| 1 | SH: A. Construction of Classroom Block cum Academic Building (G + 2) |
| 2 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. a) All kinds of soil. |
| 3 | Fillingavailableexcavated earth(excludingrock) intrenches, pinth, sidesoffoundationsetc. in layers not exceeding 20 cm in depth, consolidation each deposited layer by rammingand watering, lead upto 50mand lift upto 1.5m. |
| 4 | Supplying and filling in plinth with sandy soil under floors including, watering,ramming consolidating and dressing complete. |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level: a) 1:4:8 ( 1 Cement: 4coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 6 | Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc.by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).Note: Truck Mounted rotary/TMR/ Tubewell boring machine shall not be used . a) 450 mm diameter |
| 7 | Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : a) 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size). |
| 8 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level upto floor five level excluding cost of centering,shuttering, finishing and reinforcement : a) 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 9 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centering, shuttering, finishing and reinforcement with a) 1:1.5:3 ( 1 cement : 1.5 c/sand : 3 graded stone aggregate 20mm. Nominal size). |
| 10 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. a) Thermo Mechanically Treated Bars |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 12 | a) Foundations, footings, bases of columns, etc. for mass concrete. |
| 13 | b) Suspended floors, roofs, landings, balconies and access platform: floors etc. upto 200 mm in thickness |
| 14 | c) Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 15 | d) Lintels, beams, plinth beams, girders, bressummers and cantilevers, with water proof ply 12mm thick. |
| 16 | e) Stairs, (excluding landings) except spiral-staircases. |
| 17 | Brick work with Ist class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand). |
| 18 | Half brick masonrywith 1st class common burnt clay F.P.S. (non modular) bricks in foundation and plinth in:Cement mortar 1 : 3 (1 cement : 3 coarse sand) |
| 19 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : a) Local best quality Teak wood |
| 20 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. Local best quality Teak wooda) 35 mm thick shutters |
| 21 | Providing and fixing bright finished brass door latch with necessary screws etc. complete : 300x16x5 mm |
| 22 | Providing and fixing bright finished brass tower bolts (barrel type)with necessary screws etc. complete : |
| 23 | a) 250 X 10mm. |
| 24 | b) 150x10 mm |
| 25 | Providing and fixing bright finished brass handles with screws etc. complete : |
| 26 | i)125 mm |
| 27 | ii)100 mm |
| 28 | Providing and fixing bright finished brass casement window fastener with necessary screws etc. complete. |
| 29 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10 x 15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) |
| 30 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : a)125x85x5.5 mm (heavy type) |
| 31 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. (a) Fixed to openings /wooden frames with rawl plugs screws etc. |
| 32 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 33 | Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar bent to shape with hooked ends in R.C.C. slabs, beams during laying including painting the exposed portion of loop, all as per standard design complete. |
| 34 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of T-iron 40x40x6mm with 40mm dia, steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 35 | Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete: 40mm thick with 20mm nominal size stone aggregate. |
| 36 | Marble stone flooring with18mm thick marble stone (sample of marble shall be approved by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with : Makrana white second quality. |
| 37 | Chequered precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles includingrubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). (a) Medium shade using 50% white cement 50% grey cement |
| 38 | Steel work in built up tubular(round, square or rectangular tubes etc.) trusses etc., including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete.Electric resistance or induction butt welded tubes. |
| 39 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with: i) Precoated galvanised iron profile sheets0.50 mm thick |
| 40 | Providing and fixing precoated galvanised steel sheet roofing accessories , Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete :a)Ridges plain (500 - 600mm). (i)Precoated galvanised iron profile sheets0.50 mm thick |
| 41 | P/F at all height false ceiling including providing and fixing of frame work made of special sections, power pressed from M.S. sheet and galvanised with zinc coating of 120 gms/ sqm (both sided inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm diax50mm long with 6mm dia bolts,other flange of cleat fixed to the angle hangers of 25x25x0.55mm of required length with nuts and bolts of required size and the other end of the angle hanger fixed with intermediate G.I. channels 45x15x0.9mm running at the spacing of 1200mm centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre, shall be fixed in a direction perpendicular |
| 42 | to G.I. intermediate channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre, with 25mm long drive-all screws @ 230mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers,cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, and specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I, |
| 43 | 12 mm cement plaster of mix: 1:4 (1 cement : 4coarse sand) |
| 44 | 15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat ofneat cement on the rough side of single or half brick wall. |
| 45 | Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to preparethe surface even and smooth complete. |
| 46 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 47 | (a) With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 48 | (b) With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 49 | Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : |
| 50 | (a) Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture |
| 51 | (b) Two or more coats applied @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @0.75 ltr/10 sqm. |
| 52 | Applying priming coat:-With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works:- |
| 53 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. |
| 54 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. |
| 55 | Brick edging 7cm wide 11.4 cm deep to plinth protection with 1st class common burnt clay F.P.S (non modular) bricks including grouting with cement mortar 1:4 (1 Cement mortar :4 fine cement) |
| 56 | Providing and fixing on wall face unplasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 75 mm diameter |
| 57 | Providing and fixing unplasticized -PVC pipe clips of approved design to unplasticized - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4(1 cement: 4 coarse sand) and making good the wall etc. complete. 75 mm |
| 58 | SH: B. Providing Water supply and sanitary installation. |
| 59 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 60 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 61 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - |
| 62 | (a)1:4:8 ( 1 Cement: 4coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 63 | (b)1:2:4 ( 1 Cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 64 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work upto plinth level : a)1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 65 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with: a) 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggrt. 20 mm. nominal size). |
| 66 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. a)Thermo Mechanically Treated Bars |
| 67 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 68 | a) Foundations, footings, bases of columns, etc. for mass concrete. |
| 69 | b) Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 70 | c) Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 71 | d) Suspended floors, roofs, landings, balconies and access platform. |
| 72 | Brick work with 1st class common burnt clay F.P.S. (non modular) bricksin foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 73 | Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricksin superstructure above plinth level upto floor V level in Cement mortar 1 : 3 (1 cement : 3 coarse sand) |
| 74 | 15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat ofneat cement on the rough side of single or half brick wall. |
| 75 | Providingand fixing water closet squatting pan (Indian type W.C. pan ) with 100 mmsand cast Iron P or S trap, 10 litre low levelwhiteP.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580 x 440 mm with integral type foot rests |
| 76 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid. |
| 77 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: a) White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 78 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors whereverrequired : a)Single half stall urinal with 5 litre P.V.C. automatic flushing cistern |
| 79 | Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required : a)Single half stall urinal with 5 litre P.V.C. automatic flushing cistern |
| 80 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. a) 32 mm dia |
| 81 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm |
| 82 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. a) 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms. |
| 83 | Providing and fixing toilet paper holder: C.P. brass |
| 84 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 85 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : a) 15 mm nominal bore |
| 86 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931: a) 15 mm nominal bore |
| 87 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : a) 25 mm nominal bore |
| 88 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : a) 25 mm nominal bore Vertical Code |
| 89 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. |
| 90 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the wall etc. a) 32 mm nominal outer dia Pipes |
| 91 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work: a) 75 mm nominal outer dia Pipes |
| 92 | Providing and fixing uplasticised PVC connection pipe with brass unions :30 cm length: 20 mm nominal bore |
| 93 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 94 | SH:C. Providing Internal Electrical Installation |
| 95 | Wiring for light point/Fan point/ exhaust fan point/call bell point with 1.5 mm 2 FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit modular type switch size G.I box and earthing the point with 1.5 mm 2 FR PVC insulated copper conductor single core cable etc, as reqd |
| 96 | 1. Group - A |
| 97 | 2. Group - B |
| 98 | 3. Group - C |
| 99 | Wiring for light point / power plug with 2x4mm 2 FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit along with 1. no. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc. as required |
| 100 | Wiring for circuit/sub-main wiring along with earth wire with (the following sizes of) PVC insulated copper conductor single core cable in surface/receesed PVC conduit etc as required |
| 101 | 2 x 1.5 mm2 + 1 x 1.5 mm2 earth wire |
| 102 | 2 x 2.5 mm2 + 1 x 2.5 mm2 earth wire |
| 103 | 2 x 4 mm2 + 1 x 4 mm2 earth wire |
| 104 | 2 x 6 mm2 + 1 x 6 mm2 earth wire |
| 105 | S/F (following size/ modules,)G.I box along with modular base and cover plate for modular switch in recess as required. |
| 106 | 4 module (125mm x 75 mm ) |
| 107 | 12 module (200 mm x 150 mm) |
| 108 | Supply and fixing (following modular type switch/ socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as req.switch box/ cover i/c connection etc as required. |
| 109 | 5/6 amps switch |
| 110 | 15/16 amps switch |
| 111 | 3 pin 5/6 amps socket outlet |
| 112 | 6 pin 15/16 amps socket outlet |
| 113 | S/F Trim Clipon LED PanelSurface / recess Mounted panel 18 W LED circular Havells |
| 114 | S/F Trim Clipon LED PanelSurface / recess Mounted panel 24 W LED circular Havells |
| 115 | S/F LED flood light -50 W (Havells) |
| 116 | S/F 16 W. LED Lamp (Philips) |
| 117 | S/F brass batten/angle holder i/c connection etc. as reqd. |
| 118 | S/F 48” sweep (1200 mm) A.C. ceiling fan complete with down rod, canopy, 3 (three) blades but without regular etc as reqd. (Make Bajaj / Usha or similar) |
| 119 | S/F modular stepped type electronic fan regulator on the existing modular plate switch box i/c connection but excluding modular plate etc. as required. |
| 120 | S/F 380mm sweep exhaust fan complete with all accessories i/c connection etc as required. |
| 121 | S/F 8 way, (2+8 way) single door single pole and neutral, prewired, sheet steel MCB distribution board, 240 V on surface/ receesed complete with loose wire box, terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnection, including powder coat painting, earthing etc as req.(but without MCB/RCCB/Isolator). |
| 122 | S/F (following way,) single/double pole and neutral, sheet steel MCCB distribution board, 240V on surface/ recessed complete with tinned copper bus bar nuetral bus bar,earth bar, din bar, detachable gland plate, interconnection, phosphatized and powder painted including earthing etc as reqd(but without MCB/RCCB/isolator). |
| 123 | 4 way double door |
| 124 | Supplying and fixing 5 amp to 32 amp rating 230 V B series MCB for lighting and other load for (following poles) in the existing MCB DB complete with connection testing and commissioning etc. as reqd. |
| 125 | Single pole and neutral |
| 126 | S/F (following rating) double pole 240 V isolator in the existing MCB DB complete with connection, testing and commissioning as reqd. |
| 127 | 40 amp |
| 128 | 63 amp |
| 129 | S/F single pole blanking plate in the existing MCB DB Complete etc as req. |
| 130 | 16 sq.mm ISI marked,FR PVC insulated single core copper conductor cable |
| 131 | S/F 1.5 tone capcity split type Air conditioner, (Diamond, 3 star, 5G 29, G-SC 18 FD 3WJH) Complete (without voltage stabilizer) |
| 132 | Earthing with copper plate 600 mm x 600 mm x 6 mm thick i/c accessories and providing masonary enclosure with cover plate having locking arrangment and watering pipe etc. (but without charcoal or coke and salt) as reqd, |
| 133 | Extra for using salt and charcoal for pipe earth electrode as reqd. |
| 134 | P/L earth connection from earth electrode with 4 mm dia copper wire in 15 mm dia G.I. pipe as reqd. |
| 135 | Fabrication of control panel Board by 16 guage steel sheet, along with components mounting making strip wiring auxiliary components wiring all over the panel i/c fixing charge, painting etc. as reqd. |
| 136 | indicating lamp |
| 137 | Voltmeter Range 0-500 volts |
| 138 | ammeter Range 0-200 Amps |
| 139 | Current transformer coil range 0-200 amp |
| 140 | Hinges for panel door |
| 141 | Panel internal power wiring by 40 x 6 mm copper strips |
| 142 | P/F MV danger notice plate of 200 mm x 150 mm made mild steel at least 2 mm thick and vitreous enameled white on both sides and with inscription in single red color on front side as reqd. |
| 143 | Providing and fixing (following capacity TP & N) dis-connector fuse switch unit inside the existing cubicle panel board with ISI marks HRC fuses including drilling holes in the cubicle panel board, making connection ar reqd. |
| 144 | 100 amp.TP & N |
| 145 | P/F 125 amp, TPN stand ground on load change over switch (compact design) 415/500V including connection etc as reqd |
| 146 | Providing and fixing (following rating and breaking capacity) MCCB in existing cubical panel board with ISI marks HRC fuses including drilling holes in the cubical panel board, making connection as reqd. |
| 147 | 100 amp,10KA |
| 148 | S/F (following rating) four pole 240 V isolator in the existing MCB DB complete with connection, testing and commissioning as reqd. |
| 149 | 63 amp. |
| 150 | S/F 100 amp 500v porcelian fuse unit (Kit kat) |