Drinking Water Supply and Sanitation Government Departments Closing in 0 days TDR #49224488

Tender For Empanelment Of Agencies For Supply Of Laboratory Instruments For Various Water Testing Laboratories Under Jjm, Assam

Issued by Government Departments · guwahati, Assam
Tender Value
Ref. Documents
Estimated cost
Bid Submission
04 Jul 2025
0 days left
EMD
1.40 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
guwahati → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Empanelment Of Agencies For Supply Of Laboratory Instruments For Various Water Testing Laboratories Under Jjm, Assam Empanelment Of Agencies For Supply Of Laboratory Instruments For Various Water Testing Laboratories Under Jal Jeevan Mission, Assam , Ion Meter With Electrode And Accessories For Fluoride Meter: Ph/Ise Benchtop Meter With Electrode Stable, Universal Power Adapter, Literature, Pc Cable, Meter Test Certificate Electrode: Ionplus Fluoride And Nitrate Combination Ion Selective Electrode, 1M Cable, Waterproof Bnc Benchtop Ion Meter (Ise) Along With Fluoride, Nitrate#Electrode • Range: -2.000 To 20.000 • Resolution 0.1, 0.01, 0.001 • Relative Accuracy ±0.002 Calibration Points Up To 5 • Calibration Editing Yes#Mv/ Rmv • Orp Range ±2500.0 • Mv Resolution 0.1 • Relative Accuracy ±0.2 Mv Or ±0.05 % Of Reading Whichever Is Greater • Eh Orp Mode Yes Ise • Range 0 To 19999 • Resolution Up To 3 Significant Digits • Relative Accuracy ±0.2 Mv Or ±0.05 % Of Reading Whichever Is Greater • Units Ppm, M, Mg/L, %, Ppb, None • Calibration Points Up To 5 • Calibration Editing Yes • Calibration Features Timed End Point, Linear Point To Point, Non-Linear Selectable Auto-Blank, Low Concentration Range Stability #Temperature • Range -5 To 105 °C, 23 To 221 ºf • Resolution 0.1 • Relative Accuracy ±0.1 • Offset Calibration 1-Point Datalogging • Memory 2000 With Time And Date Stamp • Log Function Manual, Ready (Include Auto-Read™), Timed • Log Edit Delete Individual Points, Group Of Points Or All Inputs • Ph Electrode Bnc, Reference Pin • Atc Probe 8-Pin Mini-Din #Output • Rs232, Usb Power • Ac Adapter Included – Universal, 100-240 Vac • Battery Power Optional – 4 Aas • Battery Life 800 Hrs , Fluoride Electrode Of Ion Meter Same Make That Of The Ion Meter , Manifold Filtration Assembly * Wide Range Of Pumps And Filtration Flasks * High Quality Components * Easily Exchangeable Elements *Maintenance-Free * Low Noise * Added Filters For Enhanced Pump Longevity * Filtration Base With Silicon Stopper, Cap & Aluminium Clamp ? Connecting Silicon Tube ?Technical Specification For Filtration Flask Set # High-Pressure Resistant Tube # Fiberglass Filter Membranes (47Mm / 0.1 ?M) # Ptfe Disc Filter #Normal Liquid Filtration * Specification For Filtration Glass Set #Suction Bottle Capacity(Ml) 1000 Ml # Filter Diameter(Mm) 47/50 Mm # * Specification For Filter Flask * Material: Statinless Steel 304, Capacity: 300 Ml (100 Ml Each) [ Unit Should Consist Of 3 Flask So That 3 Sample Can Be Filtered Simultanelously Without Any Issue] # Effective Filtration Area(Cm2) = 9.6 Cm2, Outlet Connector(Mm) = 8 Mm * Specification For Vaccum Flask: #Flow Rate Of The Pump(L/Min) = 17 L/Min Ultimate Vacuum(Mbar) = 150 Mbar # Oil Free, Maintainance Free, Built In Thermal Protection To Shut Off When Over Heated. , Auto Cut Heater For Distill Water Plant So That When Water Level Decreases The Heater Is Switch Off Automatically , Voltage Stabilizer ? Capacity- 3 Kva ? Servo Stabilizer ? 5 Star Rating , Heating Mantle (Single Station) ?Should Have Digital Energy Regulator With Multiple Step Power Regulation ? Automatic Spill Detection And Saftey Shutdown ? In Built Precision Temperature Control ? Technial Specification: Flask Capacity 250 Ml, Working Temp Range: Ambiant + 5 To 420 Degree Celcius. Accuracy: Plus Minus 1.0 Degree Celcius, Power Consumption : 150 W , Heating Mantle (Combined Unit) • Material Of Construction – Heating Block: Made With Grade Epoxy Painted Chemical Resistant Coating, Aluminum Block With 6 Thermo Wells For Processing 6 Different Samples At A Time. #Racks: Ss 316 # Glassware: Teflon Coated # • Temperature Range – Ambient + 10 Deg C To 450 Deg C # • Stability Of Temperature – Better Than ± 0.5 Deg C #• Controller – Consist Of Digital Read Out Of Temperature And Time With 4 Programmable Ramps For Each Method. # • Number Of Programmable Methods – 20 Numbers. # • Heating Powers – 1000W # • Heating Position – Minimum 6 Position # • Digestion Time Range -1 To 999 Minutes # • The System Should Have Facility Of Acoustic Signal At The End Of Completion Of Cycle To Notify The Operator. # • The Thermal Digestion Unit Should Have High Thermal Homogeneity # • The Setup Should Have Small Footprint. # • The Offer Systems Should Be Suitable To Din 38414-S7 Standard # • The Unit Should Work On 230 V / 50 Hz Ac , Digital Thermometer With Probe # Mini Lcd Thermometer #Type: Digital #Sensor Cable Length: 1 Meter Waterproof Probe # Batteries: 2 X Batteries Should Be Included # Temperature Range: -50~ 110°C # Temperature Measurement Accuracy:±1°C , Micropippete Stand #Self-Standing Holder Accommodates Most Major Brands Of Pipettes. #Material: Pmma, # Capacity: 5 Pipptes/Stand , Conical Flask Draining Rack #Material: Acrylonitrile-Butadiene-Styrene/Polycarbonate, # No. Of Pegs: 20,

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 25-Jun-2025 DATE CORRIGENDUM - 02 Date 04-Jul-2025
2 16-Jun-2025 DATE CORRIGENDUM - 01 Date 24-Jun-2025
3 18-Jun-2025 Technical Corrigendum - 01 Technical Bid 24-Jun-2025

BOQ

Name of Work : \"EMPANELMENT OF AGENCIES FOR SUPPLY OF LABORATORY INSTRUMENTS FOR VARIOUS WATER TESTING LABORATORIES UNDER JAL JEEVAN MISSION, ASSAM.\"
Sl. No. Item Description
1Ion meter with Electrode and accessories for fluorideMeter: pH/ISE Benchtop meter with electrode stable, Universal power adapter, Literature, PC cable, meter test certificate electrode: Ionplus Fluoride and Nitrate Combination Ion Selective Electrode, 1m Cable, Waterproof BNC Benchtop Ion meter (ISE) along with Fluoride, Nitrate#Electrode • Range: -2.000 to 20.000 • Resolution 0.1, 0.01, 0.001 • Relative Accuracy ±0.002 Calibration Points Up to 5 • Calibration Editing Yes#mV/ RmV • ORP Range ±2500.0 • mV Resolution 0.1 • Relative Accuracy ±0.2 mV or ±0.05 % of reading whichever is greater • EH ORP Mode Yes ISE • Range 0 to 19999 • Resolution Up to 3 significant digits • Relative Accuracy ±0.2 mV or ±0.05 % of reading whichever is greater • Units ppm, M, mg/L, %, ppb, none • Calibration Points Up to 5 • Calibration Editing Yes • Calibration Features Timed end point, linear point to point, non-linear selectable auto-blank, low concentration range stability #Temperature • Range -5 to 105 °C, 23 to 221 ºF • Resolution 0.1 • Relative Accuracy ±0.1 • Offset Calibration 1-point Datalogging • Memory 2000 with time and date stamp • Log Function Manual, ready (include AUTO-READ™), timed • Log Edit Delete individual points, group of points or all Inputs • pH Electrode BNC, reference pin • ATC Probe 8-pin mini-DIN #Output • RS232, USB Power • AC Adapter Included – universal, 100-240 VAC • Battery Power Optional – 4 AAs • Battery Life 800 hrs
2Fluoride Electrode of Ion MeterSame Make that of the Ion Meter
3Manifold filtration Assembly* Wide range of pumps and filtration flasks * High quality components * Easily exchangeable elements *Maintenance-free * Low noise * Added filters for enhanced pump longevity * filtration base with silicon stopper, cap & Aluminium clamp ⋆ connecting silicon tube ⋆Technical Specification for filtration flask set # High-pressure resistant tube # Fiberglass filter membranes (47mm / 0.1 μm) # PTFE disc filter #Normal liquid filtration * Specification for Filtration Glass Set #Suction Bottle Capacity(ml) 1000 ml # Filter Diameter(mm) 47/50 mm # * Specification for Filter Flask * Material: Statinless Steel 304, Capacity: 300 mL (100 mL each) [ Unit should consist of 3 flask so that 3 sample can be filtered simultanelously without any issue] # Effective Filtration Area(cm2) = 9.6 cm2, Outlet Connector(mm) = 8 mm * Specification for Vaccum Flask: #Flow Rate of the Pump(l/min) = 17 l/minUltimate Vacuum(mbar) = 150 mbar # oil free, maintainance free, built in thermal protection to shut off when over heated.
4Auto cut heater For distill water plant so that when water level decreases the heater is switch off automatically
5Voltage stabilizer⋆ Capacity- 3 KVA ⋆ servo stabilizer ⋆ 5 star rating
6Heating Mantle (Single station)⋆Should have digital energy regulator with multiple step power regulation ⋆ Automatic spill detection and saftey shutdown ⋆ In built precision temperature control ⋆ Technial specification: Flask capacity 250 mL, working Temp range: Ambiant + 5 to 420 degree celcius. Accuracy: plus minus 1.0 degree celcius, Power consumption : 150 W
7Heating Mantle (Combined Unit)• Material of construction – Heating Block: Made with grade Epoxy painted chemical resistant coating, aluminum block with 6 thermo wells for processing 6 different samples at a time. #Racks: SS 316 # Glassware: Teflon coated # • Temperature Range – Ambient + 10 Deg C to 450 Deg C # • Stability of Temperature – Better than ± 0.5 Deg C #• Controller – Consist of digital read out of temperature and time with 4 programmable ramps for each method. # • Number of Programmable Methods – 20 numbers. # • Heating Powers – 1000W # • Heating Position – minimum 6 position # • Digestion time range -1 to 999 minutes # • The system should have facility of acoustic signal at the end of completion of cycle to notify the operator. # • The thermal digestion unit should have high thermal homogeneity # • The setup should have small footprint. # • The offer systems should be suitable to DIN 38414-S7 STANDARD # • The unit should work on 230 V / 50 HZ AC
8Digital Thermometer with probe# Mini LCD thermometer #Type: Digital #Sensor cable length: 1 meter waterproof probe # Batteries: 2 x Batteries should be included # Temperature range: -50~ 110°C # Temperature measurement accuracy:±1°C
9Micropippete Stand#Self-standing holder accommodates most major brands of pipettes. #Material: PMMA, # Capacity: 5 pipptes/stand
10Conical flask draining rack#Material: Acrylonitrile-Butadiene-Styrene/polycarbonate, # No. of Pegs: 20,

