pole will be measured and paid separately. |
| 61 | Supplying & laying factory made unreinforced Precast concrete cover of class LV, type 1,flat, size 250 mm x 150 mm x40mm for protection for cable all as specified. |
| 62 | M&L for dry sand filling in cable trenches for protection of cables with two layers(ie. 7mm and 15mm thick) below and above cable and punned down to speicified thickness complete all as specified and as directed.Note: Punned down thickness shall only be measured for payment. |
| 63 | Supply and laying/fixing GI tubing light grade for cable protection of size 50 mm dia complete all as specified and as directed. |
| 64 | Supply, laying & testing of XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables(heavy duty) with stranded aluminium conductor, 1100 volts, grade cross setional area 16 sq mm, 4.0 core complete all as specified and as directed. |
| 65 | S&F in replacement FRP based outdoor type Junction box pole Hinged (L) mounted with clamps and including MCB SP, 6 Amps complete all as specified and as directed. |
| 66 | S&F of PVC flat twin core cable of size 1.5Sqmm complete all as specified and directed. |
| 67 | Supply and fixing of MCB TPN, 415 volt, 40 to 100 Amp capacity, 10 KA, \"C\" curve complete all as specified and directed. |
| 68 | M&L for earth continuity conductor or main earth lead fixed to walls with saddles on batten or recesses or chasis or buried in ground or drawn in conduit / pipe or poles using galvanised iron strip of size 20 x 3 mm complete all as specified. |