Empanelment Of Agencies For Supply Of Laboratory Instruments For Various Water Testing Laboratories Under Jjm, Assam Empanelment Of Agencies For Supply Of Laboratory Instruments For Various Water Testing Laboratories Under Jal Jeevan Mission, Assam , Ion Meter With Electrode And Accessories For Fluoride Meter: Ph/Ise Benchtop Meter With Electrode Stable, Universal Power Adapter, Literature, Pc Cable, Meter Test Certificate Electrode: Ionplus Fluoride And Nitrate Combination Ion Selective Electrode, 1M Cable, Waterproof Bnc Benchtop Ion Meter (Ise) Along With Fluoride, Nitrate#Electrode • Range: -2.000 To 20.000 • Resolution 0.1, 0.01, 0.001 • Relative Accuracy ±0.002 Calibration Points Up To 5 • Calibration Editing Yes#Mv/ Rmv • Orp Range ±2500.0 • Mv Resolution 0.1 • Relative Accuracy ±0.2 Mv Or ±0.05 % Of Reading Whichever Is Greater • Eh Orp Mode Yes Ise • Range 0 To 19999 • Resolution Up To 3 Significant Digits • Relative Accuracy ±0.2 Mv Or ±0.05 % Of Reading Whichever Is Greater • Units Ppm, M, Mg/L, %, Ppb, None • Calibration Points Up To 5 • Calibration Editing Yes • Calibration Features Timed End Point, Linear Point To Point, Non-Linear Selectable Auto-Blank, Low Concentration Range Stability #Temperature • Range -5 To 105 °C, 23 To 221 ºf • Resolution 0.1 • Relative Accuracy ±0.1 • Offset Calibration 1-Point Datalogging • Memory 2000 With Time And Date Stamp • Log Function Manual, Ready (Include Auto-Read™), Timed • Log Edit Delete Individual Points, Group Of Points Or All Inputs • Ph Electrode Bnc, Reference Pin • Atc Probe 8-Pin Mini-Din #Output • Rs232, Usb Power • Ac Adapter Included – Universal, 100-240 Vac • Battery Power Optional – 4 Aas • Battery Life 800 Hrs , Fluoride Electrode Of Ion Meter Same Make That Of The Ion Meter , Manifold Filtration Assembly * Wide Range Of Pumps And Filtration Flasks * High Quality Components * Easily Exchangeable Elements *Maintenance-Free * Low Noise * Added Filters For Enhanced Pump Longevity * Filtration Base With Silicon Stopper, Cap & Aluminium Clamp ? Connecting Silicon Tube ?Technical Specification For Filtration Flask Set # High-Pressure Resistant Tube # Fiberglass Filter Membranes (47Mm / 0.1 ?M) # Ptfe Disc Filter #Normal Liquid Filtration * Specification For Filtration Glass Set #Suction Bottle Capacity(Ml) 1000 Ml # Filter Diameter(Mm) 47/50 Mm # * Specification For Filter Flask * Material: Statinless Steel 304, Capacity: 300 Ml (100 Ml Each) [ Unit Should Consist Of 3 Flask So That 3 Sample Can Be Filtered Simultanelously Without Any Issue] # Effective Filtration Area(Cm2) = 9.6 Cm2, Outlet Connector(Mm) = 8 Mm * Specification For Vaccum Flask: #Flow Rate Of The Pump(L/Min) = 17 L/Min Ultimate Vacuum(Mbar) = 150 Mbar # Oil Free, Maintainance Free, Built In Thermal Protection To Shut Off When Over Heated. , Auto Cut Heater For Distill Water Plant So That When Water Level Decreases The Heater Is Switch Off Automatically , Voltage Stabilizer ? Capacity- 3 Kva ? Servo Stabilizer ? 5 Star Rating , Heating Mantle (Single Station) ?Should Have Digital Energy Regulator With Multiple Step Power Regulation ? Automatic Spill Detection And Saftey Shutdown ? In Built Precision Temperature Control ? Technial Specification: Flask Capacity 250 Ml, Working Temp Range: Ambiant + 5 To 420 Degree Celcius. Accuracy: Plus Minus 1.0 Degree Celcius, Power Consumption : 150 W , Heating Mantle (Combined Unit) • Material Of Construction – Heating Block: Made With Grade Epoxy Painted Chemical Resistant Coating, Aluminum Block With 6 Thermo Wells For Processing 6 Different Samples At A Time. #Racks: Ss 316 # Glassware: Teflon Coated # • Temperature Range – Ambient + 10 Deg C To 450 Deg C # • Stability Of Temperature – Better Than ± 0.5 Deg C #• Controller – Consist Of Digital Read Out Of Temperature And Time With 4 Programmable Ramps For Each Method. # • Number Of Programmable Methods – 20 Numbers. # • Heating Powers – 1000W # • Heating Position – Minimum 6 Position # • Digestion Time Range -1 To 999 Minutes # • The System Should Have Facility Of Acoustic Signal At The End Of Completion Of Cycle To Notify The Operator. # • The Thermal Digestion Unit Should Have High Thermal Homogeneity # • The Setup Should Have Small Footprint. # • The Offer Systems Should Be Suitable To Din 38414-S7 Standard # • The Unit Should Work On 230 V / 50 Hz Ac , Digital Thermometer With Probe # Mini Lcd Thermometer #Type: Digital #Sensor Cable Length: 1 Meter Waterproof Probe # Batteries: 2 X Batteries Should Be Included # Temperature Range: -50~ 110°C # Temperature Measurement Accuracy:±1°C , Micropippete Stand #Self-Standing Holder Accommodates Most Major Brands Of Pipettes. #Material: Pmma, # Capacity: 5 Pipptes/Stand , Conical Flask Draining Rack #Material: Acrylonitrile-Butadiene-Styrene/Polycarbonate, # No. Of Pegs: 20,