AI Tender Summary

OUR REF NO 49224488
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 04-07-2025
Authority
Authority Name Public Health Engineering Department
Work Description Empanelment Of Agencies For Supply Of Laboratory Instruments For Various Water Testing Laboratories Under Jjm, Assam Empanelment Of Agencies For Supply Of Laboratory Instruments For Various Water Testing Laboratories Under Jal Jeevan Mission, Assam , Ion Meter With Electrode And Accessories For Fluoride Meter: Ph/Ise Benchtop Meter With Electrode Stable, Universal Power Adapter, Literature, Pc Cable, Meter Test Certificate Electrode: Ionplus Fluoride And Nitrate Combination Ion Selective Electrode, 1M Cable, Waterproof Bnc Benchtop Ion Meter (Ise) Along With Fluoride, Nitrate#Electrode • Range: -2.000 To 20.000 • Resolution 0.1, 0.01, 0.001 • Relative Accuracy ±0.002 Calibration Points Up To 5 • Calibration Editing Yes#Mv/ Rmv • Orp Range ±2500.0 • Mv Resolution 0.1 • Relative Accuracy ±0.2 Mv Or ±0.05 % Of Reading Whichever Is Greater • Eh Orp Mode Yes Ise • Range 0 To 19999 • Resolution Up To 3 Significant Digits • Relative Accuracy ±0.2 Mv Or ±0.05 % Of Reading Whichever Is Greater • Units Ppm, M, Mg/L, %, Ppb, None • Calibration Points Up To 5 • Calibration Editing Yes • Calibration Features Timed End Point, Linear Point To Point, Non-Linear Selectable Auto-Blank, Low Concentration Range Stability #Temperature • Range -5 To 105 °C, 23 To 221 ºf • Resolution 0.1 • Relative Accuracy ±0.1 • Offset Calibration 1-Point Datalogging • Memory 2000 With Time And Date Stamp • Log Function Manual, Ready (Include Auto-Read™), Timed • Log Edit Delete Individual Points, Group Of Points Or All Inputs • Ph Electrode Bnc, Reference Pin • Atc Probe 8-Pin Mini-Din #Output • Rs232, Usb Power • Ac Adapter Included – Universal, 100-240 Vac • Battery Power Optional – 4 Aas • Battery Life 800 Hrs , Fluoride Electrode Of Ion Meter Same Make That Of The Ion Meter , Manifold Filtration Assembly * Wide Range Of Pumps And Filtration Flasks * High Quality Components * Easily Exchangeable Elements *Maintenance-Free * Low Noise * Added Filters For Enhanced Pump Longevity * Filtration Base With Silicon Stopper, Cap & Aluminium Clamp ? Connecting Silicon Tube ?Technical Specification For Filtration Flask Set # High-Pressure Resistant Tube # Fiberglass Filter Membranes (47Mm / 0.1 ?M) # Ptfe Disc Filter #Normal Liquid Filtration * Specification For Filtration Glass Set #Suction Bottle Capacity(Ml) 1000 Ml # Filter Diameter(Mm) 47/50 Mm # * Specification For Filter Flask * Material: Statinless Steel 304, Capacity: 300 Ml (100 Ml Each) [ Unit Should Consist Of 3 Flask So That 3 Sample Can Be Filtered Simultanelously Without Any Issue] # Effective Filtration Area(Cm2) = 9.6 Cm2, Outlet Connector(Mm) = 8 Mm * Specification For Vaccum Flask: #Flow Rate Of The Pump(L/Min) = 17 L/Min Ultimate Vacuum(Mbar) = 150 Mbar # Oil Free, Maintainance Free, Built In Thermal Protection To Shut Off When Over Heated. , Auto Cut Heater For Distill Water Plant So That When Water Level Decreases The Heater Is Switch Off Automatically , Voltage Stabilizer ? Capacity- 3 Kva ? Servo Stabilizer ? 5 Star Rating , Heating Mantle (Single Station) ?Should Have Digital Energy Regulator With Multiple Step Power Regulation ? Automatic Spill Detection And Saftey Shutdown ? In Built Precision Temperature Control ? Technial Specification: Flask Capacity 250 Ml, Working Temp Range: Ambiant + 5 To 420 Degree Celcius. Accuracy: Plus Minus 1.0 Degree Celcius, Power Consumption : 150 W , Heating Mantle (Combined Unit) • Material Of Construction – Heating Block: Made With Grade Epoxy Painted Chemical Resistant Coating, Aluminum Block With 6 Thermo Wells For Processing 6 Different Samples At A Time. #Racks: Ss 316 # Glassware: Teflon Coated # • Temperature Range – Ambient + 10 Deg C To 450 Deg C # • Stability Of Temperature – Better Than ± 0.5 Deg C #• Controller – Consist Of Digital Read Out Of Temperature And Time With 4 Programmable Ramps For Each Method. # • Number Of Programmable Methods – 20 Numbers. # • Heating Powers – 1000W # • Heating Position – Minimum 6 Position # • Digestion Time Range -1 To 999 Minutes # • The System Should Have Facility Of Acoustic Signal At The End Of Completion Of Cycle To Notify The Operator. # • The Thermal Digestion Unit Should Have High Thermal Homogeneity # • The Setup Should Have Small Footprint. # • The Offer Systems Should Be Suitable To Din 38414-S7 Standard # • The Unit Should Work On 230 V / 50 Hz Ac , Digital Thermometer With Probe # Mini Lcd Thermometer #Type: Digital #Sensor Cable Length: 1 Meter Waterproof Probe # Batteries: 2 X Batteries Should Be Included # Temperature Range: -50~ 110°C # Temperature Measurement Accuracy:±1°C , Micropippete Stand #Self-Standing Holder Accommodates Most Major Brands Of Pipettes. #Material: Pmma, # Capacity: 5 Pipptes/Stand , Conical Flask Draining Rack #Material: Acrylonitrile-Butadiene-Styrene/Polycarbonate, # No. Of Pegs: 20,
Basic Detail
Tender No JJMA_27_Lab_2024_2534_39
Bidding Type Tender
Location
City guwahati
State Assam
Key Dates
Publish Date 25 Jun 2025
Submission Date 04 Jul 2025
Open Date 05 Jul 2025
Finance
Tender Value Ref. Documents
Tender Fee 2000
EMD 1.40 Lakhs
Exemption Available
Document List
RFP_03_2025_26.pdf
Tendernotice_1.pdf
54660f15-c2f4-46cf-81e0-cdc953da7f35.html
BOQ_70664.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 25, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 04, 2025
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 24, 2025
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 24, 2025
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 04, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 05, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

RFP_03_2025_26.pdf

pdf

Tendernotice_1.pdf

html

54660f15-c2f4-46cf-81e0-cdc953da7f35.html

xls

BOQ_70664.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders