| 1 | Building Items (Part A) |
| 2 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster incl. disposal of rubbish to the dumping ground within 50mtr lead |
| 3 | Renewing glass panes, with putty and nails wherevernecessary :Float glass panes of thickness 4 mm |
| 4 | Earth work in excavation by mechanical means (HydraulicExcavator )/ manual means in foundation trenches or drains(not exceeding 1.5 m in width or 10 sqm on plan) includingdressing of sides and ramming of bottoms, lift upto 1.5 m,including taking out the excavated soil and depositing andrefilling of jhiri with watering & ramming and disposal ofsurplus excavated soil as directed with in a lead of 50 meter.All kinds of soils |
| 5 | Providing and laying in position cement concrete includingcuring, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 6 | Random Rubble stone masonry for with hard stone infoundation and plinth in Cement Sand mortar above 30 CMthick wall in:Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
| 7 | Random Rubble stone masonry with hard stone insuperstructure above plinth level and upto five level above30cm. thick walls in : Cement Mortar 1:6 ( 1-Cement : 6-Sand). Wall upto 30cm. and less thickness. |
| 8 | Providing and laying damp-proof course with cement concrete grade M-150 (1 : 2 : 4) mortar prepared with 1% solution of water-proof compound complete as per specification . 50mm thick. |
| 9 | Brick work with mechanised autoclaved flyash lime bricksconforming to IS: 12894 :2002 of class designation 100 insuperstructure above plinth level upto floor V level in. Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 10 | Stone slab roofing on ground floor with fine grained stoneslab from approved quarry including filling of joints ofparapet and slab on both sides in cement sand mortar 1:4,with ceiling pointing in cement sand mortar 1 : 3 complete asper specification and instruction of Engineer In Charge |
| 11 | Plaster on new surface on walls in cement sand mortar 1:6including racking of joint etc. complete fine finish20 mm thick |
| 12 | Providing and fixing 1st quality standard white, grey, ivory,fume red brown, light green, light blue and other light shadesglazed tiles confirming to IS : 13753 & IS :15622 of size200mm x 300mm in walls, floors, steps, pillars etc. laid on abed of neat cement slurry finished with flush pointing in thewhite cement mixed with pigment to match the shade of thetile complete (excluding the cost of cement plaster on wallsand pillar). |
| 13 | Providing and fixing 1st quality MAT finished ceremic tilesize 300x300mm confirming to IS : 13755 and IS : 15622colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed |
| 14 | Making of drip course (Tapka) in cement sand mortar 1:6 width upto 40 mmand 10 mm thick as per approved design |
| 15 | Supplying and fixing stone lintels/bed plates of approvedquarry rough dressed in cement mortar 1:4 : Upto 15 cm. thick. |
| 16 | Distempering with 1st quality acrylic washable distemper(ready mixed) of approved manufacturer and of required shade and colour completeincluding all scaffolding as permanufacturer\"s specification.Two or more coats on new work including prepartion of basewith primer, putty, lippy etc complete in all respect. |
| 17 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: Old work (one or more coats) including scrapping surface and necessary repairs. Colour Change |
| 18 | Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding.New work (Two or more coat applied @ 1.67 ltr/10 sqm overand including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ). |
| 19 | Painting exterior surface of Wall with 100% acrylic exteriorpaint of approved brand and manufacture to give an evenshade with two or more coats including prepartion of basewith sand papering, primer, putty, etc complete in all respectincluding scaffolding and safety provision Old Work |
| 20 | Providing and fixing T-iron frames for doors, windows andventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 21 | Providing and fixing M.S. sheet 1mm thick single leaf doorshutter in angle iron frame 35x35x5mm suitabilly diagonallybraced with 25x3mm flat iron above and below lock rail ofsize 50x5mm beading extra including all fittings, as perdirection of Engg. incharge but excluding cost of chowkhats:including two coats of anit-corrosive red oxide primer paint |
| 22 | Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :Windows side hung /Ventilators top or centre hung (openable) Deduct for pin heades 4mm thick glass panes is used |
| 23 | Providing and fixing Square bars or other flat welded to window, ventilatiors etc. |
| 24 | Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. |
| 25 | Painting with synthetic enamel paint of approved brand andmanufacture to give an even shade : Two or more coats on new work |
| 26 | Painting with synthetic enamel paint of approved brand andmanufacture to give an even shade : ne or more coats on old work. |
| 27 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20mm nominal size). |
| 28 | Repair to damaged RCC slabs, beams and columns etc forstrengthening with cement mortar 1 : 2 in following steps :- (i) Choping losse and cracked concrete to required depth,cleaning the exposed surface of steel and concrete with wirebrush and sand papering , cleaning of concrete surface withwater as necessary and getting dried.(ii) Applying Epoxy primer on the exposed steel bars.(iii) Applying Epoxy hardener and resin mix (as permanufectured\"s specification) on concrete and steel bars with brush.(iv) Speading dry cement mortar 1 : 2 mix over epoxy treated wet surface and allow it to dry for one day.(v) Plastering the surface with cement sand mortar 1 : 3 uptodepth of 30mm complete.(vi) Cure the plastered surface for 15 days, All work including scaffolding etc. complete in all respect. |
| 29 | Providing and applying white cement based putty overplastered surface to prepare the surface even and smoothcomplete New Plastered Surface (three or more coats) |
| 30 | Repair of existing steel glazed doors, windows and ventilator,MS sheet door,garage doors,compound wall gates etc by welding drilling complete include cost of welding rods and hire charge of welding machine & TP etc complete. |
| 31 | Providing & laying broken glazed titles on roof ( brokenglazed tiles not less than 9 Kg/Sqm) on top of hot bitumen @1.7 Kg/Sqm. (1.40 Kg of VG-40 (30/40 )grade and 0.30Kg/Sqm. Of VG-10 (80/100) grade) and joints filled withcement mortar 1 :2 (1 cement:2 marble dust mixed with waterproofing compund all complete as per direction of Engineerin- charge. |
| 32 | Supplying and fixing in walls machine cut and polished stone shelves, tands and in CM 1:3 with machine cut edges : Sand or other approved stone 50mm thick. |
| 33 | Structural steel work riveted, bolted or welded in built upsections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: |
| 34 | Grading roof for water proofing treatment with waterproffing compound Cement mortar 1:4 (1cement : 4 coarse sand) |