Drinking Water Supply and Sanitation Government Departments Closing in 57 days TDR #49223408

Tender for Work of Drinking Water Supply Project for 1473 villages of Chittorgarh, Pratapgarh, Rajsamand & Udaipur District from Jakham Dam under Jal Jeevan Mission (Package-1 :- WTP, IPS-1 to IPS-6, CPS-01 to 19 including complete works of these CPS, CD -VD & Civil works for 93 villages of Chhoti Sadri block of Pratapgarh, 707 villages of 7 blocks of Chittorgarh district) under JJM With Operation and Maintenance for Ten (10) Years including Defect Liability Period of One (1) Year on Hybrid Annuity Model (HAM).

Issued by Government Departments · chittorgarh, Rajasthan
Tender Value
1692.30 Crore
Estimated cost
Bid Submission
16 Sep 2026
57 days left
EMD
8.46 Crore
Bank guarantee accepted
Document Fee
2500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
chittorgarh → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Work of Drinking Water Supply Project for 1473 villages of Chittorgarh, Pratapgarh, Rajsamand & Udaipur District from Jakham Dam under Jal Jeevan Mission (Package-1 :- WTP, IPS-1 to IPS-6, CPS-01 to 19 including complete works of these CPS, CD -VD & Civil works for 93 villages of Chhoti Sadri block of Pratapgarh, 707 villages of 7 blocks of Chittorgarh district) under JJM With Operation and Maintenance for Ten (10) Years including Defect Liability Period of One (1) Year on Hybrid Annuity Model (HAM).

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 22-Jul-2025 Corrigendum no. 5 Technical Bid 28-Jul-2025
2 25-Jul-2025 Corrigendum no. 06 BID Submission end date and open date change Date 08-Sep-2025
3 17-Jun-2025 Corrigendum no. 4 Bid date extended Date 28-Jul-2025
4 24-Dec-2025 corrigendum 9 Date 16-Feb-2026
5 24-Oct-2025 corrigendum 8 Date 29-Dec-2025
6 05-Sep-2025 corrigendum 7 Date 27-Oct-2025
7 11-Feb-2026 corrigendum 10 Date 16-Apr-2026
8 15-Apr-2026 Corrigendum No.11 Date 18-Jun-2026
9 11-Feb-2026 corrigendum 10 Date 16-Apr-2026
10 24-Dec-2025 corrigendum 9 Date 16-Feb-2026
11 24-Oct-2025 corrigendum 8 Date 29-Dec-2025
12 05-Sep-2025 corrigendum 7 Date 27-Oct-2025
13 25-Jul-2025 Corrigendum no. 06 BID Submission end date and open date change Date 08-Sep-2025
14 22-Jul-2025 Corrigendum no. 5 Technical Bid 18-Jun-2026
15 17-Jun-2025 Corrigendum no. 4 Bid date extended Date 28-Jul-2025
16 15-Apr-2026 Corrigendum No.11 Date 18-Jun-2026
17 11-Feb-2026 corrigendum 10 Date 16-Apr-2026
18 24-Dec-2025 corrigendum 9 Date 16-Feb-2026
19 24-Oct-2025 corrigendum 8 Date 29-Dec-2025
20 05-Sep-2025 corrigendum 7 Date 27-Oct-2025
21 25-Jul-2025 Corrigendum no. 06 BID Submission end date and open date change Date 08-Sep-2025
22 22-Jul-2025 Corrigendum no. 5 Technical Bid 16-Sep-2026
23 17-Jun-2025 Corrigendum no. 4 Bid date extended Date 28-Jul-2025
24 16-Jun-2026 Corrigendum no 12 Date 16-Sep-2026

