Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stoney earth and earth mixed with small size boulders SS 20B and Sand, silt or other loose soil, wet sand, silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water wherever necessary refilling the sides of foundation with excavated soil other than sand in layers of 15cm thick well rammed and completed, cleaning and levelling the site etc., complete - Footings- First Depth Upto 2.00M |
| 2 | Supplying and filling the basement with Stone Dust Layer of not more than 15cm thick including watering with all layers and consolidation complying with standard specification including cost and conveyance of Gravel at site and all labour charges and all other incidential charges etc., complete as per Standard Specification |
| 3 | Plain Cement concrete 1:4:8 (one cement, four sand, eight aggregate) using 40mm gauge handbroken granitestone jelly for foundation including dewatering if foundnecessary and laid in layers of not more than 15 cmthick and compacted,etc., complete complying withstandard specfication. |
| 4 | Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS standards. (No separate payment will be made by the Department for the excess usage of materials) -Upto Basement |
| 5 | upto basement |
| 6 | Ground floor |
| 7 | Supply and fabrication of steel required for all RCC items of works involved in the schedule, cost of steel at site fabrication, labour charges for cleaning the rods straightening, cutting, bending, tying grills, including overlapping to the required length whenever necessary and placing the reinforcement in position as as per design given and specified in the drawings, including cost of binding wire, provision of spacer bars, cover blocks and all other incidental charges etc complete as per standard specification |
| 8 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation |
| 9 | Squre colomn |
| 10 | Circular column |
| 11 | Grade beam |
| 12 | Plain surface |
| 13 | Brick work in CM 1:5 (one cement & Five sand) using II class ground moulded bricks of size 9\"X43/8\"X 23/4\" standard specification including finishing, curing, etc., complete complying with standard specification (Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost) |
| 14 | upto basement |
| 15 | Ground floor |
| 16 | Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 25GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with spag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown olour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the executive Engineer before use on work |
| 17 | Supplying and fixing UPVC (Un-Plasticized PolyvinylChloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work |
| 18 | Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug |
| 19 | Supplying and fixing of rolling shutters shall be pull and push type (Mannually operated) made of 18G/3\" lathe sections which consist of five main parts such as curtain, lock plate, guide channels rollers and hood cover. These five main parts are made out of special components detailed below: curtain shall be of 18G/3\" lath sections cut to required size and filled with heavy cast iron / MS clips. For 8\"0\"(2.45m) high rolling shutter lath sections provided shall be not less than 37 numbers. Lock plate shall be 10G MS sheet and attached to the side brackets with 20mm square bar.Side brackets shall be of 10G MS plate and cast iron \"U\" clamps shall be rivetted to the side brackets. Roller shall be of heavy cast iron pullies fitted with heavy duty \"C\" class 40mm steel pipe and high tensile high carbon coil springs. 2 springs shall be supplied. Side brackets shall be of 10G MS plate and cast iron \"U\" clamps shall be rivetted to the side brackets. Hood cover shall be of 0.8mm CRCA sheet reinforced with 25mmx25mmx3mm MS angle or gate channel. The rolling shutter in addition to the above should have pulling hook and shall be coated on exposed area with heavy coat of red oxide primer etc., complete. |
| 20 | Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding, grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification. |
| 21 | Supply and fixing of M.S trusswith one coat of Red oxide with Primer including all costs such as welding, grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification. |
| 22 | Fabricating supplying and fixing of pre painted galvanized iron sheets with the following specification. The materials should be of PPGI tile profile with a red colour or any other approved design 0.47 mm thick 24 guage having width 1050 mm. The sheet should be G.I.base pre painted hot dipped galvanized iron sheet and to be fixed with shelf tapping screws,plastic washer.The washer and screws to be fixed by using minute power machine drilled with out damaging the sheets paint coating to be regular modified polyster coat with zinc coating of Z 120 GSM paint thickness the finish should be terra cotta finish like malabar mangalore tiles finish optional matt finish. The sheet to be fixed with making suitable corrugated,cutting the sheet in to the required ssize and making ornamental designs as per the site condition and as directed by the departmental officers. |
| 23 | Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being \"32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers.etc., complete as per standard specification. |
| 24 | Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One Cement add three sand) 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete as per standard specification. |
| 25 | Special ceiling plastering in all floors and finishing the exposed surface of RCC items of work such as slab, beam, sunshade, facia, canopy slab, staircase waist slab, landing slab etc., with cement mortar 1:3 (One cement and three sand) 10mm thick including hacking the surfaces and providing cement mortar nosing, beading for sunshade, staircase, step, landing slab etc., including neat finishing and curing etc., complete complying with standard specification and as directed by the departmental officers. |
| 26 | Plastering with cement mortar 1:5 (One cement and five sand) 12mm thick in all floors including cost and conveyance of all materials to site etc,complete as per standard specifications |
| 27 | Dadooing walls withGlazed tiles of sizes 305mm X200mm X 6mm size of approved make and quality and colour Set in cement mortar 1:2 (one cement, two sand) over 10mm base layer plastering and pointing with white cement neatly as directed etc., complete as per standard specification |
| 28 | Paving the floor with design Antiskid ceramic tiles (colour and shade as directed) of size 305 mm x 305mm x 6 mm in all floors over a base layer of cement mortar 1:3 (one cement and three sand ) 20mm thick laid in-situ and pointed with same coloured cement etc, complete as per standard specification. |
| 29 | Paving the floor with design Rajasthankotta tiles (colour and shade as directed) of size 610 mm x 610mm x 20mm in all floors over a base layer of cement mortar 1:3 (one cement and three sand ) 20mm thick laid in-situ and pointed with same coloured cement etc, complete as per standard specification. |
| 30 | Providing granolithic floor finish of the following thickness with plain cement concrete 1:2:4 (One Cement, Two sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panellingwherever necessary and as directed by the departmental officers) |
| 31 | Plain Cement Concrete 1:2:4 (one cement, two sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers. with out Vibrator |
| 32 | Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. |
| 33 | Painting the new iron work with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat and including cost of painting materials, brushes, putty, preparation of surfaces and scaffolding charges etc., complete complying with standard specification and as directed by the departmental officer. |
| 34 | Supplying and filling the basement with Gravel filling in layers of not more than 15cmthick well rammed watered and compacted - etc., complete complying with standard specification. |
| 35 | Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete |
| 36 | Supplying and fixing in position best quality approved make white glazed earthenware wash hand basin of size 550 X 400 mm with a pair of cast iron brackets, including cost of 15mm diametre brass chromium plated piller tape,32 mm diametre C.P. Waste union, 32 mm diametre P.V.C. waste pipe with rubber plug and chain, 15mm diametre G.M.wheel valve, 15mm dia brass nipple, 15mm dia nylon connections etc., including fixing the wash hand basin in the wall in position with a pair of C.I. brackets with teak wood plugs and screws and giving necessary water supply connection and paintiung the brackets with two coats of paint over a primimg coat of anticorrosive paint including testing for leackage etc., complete complying with standard specifications |
| 37 | Supplying and fixing in position Indian water closet of size 580 X 440mm, white glazed earthen ware of approved quality with \"P\" trap or \"S\" trap confirming to IS:2556 -Part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete1:2:5 ( one part of lime, two parts of sand and five parts of brick jelly) 100mm thick and finishing the top to required slope and including giving necessary connection to cast iron soil pipes/ PVC pipes by dismandling brick masonry, reinforced cement concrete roof/floor slab and making good the disturbed portion to original condition without leakage etc., complete complying with standard specifications and as directed by the departmental officers. |
| 38 | Supplying and fixing in position White Glazed European Water Closet of best quality and approved make with 100mm \"P\" os \"S\"\" trap with Double flapped rigit P.V.C. seat cover with C.P. brass hinges with 12.5 litres PVC Low Level Flushing Tank with all internal fittings etc., complete complying with standard spoecifications,labor inclusive of fixing lowlevel flushing tank. |
| 39 | Supplying and fixing in position indian make bewelled edge mirror of approved quality and brand of size 600 X 450mm wth necessary plastic back, PVC frame with bottom stand of approved colour with brass screws,rawal plugs etc., complete complying with standard specifications. |
| 40 | Supplying and fixing in position C.I.Manhole covers (light or heavy duty) of 600 X 600mm in size of best approved quality and as per standard specifications etc.,complete. |
| 41 | Conducting Geophysical survey, quality and quantity test and transportation charges etc, (This includes labour charges in the field, rent of the vehicle for reaching the place, rent of the instrument and excluding charges for the geologist) |
| 42 | Drilling of borewell anywhere in Tamilnadu includingtransportation from one place to another place withinTamilnadu in alluvial soil or sedimentary strata of clayand sand or sand, stone, shale, pebbles, boulders etc.,by first taking a pilot bore of 140 mm/150mm dia andthen enlarging to required dia by direct or reverse ro tatry mud and circulation method using Contractor’s rig,fuel, labour, drilling, betonite mud and water requiredfor drilling at the site shown by the TWAD Officers in cluding construction of mud pit (only Calyx drills are tobe used). |
| 43 | Supply and Delivery of 150 mm diaPVC casing pipe as IS 12818/1992 Including cost and conveyance to the site etc. complete |
| 44 | Reaming from 6” Pilot bore to 12” size bore as directed by the TWAD Board Officers |
| 45 | labour Charges for inserting 150mm dia OD P.V.C Casing Pipes Assembley (With Slot or With Out Sloter In the Drilled holes Including the jointing the Pipe With P,V,C Coupler with Cement pipes complete |
| 46 | Supply and fixing of three phase(50 X 100) Submersible pumps confirm to IS 8034 and as amended from time to time with ISI marking as per specification for the duty conditions. The rate inclusive of Packing, freight, unloading, Stacking, Transit and insurance charges etc, complete. |
| 47 | Labour charges for the erection of submersible pump set in bore well/open well including fixing and jointing submersible cable with proper clamps up to the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges up to the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventer, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pump set and trail run for 10 days. |
| 48 | Supply and delivery of Three Phase Panel Board - Star Delta with two level Guard and auto start suitable for Submersible pumpsets and accessories including all fittings suitable for Submersible pump sets.Panel Board should be provided as per specification. Rates inclusive of Packing, Loading, Freight, Unloading, Stacking, Transit andInsurance charges etc, complete. |
| 49 | Supply and fixing of 50mm dia UPVC pipes for submersible pump in Bore well. The rate shall inclusive of all labour charges and freight charges etc, complete. |
| 50 | Supplying and fixing of PVC insulated and sheathed 3 core 4sq.mm Flat type Copper cable cofirming to IS 694/ 1990 and including cost and conveyance of all materials to site and labour charges etc, complete as per standard specification. |
| 51 | Supply and fixing of 1000 lit HDPE Tank ISI make with all accessories such as Tank Nipple, Washer etc,including cost and conveyance of all materials to site etc, complete as per standard specifications. |
| 52 | Supply and providing cable end termination of 3-1/2 x 35 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete |
| 53 | Wiring with 2 x 1.5 sq.mm. PVC insulated unsheathed FRLS SC copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires with TW switch box and 5A FT switch in flush with wall with 3mm thick hylum sheet cover for making good of the concealed portion with suitable colour for PVC concealed light point / fan point (for electronic regulator) SD 24 |
| 54 | Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 150 x 100 x 113 mm TW switch box with 3mm hylum sheet cover for5A 3 pin non inter locking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC plug point.etc, complete as per standard specificationsSD 38 |
| 55 | Supply and run of 2 of 1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour.etc, complete as per standard specifications SD 54 |
| 56 | Supply and fixing of single box type 4\"36 W flu fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed Copper leads from terminals to the fitting etc, complete as per standard specificationsSD 87 |
| 57 | Earthing as per P.W.D. standard with an earth electrode of 2Mtr. Class \"B\" GI pipe of dia not less than 32mm complete with necessary masonry work. etc, complete as per standard specificationsSD 212 |
| 58 | Supply and fixing of 3 phase 4 wire 4 way ICDB of 32 A per way with 100 A TPN MC switch with suitable trunking box Ms cable entry boxes and internal connection on suitable angle iron frame work with earth connection etc, complete as per standard specificationsSD.644 |
| 59 | Supply and fixing of Horizontal type 4 way triple pole neutral MCB distribution board in sheet steel enclosure with 40 A 4 pole MCB isolater as incoming and 12 Nos. 6A to 32 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB\"s should be with the ISI mark etc, complete as per standard specificationsSD.531 |
| 60 | Supply and run of 2 of No.8 SWG GI wire for guarding with cradle with No.8 SWG GI wire at the equal interval of 1.5m etc, complete as per standard specifications SD.75 |
| 61 | Supply and run of 4 X6 sq.mm (84/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade on 7/20 Gl bearer wire for service connection mains etc, complete as per standard specifications.SD 68 |
| 62 | Supply and fixing of 300mm (12\") sweep AC exhaust fan complete with necessary wall opening and making good of the wall.etc, complete as per standard specifications. SD 115 |
| 63 | Wiring with 2 x 4sqmm (56 /0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 150 x 100 x 113 mm TW switch box with 3mm hylum sheet cover for15A 3 pin non inter locking CS plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC power plug point. etc, complete as per standard specifications. SD 39 |
| 64 | Supplying and laying of PVC insulated, PVC sheathed, armoured, LTUG cable of size 2 core 10 sqmm Al.cable clamped on walls(SD 210) |
| 65 | Supplying and fixng of cable gland and termination with earth connection of size 2 core 10 sqmm etc, complete as per standard specification. (SD 194) |
| 66 | Supply and fixing of TNEB Board suitable for 3 Phases 63A service connection made up of suitable angle iron frame work of size 2 feet x 1 1/2 feet using angle iron of size 1 1/2\" x 1 1/2\" x 1/4\" rigidly fixed on wall covered with hylem sheet of size 2 feet x 1/2 feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos 63A fuse units(500V) 1 No. Neutral link, copper earth flat of size 1\" x 1/4\" with inter connection of EB meter to fuse units by 7/16 PVC insulated copper wire with earth connection complete.SD 132 |
| 67 | Supply and fixing of 32 A TPN MC switch on incoming and 3 Nos 32 A DPMC Switch (Front Handle) as outgoing with suitable adoptor box with suitable MS cable entry box trunking boxes and internal connections on internal connections on suitable AI frame work with earth connection etc,complete.SD 172 |
| 68 | Supply and fixing of 3 phase 4 wire 4 way ICDB of 16 A per way with 32 A TPN MC switch with suitable MS cable entry boxes trunking box and internal connections on suitable angle iron frame work with PWD earthing etc,complete.SD 173 |
| 69 | Earthing as per the ISI specification with an earth electrode of 2.1mt class \"B\" GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry . SD 211 |
| 70 | Supply and run of 2 of 4sqmm (56/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14SWG Cuwireand making good of the concealed portion with suitable colour(SD57) |
| 71 | Supplying and Laying of 3½ x 50 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 M putting 0.15 M layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. [ SD 215] |
| 72 | Supplying of 4 x 10 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 M putting 0.15 M layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. [SD 180 ] |
| 73 | Supplying and fixing of 1200mm ( 48\"\" ) sweep AC ceiling fan complete with regulator with 1M down rod including S & F of fan clamp with side plates and cross arm etc, complete as per standard specifications SD 466 |
| 74 | Brick Lining for 300mm thick in furance roof Fibre Li 2800L X 900W X 700H in mmning chamber size, Door operation : Up & Down movement manual operated max operating temparature : 700- 900 Dec Celsius. Etc, complete. |
| 75 | LPG Burner set with LPG Bank $ Control Panel: Supply of 4 Nos, 5 Burner with Blower and Fully auto control system like 0,000 Kcal Capacity LPG Fired Ignition, Flame sensor and Auto cut off incorperated in a separate sequencecontoller equivalent to Imported Contol system for air and LPG with auto Igniting system and supply of 20 + 20 cylinder bank with pipeline from LPg cylinder bank up to each Burner end by using TATA \"c\" class grate material pipe with required material etc, complete |
| 76 | 3 hp motor 2no.for use to Id fan & 1hp motor use for wet scrubber Wet Scrubber for gas cleaning system: The system should be enhanced with Stainless steel cylinder and SS ID fan (3hp motor x 2nos. With ISI standard ) to avoid rusting, Volume of water should be increased for effective scrubbing. |
| 77 | Guy Supported Chimney:This is a Cylindrical type MS IS - 2062 quality, 8MM Plate Chimney With two coasted of aluminium Heat Resistance Paint Exrernally, 7000 mm, Long Bottom Cylindrical Chimney. It is Rested on 16mm type MS IS - 2062 Qyality (100 feet Thick Base Flange and Stool Flange 16mm Thick with 12mm Gusset Support, Cylindrical Chimney Mounted on foundation 12nos x 25mm Dia Bolt, Nut Joints, Top 1 Cylindrical Shell Boiler Quality 8mm Plate x 7000mm long base chimney. It is Rested 50mm width base Flange & wind forece curtain MS Flat Set, with Lightening arrestor 25mm x 3mm copper flat earthing, with easy hinges type manual opened manhole door, necessary for pollution control boardmonitoringm sample ports arrangment ladder assembly with safety guard set 70 feet full height, one sets of detachable platform, over all size: 800mm Dia x 400mm Dia x 21000mm length with necessary all arrangements etc., complete |
| 78 | Erection, Testing and Commissioning charges for Gasifier etc, complete |
| 79 | Providing and laying, spreading and compacting graded stone aggregates to Wet Mix Macadam 250mm thick specification including premixing the materials with water at OMC in mechnanical mix plant carriage of mixed material by tipper to site laying in uniform layers with pavers in Sub Base/ Base course on well prepared surface and compacting with vibratory roller to acheive the desired density including cost of material, labour charges, rentals for machinery, fuel and all other incidental charges etc.,complete as per clause 406 of MORTH |
| 80 | Supply and laying precast designer Paver Block confirming to IS 15658-2006 specification manufacturing and laying standard of M40 grade 83mm thick (Table Clauses sand 9.14) suitable for bus terminals, Industrial Complexes Road on expensive soils tec.,) including the cost of paver block of size 225mm x 112.50mm x 83mm and conveyance of materials to work site mentioned in the tender schedule cost of loading and unloading handling during over sand bed of 150mm thick (Excluding the cost of sand) conveyance paver block cutter to site and hire charges of vibrators and paver block cutter and labour charges for vibrator and paver block cutter operators and labour for levelling the sand to the paver block etc., complete IS 15658-2006 |
| 81 | Supply, Delivary, Eraction, Testing and commissiong of 20KVA Generater with auto main failure (AMF) Pannel Three phase output Voltage 450V constiting of Diesel engine capable of delevery of continues breack loss Power with standard fitting water colled radiators assuring closer etc. complite as per standard specification . |
| 82 | Plain Cement Concrete 1:2:4 (one cement, two Crushed Stone Sand (M- Sand) and four coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour chargesetc., complete as per standard specification ( Foot Path) |
| 83 | Earth work excavation for foundation in all soils such as red earth ,hard stiff clay soil, stiff black cotton soil, hard redearth,shales, murrams, gravel,hard rock not requiring blasting ete complete. ( Compound Wall ) |
| 84 | Cement concrete 1:4:8 mix usin 40 mm HBGS metal inculding cost and coveyance of all materials to site including labour for mixing ,l aying,curing etc complete.,( Compound Wall ) |
| 85 | Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - ( Compound Wall ) |
| 86 | Supplying and fabrication,placing in position of mild steel or ribbed Tor steel grils for RCC works inculding cost of steel and binding wire etc.( Compound Wall ) |
| 87 | Supplying and erection centering for sides and soffits inculding necessary supports and structing for plain surfaces such as RCC Slab,Lintel,Beam coloum,sunshade etc complete.,( Compound Wall ) |
| 88 | Grade beam |
| 89 | Column |
| 90 | Brick work in CM 1:5 (one cement & Five sand) using II class ground moulded bricks of size 9\"X43/8\"X 23/4\" standard specification including finishing, curing, etc., complete complying with standard specification (Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost)- Upto Basement ( Compound Wall ) |
| 91 | Plastering with cement mortar 1:5 (One part of Cement and Five part of Plastering Sand (P- Sand)) 12mm, thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications ( Compound Wall ) |
| 92 | Painting two coats of newly plastered wall surface with ready mixed Cement paint of first quality and of approved colour over a priming coat including preparing the surface, clean removal of dirt and including necessary plaster of paris putty wherever required etc., complete complying with standard specification.( Compound Wall ) |
| 93 | Internal Water Supply - P.V.C. Pipes (6Kg/SqCm) Supplying laying and jointing P.V.C pipes (6Kg/SqCm) of approved quality and best variety conforming to I.S.S & with I.S.I mark, of the following sizes including cutting , Fixing to PVC specials using Adhesive but excluding cost of such specials and fixing to wall with necessary teak - Wood Plugs,PVC Clamps and screws,making holes on the wall or drilling holes in roof and making good the dismantled portions to original condition with necessary brick work and plastering wherever necessary with necessaryscaffolding charges. |
| 94 | 32mm |
| 95 | 25mm |
| 96 | Supplying and fixing in position best quality P.V.C soil/ waste pipes (6KSC) of various sizes having ISI mark and providing leakproof joints including fixing to the wall with P.V.C/ M.S clamps etc., and making connection to all sanitaryfittings, dismandling masonry/R.C.C. works wherever necessary and making good the dismandled portion to the original condition, complying with standard specifications. |
| 97 | 110mm |
| 98 | 90mm |
| 99 | Providing & fixing PVC RAIN WATER DOWNFALL PIPE of the following dia with necessary T.W.Clamps Plugs, Shoes,Bemds, other clamps, screws nails etc.,complete complying with standard specification. The rate is inclusive of cost of removable iron gratings of appropriate size. The size of Teak Wood plugs used is 150X25mm in front & 200x75mm in rear (wall side) with a depth of 110mm. The pipe is to be fixed by means of \"U\" clamps at the centre of pipes to be fixed.110mm dia PVC Pipe [4 Kg/SqCm] |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail