| 1 | Ion meter with Electrode and accessories for fluorideMeter: pH/ISE Benchtop meter with electrode stable, Universal power adapter, Literature, PC cable, meter test certificate electrode: Ionplus Fluoride and Nitrate Combination Ion Selective Electrode, 1m Cable, Waterproof BNC Benchtop Ion meter (ISE) along with Fluoride, Nitrate#Electrode • Range: -2.000 to 20.000 • Resolution 0.1, 0.01, 0.001 • Relative Accuracy ±0.002 Calibration Points Up to 5 • Calibration Editing Yes#mV/ RmV • ORP Range ±2500.0 • mV Resolution 0.1 • Relative Accuracy ±0.2 mV or ±0.05 % of reading whichever is greater • EH ORP Mode Yes ISE • Range 0 to 19999 • Resolution Up to 3 significant digits • Relative Accuracy ±0.2 mV or ±0.05 % of reading whichever is greater • Units ppm, M, mg/L, %, ppb, none • Calibration Points Up to 5 • Calibration Editing Yes • Calibration Features Timed end point, linear point to point, non-linear selectable auto-blank, low concentration range stability #Temperature • Range -5 to 105 °C, 23 to 221 ºF • Resolution 0.1 • Relative Accuracy ±0.1 • Offset Calibration 1-point Datalogging • Memory 2000 with time and date stamp • Log Function Manual, ready (include AUTO-READ™), timed • Log Edit Delete individual points, group of points or all Inputs • pH Electrode BNC, reference pin • ATC Probe 8-pin mini-DIN #Output • RS232, USB Power • AC Adapter Included – universal, 100-240 VAC • Battery Power Optional – 4 AAs • Battery Life 800 hrs |
| 2 | Fluoride Electrode of Ion MeterSame Make that of the Ion Meter |
| 3 | Manifold filtration Assembly* Wide range of pumps and filtration flasks * High quality components * Easily exchangeable elements *Maintenance-free * Low noise * Added filters for enhanced pump longevity * filtration base with silicon stopper, cap & Aluminium clamp ⋆ connecting silicon tube ⋆Technical Specification for filtration flask set # High-pressure resistant tube # Fiberglass filter membranes (47mm / 0.1 μm) # PTFE disc filter #Normal liquid filtration * Specification for Filtration Glass Set #Suction Bottle Capacity(ml) 1000 ml # Filter Diameter(mm) 47/50 mm # * Specification for Filter Flask * Material: Statinless Steel 304, Capacity: 300 mL (100 mL each) [ Unit should consist of 3 flask so that 3 sample can be filtered simultanelously without any issue] # Effective Filtration Area(cm2) = 9.6 cm2, Outlet Connector(mm) = 8 mm * Specification for Vaccum Flask: #Flow Rate of the Pump(l/min) = 17 l/minUltimate Vacuum(mbar) = 150 mbar # oil free, maintainance free, built in thermal protection to shut off when over heated. |
| 4 | Auto cut heater For distill water plant so that when water level decreases the heater is switch off automatically |
| 5 | Voltage stabilizer⋆ Capacity- 3 KVA ⋆ servo stabilizer ⋆ 5 star rating |
| 6 | Heating Mantle (Single station)⋆Should have digital energy regulator with multiple step power regulation ⋆ Automatic spill detection and saftey shutdown ⋆ In built precision temperature control ⋆ Technial specification: Flask capacity 250 mL, working Temp range: Ambiant + 5 to 420 degree celcius. Accuracy: plus minus 1.0 degree celcius, Power consumption : 150 W |
| 7 | Heating Mantle (Combined Unit)• Material of construction – Heating Block: Made with grade Epoxy painted chemical resistant coating, aluminum block with 6 thermo wells for processing 6 different samples at a time. #Racks: SS 316 # Glassware: Teflon coated # • Temperature Range – Ambient + 10 Deg C to 450 Deg C # • Stability of Temperature – Better than ± 0.5 Deg C #• Controller – Consist of digital read out of temperature and time with 4 programmable ramps for each method. # • Number of Programmable Methods – 20 numbers. # • Heating Powers – 1000W # • Heating Position – minimum 6 position # • Digestion time range -1 to 999 minutes # • The system should have facility of acoustic signal at the end of completion of cycle to notify the operator. # • The thermal digestion unit should have high thermal homogeneity # • The setup should have small footprint. # • The offer systems should be suitable to DIN 38414-S7 STANDARD # • The unit should work on 230 V / 50 HZ AC |
| 8 | Digital Thermometer with probe# Mini LCD thermometer #Type: Digital #Sensor cable length: 1 meter waterproof probe # Batteries: 2 x Batteries should be included # Temperature range: -50~ 110°C # Temperature measurement accuracy:±1°C |
| 9 | Micropippete Stand#Self-standing holder accommodates most major brands of pipettes. #Material: PMMA, # Capacity: 5 pipptes/stand |
| 10 | Conical flask draining rack#Material: Acrylonitrile-Butadiene-Styrene/polycarbonate, # No. of Pegs: 20, |