BOQ

Name of Work: Drinking Water Supply Project for 1473 villages of Chittorgarh, Pratapgarh, Rajsamand & Udaipur District (Package-1 WTP, IPS-1 to IPS-6, CPS-01 to 19 including complete works of these CPS, CD -VD & Civil works for 93 villages of Chhoti Sadri block of Pratapgarh,707 villages of 7 blocks of Chittorgarh district under Jal Jeevan Mission with Operation and Maintenance for Ten (10) Years After Defect Liability Period of One (1) Year
Sl. No. Item Description
1Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-9 grade S&S pipes as per IS:8329-2000 (amended upto date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge.excluding earth work)Note : Providing and fixing of all requisite specials as perdrawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately
2150 mm
3200 mm
4250 mm
5500 mm
6Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended upto date), with internal cement mortar lining suitable for potable water with rubber ring (EPDM) joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in- charge.(excluding earth work)Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.
7100 mm
8150 mm
9200 mm
10250 mm
11300 mm
12350 mm
13400 mm
14450 mm
15500 mm
16600 mm
17700 mm
18800 mm
19Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended up to date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) .Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M.
20HDPE PE-100PN-6
2163 mm dia
2275 mm dia
2390 mm dia
24110 mm dia
25Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications anddirection of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply of pipe shall be in straight length in 6/12 M.
26HDPE PE-100 PN-6
27125 mm dia
28140 mm dia
29160 mm dia
30180 mm dia
31200 mm dia
32225 mm dia
33Providing, lowering, laying and jointing in trenches,standard lengths ISI marked Rigid PVC-O S/S Pipes (push on joints) as per IS-16647: 2017 (amended up to date)with EPDM Gasket seals on jointsincluding all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, laying of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter.Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.
34PVC-O pipe Class 500PN-12.5
35110 mm dia
36160 mm dia
37200 mm dia
38Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.), field joints,satisfactory hydraulic testing, disinfection, commissioning etc. completeas per technical specifications anddirection of Engineer-in-charge; (excluding earthwork, internal lining and outer coating). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.For Laying Pipe
391219 mm dia 10 mm thick
401219 mm dia 12.5 mm thick
41Providing and applying 3LPE (3 Layer Polyethylene) tape coating conforming to ISO 21809-1, DIN 30670-91 or CAN/CSA Z245.20-10 to external surface of M.S. Pipe comprising of a layer of fusion bonded epoxy (FBE), overlaid with PE adhesive with an outer layer of high density polyethyleneincluding preparation of surface by solvent cleaning, abrasive blasting to a finish of Grade 2.5 to DIN EN ISO 8501-1 and surface profile of 50 to 75 microns as per DIN EN ISO 8503-2. Minimum thickness of FBE shall be 250 microns including field joints coating at site complete as per technical specification and direction of Engineer-in-Charge.Minimum thickness of coating shall be 3.0 mm on weld seam as well as remaining surface.
42Providing and applying Solvent free, two pack liquid epoxy lining to internal surface of M.S. Pipe as per BS 6920:2000 and AWWA C210 standard including preparation of internal surface of pipe by cleaning and abrasive blasting including field joints coating at site complete as per technical specification and direction of Engineer in In charge. Liquid Epoxy shall be NSF/WARS approved for drinking water and minimum thickness of lining shall be 406 microns.
43Providing and fixing double flanged ISI marked DIClass K-9 pipes as per IS:8329-2000 (amended up to date), asvertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr,jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.Note: The rates for DI double flanged pipes shall be reduced 5%, if used other than OHSR pipes.
44100 mm
45200 mm
46250 mm
47300 mm
48350 mm
49400 mm
50500 mm
51600 mm
52700 mm
53Manufacturing, supplying ,lowering, laying and jointing in position to correct line spirally welded SAW/Fabricated MS Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for following thickness and inside diameter, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.), field joints,satisfactory hydraulic testing, disinfection, commissioning etc. completeas per technical specifications anddirection of Engineer-in-charge; (excluding earthwork, internal lining and outer coating). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. for Paddle collar
54813 mm dia 8 mm thick
551016 mm dia 10 mm thick
561219 mm dia 11 mm thick
572032 mm dia 16 mm thick
58Providing and fixing double flanged ISI marked DIClass K-9 pipes as per IS:8329-2000 (amended up to date), asvertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr,jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.
59100 mm dia
60150 mm dia
61200 mm dia
62250 mm dia
63300 mm dia
64Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.
65In all types of Soils
66upto 1.5 m
67Above 1.5 mtr and up to 3.0 mtr.
68In Soft Rock
69upto 1.5 m
70Above 1.5 mtr and up to 3.0 mtr.
71In Hard Rock (Blasting Required)
72upto 1.5 m
73Above 1.5 mtr and up to 3.0 mtr.
74In Hard Rock (Blasting Probihited)
75upto 1.5 m
76Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand.
77Supplying and Filling in plinth with river sand under floors including watering ramming consolidating and dressing complete including cost of sand
78Carriage of material sand, bajri etc. upto 25 Km
79Providing, lowering, aligning, fixing in position and Jointing in pipe line, DI Body Flanged End Tamper proof Kinetic Air Valve of approved makes of following pressure rating and dia and as per following specifications: Governing standard - AWWA C512/ IS:14845:2000(amended up to date) Body, High pressure cover , Low pressure cover, Cowl and Joint support ring - Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, FloatLP ball & HP ball : AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBR ,HP Orifice & HP orifice plug : Bronze/ SS ,Bush: Bronze ,Flanges as per IS/ BS, Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & cover inside and outside .Fasteners - CS/ Galvanised steel, Outlet of big orifice will have a screen to prevent Tamper of float, with DI metal seated D/F Non rising stem. Sluice Valves as per (IS: 14846 amended upto date) PN 1.6 ratings. Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work
80Class PN 1.6
8150 mm dia
8280 mm dia
83100 mm dia
84150 mm dia
85200 mm dia
86Construction of RCC pillar for following size of air valves including earthwork excavation,RCC M25 grade for base slab, vertical pillar, including cost of steel reinforcement ,GI (class-B)/MS vertical pipe, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as per direction of Engineer-in-Charge.
87Air valve pillarfor airvalves size of 80mmdia
88Air valve pillarfor airvalves size of 100mmdia
89Air valve pillarfor airvalves size of 150mmdia
90Air valve pillarfor airvalves size of 200mmdia
91Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalves forScour Valvestraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - AISI- 410 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
92Manually Operated CI Sluice valve of Class PN-1.0
9380 mm HW
94100 mm HW
95125 mm HW
96150 mm HW
97200 mm HW
98250 mm HW
99400 mm with Gear
100Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS AISI 316/410 Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
101Manually Operated Resilient Seated Sluice Valves of Class PN 1.6
10280 mm dia
103100 mm dia
104125 mm dia
105150 mm dia
106200 mm dia
107250 mm dia
108300 mm dia
109350 mm dia
110400 mm dia
111450 mm dia
112500 mm dia
113600 mm dia
1141100 mm dia
1151400 mm dia
116Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS AISI 316/410 Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
117Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6
118100 mm dia
119150 mm dia
120200 mm dia
121250 mm dia
122350 mm dia
123400 mm dia
124Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves of approved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amendedup to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 410/316 & shaft bearings-bronze/ PTET or Teflon with EPDM/NBR \"O \"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
125Class PN 1.6, Manually Operated with Gear
126350 mm dia
127400 mm dia
128450 mm dia
129500 mm dia
130600 mm dia
131700 mm dia
132800 mm dia.
1331000 mm dia.
1341200 mm dia
1351600 mm
136Class PN 2.5, Manually Operated with Gear
137450 mm dia
138Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) short body pattern type double eccentric Butterfly valves of approved make of following class & dia complete confirming to BS EN 593/ BS 5155/ IS 13095/1991 amendedup to date and of following specifications: Body, disc and end cover of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per DIN 3202 F4/ IS 13095Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on both body and disc inside and outside. Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 410/316 & shaft bearings-bronze/ PTET or Teflon with EPDM/NBR \"O \"ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
139Class PN 1.6, Motorised Operated
140350 mm dia
141400 mm dia
142450 mm dia
143700 mm dia.
144Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specificationscompleteofthefollowingsizesincludingall jointing material,costofalllabour,testingandcommissioning Technical Specifications and as per direction of Engineer. Class PN 1.0
14580 mm dia
146100 mm dia
147125 mm dia
148150 mm dia
149200 mm dia
150250 mm dia
151300 mm dia
152350 mm dia
153400 mm dia
154450 mm dia
155500 mm dia
156600 mm dia
157Providing, lowering, laying, aligning, fixing in position and jointing MS dismantling joint (Fabricated Steel)as per IS specificationscompleteofthefollowingsizesincludingall jointing material,costofalllabour,testingandcommissioning Technical Specifications and as per direction of Engineer.
15880 mm dia
159100 mm dia
160150 mm dia
161200 mm dia
162250 mm dia
163300 mm dia
164350 mm dia
165400 mm dia
166450 mm dia
167500 mm dia
168600 mm dia
169700 mm dia
170800 mm dia
1711000 mm dia
1721100 mm dia
1731200 mm dia
1741600 mm dia
1751400 mm dia
176Providing, installation, testing and commissioning of following Stain less steel AISI 304 Expansion bellows of 10/16 bar rating with tie rods as per technical specifications and layout drawings including jointing material like nuts, bolts, rubber gaskets etc. complete in all respect as per technical specification and as per direction of Engineer.
177150 mm dia.
178250 mm dia.
179350 mm dia.
180400 mm dia.
181450 mm dia.
182Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) Swing type Non Return Valve of approved make of following Pressure rating & dia complete, generally confirming to IS: 5312 (part -1)/ 2004 (amendedup to date) and of following specifications: Body, Bonnet & disc of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions,Face to face dimensions as per IS 5312 (part -1):2004Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body, cover and disc inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS.Shaft of SS- AISI- 410, Hinge SS AISI 316/410 ,Bonnet Gasket EPDM ,Bush- Brasswith EPDM/NBR \"O \"ring seal Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel)Insertion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
183Class PN 1.6
184100 mm dia
185150 mm dia
186200 mm dia
187250 mm dia
188350 mm dia
189450 mm dia
190Supplying, erecting, testing & commissioning of ElectricallyOperated Travelling Crane (EOT) .Main girder & End Carriagefabricated from Rollled Steel Section, Gear Box for all motion,Electro Magnetic Friction Disc Type Brakes, all safety limit switches,LT wheels EN 9, Double Flanged 4No, with Sq. Cage motor ofadequate rating (KW), duly painted mechanical cleaning and onecoat of primer and two coat of synthetic paint and as per thedirection of the Engineer.
1912 MT Capacity (Span 7 M and Lift 6 M)
1925 MT Capacity (Span 7 M and Lift 6 M)
193Construction of RCC Scour valve chamber dry type for different type of valves including earthwork excavation, 100mm PCC M15as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as perspecifications and standard drawings and as per direction of Engineer-in-Charge.
194For Class-A loading
195Scour valve chamber of size1.13m x0.85m x1.95mfor connecting pipe size-upto100mm
196Scour valve chamber of size1.175m x0.95m x2.25mfor connecting pipe size-more than 100 mm & upto150mm
197Scour valve chamber of size1.2m x1.08m x2.45mfor connectingpipe size-more than 150 mm & upto200mm
198Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15as leveling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as perspecifications and standard drawings and as directed by Engineer-in-Charge.
199For Class-A loading
200Sluice valve chamber of size1.13m x0.85m x1.27m for pipe size-upto100mm
201Sluice valve chamber of size1.17m x0.95m x1.415mfor pipe size-from 125-to-150mm
202Sluice valve chamber of size1.26m x1.185m x1.82mfor pipe size-from 200-to-300mm
203Sluice valve chamber of size1.39m x1.43m x2.185mfor pipe size-from 350-to-450mm
204Sluice valve chamber of size1.61m x1.75m x2.795mfor pipe size-from 500-to-700mm
205Sluice valve chamber of size 2.07 m x 1.83 m x 3.455 mfor pipe size-from 700-to-1000mm
206Sluice valve chamber of size 2.39 m x 2.05 m x 3.455 mfor pipe size-from 1000-to-1300mm
207For Class-AA loading
208Sluice valve chamber of size 1.13 m x0.85 m x1.325 m-for pipe size-up to 100 mm
209Sluice valve chamber of size 1.17m x 0.95m x1.47mfor pipe size-from 125-to-150mm
210Sluice valve chamber of size 1.26m x1.185m x1.88m for pipe size-from 200-to-300mm
211Sluice valve chamber of size 1.39m x1.43m x2.245mfor pipe size-from 350-to-450mm
212Sluice valve chamber of size 1.61m x1.75m x2.85mfor pipe size-from 500-to-700mm
213Sluice valve chamber of size 2.71m x2.27m x3.455mfor pipe size-from 1300-to-1600mm
214Construction of RCC Sluice valve Junction chamber for different type of valves including earthwork excavation, 100mm PCC M15as leveling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as perspecifications and standard drawings and as directed by Engineer-in-Charge.For Class-A loading
215Junction valve chamber of size 1.8 m x2.1 m x2.0 m-for pipe size-upto 150 mm
216Junction valve chamber of size 2.0 m x 2.2 m x 2.3mfor pipe size-from 150mm -to-300 mm
217Design, construction,testing and commissioning ofRapid Gravity Filter Treatment Plant including all relevant civil, electrical , mechanical ,instrumentation, automization and SCADA works, chemical building and stores along with ancillary civil works as defined in scope of work, technical specification and provisions of CPHEEO manuals for the following sizes .
218At Harma KI Rel Village 174 MLD
2195000 KLH
220for Remaining 2909.0909 KLH
221SITC of Bulk Flow Meter with removable mechanism class \"B\" confirming to ISO:4064:2005/ IS: 2373 of approved make of following dia sized pipelines and specifications complete: Media : Water (Clear ), Temp. 50 deg., Pr. rating: PN16, Protection type: IP- 68, Body Material : IS-210 Gr. FG-200, Accuracy Class :Class B (±2 % @ Nominal flow rate), Magnetic Drive, Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and makingconnection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work.
22280 mm dia
223100 mm dia
224125 mm dia
225150 mm dia
226200 mm dia
227Construction of Village Transfer Chambers Room Type-A
228Construction of Village Transfer Chambers Room Type-B
229Providing, Supplying and fixing of D/F DI Pressure Reducing Valve in pipe line including jointing etc. complete as per standard/ technical specification and direction of Engineer-in-Charge
230150 mm dia
231Dismantling of flexible pavement for pipe line and chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work.
232Bituminous courses
233Granular courses
234Dismantling of cement concrete pavement for pipe line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.
235Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work.
236Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made for trench width more than specified, complete work as per technical specification and scope of work.
237Plain cement concrete pavementof M-30 Grade
238Removing& Re-fixing of Bricks Kharanja road by manual means for laying of pipe line, stacking of serviceable & unserviceable material separately, disposal of dismantled material lead up to 50 mtr. The Bricksinterlockingbe laid on average 12 mm thick bed of mud mortar and the joints to be filled with pointing in cement mortar 1:3. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the direction of Engineer in charge. The rates are inclusive of fixing of80 percent reusable Bricks and cost of required newFirst class FPS bricks (min. 10.5 Mpa) in place of damaged bricks, alllead and lift as per Technical Specifications and direction of Engineer in Charge. Note: If existing bricks used more than 80%, than for every 1% above 80% use, deduction of 1% in cost shall be done for every 1% use above 80%.
239Horizontal aligned Bricks
240provision of Surge Proctection system as per L section and details Techanical specification in the Bid Document including Vetting charge including approval charges
241provision ofCathodic proctection for temporary and permanent arrangement
242Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. Providing M-30 grade concrete by usingcement as per codal provision instead ofM-20 grade design mix.
243Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc.
244Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Thermo-mechanically Treated bars (Conforming of relevent IS code)
245Providing Household Tap Connectionas per technical specification andapproved drawing as per relevant IS code (amended up to date) from HDPE/uPVC/DI/AC/MS/GI pipe line up to consumer meter/premises by using PP mechanical Integrated saddle with inbuilt flow control valve made out of SS316 designed for 5 LPM discharge at 0.5 bar pressure , not exceeding the flow of 7 LPM at 2 bar and a compression elbow, moulded in single piece/ fusion welded (Complete job) including digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance withspecification for potable water including GM Full-way Valve (IS:778 Mark) or wheel valve and specials with 20 mm nominal dia MDPE pipe PE80 PN 16 as per ISO 4427 / 20 mm nominaldia PPR-C (Three layered) pipePN16 SDR 7.4 (IS:15801:2008) (ISI mark) and above ground level using PPR-C pipe with standard PPR fittings/ GI pipes in the premises for fixing a tap / meter box (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level.
246For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr.
247P& F Bib cock (IS : 8931 mark), superior quality of approved make , brss 400 gm, 15 mm nominal bore.
248Road cutting for house hold service connection in minimum trench width whereever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be doneby using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge.
249Add extra over item no 1.21 & 1.22 for providing20 mm PE80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr.
250Providing and laying in position specified grade of reinforcement cement concrete all RCC structural elements upto plinth levelincluding curing compaction finishing with rendering in cement sand mortar 1:3 ( 1 cement : 3 coarse sand) and making good the joints excluding the cost of centering shuttering and reinforcement M20 Grade nominal mix (with graded stone aggregate 20 mm nominal size)For Vertical Post
251Construction of Pump house of RCC framed structure with pump pit in RCC walls as per scope of work and technical specification complete work in all respect including electrical works for indoorand outdoor lighting and fans, rain water drainage, sanitary, plumbing, monorail/ EOT crane etc. complete as per direction of Engineer-in-charge. The GA, structure, electrical, sanitary, P&ID, SLD to be prepared by the contractor and submitted to department for approval for earth quake zone II.
252IPS-1/CPS WTP HARMARA KI REL
253IPS-02 CPS MATA KHERA
254IPS-03CPS RANDIYABADI
255Construction of Pump house of RCC framed structure as per approved standard GA, structure, electrical drawing, scope of work and technical specification complete work in all respect including electrical works for indoorand outdoor lighting and fans, rain water drainage, sanitary, plumbing, monorail/ EOT crane etc for Earth quake zone II and SBC equal to or more than 7 T/sqm.Note: Standard drawings can be viewed on website https://pheddms.rajasthan.gov.in/private/public/dms_document.aspx.
256Type I ( 72.3 Sqm)
257Type II ( 111.34 Sqm)
258Type III ( 150.6 Sqm)
259Type IV ( 212.9 Sqm)
260Type VI ( 407.48 Sqm)
261Supply erection testing and commissioning of pumps & motors of approved duty conditions as perscope of work and specifications given in the tender document.
262IPS-05 CPS GADRIYAWAS Route, 88 LPS/140 m head/(2W+1S) of 200 KW
263CPS-05 PEEND, CPS-06 LINKODA ,BADI SADRI TOWN TP,CPS-07 PANDERA, CPS-08 GUMANPURA, IPS-02/CPS MATA KHERA Route, 293 LPS/160 m head/(6W+3S) of 633 KW
264CSCL-11,13,14 Route, 23 LPS/115 m head/(1W+1S) of 55 KW
265CSCL-7,8,12 Route, 13 LPS/130 m head/(1W+1S) of 37 KW
266CSCL-1,2,4, (4) Route, 18 LPS/65 m head/(1W+1S) of 22 KW
267NCL-8,9,10 Route, 17 LPS/60 m head/(1W+1S) of 22 KW
268NCL-11,24,12 Route, 18 LPS/60 m head/(1W+1S) of 22 KW
269BSCL-3,26 Route, 15 LPS/75 m head/(1W+1S) of 22 KW
270CPS-9,10,11,1,2,13,14 IPS-3 Route, 92 LPS/145 m head/(6W+3S) of 200 KW
271BHCL-10,15,1617,18,19,20 (5) Route, 31 LPS/100 m head/(1W+1S) of 75 KW
272RCL-01,11,12 (4) Route, 18 LPS/70 m head/(1W+1S) of 30 KW
273RCL-03,04,05(4) Route, 16 LPS/65 m head/(1W+1S) of 22 KW
274RCL-09,19,20,21 Route, 15 LPS/70 m head/(1W+1S) of 22 KW
275Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at syncronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected onC.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.
2762.2 KW (3.0 HP)
2773.7 KW (5.0 HP)
2787.5 KW (10 HP)
2799.3 KW (12.5 HP)
28011.0 KW (15 HP)
28115.0 KW (20.0 HP)
28218.5 KW (25.0 HP)
283Providing and fixingat site with necessary packing,Horizontal Centrifugal Split Casting pumps with 4 poleinduction motor operating at syncronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ.
284CSCL-19,20,22,23 Route, 26 LPS/75 m head/(1W+1S) of 37 KW
285CSCL-3,5,6,9,10 Route, 21 LPS/60 m head/(1W+1S) of 30 KW
286CSCL-17,18,21,22,25 Route, 17 LPS/55 m head/(1W+1S) of 18.5 KW
287CPS-01 GOTHRA,CPS-1A NARANI,CPS-02 Bamaniya, CPS-2B Lasrawan,CPS-2C KALYANPURA Route, 166 LPS/65 m head/(1W+1S) of 160 KW
288CPS-3 & CPS-4 Route, 38 LPS/45 m head/(1W+1S) of 37 KW
289NCL-14,15,18,19,20 Route, 26 LPS/60 m head/(1W+1S) of 30 KW
290BSCL-09,10,11,12,13,14(6) Route, 25 LPS/80 m head/(1W+1S) of 45 KW
291BSCL-01,04,05,06 Route, 23 LPS/75 m head/(1W+1S) of 37 KW
292BSCL-08,16 Route, 22 LPS/55 m head/(1W+1S) of 30 KW
293BSCL-20,22,23,24,25,26 (7) Route, 37 LPS/65 m head/(1W+1S) of 45 KW
294BSCL-7,15,18 Route, 23 LPS/50 m head/(1W+1S) of 22 KW
295DG-1,8,12,15,18,26 Route, 43 LPS/67.85 m head/(1W+1S) of 55 KW
296DG-3,4,5,6,16 Route, 22 LPS/67 m head/(1W+1S) of 30 KW
297BCL-01,02,03,11,30 Route, 31 LPS/50 m head/(1W+1S) of 30 KW
298BCL-04,05,06,08,07,09 (7) Route, 30 LPS/60 m head/(1W+1S) of 37 KW
299BCL-26,27,28,29,30 Route, 28 LPS/40 m head/(1W+1S) of 22 KW
300DGCL-09,10,25 Route, 23 LPS/70 m head/(1W+1S) of 30 KW
301DGCL-18,19,20,23,27Route, 35 LPS/45 m head/(1W+1S) of 30 KW
302DGCL-02,11,21,29 (7) Route, 26 LPS/65 m head/(1W+1S) of 37 KW
303DGCL-7,13,14,19 Route, 26 LPS/65 m head/(1W+1S) of 37 KW
304BHCL-17,25,26,27,28 (6) Route, 21 LPS/65 m head/(1W+1S) of 30 KW
305BHCL-01,02,03,04,05,06 (7) Route, 28 LPS/80 m head/(1W+1S) of 45 KW
306BHCL-07,08,09,11 (6) Route, 28 LPS/65 m head/(1W+1S) of 37 KW
307CPS-15 Akola, CPS-16 Raypuriya Route, 97 LPS/55 m head/(1W+1S) of 90 KW
308CPS-17 Tara Khedi, IPS-4Route, 85 LPS/70 m head/(2W+1S) of 90 KW
309KPCL-07,11,17,26,28 (6) Route, 28 LPS/50 m head/(1W+1S) of 30 KW
310KPCL-04,12,13,14,15(6) Route, 34 LPS/75 m head/(1W+1S) of 55 KW
311KPCL-01,02,03,05,09 (7) Route, 38 LPS/45 m head/(1W+1S) of 37 KW
312Cps-18 & 19 Route, 70 LPS/55 m head/(1W+1S) of 75 KW
313RCL-14,15,18,25,27 (7) Route, 28 LPS/60 m head/(1W+1S) of 37 KW
314RCL-22,23,24,26,28 (6) Route, 27 LPS/65 m head/(1W+1S) of 37 KW
315SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) , Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304, Electrode : SS AISI 316L / Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart, Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection with existing pipeline including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work.
316EFM100 mm
317EFM 150 mm
318EFM 200 mm
319EFM 250 mm
320EFM 300 mm
321EFM 400 mm
322700 mm
323800 mm
3241000 mm
3251200 mm
326Providing, lowering, aligning & fixing in position DI D/F Plunger Type Flow Control Valve of approved make of following Pressure rating & dia complete and of following specifications:Body-Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or EN-JS 1030,Plunger/ Piston - Stainless steel AISI- 304/ Gr 1.4301, Piston Guides- Bronze Welded Overlay / SS Shaft/Crank/Spindle- Stainless steel AISI- 410/ Gr 1.4021Body Seat Ring- Stainless steel AISI- 316/304/ Bronze IS:318- LTB2 ,Seal ( O- ring / Quad ring)- EPDM/ NBR, Bearing Bush - Bronze IS:318- LTB2,Slotted cylinder / Strainer / Diffuser- AISI- 420/ 304,Nut- Bolts - SS, Face to Face- as per ANSI B 16.1/ EN 558-1 and Flange ends should be as per ANSI B-16.5, Class 150 and Class 300/ EN-1092-2.Insertion rubber of black EPDM 6mm thick ,Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied bothinside and outside . Suitablesupport structure as per directions of EIC including jointing & jointing material,labour, testing and commissioning as per Technical Specification & as per direction of Engineer-In- Charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
327Plunger Type Flow Control Valve
328100mm dia
329200mm dia
330250mm dia
331Construction of Flow Meter Chamber in required size and shape as per drawing including required excavation of earth in all types of soil such as murrum, sand, sandy silt, black cotton soil, hard soil, kankar and all types of rocks etc.,disposing of surplus excavated material within a lead of 50 meters. The work includes laying of 100 mm thick plain cement concrete 1:4:8(1 cement : 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) in bedding and foundation, construction of 150 mm thick RCC walls in M-20 grade C.C., covering it with class -A loading ferro cement covers of required sizes and complete with removal of excess material and making clean the site upto the satisfaction of Engineer in charge
332Design & Construction ofclear water Reservoirs of required capacity at following places, including its piping, fittings, etc complete in all respect as per the scope of work & specifications given in tender document
333WTP/IPS-01 CPS Harmara ki rel
334IPS-05 CPS GADRIYAWAS
335IPS-02 CPS MATA KHERA
336IPS-03 CPS Randiyardi
337CPS-1 BARWALA DEWAL
338CPS-07 PANDERA
339CPS-09 BHATOLI GUJRAN
340CPS-10 AKOLA KHURD
341CPS-15 Akola
342CPS-16 Raypuriya
343CPS-17 Tara Khedi
344CPS-18 Gokulpura
345IPS-06/CPS BAMANIYA
346IPS-04/CPS BHIMAGARH
347Construction of RCC (Dome type) Clear Water Reservoir of following capacity as per Scope of work and Technical specification, consisting of the following main activities: -
348a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. .b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase.c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall.e) Successful hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the roof Slab.g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure.
349h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type).i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide.k)Providing and fixing of 150mm wide water bar for the construction joints in the container.l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir.m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.
350Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2 & 3.
351CPS -02 NARANI
352CPS-3 Lasrawan
353CPS-4 KALYANPURA
354CPS-05 LINKODA
355CPS-06 Peend
356CPS-8 GUMANPURA
357CPS-11 MANDHIYA
358CPS-12 NARDHARI
359CPS - 13 BHADSODA
360CPS-14 Jawanpura
361CPS-19 Gurjaniya
362Construction and commissioning of RCC flat slab Over Head Service Reservoir of following capacity and staging including all material and labour charges as per the Scope of work and Technical Specification, consisting of the following main activities: -
363a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc.c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil.d) Providing and applying two coats of food grade epoxy paint on the inside surface roof slab, and 600 mm height of the vertical wall.e) Successfully hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the top surface of the roof slab.g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc.h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top Slab to bottom Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony and MS ladder with safety cage from balcony to top slab.
364j) Providing and fixing water level indicator (float type).k) Providing and fixing of hand railing all around the balcony, roof and staircase, consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres.l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide.m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall).n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground.o) Lighting arrestor consisting of providing and fixing of 2 Nos.of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mmp) CI/DI puddle collar shall be fixed in the bottom/slab for connecting inlet, outlet, overflow and washout pipe of the reservoir.q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work.r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.
365Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 15 M
36650 KL, staging Height 15 m (1-Nos.)
367Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: -
368a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc.c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR.The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil.d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall.e)Conducting successfully hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome.g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc..h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab.j) Providing and fixing water level indicator (float type).
369k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres.l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide.m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall).n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground.o) Lighting arrestor consisting of providing and fixing of 2 Nos.of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm.p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir.q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work.r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately.
370Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II18 M Staging
371100 KL, staging Height 18 m
372150 KL, staging Height 18 m
373200 KL, staging Height 18 m
374250 KL, staging Height 18 m
375300 KL, staging Height 18 m
376Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II20 M Staging
377100 KL, staging Height 20 m
378150 KL, staging Height 20 m
379200 KL, staging Height 20 m
380250 KL, staging Height 20 m
381Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II22 M Staging
382100 KL, staging Height 22 m
383150 KL, staging Height 22 m
384200 KL, staging Height 22 m
385250 KL, staging Height 22 m
386300 KL, staging Height 22 m
387Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 24 M
388100 KL, staging Height 24 m
389150 KL, staging Height 24 m
390200 KL, staging Height 24 m
391250 KL, staging Height 24 m
392Construction of RCC Dome type Ground Level Service Reservoir (GLSR) of following capacity as per the Scope of work and Technical specifications, consisting of the following main activities: -
393a)Topographicsurvey,preparationofsitecontourplan,conductingSBCtest andits approvalfromdepartment beforeconstruction.Submissionandapprovalofconcretemix design and water quality test report for water to be used in construction.b) Excavation in all types of soil, PCC below foundation & all RCC Work.c) All the GLSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall giving.e) Successful hydro test and water tightness test as per I.S. code.f) Providing and applying three coats of anti-carbonation paint on the roof Slab.g)Providingandapplyingthreecoatsofcement-basedpaintontheremainingexternal surface area of the structure.h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder fromtopbottomSlabinsidecontainer.Providingandfixingwaterlevelindicator(Float type).
394i) Providing and fixing MS ladder from ground to top slab with safety cage.j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide.k) Providing and fixing of 150mm wide water bar for the construction joints in the container.l)ProvidingandfixingCI/DIpuddlecollarstheverticalwallforconnectinginlet,outlet, overflow and washout pipe of the reservoir.m)Inlet,outlet,overflow,washoutpipesandvalvesarenotincludedinthiswork, provision for the same shall be taken separately.
395Rates for RCC GROUND LEVEL SERVICE RESERVOIR SEISMIC ZONE-II & III andSBC18T/sqm
39650 KL capacity
397100 KL capacity
398150 KL capacity
399200 KL capacity
400Providing and fixing of flanged/ plain ended MS special of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depth in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge.
401MS pipespecialsup to600mmdia (withminimum5mmthickness sheet)
402Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing, scope of work and technical specifications complete work in all respect. Brief details of boundary wall parameter is as below:1. Depth of foundation- 900 mm.2. PCC in M-10, width -900 mm and thickness 100 mm,3. Stone masonary in CM: 1:6 section of foundation above PCC,600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D) 4. Superstructure work: Stone masonary in CM: 1:6, W-300, height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm.5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6.6. Expansion joint shall be on every 30 mtr.7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall be provided.8. Pillar for main gate 350x350 mm in size is part of boundary wall.9. Cement paint of approved colour in 3 coat shall be done.
403Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamal paints.
404Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 Mtr. in width as well as 10 Sqm on plan including disposal of excavated earth upto 50 Mtr. and lift upto 1.5 Mtr. disposed soil to be levelled and neatly dressed : All Kind of spoil
405Supply of dry manure including loading unloading transportation & stacking at site :
406Goat dungmanure.
407Supply of different varities of tree/ shrubs/ climbers according to height and age of the plant at site including loading/ unloading & transportation etc. complete :
408Different varities of Climber 900 mm to 1500 mm
409Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils
410Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.
411M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size).
412Providing and fixing up to floor five level pre cast cement concrete string or lacing courses, copings, bed plates, anchor blocks, windows sills, shelves, louvers steps, staircases, etc. including carriage, hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand) cost of required centering, shuttering and finishing smooth with 6 mm thick cement plaster 1:3 (1 cement : 3 fine sand) on exposed surface, including all T & P, curing etc. complete:M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size).
413Supply and erection of M S swaged tubular pole conforming to IS: 2713-1980 (part I to II) with galvanised base plate in position including excavation of the pit and filling the same with C.C. of M-20 grade (1:1.5:3) from base plate to 50 cm above ground level, with the help of steel frame not less than 40 cm dia up to 114.3mm outerdia and 50 cm beyond 114.3mm outer dia around the pole. Duly finished with cement plaster, earthing terminals, cable entry, GI cable sleeve complete as required. After eraction pole shall bepainted with two coat of red oxide primer and two quote of enamel paint of silver colour as per the direction of Engineer incharge.The pole shall be fabricated by using ISI mark tube for structural purpose of following height & designation. ( See Table P - 02 for specs. ) complete in all respect. All as per pre approved byEngineer in charge. For additional technical parameters of products/work , refer Annexure \"A\" attached with this BSR 7.5 mt high
414Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) andsecondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS Rnumber with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <1000mA shown in LM79 report. The luminaire shall be BIS certified and T.C. certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened ,color Rendering Index >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report withliable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additionaltechnical parameters of products/ work , refer Annexure \"A\"attached with this BSRLED Street Light fixture 45 Watt
415Providing and laying XLPE/PVC insulated & PVC sheathed Unarmoured control cables of 1.1 KV grade with copper conductor as per IS 1255 including excavationj of 30 CmX75 Cm size trench 25 Cm thick under layer of sand and Iind class bricks covering4C x 2.5 sq.mm
416Providing and fixing cow catcher made of R.S. joist angles channels MS rounds including cutting welding and fabrication with priming coat of red oxide (as per design).
417Construction of Soakage well in all types of soil 300mm thick dry stone masonry, top and bottom 300 mm course in CM 1 : 6, 80 mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C. flooring earthwork complete as per approved drawing including disposal of earth within a lead of 50 Mtr.
418Size 300 cm dia outside & 300 cm depth
419Construction of Septic Tank in all types of soil with 40 Cm. thick masonry in CM 1 : 6, 15 Cm. thickC.C. bed of 1 : 5 : 10, M-15 grade C.C. flooring & over stone slab covering, 80 mm thick slab, jointing of slab in CM 1 : 3 Ralthal, Kharanja, 50 mm thick stone partition walls, 20 mm thick plaster in CM 1: 6 finished with neat floating cement, 4 Nos C.I. foot rests of approved design, two No. 450 mm dia 25Kg. of each C.I. cover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 Mtr.
420Size 400 x140x150 cm.(for 50 users)with 115 mm thick RCC (M-20) slab with Tor steel reinforcement 10mm ϕ @15 cm c/c bothways including shuttering complete in all respect.
421Providing Laying & Jointing glazed S.W. pipes grade \"A\" (IS : 651 Marked) of approved make with spun yarn & stiff mixture of cement mortar 1:1 excavation & refilling of earth in all types of soil upto 1.2 m. depth, S.W. fittings, including testing of joints etc. complete.
422150mm dia
423Providing and Laying C.C. 1 : 5 :10 (stone aggregate 40 mm nominal size) all around S.W. pipe including 15 cm. thick bed concrete as per Rajasthan PWD specifications : (Width W = Diameter of pipe in Cm + 40 Cm.). (Excluding cost of pipe )
424150mm dia
425Providing and fixing G.I. pipes (External Work) with G.I. fittings (IS : 1239 Mark) including trenching & refilling earth etc.
42625mm dia nominal bore
427Providing and fixing Ball Cock (IS : 1703 Mark) with Rod & P.V.C. Ball complete.
428Brasswt.Not less than 1000 gm 40mm.:
429Laying of lawns including ploughing leveling breaking of clods manuring and removal of stones etc. (cost of manure or extra good earth to be paid separately )maintenance of lawn foe 30 days or more till the grass forms a thick lawns free from weeds and fit for moving in the duration of planting if lawn die some where the contractor will replant it at his own cost
430in rows 5 cm apart in either direction
431Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils
432Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion)
433Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.
434M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size).
435Providing and laying damp-proof course with cement concrete grade M-150 (1 : 2 : 4) mortar prepared with 1% solution of water-proof compound complete as per specification .
43675mm thick.
437Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.M20 grade Nominal Mix / Design Mix
438Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix
439Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :
440Columns, pillars, posts and struts etc.
441Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc.
442Brick masonry with F.P.S. bricks of class designation 75 infoundation and plinth with bricks
443Cement mortar 1 : 6 (1 cement : 6 coarse sand)
444Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in :
445Cement mortar 1 : 6 (1 cement : 6 coarse sand)
446Half brick masonry in foundation & plinth using bricks of designation 75
447Cement mortar 1 : 4 (1 cement : 4 coarse sand)
448Half brick masonry in Superstructure , above plinth level upto floor Vlevelusing bricks of designation 75
449Cement mortar 1 : 4 (1 cement : 4 coarse sand)
450Brick work in partition in super structure upto five storey 7cm. thick (brick on edges) using bricks of class designation 75 in :
451Cement mortar 1 : 4 (1 cement : 4 coarse sand)
452Steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m)fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete.Hot finished seamless type tubes.
453Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :
454Windows side hung /Ventilators top or centre hung (openable)
455Partly fixed and partly openable [ fixed area not to exceed 33%]
456Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance.
457Providing and fixing Square bars or other flat welded to window, ventilatiors etc.
458Brick on edge flooring with bricks of class designation 75 including cement slurry& pointing in CM (1 : 3) etc. complete laid on20 mm thick bed of : Cement Sand Mortar 1 : 6
459P & F 1st qualityHeavy Duty Vitrified Polished Digital tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. Size 600mm x 600mm
460Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish :
46120mm thick .
462Distempering with dry distemper of approved brand and shade (two or more coats) and of required shade on new work, over and including, priming coat of whiting to give an even shade including all scaffolding.
463Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade :
464Two or more coats on new work including preparation of base with primer, putty, lippy complete in all respect.
465Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : Two or more coats on new work
466Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure \"A\" :30mm tick- commercial Veneer Both side
467Providing and fixing in cement sand mortar 1 : 4 single paitam (rebated) stone doors windows and ventilator frames of approved quarry : Size 100 x 75mm.
468Providing and fixing factory made P.V.C. door frameof the size 50x47mm with a wall thickness of5mm, made out of extruded 5mm PVC foam sheet mitred at two corners and jointed with 2 Nos. of 150mm long brackets of 15x15mm M.S. square tube. The two vertical door profiles are to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame shall be fixed to the wall using 65/100 mm long M.S. Screws through the frame by using PVC fasteners. A minimum of 4 nos of screw to be provided for each vertical member and minimum 2 nos for horizontal member etc. complete as per manufactures specification and direction of Engineer in Charge.
46930mm thick factory made solid both side Pre laminated panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles and 15x15mmtop & bottom rails. M.S .frame shall have a coat of steel primers of approved make and manufacture M.S. frame covered with 5mm thick heat moulded PVC ‘C channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45 degree angle on either side forming stiles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75 mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2) thick, 20mm wide cross PVC sheet shall be provided as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with 7mm (5mm +2mm) thick x 15mm wide PVC sheet bending on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacture’s specification & drawing.(For W.C.and bathroom door shutter).
470Supplying and fixing in walls machine cut and polished stone shelves, tands andin CM 1:3 with machine cut edges :
471Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it\"s ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter-53, 54 & 56 for additional technical parameters of product / work refer Annexure \"A\" attached with this BSR
472(A) Short point (up to 3.0 mtr.)
473(C)Long point (up to 10 mtr.)
474Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it\"s ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter-53, 54 & 56. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR
475On Board
476Providing and fixing of power plug point with non modular accessories as per PWD specification for electrical Works with Galvanized box of 1.2 mm thick with earth terminal with suitable size phenolic laminated sheet (IS : 2036 - 1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outlet making connection , testing , etc. as required. For specification of Wiring accessories refer Chapter-56 related item & For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR
477Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR
478(A) 2x1.5 sq.mm
479(B) 2x2.5 Sqmm +1x1.5sqmm
480(C) 2x4.0 sqmm+1x2.5 sqmm
481Supply & Laying following size\" B \" class , G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor/ strip / cable in ground/ surface/ recess as required. All as per pre approved by Engineer in-charge. (Earth Excavation will be Paid Extra)All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annex ure \"A\" attached with this BSR.32mm dia
482Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. \"B\" class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in-charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .
483Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <1000mA shown in LM79 report. The luminaire shall be BIS certified and T.C. certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened, color Rendering Index >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Compliant. All as per pre approved by Engineer in-charge.
484LED Street Light fixture 30 Watt
485Supply & drawing Wiring for sub mains ISI marked (IS:694) 1100 Volts grade PVC insulated flat twin core sheathed solid aluminium conductor with 10 SWG G.I. Support wire duly clipped etc. as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR6.0 Sq.mm
486P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR
487P & F 3.0 mm thick Poly propelene plastic polished concealed fan box, squre of size (106x106) mm dia, depth 50 mm , 10 mm dia rod of MS with chrome plated with 55 mm length extended on each side . All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR
488Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSRMCB 6 A to 32 A rating
489S&F following sizes of ISI marked ( IS:14927 P - II ) virgin material UPVC trunking along with accessories like coupler, inner, outer, elbow, square box, tee, end cap etc. on surface with screws, expansion fasteners as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR25mmx12mm
490S&F following sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit with wall thickness according to IS Specified along with ISI marked (IS:14768 P-II 2003) accessories in recessed using saddles, clamps, fasteners, pvc bushes, check nuts, as required including cutting jhiris in the wall and making good the same as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR 25mm
491Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR.300 mm sweep(900/1400 RPM)
492Providing & Fixing of ISO certified company made TP&N 415 V AC-23A front handle operated switch disconnector fuse unit, cubical type, with metallic enclosure, as per PWD specification for electrical Works conforming to IS/lEC 60947-3 : 1999 with HBC fuses including making connections with lugs, testing etc as required. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR100/125 A rating
493SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% ICU. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR160 Amp , 25 kA, adjustable O/L & adjustable S/C setting.
494Providing & Fixing of ISO certified company made bus bar chamber housed in sheet metal box as per PWD specification for electrical Works Confirming to IEC-60439/IS-8623 & IEC-60529/IS-2147 made out from 1.6 mm thick powder coated CRCA sheet,degree of protection IP-31, front openable bus bar made out of aluminium or wrought aluminium alloy suitable for 100 amp. Capacity , bus bar fixed on porcelain/DMC insulators at approved spacing including making connections etc. as required. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR.450 mm long , 4 strip
495Brick masonry with F.P.S. bricks of class designation 75 infoundation and plinth with bricks
496Cement mortar 1 : 6 (1 cement : 6 coarse sand)
497Brick work in partition in super structure upto five storey 7cm. thick (brick on edges) using bricks of class designation 75 in :
498Cement mortar 1 : 4 (1 cement : 4 coarse sand)
499Supplying and fixing rolling shutters of approved make, made of 80 x 1.25mm. M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including cost of spring hooks, providing and fixing necessary 25.3cm. long wire springs grade No. 2 and M.S. top cover 1.25mm thick for rolling shutters as per design. (Clear openable area to be measured for payment).
500Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :
501Partly fixed and partly openable [ fixed area not to exceed 33%]
502Providing and fixing 50mm thick cement concreteflooring with Metallic concrete hardener topping, under layer of 38mm thick cement concrete 1:2:4 (1-cement : 2-coarse sand : 4-graded stone aggregate 20mm thick nominal size) and top layer of 12mm thick metallic concrete hardener consisting of mix 1:2 (1 cement : 2 stone aggregate, 6mm nominal size) by volume & mixed with metallic hardening compound of approved quality @ 2Kg./Sqm including cement slurry, rounding off edges etc. but excluding the cost of nosing of step etc. complete.
503Cement plaster in skirting and/dado18 mm thick with cement mortar 1:3 (1 cement : 3 course sand) finished with a floating coat of neat cement including rounding of junctions with floor .
504Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish :
50520mm thick .
506Colour washing of all shades to give an even shade including all scaffolding :
507New work (two or more coats) with a base coat of white washing with lime.
508Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including Prepration of base and all scaffolding :
509New work (two or more coats) over and including scrapping and priming coat with cement primer.
510Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : Two or more coats on new work
511Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) ofapproved make in surface / recessed ISI marked( IS:9537 P - II ) rigid steel conduit & it\"s accessories, round tiles,18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in switch board& false ceiling point,6 A switch, 3.0 mm thick ISI markedphenolic laminated sheet, pvc bushes, check nuts, zinc plated / brassscrews, cup washers, making connections, testing etc. as required.
512Medium point (up to 6 mtr.)
513S&F following sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit with wall thickness according to IS Specified along with ISI marked (IS:14768 P-II 2003) accessories in recessed using saddles, clamps, fasteners, pvc bushes, check nuts, as required including cutting jhiris in the wall and making good the same as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR40 mm
514Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor ISI marked (IS:694) of 1.1 kV grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required.
5152 x 6.0 sq. mm. + 1 x 2.5 sq. mm.
516Providing & Fixing of Wiring Accessories OEM fabricated following size GI box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .10-12 Module
517Providing & Fixing of ISO certified company made TP&N 415 V AC-23A front handle operated switch disconnector fuse unit, cubical type, with metallic enclosure, as per PWD specification for electrical Works conforming to IS/lEC 60947-3 : 1999 with HBC fuses including making connections with lugs, testing etc as required. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR63 A rating
518Supply and fixing of 1.6 mm thick MS 11 kV Danger plates as per IS :2551-1982 & specification of Discom on the existing poles complete in all respectas per PWD / DISCOM specification. All as per pre-approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR
519P & F ISI marked (IS:3854) 6 amp. flush type non modular switch with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .
520Providing & Fixing of 6 amp. Combined flush type non modular socket and switch set as per PWD specification for electrical Works,made out from industrial grade Polycarbonate or fire resistant ABS material including cutting hole in tile and making connection testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .
521Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / Sqaure SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSRRecessed Mounting 18/20W
522P & F of IP65 IK10 rated LED bulk head type light fixture made from CRCA sheet steel housing suitable for mounting LED tube system (integral driver), Power consumption of 10-15W , 500-600 lumens system lumen efficiency 70 lm/ watt output suitable for1x100 W GLS/9W CFL bulk head fixtures, life time of 50000 burning hours with 70% initial lumen maintained. CCT 3000° K,4000° K and 6000° K. Fixture shall be incompliance with CE & KEMA standards.LED BULK head luminaire 9/10 W
523Earth work in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods watering, rolling each layer with 1/2 tonne roller, or stone or steel rammers androlling every 3rd and top- most layer with power roller of minimum 8-10 tonne capacity and dressing up in embankment for roads, flood banks marginal banks and guide banks or filling up ground depressions, lead up to 50 Mtr. and lift up to 1.5 Mtr.:All kinds of soil
524upto 1.5 mtrs
525Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size).
526Providing & fabricating steel reinforcement for R.C.C. work including cutting, bending, palcing in position and binding complete including cost of binding wire in foundations, Raft footing step Beams base of column etc. upto plinth level. Hot rolles deformed (IS:1139)cold twisted (IS:1786) bars.
527Cleaning grass and removal of rubbish up to a distance of 50 mtr. out side the periphey of the area cleared
528Excavation work by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains not exceeding 1.5 mtr. In width or 10 cum of plan including dressing of siees and ramming of bottoms , lfit up to 1.5 mtr. Including taking out the excavated soil surplus excavated soil as directed with in a lead of 50 mtr. including stacking of useful material if available ordinary rock
529Providing and laying in position cement concrete including curing compaction etc . Completein specified grade excluding the cost of centering and shuttering. All work up to plinth level using crusher broken aggregate All work up toplinth level 1:4:8 (1 cement :4 coarse sand : 8 graded stone aggregated 40mm nominal size)
530Random rubble stone masonry for foundation and plinth in cement sand mortar above 30 cm thick wall in: cement sand mortar 1:6 (1 cement : 6sand)
531Honey comb brick work half brick thick with bricks of class designation 75 up to third storey in.Cement mortar 1:6 ( 1 cement : 6 coarse sand )
532Brick work with mechanised autoclaved flyash lime bricks conforming to IS: 12894 :2002 of class designation 100 in superstructure above plinth level upto floor V level in.Cement mortar 1 : 6 (1 cement : 6 coarse sand)
533Providing and fabricating reinforcement for RCC work including straightening, cutting, bending, placing in position in binding (including cost of binding wire ) all complete up to floor three levelCold twisted deformed bars (IS:1786)
534Supplying and fixing stone lintels/bed plates of approved quarry rough dressed in cement mortar 1:4 (A) up to 15 cm thick
535Supplying and fixing in walls machine cut and polished stone shelves, tands, in 1:3 with machine cut edges
536Kota stone minimum 30mm thick.
537Grading roof water proofing treatment with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) with water proof compound as per manufature specification
538Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
539Providing&fixingprecastcementconcretecoping1:2:4mix50mmthickcompleteas per specification :
540Structural steel work riveted or bolted in built up sections, trusses and framed work, including cutting hoisting fixing in position and applying a priming coat of approved steel primer all complete above plinth level upto 4.5 mtr height In flates, tees, angles & Channals
541Providing and fixing in position collapsible steel shutters with vertical M.S. , Channels 20x10x2mm and bracket with flat iron diagonals 20x5mm, size with top and bottom rail of T-iron 40x40x6mm . with top flat of 50 x 10 mm and bottom flat of 40 x 6 with 40mm dia steel pulleys/ ball bearing complete with bolts, nuts locking arrangements inside and outside stoppers, handles etc. as per specification including applying a priming coat of approved steel primer ( To be measured and paid as per outer dimension).
542Supply and fixing door, window, chowkhats and other frame including antitermite treatment MS flat old faste of size 250x40x3mm mixed with MS bolt 5mm dia 50mm long duly embedded in cement concrete M-15 grade (Klin seesoned and chemically treated Hollock wood Grade-1
543Providing and fixing external grade board solid core flush door shutter ISI 2202-67 marked using phenol formal dehyderesin in glue both sides with approved steel fitting complete as per annexure A 30 mm thick
544B) Decorative teak veneer both side
545Add extra for RR stone masonary with hard stone in square or Rectangular pillars Up to 45cm length and all sides are free
546Providing and fixing vertical blinds, made out of non woven polyster fabric 85 to 90 mm wide of approved shade & design with power coated aluminium channel minimum 1\"x1\" system including cording set etc. complete as per specification & directon of engineer in charge
547Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately).Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer)
548Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/neoprene gasket etc. complete as per the architecyutal drawing and the direction of engineer-in-charge (cowst of aluminum snap beading shall be paid in basic item) with glass panes of 4.0 mm thick (weight not less than 10 kg /sqm) as per IS 2835
549Providing and fixing expanded grill made of anodised aluminium as per design and drawing having members section of7.5 mm x 6.0 mm and opening of size 102 mm x 99 mm to aluminum window/vent with required screws. Y and H aluminum sec ( as per drawing) at the ends and middle joints respectively complete in all respect as per direction of Engineer-in-charge.Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer)
550Providing and fixing IS : 3564 marked Aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc. complete.
551P&F bright finished mortic lock of approved made Godrej or equilent with pair of CP handles for doors with necessary screws etc. complete (Best make of approved quality) as per direction of Engineer in charge
552Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S. With brass cover plate
553Random rubble stone kharanja under floor
554Plaster on new surface on wall in cement sand mortar 1:6 including raking of joints etc. complete fine finbished
555(A) 20mm thick
556(B) 12mm thick
5576mm thick cement plaster on ceiling of mix 1:3( 1 cement : 3 fine sand)
558Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete
559Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to code IS : 15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar).
560Providing and fixing Ist quality MAT finished ceremic tiles size 300 x 300 mm confirming to IS: 13755 & IS: 15622 colour such as white, grey, Ivory, fume red brown in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry including nicely finished joints using water proof joint filler powder and finishing with flush pointing in white cement mixed with pigment to match the shade of tile complete (including the cost of cement mortar bed 1:4).
561Applying priming coat with ready mix pink oir gray primer of approved brand and manufacture on wlld work hard and soft wood
562Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work
563Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding : New work(Two or more coats) over and incluiding scrapping and priming coat with cement primer
564Finishing wall with water proffing cement paint of approved brand and manufacture and or required shade to give an even shade including all scaffolding New work (two or more coat applied @ 3.84 kg/10 sqm)
565Making of drip course(Tapka) in cement sand mortar 1:6 width up to 40mm and 10mm thick as per approved design
566Earth work in excavation /by mechanical means(hydraulic excavator)/manual means over areas (exceeding 30 cm in depth 1.5 mtr. In width as well as 10 sum on plan) including disposal of excavated earth lead up to 50 mtr. And lift up to 1.5 mtr. Disposed earth to be levelled and neatly dressed :ordinary rock
567P&F curtain rods of 1.25mm thick chromim platged brass plate, with two chromim plated brass brackets fixed with C.P. brass screws and wooden plugs etc. whereover necessary complete 20mm
568P&F indian type white glazed vitreous china ist quality WC orissa pan (IS 2556 Mark) with 100mm vitreous china P or S trap including cutting and making good the wall and floor size 580x440 mm
569P&F WVC wash basin (Ist quality IS:2556 Mark) of approved make with C.I.Brackets duly painted 1 No. 15mm CP Pillar cock (IS 8934 Mark) and 32mm CP brass waste coupling of approved make, 25mm GI waste pipe complete including cutting and making good the wall size 580mmx450mm
570P&F Towel Rall or Ring of approved quality/make CP brass Town pail with brackets 600x20mm
571P&F PVC storage Tank (IS :12701 marked including the BIS license No.) of approved make with cover 25mm dia 1 M long GI over flow pipe and 25 cm. long wash cut pipe with plug & socket, including making connection etc. complete of approved design
572(A) 1000 Litre capacity
573(B) 500 Litre capacity
574P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thick commercial ply base fixed to wooden screws & washers.Size 600 x 450 mm x 4 mm thick
575P&F GI Pipe (internal work) with GI fitting (IS 1239 Mark) and MS clamps including cutting and making good the walls and floors Exposed on wallsSize 600 x 450 mm x 4 mm thick
576(A) 15mm dia nominal bore \"B\" Class
577(B) 25mm dia nominal bore \"B\" Class
578P&F GI pipe (External works) with GI fitting (IS 1239 mark) including trenching & refilling earth etc.
579(A) 15mm dia nominal bore \"B\" Class
580(B) 25mm dia nominal bore \"B\" Class
581Making connection of GI distribution branch with GI main including all fittingup to 25mm dia
582P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make:
583(A) CP Brass Bib cock 15mm nominalbore
584(B) CP Brass Bib cock 15mm nominal bore long body 15mm nominal bore weight not less than 690 gram
585P&F stop cock (IS 8931 mark) superior quality of approved make Brass 400 gram 15mm nominal bore
586P&F Ball cock (IS 1703 Mark) with Rod and PVC Ball complete Brass wt. Not less than 300 gm,15mm.
587P&F full way valve (IS 778 Mark) or wheel valve of approved make
588(A) Gun metal 15mm nominal bore
589(B) Gun metal 25mm nominal bore
590P&F sand cast floor Trap (Nahni) of (IS 1729 mark) of approved quality/make with socket down or hinged grating includinbg good the floor Size 100x100mm
591P&F Flush Cock/Flush Valve (IS 9758 mark) for wC of approved quality make
592(A) Brass /Gun metal Half-turn weight 1 kg of approved quality /make 25mm nominal bore
593Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead.Depth up to 0.5 m
594Construction of soakage well in all type of soil with 300mm thick dry masonary top and bottom 300mm course in CM 1:6 , 80mm thick stone slab, jointing of slab in CM 1:3 Ralthal, kharanja 40mm thick M-15 grade C.C.flooring earth work complete as per approved drawing including disposal of earth with in a lead of 50 mtr. Size 240 cm dia outside and 240 cm depth
595Construction of septic tank in all types of soil with 40 cm thick masonary in CM 1:6,15 cm thick C.C.bed of 1:5:10, M-15 grade C.C.flooring & over stone slab covering, 80mm thick slab jointing of slab in CM 1:3 Ralthal, kharanja, 50mm thick stone partition wall, 20mm thick plaster in CM 1:6 finished with neat floating cement 4 Nosa. CI foot rests of approved design two Nos. 450mm dia each Ferro cement cover with frame. earth work etc. with in a lead of 50 mtr.
596(A) size 230x110x150 cm (for 20 users)
597Providing and laying cement concrete 1:5:10 (Stone aggregate 40mm nominal size) up to haunches of S.W.pipes including 150mm thick bed concrete (Width W= Dia of pipe in CM+30 cm) concrete width to be reduced from width W at Centre of pipe to \"0\" at top of pipe (Excluding cost of pipe) 100mm diameter SW pipe
598Construction of chamber in all type of soil with 300mm thick masonary in CM 1:6 m 10 cm thick C.C. 1:5:10 in foundation, 20mm thick inside plaster in CM 1:6 finished with floating neat cement 50mm thick M-15 grade C.C.flooring, Ferro work etc. complete as per design including disposal of surplus earth with in a lead of 50 mtr.
599(A) Inside size 300x300 mm depth up to 0.5 Cement cover with frame.
600P&F rigid pvc pipe (IS 4985 mark) class II (4 kg/cm2 ) approved quality,make including jointing the pipe with solvent cement rubber ring and lubricant
601(A) 110mm dia
602P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant:110mm dia
603(A) Door bend (Top side)
604(B) Bend 87.50
605(C) Vent Cowel
606P&F 15mm dia connection pipe of approved quality /make
607(A) PVc Pipe with CP Brass nuts up to length 450mm
608Supply and fixing GI Union ISI marked in GI Pipe line as required complete in all respect of size
609(A) 15mm dia nominal bore
610(B) 25mm dia nominal bore
611P&F Grating of approved quality/make stainless steel sheet size 125mm dia
612P&F Ist quality WVC Urinal (IS 2556 mark) with 25mm dia GI waste pipe dome waste coupling connected iron brackets or screws etc. complete Flat Back (small) size 456x355x265 mm
613P&F MarbleUrinal partition slab both sides polished of approved design cut form marble size 900x600mm Makrana \"Albeta\" Marble having light streaks
614P&F European type white glazed vitreous china Ist quality Double syphonic WC (IS 2556 mark) with P orf S trap including cutting sna making good the wall and floor
615P & F Low level Flushing Cistern of 10 litres capacith (IS : 2556 mark), of approve make with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS : 1703 mark) complete including cutting and making good the wall: PVC bend of make commander champion PVC with PVC bend as per IS 7231
616P &F Kitchen & Lab. Sink of approved make with C.I. bracketsduly painted 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor.WVC Lab sink (IS: 2556 mark) size 530 x 430 x 180mm
617P&F jet spray for water closet with CP copper tube flange of approved make
618Wiring of light point/fan point/exhaust fam point bell point with 1.5 sq mm nominal size SR PVC insulated unsheathed 1.1 kv grade fixible copper conductor and 1.5 sq mm nominal size FR PVC isulate copper earth conductor (IS : 694) of approved make double lock/ISI marked single lock pvc casing copping & its assessories 18 SWG MS box wikth earth terminal screwless cage connector for neutral looping in switch vboaed & falce ceiling point 6 A switch 6 A socket ,3.0 mm thick phenolic laminated sheet zinc plated/brass screws, cup washers making connection testing etc. as required
619(A) Short point (up to 3.0 mtr.)
620Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A or C ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing cappingincluding all as per pre approved by Engineer in charge,making connections, etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additionaltechnical parameters of products/ work , refer Annexure \"A\" attached with this BSR .
621(A) 2x1.5 sq.mm
622(B) 2x2.5 Sqmm +1x1.5sqmm
623(C) 2x4.0 sqmm+1x2.5 sqmm
624Providing & Fixing of ding dong/musical chime bell as per PWD specification for electrical Works, including making connection testing etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR
625Supply & Laying following size\" B \" class , G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor/ strip / cable in ground/ surface/ recess as required. All as per pre approved by Engineer in-charge. (Earth Excavation will be Paid Extra)All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annex ure \"A\" attached with this BSR32mm dia
626Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR
627Plate Earthing as per PWD specification for electrical Works as perIS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia.G.I. \"B\" class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/work , refer Annexure \"A\" attached with this BSR
628Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material , toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz±3%, Power Factor >0.95 ,driver Efficiency >85% , THD(I) <10% , driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be provided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index >70 and CCT 5700K ±355K. Driver current <1000mA shown in LM79 report. Fixture shall be IS 10322 Compliant. All as per pre approved by Engineer in-charge.
629High Power LED Flood Light 30W
630P & F 1.2mm thick M.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mm length extended on each side . All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR
631P & F 3.0 mm thick Poly propelene plastic polished concealed fan box, squre of size (106x106) mm dia, depth 50 mm , 10 mm dia rod of MS with chrome plated with 55 mm length extended on each side . All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .
632Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSRMCB 6 A to 32 A rating
633Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR
634Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR. 12 way
635S&F following sizes of ISI marked ( IS:14927 P - II ) virgin material UPVC trunking along with accessories like coupler, inner, outer, elbow, square box, tee, end cap etc. on surface with screws, expansion fasteners as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR.25mmx12mm
636S&F following sizes (dia.) of ISI marked ( IS:9537 P - II ) rigid steel conduit with wall thickness according to IS Specified along with ISI marked (IS:14768 P-II 2003) accessories in recessed using saddles, clamps, fasteners, pvc bushes, check nuts, as required including cutting jhiris in the wall and making good the same as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR.25mm
637Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating ,minimum width of switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in-charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR.
638(A) 10Aone way switch
639(B) 10 A two way switch
64016 Amp. 2 Module switch With Led Indicator
641(D) 5 step fan regulator 100 watt 2 Module
642Providing & Fixing of following size mounting grid plates with cover plates made from fire retardent UV established high-performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .
643(A) 4 Module
644(B) 12 Modules
645Providing & Fixing of extra down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steel pipe including cutting, threading, drilling, fixing quarter pin etc as reqd. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR
646Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR .(900/1400 RPM)
647Providing & Fixing of ISO certified company made TP&N 415 V AC-23A front handle operated switch disconnector fuse unit, cubical type, with metallic enclosure, as per PWD specification for electrical Works conforming to IS/lEC 60947-3 : 1999 with HBC fuses including making connections with lugs, testing etc as required. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR100/125 A rating
648SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% ICU. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR160 Amp , 25 kA, adjustable O/L & adjustable S/C setting
649Providing & Fixing of ISO certified company made bus bar chamber housed in sheet metal box as per PWD specification for electrical Works Confirming to IEC-60439/IS-8623 & IEC-60529/IS-2147 made out from 1.6 mm thick powder coated CRCA sheet,degree of protection IP-31, front openable bus bar made out of aluminium or wrought aluminium alloy suitable for 100 amp. Capacity , bus bar fixed on porcelain/DMC insulators at approved spacing including making connections etc. as required. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \"A\" attached with this BSR.450 mm long , 4 strip
650Providing, installation, testing and commissioning of vacuum Feed Gas Chlorinator system with all accessories and making connection with existing pipeline required including supply & installation of ejector unit, Vacuum chlorination unit, trunnion roller support, auxiliary container valve, flexible copper connector, manifold valve, tonner manifold pipes, chlorine Pressure gauge, Isolation valve, gas filter, pressure reducing valve, chlorine gas pipe with fittings, diffuser, lifting beam, load indicator, 25 NB PP diaphragm Valve on injector inlet & outlet, 32 OD uPVC pipe for chlorine solution, 25 NB GI pipe for pump suction & delivery, 25 NB GM gate valve on pump suction & delivery, 25 NB GM \"Y\" type strainer on pump suction, 25 NB GM Check valve on pump delivery, pressure gauge with Isolated valve on pump delivery and chlorine booster pump with motor of required capacity including safety equipment complete in all respect as per specification and the direction of the Engineer.
6513 Kg/hr capacity
652Supply of Chlorine Tonner as per specifications with rollers complete 3 in all respect as per the direction of Engineer.
653Construction of Chlorine Shed (5 m x 4 m x 4 m)
654Construction of Chlorinator Room(5 m x 4 m x 5.5 m)
655Construction of Tonner Room (4 m x 3 m x 3.5 m)
656Construction of Quenching Tank
657Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge.(External work).25 mm
658Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved byauthority specification and the direction of the Engineer.Apply corrosion, resistant, protection on inside and outside of casing pipeas per technical specification.
659300 mm Dia 8 mm thick casing pipe.
660400 mm Dia 8 mm thick casing pipe .
661500 mm Dia 8 mm thick casing pipe .
662700 mm Dia 10 mm thick casing pipe .
663Providing, laying and jointing RCC NP4 jacking pipe (with steel pushing collar) with suitable leak proof joints (with using `12mm MDF sheets etc.) with compliance for maintaining slope as per design by trenchless method adopting Micro tunnelling method or any suitable mechanical technology below ground at all depth under running traffic condition including carrying out survey work at the job site for determining underground cable trenches like telephone, power cable, water & sanitary lines and resistivity tests for finding the soil strata using necessary equipment’s for completion of work, mobilizing of machineries and specialized crew at the job site, etc. complete in all respects, including excavation of drive pit and exit pit (upto 3 metre depth) with proper protection at the three sides, providing and casting of MS cutting edges for front shield and constructing thrust bed at designed level as directed by the Engineer, necessary de-watering and providing concrete foundations at the base of the Drive pit, crane for handling of pipes, and any other machinery, tool & tackles required, construction of temporary works as per requirement complete in all respect (all depths) with all lead and lifts, as per specification and the direction of the Engineer. Note- 1. Manual Pipe jacking is not permitted for workmen safety reasons. 2. Length of pipe shall be measured in between the outer wall of two manholes / Inspection chambers. Pipe in the manhole/inspection chamber’s wall shall deemed to be included in the item of manhole/inspection chamber shall not be payable.
6641600mm dia RCC pipe
665Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like with pumping set of following H.P. including P.O.L./Power consumption etc. complete.
666Hire charges of Pumpset of capacity 4000 litres/hour
667Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift.
668SITCofstarratedAluminiumwounddistributionTransformerof followingrating11/0.433KVDelta-StarConnected,VectorGroup Dyn 11,ONAN Cooled & as per BEE star - 1 & BIS approved as per IS2026-1977&lossesasdefinedasper2014(FourthRevision) Level-1 . including standardaccessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise inwinding/oil 35-40 degree C upto 200 KVA& 40-45 degree C forabove200KVA,ISImarkeddrainvalve,DialtypeTemperature gauge,firstfillingoftransformeroilasperIS:335-1953,Epoxy basedpaint,includingcarryingofpre-commissionTesting& Charging of Transformer complete in all respect . TheTransformershallbesubjectedtoroutinefactorytests(asperIS:2026 and IS:1180) including testing from CTLof discombeforecharging of transformer & complete installaion must be certified from ElectricalInspectorateofficeasperIndianElectricityrule,(CTL testingchargesandElectricalInspectionchargesshallbe reimbursedbythedepartmenttothecontractor).Allasperpre approvedbyEngineerin-charge.Foradditionaltechnical parametersofproducts/work,refer Annexure\"A\"attachedwith this BSR .
669160KVA
670200KVA
671250 KVA with Off -LTC (+5% to - 10% @ 2.5%)
672315 KVA with Off -LTC (+5% to - 10% @ 2.5%)
673400 KVA with Off -LTC (+5% to - 10% @ 2.5%)
674Supply,installation,testing&CommissioningofCopperwound distributionTransformeroffollowingratingand%Impedance, 11/0.433KVDelta-StarConnected,VectorGroupDyn11,ONAN Cooledlosses as per IS 1180 part I 2014 (Fourth Revision) Level-1, withboltlesscoredesignincludingstandardaccessorieslike conservatorwithprismaticoillevelgauge,silicagelbreather,Bucholz relay,pressed steel radiator fins, Radiator Valve(above 800 Kva)SuitablesizeHTcablebox,LTcableboxwithBusbar connection for outgoing cables, Off -LTC (+/- 2.5%, +/- 5% to - 7.5% ),temperature rise of 40 degree C in oil / 45 degree C in winding , drain valve, Air release device,Dial type Oil & Winding Temperature gauge with alarm & trip contacts, first filling of transformer oil as per IS:335-1953,EpoxyprimerandPUbasedpaintasTopcoat, Unidirectionalrollersforratingupto800kva&bi-directionalabove 800Kvarollerswithlockingarrangementetc.asrequired.The Transformershallbesubjectedtoroutinefactorytests(asper IS:2026 and IS:1180) including Temperature rise test inOEM\"s own lab shall be witnessed by Department engineer Physically.Transformer shall be tested from CTLof discombefore charging of transformer&completeinstallaionmustbecertifiedfromElectrical InspectorateofficeasperIndianElectricityrule,(CTLtesting chargesandElectricalInspectionchargesshallbereimbursedby the department to the contractor)Following tests shall be carried out oneachtransformeratsitebyOEMenginerinpresenceof departmentauthorisedrepresentative:-a)Ratiotestoneach tapping.b)Resistanceofwindingsatprincipalandalltapings.c) Insulation resistance of the winding between HV to earth / HV to LV / LV to earth.d) Vector group test.e) Magnetic Balance test. All as per preapprovedbyEngineerin-charge.Foradditionaltechnical parameters of products/ work, referAnnexure \"A\" attached with this BSR .
6751600KVA
676Supply&InstallationofD.P.StructureWithAIRBREAKSWITCH having following specifications A, B, C, D, E. All as per pre approved byEngineerin-charge.Foradditionaltechnicalparametersof products/ work, refer Annexure \"A\" attached with this BSR .A)Doublepolestructureon2noISMB(Ibeam)of size150x75 mm, 10 mtrlengthusing7noMSchanneleachofsize100mmx 50mmx2500mmcompleteinallrespectwithnuts,springs washers, clamps as required. B)Offloadtypegangoperated3-poleverticalflutetypeswitch suitablefor11KV;400A,3-ø,centralpostrotatingdoublebreak isolator complete with MS hardware , copper moving & fixed contact ,assemblyof9nospininsulator,GIpipeofsuitablelengthfor operation. C) 3nos Vertical / Horizontal mounted 11kv horn gap fuse set /drop out 11kv barrel fuses mounted on 6no pin insulators D)3piecenonlinearresistortype.lightingarrestorofapproved makesuitablefor3wire,11kvOverheadlinewith ratedvoltageof 9kv rms & nominal discharge current rating of 5 ka & complete with galvanizedclampingarrangementGIbolts,nuts,washeretcas required. E)3no11kvACSRconductorsmountedonpintypeinsularorsas required.6.GENERAL:Thegoshallbeoperatedbyhandoperated liver properly earthed with provision for locking mounted at 3’
677SITCofHTmeteringcubicalpanelasapprovedByDISCOMs fabricatedout of18SWG CRCAsheet steelintwocompartment& MSangleofsize60mmX6mmhavingprovisionforFollowing: (i)ProvisionforfixingTrivector/Import-ExportMeter(Tobe supplied by DISCOMs) (ii)Provision for fixing of combined CT PT Set withCopperstripforConnection(TobesuppliedbyDISCOMs), (iii)Test terminal Block, (iv) 6mm thick Bakelite sheet on all sides, (V) 3/6 corex 1.5 / 2.5 Sq.mm copper cable for interconnections,etc. as required.AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .
678SITCof11kV630Amps21KAfor3Sec.SF6insulated,outdoor duty (IP54) , Extensible / Non extensible typeRing main unit (RMU)manually operated in combination ofVCB modules andLoad Break switchconsistingofCopperbusbarinSF6insulated304(Non-FerriteNon-MagneticGrade)stainlesssteelenclosureofthickness 2.5mmwithmanometer.TheHVswitchgearandcontrolgear shouldbeconfirmingtoIEC-62271-100,IEC-62271-200-2003& IEC-60694-1996.TheRMUshouldbeinternalarctestedfor21KA for1SecondwithIAC-AFLclassificationforgastank.Vacum Interrupter of VCB should be RMU Manufacturer’s own make.Each feederofRMUshouldhavevoltagepresenceindicator..and compringoffollowings:-1no.microprocessorbasedSelfpowered numericalrelaywithoverCurrent/earthfault&shortcircuit protection with each VCB feeder. - 3 Nos. Protection CT shall be of Burden2.5VA,ratio50/1A,ClassofAccuracyclass5P10forO/C and E/F protection for each VCB.- 1 No. Manometer for each tank,- 1nos.FaultPassageindicator,-Rightanglebootsforallthefeeder ModulesAllthetypetestcertificatesasperIECfromThirdpartyNABL / CPRI / ERDA accrediated lab to be submitted. (Cost of RCC Foundation/SteelStructuretobepaidExtra)Allasperpre approvedbyEngineerin-charge.Foradditionaltechnical parametersofproducts/work,referAnnexure\"A\"attachedwith this BSR
679Extensible 2 way RMU with 1 no. VCB & 1 No. Load Break Switch
680Providing & Laying XLPE insulated three core ArmouredAluminiumcable for working voltage 11 K.V.(E) confirming IS :7098 P - 2withH4-GradeelectrolyticaluminiumconductorconfirmingtoIS:8130 class-2ofpurity>99.6%,InsulationScreening:Extruded SemiconductingCompoundfollowedbyhelicallywrappedCopper Tape,round/flatstriparmouringofcables,Inner/outersheath PVCtypeST-2confirmingtoIS:5831inexistingRCC/Hume/ Stoneware / PVC pipe/ open duct/cable trench / Cable tray includingtesting etc. as required of following size. OEM must have it\"s own in houseNABLaccrediatedLaboratoryfortestingprocedureasper IS:10810AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .
6813 core 95.0 Sq.mm
682Providing&makingheatshrinkabletypeindoor/outdoor/straight through terminations/ joint kitsuitable for11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test reportshouldbeasperIS13573:2011whichcoveredallsequence fortable2forterminationkitandtable3forstreightthroughjoint inclusive thermal & dynamic short circuittest, humiditytest, soil fog test.CrosslinkingshallbedoneoutsidefactorywithE-beam/ peroxidetechnology.ExtrusionprocessshallbeinhouseOEM withinsamevicinity.includingtestingetc.asrequiredoffollowing sizes. All as per pre approved by Engineer in-charge. For additional technicalparametersofproducts/work,referAnnexure\"A\" attached with this BSR .
6833 core 50/70/95 Sq.mm
6843 core 50/70/95 Sq.mm
685Supply, receving, storing,inspection, handling , assembilng ,installing in correct alligned position, effecting proper connections,testing and commissioning of copper wound Transformers 33/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories with off load tap changer(+5% to -10% in steps of 2.5%), winding / Top --- temperature rise of 450/400 C first fill oil, having permissible totak less values not exceeding 7.5% of the maximum total loss values for 11KVasperenergyefficiencylevel-2atbasicInsulationlevel conferming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014.
6861000 KVA
6875000 KVA (33KV / 6.6KV) AS PER IS 2026
688Supply,Installation,testingandcommissioningof33KVDouble PolestructurewithAirBreakSwitchhavingfollowing specifications.a) DP : Double Pole structure made of two nos. 11 m long PCC poles (400Kg) & 7 nos. MS Channel size 100x50x6mm complete with earthing of the structure as perREC standardsin all respect with nuts, springs washers, clamps as required.b) GO: Off load type gang operated three pole Horizontal type switch suitable for 33KV, 800A, 3phase central post rotating double break isolator completewithMSHardware,coppermoving&fixedcontacts, assembly of 9 Nos. Post Insulators, GI pipe of suitable length for operation.c) DO: 3 Nos. Horizontal/Vertical mounted 33KV Horn Gap fuse set / Drop Out fuse set, 33KV barrel fuses mounted on 6 Nos. Postinsulators.e)LA:3piecenonlinearresistortypelightening arrestorofapprovedmakesuitablefor3wire,33KVohlinewith rated voltage 30KV rms & nominal discharge current rating of 10 KA & complete with galvanized clamping arrangement, GI bolts, nuts, washers etc. as required.e)Jumpers:3 Nos. ACSR Dog Conductor mountedonpintypeinsulatorsasrequired.TheGOshallbe operated by hand operated liver properly earthed with provision for locking mounted at 3’. Complete as per technical specifications and /or as directed by engineer.
689Supply, Installation, Testing and Commissiong of indoor type floor mountedmetalclad,33KVIncomerVCBpanelupto630A equipped with following switchgears and accessoriesdesigned & tested as per latest standard i.e. IEC 62271-200, suitable for STC 31.5KA/3andIACA-FLRfor31.5kA/1sec.MakeofHTPanel, Vaccum Interrupter and VCB should be of same make.
69033 KV / 110 Volts PT Class 0.5 accuracy and 100 VA burden with 1No. Voltmeter (0-36 KV), analog type, selector switch for voltmeter and protection fuses/MCB for HT metering upto 36 KV on incomer, Ammeter,analogtype,selectorswitchesforammeters, MicroprocessorbasednumericalrelaywithO/L,E/FandS/C protection, Set of dual core dual ratio 3CTs of suitable ration with sec 1 of 15 VA burden and accuracy Class – 0.5 for metering and class 5P10 for protection, Multifunction Meter.
691Supply, Installation, Testing and Commissiong of indoor type floor mountedmetalclad,33KVBusCouplerVCBpanelupto630A equipped with following switchgears and accessories. STC 31.5KA/3 and Internal Arc test A-FLR for full short circuit current for 1 sec. duration. Make of HT Panel,Vaccum Intrrupter and VCB should be of same Make. Bus Coupler 1 No 630 Amp. VCB
692Supply, Installation, Testing and Commissiong of indoor type floor mounted metal clad, 33 KV Incomer cum outgoing VCB panel up to 630Aequippedwithfollowingswitchgearsandaccessoriesdesigned&testedasperlateststandardi.e.IEC62271-200, suitable for STC 31.5KA/3 and IAC A-FLR for 31.5kA/1sec. Make of HT Panel, Vaccum Interrupter and VCB should be of same make.
69333 KV / 110 Volts PT Class 0.5 accuracy and 100 VA burden with 1No. Voltmeter (0-36 KV), analog type, selector switch for voltmeter and protection fuses/MCB for HT metering upto 36 KV , Ammeter, analog type, selector switches for ammeters, Microprocessor based numerical relay with O/L, E/F and S/C protection, Set of dual core dual ratio 3CTs of suitable ration with sec 1 of 15 VA burden and accuracyClass–0.5formeteringandclass5P10forprotection, Multifunction Meter
694SITC of battery bank of min 150 AH capacity comprising SMF/VRLA batteries,FCBC(Floatcumboostcharger)suitablefor415V+/-10%,50Hz,1-ǿ / 3 -ǿ Input & 24/ 48 /110 V DC Output Natural Cooled,freestandinginSheetSteelenclosure,SCRcontrolled, regulation+/-1%,Efficiency>75%onFLAC/DCInstruments, SelectorSwitch,BuiltinDCDistributionBoard(6NoMCB), indication , control as required. All as per pre approved by Engineer in-charge.Foradditionaltechnicalparametersofproducts/work, refer Annexure \"A\" attached with this BSR .
695O.L.T.C. With R.T.C.C. & AVR (for 33KV)
696Providing & Laying XLPE insulated three core ArmouredAluminiumcable for working voltage 33 K.V.(E) confirming IS :7098 P - 2withH4-GradeelectrolyticaluminiumconductorconfirmingtoIS:8130 class-2ofpurity>99.6%,InsulationScreening:Extruded SemiconductingCompoundfollowedbyhelicallywrappedCopper Tape,round/flatstriparmouringofcables,Inner/outersheath PVCtypeST-2confirmingtoIS:5831inexistingRCC/Hume/ Stoneware / PVC pipe/ open duct/cable trench / Cable tray includingtesting etc. as required of following size. OEM must have it\"s own in houseNABLaccrediatedLaboratoryfortestingprocedureasper IS:10810AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .
6973 core 185.0 Sq.mm
698Providing&makingheatshrinkabletypeindoor/outdoor/straight through terminations/ joint kitsuitable for11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test reportshouldbeasperIS13573:2011whichcoveredallsequence fortable2forterminationkitandtable3forstreightthroughjoint inclusive thermal & dynamic short circuittest, humiditytest, soil fog test.CrosslinkingshallbedoneoutsidefactorywithE-beam/ peroxidetechnology.ExtrusionprocessshallbeinhouseOEM withinsamevicinity.includingtestingetc.asrequiredoffollowing sizes. All as per pre approved by Engineer in-charge. For additional technicalparametersofproducts/work,referAnnexure\"A\" attached with this BSR .
6993 core120/150/185 Sq.mm
7003 core120/150/185 Sq.mm
701PlateEarthlingasperIS:3043withcopperEarthplateofsize 600mmx600mmx3.0mmbyembodying3to4mtr.Belowthe ground level with 25 mm dia. G.I. ‘B’ class watering Pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and C.C.finishedchambercoveredwithhingedtypewithlocking arrangementC.I.Cover,C.IFrameofsize300mmx300mm completewithalternatelayersofsaltandcoke/charcoal,testingof earth resistance as required.
702Pipe Ear thing as per IS: 3043 with perforated 3.0 Mtr. Long, 40 mm dia.‘B’classG.I.Pipeincludingallaccessorieslikenut,bolts, reducer,nipple,wiremeshedfunnel,andC.C.finishedchamber coveredwithhingedtypewithlockingarrangementC.I.Cover,C.I. Frame of size 300mm x 300 mm and embodying the pipe complete withalternatelayerssaltandcoke/charcoal,testingofearth resistance as required.
703S & Laying following size ‘B’ Class G.I.Pipe confirming to IS: 1239 P-1 (1990) with accessories for laying earth conductor/ strip/ cable in ground/ surface/ recess as required.
70450 mm dia.
705Supply&Layingfollowingsizeearthstripinhorizontalorvertical runinsurfacebymeansofEarthstripDMCInsulatorincluding riveting/soldering/welding,Jointingshallbedonebyoverlapping andwith2setofBrass(forCustrip)/GI(forGIStrip)nutbolt& springwasherspacedat50cmmakingconnectionetc.as required.AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .
70650mm x 6mm copper strip
70725mm x 6mm G.I. ( Hot Dipped) Strip
70832mm x6mm G.I. ( Hot Dipped) Strip
70950mm x 6mm G.I. ( Hot Dipped) Strip
710Supply,Fabricating&installingfollowingsizesofperforatedHot dippedGalvanizedironcabletray(Galvanizedthicknessnotless then 50 microns) with perforation not more then 17.5% in convenient sectionincludinghorizontalandverticalbends,reducerstees,cross membersandotheraccessoriesasrequiredanddulysuspended fromtheceilingwithGIsuspendersincludingGIbolts&nuts, fastners,supportsetc.asrequired.Allasperpreapprovedby Engineer in-charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .
711100mm x 50mm x 1.6mm
712150mm x 50mm x 1.6mm
713300mm x 50mm x 1.6mm
714SupplyinganddrawingPVCinsulated&sheathedsolid/stranded copperconductormulticorecontrolcableISImarked(IS:1554)of 1.1kVgradeofapprovedmakeasperchapterE11,inexisting surfaceorrecessedconduit/casingcappingincludingmaking connections etc. as required.
7154 core, 1.5 sq. mm. armoured
7168 core, 1.5 sq. mm. armoured
7178 core, 2.5 sq. mm. armoured
71819 core, 2.5 sq. mm. armoured
719Providing&LayingP.V.C./XLPEinsulated&P.V.C.sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - Iof1.1KVwithH4-Gradeelectrolyticaluminiumconductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC /Hume/Stoneware/PVCpipe/openduct/cabletrench/Cable tray(withcabletie)includingtestingetc.asrequiredoffollowing size.OEMmusthaveit\"sowninhouseNABLaccrediated LaboratoryfortestingprocedureasperIS:10810.Foradditional technicalparametersofproduct/workreferAnnexure\"A\"attached with this BSR
720400 SQMM,3.5 CORE
721300 SQMM,3.5 CORE
722120 SQMM,3.5 CORE
723240 SQMM, 3 CORE
724185 SQMM, 3 CORE
725120 SQMM, 3 CORE
72695 SQMM, 3 CORE
72770 SQMM, 3 CORE
72850 SQMM, 3 CORE
72935 SQMM, 3 CORE
73025 SQMM, 3 CORE
73116 SQMM, 3 CORE
73210 SQMM, 3 CORE
7334.0 SQMM, 3 CORE
734SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/freestandingfloormounteddustandverminproof compartmentalisedcubicalpanelasspecificationsandOther parameters requiredas per point (a) ,(b), (c),(d, (e), (f), (g), (h) as below:-(a)ThicknessofCRCAsheetshallbe2.0mm,cablealley compartmentshavingconcealedhingedtypedoorswithkeytype lock with / withoutdetachable extension type structure. Removable 3mm.thicksheetsteelglandplateswithappropriatesizeof knockouts for cables shall be provided(b)completepanelshallundergoaprocessofdegreasing,Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panelhavingPEfoam/Neoprenerubbergasketofnotlessthan 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) nterconnectionbetweenbusbarandswitchgears/cableshall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried outwith1.5Sq.mm,Earthwirewith2.5Sq.mmandCTwith2.5 sq.mmflexiblecopperwireonly.Alljoints/interconnectionsof copper bus bar shall be dully tinned . Clearance between main bus barandrisers/metalpartsshallbeatleast10mmadditionalto widthofbusbarBusbarisinsulatedbyHeatShrinkablesleeves. Earth and Neutral bus bar shall be half of the size of phase bus bar. (CostofBusbar/FlexiblewireforInterconnectionbetweenMain connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)FloormountedpanelshallbemountedonBaseframeofISMCchannel size 100 x 50 x 5 mm( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute)shallbemeasuredbetweenphases,betweenphaseand neutralandbetweenphaseandearth.bothbeforeandafterhigh voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. (h) only outer surface area on all sides shall be measured & panel to befabricatedonlyfromCPRIapprovedfabricatoronly(CPRITest certificates to be submitted)All as per preapproved byEngineerin-charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .busbar and Switchgearis to be Paid Extra ) (d)WiringbetweencomponentswithinswitchgearandIncoming/ outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted.Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads,studswithtwonutsandidentificationstripsandshallhave adequate continuous current rating. For tap-offs, adjacent terminals withshortingstripsshallbeused.10%Spareterminalblocksshall be provided. Wire identification on marking strip shall correspond to thedesignationofthewiringdiagrams.Allwireterminalsonthe equipmentshallalsobemarkedwithdesignationcorrespondingto those of the wiring diagram. (e)Allwiringshallbeenclosedinplasticchannelsandneatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee
735SupplyingandfixingofAluminium(IEC60105ISO209-1,2)/ Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwithstandardshortcircuitwithstandcapacity,hightensilenuts and bolts spring washers in existing panel including bending , cutting inrequiredshapeandsizeandcolourcodingwithheatshrinkable PVCsleeves.AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .
736Electrolytic grade Aluminium bus bar 6010 grade
737Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type(up to 500) V range Volt meter / Direct- Ammeter /CT oertated ammeter/Frequencymeter/KWHmeter/MultiFunctionMeter/ Power analyzer of class 1 accuracyas per IS : 1248 of size 96mm x 96mmincludingmakingconnectionbyPVCinsulatedcopper conductorwithPVCsleeves/channeletc.asrequired.Allasper preapprovedbyEngineerin-charge.Foradditionaltechnical parametersofproducts/work,referAnnexure\"A\"attachedwith this BSR .
738Three phase with universal Auxiliary supply + AMP + HZ + PF + KW +KVA+KVAR+KVARH+KWH+DUALENERGY+ ENERGY+THD-I, THD-V & RUN HRS + MD with RS485
739ThreephaseAMP+HZ+PF+KW+KVA+KVAR+T.ENERGY+THD-I, THD-V & RUN HRS
740Providing&FixingofBISapprovedCurrentTransformerasper PWD specification for electrical Works ,ISI marked as perIS 2705-1992/conformingtoIEC60044-1,withsecondaryterminalofCT shallbebroughtoutsuitabletoaterminalblockwhichshallbe easieraccessiblefortestingandterminalconnection,withall necessarysupportinexistingpanelincludingconnectionetc.as requiredCurrenttransformerRingTypeTapeWound/ResinCast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified.ISF<=5,Cucrosssectionofsecondarywire1.5sqmm (minimum),includingallnecessarysupportinexistingpanel includingconnectionetc.asrequired.Allasperpreapprovedby Engineerin-charge.AllasperpreapprovedbyEngineerin-charge. Foradditionaltechnicalparametersofproducts/work,refer Annexure \"A\" attached with this BSR .
741C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA
742C T Class 1, Ratio 400/5 to 1200/5, Burden 15 VA
743C T Class 1, Ratio 1600/5 to 3000/5, Burden 15 VA
744Providing & Fixing ofCam operated rotary (Auto/manual) switches onexistingpanelwith2wayandoffpositionusinghighgrade engineeringmaterialtointernationalstandardswithcamassemblyinsulationofglassfilledpolyamidewithhightrackingindex.For reliable and stable electrical and mechanical endurance double butt contactswithsilverbi-metaloncoppershouldprovidedcontact assemblyis of operating temp range-25 degree C to55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanicallyminimum50000operations@300cycles/hourand electrically10,000operationsat100%rateddutyfor100cycles/ hourincludingmakingconnectionetc.asrequired.Allasperpre approved by Engineer in-charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .
74510 AMP
74616AMP
747Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947withintegralcircuit,IP65abovepanel&IP20terminal block,Approx.bodydiaforpanelnot lessthen20mm,lengthmin. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per preapprovedbyEngineerin-charge.Foradditionaltechnical parametersofproducts/work,referAnnexure\"A\"attachedwith this BSR .
748Red/yellow/Blue
749Red/Gree/ white Colour
750Red/Gree/ white Colour
751Red/Green
752Providing&FixingofflushheadpushbuttonactuatorsIEC60947withintegralcircuit,IP65abovepanel&IP20terminalblock, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze forLed,PCBcontactsshallbeofbrass(tinplated),impulsedielectrictestedfor2.5KV,includingconnectionetc.asrequired.AllasperpreapprovedbyEngineerin-charge.Foradditional technicalparametersofproducts/work,referAnnexure\"A\" attached with this BSR
753Non luminous type
754Providing & Fixing of Electricalinsulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 /2006 withonesideantiskidabberationmarksandpastingthe matwithsyntheticrubberadhesiveasrequired.Allasperpre approved by Engineer in-charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .
75511 KV,Class B 2.5 mm thick with proof voltage 22 KV AC (rms) and Break Down Voltage45 KV AC (rms)
75633 KV,class C 3 mm thick with proof voltage 36 KV AC (rms) for3 min. and Break Down Voltage 65 KV AC (rms)
757SITCof3/4polecurrentlimitingMouldedcasecircuitbreaker (MCCB)madeofflameretardent&heatresistantmaterialhaving followingcurrentrating,shortcircuitbreakingcapacityat440/415 V,50Hz;O/L&S/Csettings,conformingtoIS/IEC60947P-2 :2003withfrontfaceandcentralisedadjustable,tripfree mechanisum,truecontactpositionindicator,lineload interchangeability, designed for both horizontal&vertical mounting withoutanyadverseeffectonelectricalperformance,suitablefor operationupto55degreeandwithoutderatingupto40degree,pollution degree 3, having positive isolation capability, push(test) totrip,triptimelessthen10msunders/ccondition,Breaking capacity Ics = 100% ICU. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock&rotaryhandle,includingmakingconnectionsetc.as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR
758250 Amp , 35 kA, adjustable O/L & adjustable S/C setting,
759400 Amp , 35 kA, adjustable O/L & adjustable S/C setting,
760630 Amp , 50 kA, adjustable O/L & adjustable S/C setting,
761Extended Rotary Handle
762Mechanical Interlocking kit
763Auxiliary + Trip alarm contact
764Spreaders for 250A, 4 Pole MCCB
765Spreaders for 400A, 4 Pole MCCB
766Spreaders for 630A, 4 Pole MCCB
767SITCofDrawouttype3/4poledoorinterlockAirCircuitBreaker (ACB)asconformingtoIS/IEC60947P-2:2003inexistingLT panel suitable for LT installation 440 V, 50 Hz and having adjustable overloadshort-circuit,Instantaneous,earthfault(LSIG)withseparateLEDindicationforeachtypeoffaultshallconfirmto EMI/ EMC test, LCD/LED display, last 10 trip history, provisionofZSI, Communication, Power metering module, Thermal memory , trip free mechanisum,suitableforambient50degreeandutilization catagaryB.Inbuiltelectrical&mechanicalantipumpingfeature, 100% rated neutral . ACB shall have separate indication for service, test, isolation & maintenance position, Breaking capacity Icu = Ics = Icw(1sec),Uimp-12KV,breaktimenotmorethen25ms. Provisionforelectrical&mechanicalinterlockbetweenACBs, Min.electricaloperation10000upto2000Aratingand5,000for 2500Ato4000A.includingmakingconnections,testingetc.as required. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineerin-charge.Foradditionaltechnicalparametersofproduct/ work refer Annexure \"A\" attached with this BSR
7682500 A Rating ,50 kA
7691600 A Rating ,50 kA
770SupplyandfixingoffollowingaccessoriesforAircircuitbreaker (ACB)compatiblewithMAinACBOEMasperPWDspecification forelectricalWorks,conformingtoIS/IEC60947P-2:2003 includingmakingconnectionetccompleteinallrespect.OEMshall havesubmitNABL/CPRI/ERDAaccrediatedlabtypetest certificatebeforeexecution.Allasperpreapprovedby Engineer in-charge.Foradditionaltechnicalparametersofproducts/work, refer Annexure \"A\" attached with this BSR .
771Shunt Trip Release
772Under voltage Release
773Microswitch for Indication
774Operation Counter
775Door Interlock
776Auxiliary Contact 4 NO + 4 NC
777Breaker Control Switch (TNC)
778Providing& Fixing of IP54 microprocessor based 3CT’s for all 3 phasesensingcompensationpowerfactorcorrectionrelaySize 139mm x 139 mm, Operating Voltage 415/440 V, IEC / EN 61000-6-(2&4)having3CTsensing,sensitivityupto50milliamp secondarycurrent,selfanalysingautoc/ksettingaccordingto targeted power factor setting, the relay shall have digit displayunit fordisplayofrealpowerfactor,targetedpowerfactor,lag/lead capacitorswitchingstatus,alarmoutputforundercurrent,over current, insufficient compensation, communication interface with RS 485,indication of switching onunits, auto/manual status, and shall haveoverloadprotection,novoltrelease,havingmultiparameter like KW, KVA, KVAR, RMS Value, step switching time 2 sec to 1800 sec. Lead & Lag parameters, metering facility and3 no. Class- 0.5 Cast ResinCT ( refer CT specs in this chapter )for sensing the relay includingmakingcoonectionwith1.5Sq.mmcopperwireetc.as required.AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .
7796 to 8 stage
78012 to 14 stage
781Providing&FixingofselfhealingIP20MPPtypeshuntcapacitor (banks) conforming to IS:13340-41 /IEC :831-1&2 OR IEC : 60831-1&2inexistingpanelorparallelwithloadterminals,thecapacitor shallbefittedwithdischargeresistors,pressuresensitive disconnector(PSD)andshallhavedissipationfactorlessthan 0.0025 at 50 Hz, Operating loss less than 0.30 Watt per KVAR. Min overcurrentcapacity1.8timesratedcurrent&peakinrushcurrent min.300timesofratedcurrent,llifeexpectancygreaterthan 100000hrs(tempclass-25D)in440V/480VCapacitorandfor 525 V should life expectancy minimum 1,65,000 hrs (temp class - 25 D)including making connections, testing etc. as required.All as per preapprovedbyEngineerin-charge.Foradditionaltechnical parametersofproducts/work,referAnnexure\"A\"attachedwith this BSR .
782HeavydutyThreephase440V,50Hzcylindricaltypecapacitor (Bank)
783Providing&Fixingof440Volt3polecapacitor(AC6B)duty contactor with 3 no. early make and post break auxiliary contacts in serieswithquickdischargedampingresistors/reactorstolimitthe inrush current as per PWD specification for electrical Works,IS/IEC 60947-4-1:2000,insulationvoltage1000V,impulsewithstand voltage8KV,Dinrailmountingtypeincludingmakingconnections, testingetc.asrequired.suitableforfollowingcapacitycapacitor bank.All as per pre approved by Engineer in-charge. For additional technicalparametersofproducts/work,referAnnexure\"A\" attached with this BSR .
784up to 6 KVAR
78510 KVAR
78615 KVAR
78725 KVAR
78850 KVAR
789Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kAbreakingcapacity(B/C/Dtrippingcharacteristicaspertypeof loadandsiterequirement)4KVimpulsewithstandvoltage,ISI markedIS8828(1996)/conformingtoIEC60898-12002,IEC 60947-2,lowwattlosses,tripfreemechanisum,energylimitingofclass3asperIEC,minimumphaseterminationcapacityof 35sq.mm. , conductor line load reversibility , IP 20 contact protection andfittedinexistingdistributionboard/sheets,minimumelectrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A&aboveratingincludingmakingconnections,testingetc.as required. OEM shall have submitNABL / CPRI / ERDA accrediated labtypetestreports&AllasperpreapprovedbyEngineerin-charge.Foradditionaltechnicalparametersofproduct/workrefer Annexure \"A\" attached with this BSR
790Triple pole MCB(With B/C curve trippingCharacteristics), 6 A to 32 A rating
79150/63 A rating
792125A rating
793Four pole MCB (With B/C curve tripping Characteristics), 6 A to 32 A rating
794Double pole MCB(With B/C curve tripping Characteristics) , 6 A to 32 A rating
795SITCofSoftStarterswithpanelsuppliedbymanufacturer conforming to applicable standards with logic inputs & outputs, relay outputsandanalogueoutputs,pluginI/Oconnections,displayof electricalparameters,stateofload&operatingtime,RS485serial link for connections to Modbus.
796200KW
797160KW
79890KW
79975KW
80055KW
80145KW
80237KW
80330KW
80422KW
805S&FofStardeltaStarterwithMCB,MainandAuxContactor,O/L Relay,L/RSelectorSwitch,3Indicatinglamps,Start-StopPush Button,ontrolMCBwithpanelwithallaccessorieswithfollowing rating : 11KW
806S&FofStardeltaStarterwithMCB,MainandAuxContactor,O/L Relay,L/RSelectorSwitch,3Indicatinglamps,Start-StopPush Button,ontrolMCBwithpanelwithallaccessorieswithfollowing rating : 15KW
807S&FofStardeltaStarterwithMCB,MainandAuxContactor,O/L Relay,L/RSelectorSwitch,3Indicatinglamps,Start-StopPush Button,ontrolMCBwithpanelwithallaccessorieswithfollowing rating : 18.5KW
808From3.3KWto7.5KWDOLStarterFeederwithMCB,Mainand AuxContactor,O/LRelay,L/RSelectorSwitch,3Indicating lamps,Start-StopPushButton,ControlMCB(Size:600(W) x400 (H) x 600 (D)
809SITC of LocalPush Buttonstation fabricated with 16SWG CRCA sheet,paintedwithpolysterPowdercoatedfinishafterchemical treatmentwithFolliwngitemsandaccessories:- iShroudedTypepushbuttonwith2NOContactselementfor Start/forward-reverse. iiLockableMushroomheadtypepushbuutonwith2NCContact element. iii2.5Sqmmclipontypeterminalsasrequriedwith20%spares. iv 1.5 Sqmm PVC insulated felxible copper wire with lugs & ferrules as requried.
810SupplyanderectionofGalvanizedIronpolewith galvanizingdone insingledipping(AveragecoatingthicknessMinimum65Microns) continuouslytaperedpoleshavingOctagonal/Circularcross-sectionsdesignedtowithstandthemaximumwindspeedasperIS 875,Thepoleshaftshallbemadefromsheetsteel(HTSteel ConformingtogradeS355JO)andconfirmingtoBSEN10025and shall be continuously tapered with single longitudinal welding. There shallnotbeanycircumferentialwelding.Theweldingofpoleshaft shallbedonebySubmergedArcWelding(SAW)process.pole shaftsshallbeprovidedwiththerigidflangeplateofsuitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to thepoleshaftattwolocationsi.e.frominsideandoutside.The octagonalPolesshallhavelockabledoorofapproximate500mm length at the elevation of 500 mmfrom the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) insidethepoleatdooropeningforcableconnectionoffollowing lengthanddimensionaspertableP-01withbaseplateand foundationboltontheExistingcementconcretefoundation.Allas perpreapprovedbyEngineerin-charge.Foradditionaltechnical parametersofproducts/work,referAnnexure\"A\"attachedwith this BSR .
8117 Mtr., Poles with Octagonal Cross Section
812SupplyandFixingofPoleOEMfabricatedhotdippedgalvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in-charge.Foradditionaltechnicalparametersofproducts/work, refer Annexure \"A\" attached with this BSR .
813Single arm overhang
814ProvidingandLayingRCCFoundationforOctagonal/Conical StreetLight poles, High mast Poles as per Drawingattach at TableP-4withFollowingProcedure&Allasperpreapprovedby Engineer in-charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR . A)ExcavationofPitforFoundationSizeuptorequireddepthfrom Ground levelB)DressingofPitandDrystonepitching200mmthickincluding supply of stones and preparing surface complete. C) Providing and laying in position cement concrete of M-10 grade of 75 mm thickness D)ReinforcementforR.C.C.workwithTMTbarsincluding straightening,cutting,bending,placinginpositionandbindingall complete. E)Centringandshutteringincludingstrutting,proppingetc.and removal of form work for Footing and Pedestal F)Providing&Fixingof2no.RequiredSizePLBHDPEPipe& Foundation Bolt with template as per OEM Recommendations. G) Providing and LayingReinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days. H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face.
815Pole Foundation for Octagonal pole from 7 Mtr. To 9 Mtr.
816Providing&FixingofIK08,IP66protectedLEDStreetLight Luminaireonexistingbracket/pole.Fixturemadeofpowdercoated singlepiecepressurediecastaluminummaterialwithheat dissipationfinsonhousingwithUVstabilizedPC(UVstablization reportsubmittedforUVcover)/ToughenedGlasscoverand secondarylensoneachLED&shouldbeSMDtypeof3to5watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with HighvoltageCutoff@>=300VACandAutoresettingSafety, Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. TheluminaireshallbeBIScertifiedandTrademarkcertified.Life ExpectancyEqualormorethan50000burninghrswithMinimum 70%lumenmaintened,CRI>70andCCT5700K+355K.Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside drivercompartment.drivershouldbePhasetophaseprotectionof 440Vfor4Hrs.ManufacturesWordMark/Name Engraved/Embossingondiecasthousingtoallow traceability/authenticity.FixtureshallbeASPERIS10322 Complianced.OEMMusthaveitsowninhouseNABLlabsetupfor alltestingfacilitiesforLEDfixtures.(LM79/LM80)Certificate/ report with liable warranty of product/accessories from OEM shall be submitted.AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .
817LED Street Light fixture with Minimum lumen output 8700 lm
818Providing&FixingofIP-65protectedimpactresistant polycarbonate/Polystereneenclosureswithknockoutforcable entry/outincludingfixingwithnut,bolt,fatneretcasrequired complete in all respect of following sizes.All as per pre approved by Engineer in-charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .
819180 x 180 x 91 mm
820Providing&FixingofStreetlightbracketmadeoutfromfollowing size of \" B \" class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. asrequired.AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .
82132 mm Dia.
822Providing&FixingofIK08IP-66protectedhighpowerLEDflood lightsystemwithsinglepiecePressurediecastaluminiumhousing, toughenedglassdiffuserwithsuitablelensesonLEDtoachieve variousbeamangles,ofhighpowerLEDof3to5watteach. Integrated potted driver as a unique BIS R numberhaving efficiency more than 85 % and in compliance to BIS certified and Trade markcertificate.TheSystemlevelLuminaireefficacy>=125lm/wt.LED driverInputVoltageAC120to270VACwithHighvoltageCutoff @>=300VACandAutoresettingSafety.PowerFactor>0.95, THD(I)<10%,drivercurrent<=750mA.drivershouldbePhaseto phaseprotectionof440Vfor4Hrs.ElectricalConnector,Surge ProtectionMin>=4KVinternaland10KVexternalbutinsidedriver compartment, System life of 50000 Burning hours with 70% of Initial Lumensmaintained,CRI>70andCCT5700K±355K.ManufacturesWordMark/NameEngraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shallbeIS10322Complianced.OEMMusthaveitsowninhouse NABLlabsetupforalltestingfacilitiesforLEDfixtures.(LM79/LM80)Certificate/reportwithliablewarrantyof product/accessoriesfromOEMshallbesubmitted.Allasperpre approvedbyEngineerin-charge.Foradditionaltechnical parametersofproducts/work,referAnnexure\"A\"attachedwith this BSR .
823High Power LED Flood Light Minimum lumen output 10000 lm
824Providing and fixing in position lightening arrester set complete with 600mmx600mmx6mmthickG.I. earthingplate embeddedbelow groundinearthlingpitat3.5metrdepth,G.I.stripofsize 25mmx5mm thick from earthing plate to top of Over head tank, G.I. FinialmadeofGIbar25mmdiaand2mlongfixedontopofOH tankandconnectedtoGIstrip.Theearthlingsetshallcomplyof IS:3043 complete in all respect as per specification and the direction of the Engineer.
825Heavy Duty AL & CU Lugs,Double Compression Cable Gland with Nickel Plated, Cable Tie, Cable Tags, GI Nut- Bolts-Washers, Anchor Fastners, Clamps, Clips, Screw, Washers, Electrical Taps, HT Tap, Danger Plates, 4.5 Kg. CO2 type portable fire extinguisher for Panel Room , Fire buckets with floor / wall mounting stand ect. required hardware & accessories for various sizes as per site requirements.
82633KV Switchyard Civil work for Transformers Foundations, DP Structure, Chain Link Fencying 1500mm Height, MS Gate , 40mm Gravels, boundary wall, Earthing Chambers, HT/LT cable Trench,coversect.
82711KV Switchyard Civil work for Transformers Foundations, DP Structure, Chain Link Fencying 1500mm Height, MS Gate , 40mm Gravels, boundary wall, Earthing Chambers, HT/LT cable Trench,coversect.
828From3.3KWto7.5KWDOLStarterFeederwithMCB,Mainand AuxContactor,O/LRelay,L/RSelectorSwitch,3Indicating lamps,Start-StopPushButton,ControlMCB(Size:600(W) x400 (H) x 600 (D)
829Supplyof indoortype floor mounted metal clad, incoming 6.6 KV VCB panel equipped with following switchgears and accessories. 1. 6.6 KV / 110 Volts PT Class0.5 accuracy and 100 VA burden with 1No.Voltmeter(0-7KV),analog/digitaltype,selectorswitchfor voltmeter and protection fuses/MCB for HT metering upto 7 KV on incomer2. Ammeter, analog type, selector switches for ammeters.3. MicroprocessorbasednumericalrelaywithO/L,E/FandS/C protection.4. Set of dual core dual ratio 3CTs of suitable ratio with sec of 1 A of 15 VA burden and accuracy Class –0.5 for metering and class 5P10 for protection5. Multifunction Meter. Incoming upto 630 Amp. VCB
830Supply, Installation, Testing and Commissiong of indoor type floor mounted metal clad, 6.6 KV Bus Coupler VCB panel equipped with following switchgears and accessories. Bus Coupler upto630 Amp. VCB
831Supplyofindoortypefloormountedmetalclad,outgoing6.6KV VCB panel equipped with following switchgears and accessories. 1. 6.6 KV, analog/digital type, selector switch for voltmeter and protection fuses/MCB for HT metering upto 6.6 KV on outgoing 2. Ammeter analog type, selector switches for ammeters. 3. Microprocessor based numerical relay with O/L, E/F and S/C protection. 4. Set of dual core dual ratio 3CTs of suitable ration with sec 1 A of 15 VA burden and accuracy Class – 0.5 for metering and class 5P10 for protection 5. Multifunction Meter . Outgoing upto 630 A VCB for HT MOTORS
8326.6 KV HT FMCA Digital Soft Starter Panel with reactor for min 500 KW HT VT Motor ,--Inddor Type, Metal enclosed compartmentalized, Short Circuit withstand & duration (Sec.) - 9kA for 1Sec, Rated 7.2 KV ±10%, 50Hz ±5%, 3Ph,IP 4X, Control & Protection Sypply - 110VDC, 10KV for 1min power frequency, 2 Pole Vacuum Contactor 400A, Bus Bar - Copper, FMCA Coils type - Air Core as per IEC 60076-6,Insulation - Class F, Temp. rise limited to class B. Coil material - Copper conductor is wound on Fiberglass bobbin, No of Tappings - 5 nos., Single Power cable Based.
8336.6 KV/ min 350 KVARHT APFC Panel for 500KW HT Motor ,- 7.2KV ±10%, 50Hz ±5%, 3Ph,IP 4X,Control & Protection Sypply - 110VDC, Connection - Line side ( Shunt Connection) , Air Cooled, Bus Bar 400A Copper, Metal enclosed compartmentalized.
834Providing & Laying XLPE insulated three core ArmouredAluminiumcable for working voltage 6.6 K.V.(UE) confirming IS :7098 P - 2withH4-GradeelectrolyticaluminiumconductorconfirmingtoIS:8130 class-2ofpurity>99.6%,InsulationScreening:Extruded SemiconductingCompoundfollowedbyhelicallywrappedCopper Tape,round/flatstriparmouringofcables,Inner/outersheath PVCtypeST-2confirmingtoIS:5831inexistingRCC/Hume/ Stoneware / PVC pipe/ open duct/cable trench / Cable tray includingtesting etc. as required of following size. OEM must have it\"s own in houseNABLaccrediatedLaboratoryfortestingprocedureasper IS:10810AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR .
8353 core 185.0 Sq.mm
8363 core 150.0 Sq.mm
837Providing&makingheatshrinkabletypeindoor/outdoor/straight through terminations/ joint kitsuitable for11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test reportshouldbeasperIS13573:2011whichcoveredallsequence fortable2forterminationkitandtable3forstreightthroughjoint inclusive thermal & dynamic short circuittest, humiditytest, soil fog test.CrosslinkingshallbedoneoutsidefactorywithE-beam/ peroxidetechnology.ExtrusionprocessshallbeinhouseOEM withinsamevicinity.includingtestingetc.asrequiredoffollowing sizes. All as per pre approved by Engineer in-charge. For additional technicalparametersofproducts/work,referAnnexure\"A\" attached with this BSR .
8383 core 120/150/185 Sq.mm
8393 core 120/150/185 Sq.mm
8406.6 KV NGR Control Panel,3.81 Ohms with100 A, 10 Sec Capacitywithsupporting Structure for installation.Hence NGR of 3.81 Ohms is required with capacity of 1000 Amp 10 sec.Complete as per technical specifications and as directed by Engineer in charge.
841SITCofHT33KV,3Phase,50Hz,totallyenclosedmetalcladSF6 switchgearhavingrupturingcapacityupto630Amps,OutdoorNon ExtensibleFixedType(IP54),RMU(Ringmainunit)comprisingof manuallyoperatedLoadBreakSwitchandmanualchargingfixed-typeVacuumCircuitBreakerasperrequirement,insiderobotically welded stainless steel grade 304 (Non Ferrite Non Magnetic Grade) tankhavingofminimumthickness2mmwithIP67Degreeof ProtectionandenhancedBILof170kVpinternallytomanage voltagesurges.RMUshouldbeprovidedwithinternalbusbars,as wellasearthingbusbarsofelectrolyticgradecopper,padlock provisions&completewithallaccessories.TheRMUshallbetype testedforInternalarctestofAFLR25kA/1secfortankandcable chamber as per IEC62271-200. RMU shall have on-site-repair ability features such as site replaceable bushing/ coupling/ mechanism and gasrefillingatsite.Theearthingbusbarshallbeprovidedinside eachcablecompartmentforsolidearthingofcablesheilds.The outerhingedmaindoorshouldcoverentirefrontofswitchgear including cable doors for providing better ingress protection. The unit shallincludethefollowingwithallnecessarystandardfittingsas required at site.Load Break Switch module consisting of following accessories : 33kV,630AmpLoadBreakSwitchmoduleandintegratedearthing switch, both with full making capacity. ShortCircuitwithstandcapacity-25kA/3-sec,MakingCapacity– 62.5 kAp, Auxiliary contacts - 1NO + 1NC Fault Pass Indicator - 1 Nos,touch-proof screen separable termination kit (push on type) VCBBreakermoduleconsistingoffollowingaccessories:33kV, 630 Amp fixed-type Vacuum Circuit Breaker module for making and breakingoffaultcurrentalongwithdisconnector+EarthSwitchof full making capacity. Short time current breaking capacity - 25KA/ 3 sec, Making Capacity – 62.5kAp, Auxiliary contacts - 1NO + 1NC VCBoperatingsequencemustbeO-0.3Sec-CO-3Min-COand mechanical endurance confirms for minimum 10000 operations. touch-proof screen separable termination kit (push on type) Numericalbasedself-poweredOC+EFProtectionRelay,providing Over Current (min. setting 20%), Earth-Fault (min. setting : 10%) 03Nos50-100/1,2.5VAepoxyinsulated,RingCoreCTsfor protection(Acc.CL5P10),installedawayfrombushingstoprevent saturationofcore.(CTRatiomychangeaccordingtochangein Load) AllmodulesshouldhaveSuitablesitereplaceablecablebushings situatednotbeyond300mmfromcable-covertoalloweaseof access for installation/ testing/ replacement purposes. Cable covers with self-Interlocking mechanism between doors, earth switch, disconnector & VCB Capacitive voltage indication fixed type system (i) Capacitive voltage indication fixed type VPIS 28-45 kV (ii)OneNo.OperatingHandleforManualOperationandoneno. manometer (iii)SafetyInterlocksShallbeprovidedasperrelevantIEC/IS Standards and Manufacturer’s directions (iv) Above switchgear shall confirm to all relevant IEC/IS Standards. (v) Vacuum interrupter should be of same make as RMU (vi) Cable bushing should be replaceable at site. (vii)Minimum4moduleshouldaccommodateinonetanktoavoid multiple coupling at site.
842Non-ExtensibleType4wayRMUwith2no.VCB&2No.LoadBreak Switch
843Design,Manufacture,Supply,Installation, TestingandCommissioningofIndoortypePLC Panelofsizeapprox.800mmX500mmX 2000mm(LBH),Fabricatedoutofmin.2mm thickCRCAsheetcompletewithlatest configuration,necessaryprogrammingsoftware forPLC&SCADAandcomprisingofall accessories not limited to the following: DI 30No. DO 26No. AI 6No. AO 2No. MCB 16A DP 2No. MCB 6A DP6No. SMPS 100-240VAC/ 4.5A / 24 VDC 1No. Selector Switch (Auto/Manual) & Local / Remote2No.Control Relays1Lot Annunciatorwith24WindowsNOtoNCType MicroprocessorBased,WindowSize75*42mm, 110VAC, with1No.Electronic Hooter1No. Control Transformer 200VA1No. Emergency STOP Push Button1No. Panel Cooling Fan & Filter2No. Panel Light with Door Switch, 7W1No. Control Indication Lamp for 24VDC, 220VAC3No.Push Button3No. Power Wiring+Control Wiring + Control TB/ Fuse 2A,TB etc1Lot PanelHardware,lugs,terminations,ferruls, name plate Ect.1Lot UTILITY SOCKET 16A, 3 PIN2No. HMI Display 10 Inch, Colour1No. Isolators Dual Output, 24VDC1Lot
844Design,Manufacture,Supply,Installation, TestingandCommissioningofIndoortypePLC Panelofsizeapprox.800mmX500mmX 2000mm(LBH),Fabricatedoutofmin.2mm thickCRCAsheetcompletewithlatest configuration,necessaryprogrammingsoftware forPLC&SCADAandcomprisingofall accessories not limited to the following: DI 62No. DO 58No. AI 14No. AO 6No. MCB 16A DP 2No. MCB 6A DP6No. SMPS 100-240VAC/ 4.5A / 24 VDC 1No. Selector Switch (Auto/Manual) & Local / Remote2No. Control Relays1Lot Annunciatorwith24WindowsNOtoNCType MicroprocessorBased,WindowSize75*42mm, 110VAC, with1No.Electronic Hooter1No. Control Transformer 200VA1No. Emergency STOP Push Button1No. Panel Cooling Fan & Filter2No. Panel Light with Door Switch, 7W1No. Control Indication Lamp for 24VDC, 220VAC3No. Push Button3No. Power Wiring+Control Wiring + Control TB/ Fuse 2A,TB etc1Lot PanelHardware,lugs,terminations,ferruls, name plate Ect.1Lot UTILITY SOCKET 16A, 3 PIN2No. HMI Display 10 Inch, Colour1No. Isolators Dual Output, 24VDC1Lot
845Design,Manufacture,Supply,Installation, TestingandCommissioningofIndoortypePLC Panelofsizeapprox.800mmX500mmX 2000mm(LBH),Fabricatedoutofmin.2mm thickCRCAsheetcompletewithlatest configuration,necessaryprogrammingsoftware forPLC&SCADAandcomprisingofall accessories not limited to the following: DI 102No. DO 98No. AI 22No. AO 16No. MCB 16A DP 2No. MCB 6A DP6No. SMPS 100-240VAC/ 4.5A / 24 VDC 1No. Selector Switch (uto/Manual) & Local / Remote2No. Control Relays1Lot Annunciatorwith24WindowsNOtoNCType MicroprocessorBased,WindowSize75*42mm, 110VAC, with1No.Electronic Hooter1No. Control Transformer 200VA1No. Emergency STOP Push Button1 No. Panel Cooling Fan & Filter2No. Panel Light with Door Switch, 7W1No. Control Indication Lamp for 24VDC, 220VAC3No.Push Button3No. Power Wiring+Control Wiring + Control TB/ Fuse 2A,TB etc1Lot PanelHardware,lugs,terminations,ferruls, name plate Ect.1Lot UTILITY SOCKET 16A, 3 PIN2No. HMI Display 12 Inch, Colour1No. Isolators Dual Output, 24VDC1Lot
846SITCofIntelligentManageableEthernetSwitchesproviding24x 10/100/1000FastEthernetports-and2dualpurposeuplink (provisionforCopper/FibreGigaconnectivity)withLANbased Software.TheLANbasedS/Wsupportsenhancedintegrated security,includingNetworkAdmissionControl(NAC),advanced qualityofservice(QoS),availabilityandscalablemanagementto enable new converged applications
847Providing,installation,testingandcommissioningofONLINEUPS SYSTEM,SinglePhase230V,50Hzwith2hourbackupSMF battery bank as per specification
8482 KVA
849ProvidingandlayingStranded/FlexibleAnnealedeBarecopper conductor,XLPE/PVCinsulatedsuitablylaiduptogetheroverall polystertapedAl(innersheatedGISteelwireMylar/Drainwire) alongwithATCdrainwire,round/steelarmouredoverallPVC sheathed (ST-1) overall screenedCore armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009.
85024 CORE, 1.0 sq. mm.
8514 CORE, 1.0 sq. mm.
852ProvidingandlayingStranded/FlexibleAnnealedBare copperconductor,XLPE/PVCinsulatedsuitablylaidup together overall polyester taped Al (Mylar tape wrapped) along with ATC Drain wireoverall PVC sheathed (ST-1) overall screenedPair armoured instrumentation Cables generally confirming to PAS 5308- Part-2-2009. (2 Pair * 0.75SQMM)
853Providing,Installation,TestingandCommissioningofUltrasonic LevelTransmitter:Principle:TimeofFlight/SensorMOCPP/ PowerSupply:24VDC/Output:4-20mA/Display:Integral displayforprogrammingandDisplayReading/IP66/Accuracy ±1%
8540 - 5 Mtr.
855Providing,Installation,TestingandCommissioningofPressure Transmitter : Range:0-10Bar / Power Supply:24 V DC / Output: 4-20mAwithHART/Diaphragm:SS316L/ProcessConnection: 1/2 \"NPT (M) / Accuracy: 0.15% Protection: IP67
856Providing,installation,testingandcommissioningofDiaphragm Type Pressure Gauges Dial size 150 mm glycerin filled shatterproof glass,Overrangeprotection:125%ofmaximumpressure,Material ofsensorandotherwettedparts:SStype316,Housingmaterial: Die cast aluminum
857Providing, installation, testing and commissioning of Diaphragm type Pressure Switches Sensing Element: Bellows / Diaphragm, Material ofsensorandotherwettedparts:SStype316,Housing:Diecast aluminum,Switchtype:Microswitch,Repeatability:±1%ofspan, Switch Contacts: 2 NO + 2 NC
858Providing,installation,testingandcommissioningofLevelSwitch( Conductivity)ConductivityProbes,Probeinsulation:Teflon,Probe head protection class: IP 65 of IS 13947 Part I, Probe head housing material: Aluminum
859Rigid for lengths ofup to 3 Mtr.
860SITC ofUltrasonic Level Transmitter suitable for measuring water levelin reservoir, powered by solar panel with minimum 48 power back up or internal installed battery ( 5 years battery life with replacement warranty), with out put as GSM/GPRS + data logger , Sensor Material: PP, accuracy +/_ 0.2 %,as per detailed Technical specification, scope of work and direction of Engineer in charge.
861Measuring range 0.0 to 6.0 mtr
862Supply, Installation, testing and commissioning of SCADA System at MasterControlCentrecompletewithPCserver,monitor, communication modules, printers, 2 Nos. of 60\"LED Display of latest resolution and configuration, 4 Nos of 32\"\" Operator console ( 1 No. of Engineering, 1 No. of operator console, 1 No. of Historical and 1 No. of Web Server) including control desk, chairs, storage racks etc., requiredhardware,softwarecompletewithallaccessoriesandin line with Technical Specification.
863Providing,installation,testingandcommissioningofONLINEUPS SYSTEM, 3 Phase 415 V, 50 Hzwith2 hour backup SMF battery bank as per specification
86410KVA
865LocalDataLogger-PCbasedDataAcquisitionSystemwithSAM WILicenseSoftwaresuitableforStoring,Logging,Reporting, PrintingdatafromaboveofferedAnalysers.PCwithspecifications as under: Intel Core i5 5th Generation Processor, 8 GB RAM, 1 TB HDD+250 GB SSD, CD/DVD Combo Drive, 32\"Monitor, Minimum 6 USBports(USB3.0/2.0),WINDOWS-7orhigherCompatiple Operating System, standard keyboard, mouse with pad and with A3 & A4 Color Laser printer.
866CentralDataLogger-PCbasedDataAcquisitionSystemwithXR Premium License Software suitable for Storing, Logging, Reporting, Printingdata,Validationandcommunicatingwithaboveoffered LocalDAS.PCwithspecificationsasunder:IntelCorei55th GenerationProcessor,8GBRAM,2TBHDD+250GBSSD, CD/DVDComboDrive,32\"Monitor,Minimum6USBports(USB 3.0/2.0),WINDOWS-7orhigherCompatipleOperatingSystem, standardkeyboard,mousewithpadandwithA3&A4ColorLaser printer.
867Supply, installation, testing and commissioning of GSM /GPRS/ Cloudbased data transmitter for Bulk Flowmeter (woltman Magnetic Pulse Output only ), Battery Powered -3VDC to12VDC ,Model no- CT-DL-V1.0-100784, battery life 3-5 Years, Inbuild Memory fuction upto 2gb micro SD card supportedto stroe the data in the absense of availabe mobile network,(1 no Data transmit in aday on cloud system), Encloser- ABS Protection-IP67/68,Operating tempreature -50-55 Deg. C. The VTC Inlet Flow Data shall be transmitt to the Respective MCC ROOM.
868Supply,Installation,TestingandComissioningofISOcertified companymadeAirCooledHiWallsplittypeAirconditionerswith lateststarratingsystemasperBEEamendeduptodatecomplete withIndoorunit(IDU),Outdoorunit(ODU),surface/concealed copperRefrigerantpipingwithinsulation(closedcellelastomeric nitrile rubber tubular pipe section)upto 3 Mtr (IDUto ODU), copper powercableupto3.5Mtr(IDUtoODU),R-32/R-410/R-407Green Refrigerant,wirelessRemotecontrol,suitableforworkingbetween 180-260Vwithlow&highvoltagecutoffand50hz,1phaseAC supplycapableofperformingcooling,dehumidification,air circulation of following capacitywith Scroll / rotarycompressor. Min 5 year OEM warranty both compressor and PCB. NABL accredeated asperIS/ISO/IEC17025standards/CPRI/ERDAlabtesting reportsasperIS1391(Part-2)2018withOEMcertificatemust submittedtoengineerin-charge.Allasperpreapprovedby Engineer in-charge.All asper pre approvedbyEngineerin-charge. Foradditionaltechnicalparametersofproducts/work,refer Annexure \"A\" attached with this BSR . Non InvertorType1.8/2.0TRwith3starratingofBEE(ISEERnot less then 3.5 )
869Cost for basic service charges, Administration and Management, running of office, staff quarters, comprehensive Operation, Maintenance and Repairs including Preventive Maintenance, IEC activities as per scope of work, cost of material required for maintenance & repairs, cost of lubricants, saltf for producing chorine, consumables spare parts (if the spare parts supplied to PHED are used in emergency) as per scope of work & items & conditions of contract no, amt will be paid for O&M in DLP
870For the 1st year of O&M after DLP
871For the 2nd year of O&M after DLP
872For the 3rd year of O&M after DLP
873For the 4th year of O&M after DLP
874For the 5th year of O&M after DLP
875For the 6th year of O&M after DLP
876For the 7th year of O&M after DLP
877For the 8th year of O&M after DLP
878For the 9th year of O&M after DLP
879For the 10thyear of O&M after DLP

AI Tender Summary

OUR REF NO 49223408
AUTHORITY Government Departments
TENDER VALUE 1692.30 Crore
LAST DATE 16-09-2026
Authority
Authority Name Public Health Engineering Department
Work Description Tender for Work of Drinking Water Supply Project for 1473 villages of Chittorgarh, Pratapgarh, Rajsamand & Udaipur District from Jakham Dam under Jal Jeevan Mission (Package-1 :- WTP, IPS-1 to IPS-6, CPS-01 to 19 including complete works of these CPS, CD -VD & Civil works for 93 villages of Chhoti Sadri block of Pratapgarh, 707 villages of 7 blocks of Chittorgarh district) under JJM With Operation and Maintenance for Ten (10) Years including Defect Liability Period of One (1) Year on Hybrid Annuity Model (HAM).
Basic Detail
Tender No ACEP-UDR-NIT No. 09/2024-25
Bidding Type Tender
Location
City chittorgarh
State Rajasthan
Key Dates
Publish Date 16 Jun 2026
Submission Date 16 Sep 2026
Open Date 17 Sep 2026
Finance
Tender Value 1692.30 Crore
Tender Fee 2500
EMD 8.46 Crore
Exemption Available
Document List
b1f65e25-defd-477c-b58f-5a5770c3c0a0.html
09.pdf
BOQ_841451.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jun 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 28, 2025
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Sep 08, 2025
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 28, 2025
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Feb 16, 2026
18:00 IST

Corrigendum-4 Issued

Clarifications on tender conditions and amendments issued.

Completed
Dec 29, 2025
18:00 IST

Corrigendum-5 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 27, 2025
18:00 IST

Corrigendum-6 Issued

Clarifications on tender conditions and amendments issued.

Completed
Apr 16, 2026
18:00 IST

Corrigendum-7 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 18, 2026
18:00 IST

Corrigendum-8 Issued

Clarifications on tender conditions and amendments issued.

Completed
Apr 16, 2026
18:00 IST

Corrigendum-9 Issued

Clarifications on tender conditions and amendments issued.

Completed
Feb 16, 2026
18:00 IST

Corrigendum-10 Issued

Clarifications on tender conditions and amendments issued.

Completed
Dec 29, 2025
18:00 IST

Corrigendum-11 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 27, 2025
18:00 IST

Corrigendum-12 Issued

Clarifications on tender conditions and amendments issued.

Completed
Sep 08, 2025
18:00 IST

Corrigendum-13 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 18, 2026
18:00 IST

Corrigendum-14 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jul 28, 2025
18:00 IST

Corrigendum-15 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jun 18, 2026
18:00 IST

Corrigendum-16 Issued

Clarifications on tender conditions and amendments issued.

Completed
Apr 16, 2026
18:00 IST

Corrigendum-17 Issued

Clarifications on tender conditions and amendments issued.

Completed
Feb 16, 2026
18:00 IST

Corrigendum-18 Issued

Clarifications on tender conditions and amendments issued.

Completed
Dec 29, 2025
18:00 IST

Corrigendum-19 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 27, 2025
18:00 IST

Corrigendum-20 Issued

Clarifications on tender conditions and amendments issued.

Completed
Sep 08, 2025
18:00 IST

Corrigendum-21 Issued

Clarifications on tender conditions and amendments issued.

Completed
Sep 16, 2026
18:00 IST

Corrigendum-22 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 57 days
Jul 28, 2025
18:00 IST

Corrigendum-23 Issued

Clarifications on tender conditions and amendments issued.

Completed
Sep 16, 2026
18:00 IST

Corrigendum-24 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 57 days
Sep 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 57 days
Sep 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 58 days

Tender Documents

Download All (ZIP) ↓
html

b1f65e25-defd-477c-b58f-5a5770c3c0a0.html

pdf

09.pdf

xls

BOQ_841451.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders