Development Of Kasturba Nagar Walkway Under Urbs Panampally Nagar Kochi-- 1 SITE CLEARANCE ,COMPOUND WALL & FENCING WORKS 2 2.31 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared 3 2.28.1 Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.All kinds of soil 4 15.6 Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved 5 2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 6 od148366/2024_2025 DR rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand DR 7 5.1.3 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 8 5.9.16.1 Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide 9 5.22.1 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Mild steel and Medium Tensile steel bars 10 50.6.1.1 Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete 11 13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 12 16.78.2 Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 13 50.2.26.1 Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge. 14 16.70.2 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts , bolts and washers as required complete as per the direction of Engineer-in- charge.Made of G.I wire of dia 4 mm. PVC coated to achieve outer dia. not less than 5 mm in required colour and shade. 15 10.1 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 16 13.52.1 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work 17 13.48.1 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm 18 7.1.1 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 19 od143791/2024_2025 Petty works at site, coolie 20 30.2.2 Supplying and stacking of good earth at site including royalty and carriage upto 5 k.m. lead complete (earth measured in stacks will be reduced by 20% for payment). 21 SEATING WORKS 22 2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 23 4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 24 50.6.1.1 Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete 25 13.1.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 26 8.2.2.2 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm 27 8.3.2 Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work 28 13.48.1 Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm 29 od225918/2024_2025 Brick cladding work for wall lining upto 10 m height with special adhesive over 12mm thick bed of cement mortar 1:3 (1 cement :3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shade.25mm thick brick tile 30 50.6.1.4 Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete 31 od237082/2024_2025 Supplying, Providing & placing of park seating benches with cast iron frame with wooden seating and of size 60 L, 16W, 20 H at site with primer and required finishes of paint including loading, unloading, carriage etc.and as per direction of officer in charge. 32 LANDSCAPING WORKS 33 2.8.1 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil 34 2.1.1 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil 35 60.7.1 DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site 36 7.1.1 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 37 4.1.8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 38 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 39 6.2.2 Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand) 40 13.66.1 Floor painting with floor enamel paint of approved brand and manufacture of required colour to give an even shade:Two or more coats on new work 41 5.9.16.1 Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide 42 5.1.3 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 43 5.22.1 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars 44 4.6.1 Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), including the cost of required centering, shuttering complete.1:1.5:3 ( 1 cement : 1.5 coarse sand (Zone III): 3 graded stone aggregate 20 mm nominal size) 45 13.52.2 Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work 46 8.2.2.2 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm 47 8.3.2 Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work 48 13.4.1 12 mm cement plaster of mix:1:4 ( 1 cement : 4 coarse sand) 49 13.45.1 Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm 50 od143791/2024_2025 Petty works at site, coolie 51 od151619/2024_2025 providing ,supplying and installing waste bins with steel sheet covered with recycled plastic materiails as per required shape and colour 52 od151698/2024_2025 making , installing name board letters in acrylic material with steel pipe framing as per required design and dimensions. 53 od227248/2024_2025 Cleaning the surface and removing dirt,dust,greese,oil,algae,fungus including washing the surface with the help of required srubbers and cleaning with machine operated water jet etc. Without causing any damage to the existing structure 54 od227600/2024_2025 Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete.Granite of required shade and colour for inuaguration stones at carious parks 55 16.68 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. 56 16.83 Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. 57 16.84 Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost.) 58 22.12 Supplying and applying bituminous solution primer on roof and or wall surface at 0.24 litre per sqm. 59 od233545/2024_2025 Providing and placing of Cycle Track as per specific grade M-25 decor concrete of average thickness of 100 mm, fiber used as re-inforcement 600gm/M3 level and finish the concrete by using straight edge vibrator with the screed action, Finish the concrete surfce by using Magnesium bull float, Expansion joint should be provided at 4.50 M interval, At top layer colour hardener should be provided and level with magnesium float, including markings, curing, etc. complete as per the direction of Engineer-in-charge. 60 GARDENING WORKS 61 od143766/2024_2025 Planting HIBISCUS RED by Digging pit in all kinds of soil and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and planting trees supplied with roots covered with appropriate natural containers from the source of availability including all conveyance, transported without any damage to the root pods, covering the stem with necessary hay etc., caring and protecting the plants transported and unloaded at site till planting in pits of size 120 cm diameter, and 120 cm deep, HIBISCUS RED . Appropriate Length of softwood props shall be provided as supports for the plants as directed. The trees have to be maintained for a period of 3 months after the entire planting of trees is completed. The Rate shall include necessary labour, supply of materials, safe keep of plants, cost of conveyance, removal of rubbish and surplus earth etc. Complete.HIBISCUS RED 62 od143767/2024_2025 Planting trees by Digging pit in all kinds of soil and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and planting trees supplied with roots covered with appropriate natural containers from the source of availability including all conveyance, transported without any damage to the root pods, covering the stem with necessary hay etc., caring and protecting the plants transported and unloaded at site till planting in pits of size 120 cm diameter, and 120 cm deep, MIMUSOPS ELENGI 1 MTR. Appropriate Length of softwood props shall be provided as supports for the plants as directed. The trees have to be maintained for a period of 3 months after the entire planting of trees is completed. The Rate shall include necessary labour, supply of materials, safe keep of plants, cost of conveyance, removal of rubbish and surplus earth etc. Complete.MIMUSOPS ELENGI 1 MTR 63 od143768/2024_2025 Planting STAR JASMINE by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings free of all pests and deceases from the source of availability including all conveyance, transported without any damage to the cuttings, covering, caring and protecting the plants transported and unloaded at site. The plants have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of plants, cost of conveyance, removal of rubbish and surplus earth etc. Complete.45cm height 64 od143770/2024_2025 Planting JUNGLE JERANIUM by Digging pit in all kinds of soil and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and planting trees supplied with roots covered with appropriate natural containers from the source of availability including all conveyance, transported without any damage to the root pods, covering the stem with necessary hay etc., caring and protecting the plants transported and unloaded at site till planting in pits of size 120 cm diameter, and 120 cm deep, JUNGLE JERANIUM . Appropriate Length of softwood props shall be provided as supports for the plants as directed. The trees have to be maintained for a period of 3 months after the entire planting of trees is completed. The Rate shall include necessary labour, supply of materials, safe keep of plants, cost of conveyance, removal of rubbish and surplus earth etc. Complete.JUNGLE JERANIUM 65 od143775/2024_2025 Planting JASMINE VINES PLANTS by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance, transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of Groundcovers, cost of conveyance, removal of rubbish and surplus earth etc. Complete.90cm height 66 od143776/2024_2025 Planting LEMON GRASS SHRUBS by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance, transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of Groundcovers, cost of conveyance, removal of rubbish and surplus earth etc. Complete.30cm height 67 od143777/2024_2025 Planting GOLDEN SHOWER PLANT by Digging pit in all kinds of soil and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and planting trees supplied with roots covered with appropriate natural containers from the source of availability including all conveyance, transported without any damage to the root pods, covering the stem with necessary hay etc., caring and protecting the plants transported and unloaded at site till planting in pits of size 120 cm diameter, and 120 cm deep, GOLDEN SHOWER TREE 90CM HEIGHT . Appropriate Length of softwood props shall be provided as supports for the plants as directed. The trees have to be maintained for a period of 3 months after the entire planting of trees is completed. The Rate shall include necessary labour, supply of materials, safe keep of plants, cost of conveyance, removal of rubbish and surplus earth etc. Complete. 68 od143778/2024_2025 Planting BERMUDA GRASS by excavating planting bed 30 cm deep at specified area shown in the planting plans and preparing the same with thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying and planting Grass Buffalo grass sod, machine cut at a uniform soil thickness of 15 mm, plus or minus 6 mm, at the time of cutting, measurement for thickness shall exclude top growth and thatch. Individual pieces of Buffalo grass sod shall be cut to the supplier’s standard width and length. Maximum allowable deviation from standard widths and lengths shall be plus or minus 15 mm on width and plus or minus five percent on length. Broken pads and torn or uneven ends will not be acceptable. Standard size sections of Buffalo grass sod shall be strong enough that it can be picked up and handled without damage. Buffalo grass sod shall not be harvested or transplanted when its moisture content (excessively dry or wet) may adversely affect its survival. Before harvesting, the turfgrass shall be mowed uniformly at a height of 25 to 60 mm on winter season grasses and 20 to 40 mm on summer season. Grass turfgrass sod should be transported unloaded at site with care and protection and without any damage. The planted Grass turf grass have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of Grass , cost of conveyance, removal of rubbish and surplus earth etc. Complete.BERMUDA GRASSDetails of cost for 10 sqm. 69 od150306/2024_2025 Planting MUNTINGIA by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings free of all pests and deceases from the source of availability including all conveyance, transported without any damage to the cuttings, covering, caring and protecting the plants transported and unloaded at site. The plants have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of plants, cost of conveyance, removal of rubbish and surplus earth etc. Complete.45cm height 70 od150918/2024_2025 Planting BOUENGENVILLA PLANTS by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance, transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of Groundcovers, cost of conveyance, removal of rubbish and surplus earth etc. Complete. 71 od226976/2024_2025 d128543/2024_2025 :Planting JUNGLE JERANIUM by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance, transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of Groundcovers, cost of conveyance, removal of rubbish and surplus earth etc. Complete. 1 FEET6 INCH JUNGLE JERANIUM 45cm height 72 od226977/2024_2025 d128543/2024_2025 :Planting ARABIAN JASMINE by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance, transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials,safe keep of Groundcovers, cost of conveyance, removal of rubbish and surplus earth etc. Complete. 1 FEET6 INCHARABIAN JASMINE 45cm height 73 od226978/2024_2025 d128543/2024_2025 :Planting GIANT ELEPHANT EAR PLANT by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance, transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of Groundcovers, cost of conveyance, removal of rubbish and surplus earth etc. Complete. 1 FEET6 INCHGIANT ELEPHANT EAR PLANT 90cm height 74 od226979/2024_2025 d128543/2024_2025 :Planting CANA LILLY by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance, transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3 months after the entire planting is completed. The Rate shall include necessary labour, supply of materials, safe keep of Groundcovers, cost of conveyance, removal of rubbish and surplus earth etc. Complete. 1 FEET6 INCHCANA LILLY 45cm height 75 od226980/2024_2025 od128543/2024_2025 :Planting UMBRELLA PLANT by excavating planting bed 45 cm deep at specified area shown in the planting plans and refilling the same with a thorough mix of good quality fertile soil, river sand, dried cow dung manure and leaf mould mixed in the ratio of 1:1:1:1, removal of rubbish and surplus earth if any, including lead, lift etc. as directed by the engineer in charge and supplying good healthy cuttings of groundcovers free of all pests and deceases from the source of availability including all conveyance, transported without any damage to the cuttings, covering, caring and protecting the groundcovers transported and unloaded at site. The Groundcovers have to be maintained for a period of 3safe keep of Groundcovers, cost of conveyance, removal of rubbish and surplus earth etc. Complete. 1 FEET6 INCHUMBRELLA PLANT 45cm height 76 PLUMBING WORKS 77 18.51.1 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore 78 18.9.2 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work20 mm nominal outer dia pipes 79 50.18.8.2.2 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2 80 18.49.1 Providing and fixing C.P brass bib cock of approved quality conforming to IS: 8931.15 mm nominal bore 81 18.53.1 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore 82 50.18.9.14.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall 83 18.37.1 Constructing masonry chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 ( 1 cement : 4 coarse sand) for water meter complete with C.I double flap surface box 400x200x200 mm ( inside ) with locking arrangement and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 grades stone aggregate 20 nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5 84 50.18.8.7.1 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work including cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2 85 50.18.9.9.1 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 86 50.18.9.20.4 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Bend 87 od143765/2024_2025 Supply, installation, testing & commissioning of Centrifugal Pressure pump of 20 LPM @ 19/27M 1 HP size 25x25 240 V, with pumps with control panel, with all necessary valves, flexible connections, supports, fixings and fittings electrical/ control panels, power and control cabling , cable trays etc. as specified and as shown on drawings and complying to relevant standards. 88 18.17.1A Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal bore 89 od143774/2024_2025 Providing and placing a polyethylene water storage tank :ISI 12701 marked,in UG tank with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Ref . OD 18.48 90 od144640/2024_2025 Providing and placing Ferro cement UG soak pit with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank as per the direction of engineer in charge. 40 flush capacity od 51.19.ST1 91 2.6.1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil 92 od150721/2024_2025 Providing and placing Ferro cement tank, in UG water tank (2000 LTR) with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank as per the direction of engineer in charge od 18.48 93 17.7.1 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps 94 17.9.1 Providing and fixing kitchen sink with C. I brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required:White glazed fire clay kitchen sink of size 600x450x250 mm 95 od168435/2024_2025 Supply and fixing of CI manhole frame and cover of lockable type ( Double Sealed ) over openings of under ground sump, overhead tank,rain water Sump, soak pits.600X600 Manhole cover with medium duty 96 od168436/2024_2025 Providing and fixing overall semi circular PVC GUTTER of 150 mm dia of with necessary clambs , bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. 97 18.18.2 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:20 mm nominal bore 98 SNACK BAR 99 2.6.1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil 100 60.7.1 DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course masonry with good quality blasted rubble including packing to compactness to lines and levels cost and conveyance of all materials labour charges etc. complete as per direction of Departmental officers at site 101 7.1.1 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand) 102 5.9.16.1 Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wide 103 5.9.5 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 104 5.1.2 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size 105 5.22A.1 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Mild steel and Medium Tensile steel bars 106 10.1 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 107 9.18.2 Providing and fixing Pre- laminated flat pressed 3 layer ( medium density) particle board or graded wood particle board IS : 3087 marked, with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer ( fittings to be paid separately)25 mm thick 108 21.1.1.2 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 109 9.79.1 Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete.40 mm 110 9.80 Providing and fixing 50 mm bright finished brass cup board or wardrobe knob of approved quality with necessary screws. 111 9.114.2 Providing and fixing magnetic catcher of approved quality in cupboard/ward robe shutters, including fixing with necessary screws etc. complete.Double strip (horizontal type) 112 9.165.1 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.125 mm 113 9.70.1 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete:Water thinnable cement primer 114 od144572/2024_2025 Providing & fixing Aluminum Galvanised Insulated Sandwich PUF Panels as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling/ self tapping screw of size (5.5x55mm) with EPDM seal complete upto any pitch in horizontal / vertical / curved surfaces, but excluding the cost of purlins, rafters, trusses and including cutting to size and shapes where ever required. OD FROM 50.12.2.2 115 13.43.1 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 116 13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 117 13.83.1 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.One coat 118 13.46.1 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 119 11.46.2 Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm 120 10.6.3 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x0.90 mm M.S. laths with 0.90 mm thick to cover 121 od227165/2024_2025 Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge.Note - item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more. 122 21.18 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately) 123 Morth items 124 55.22 Supplying and laying interlocking tile 100 mm or nearest size thickness, minimum strength M 40 including providing a layer of 6 mm aggregate for 5 cm thickness, then laying interlock cobbles in lines and levels as per the directions of the departmental officers at site inclusive of all cost & conveyance charges etc.; complete. 125 Electrical Work-Kiosk 126 od232026/2024_2025 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI/ plastic box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B 127 1.14.1 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire. 128 1.14.2 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire. 129 90.6.5.13 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 4.00 sq mm 130 1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch 131 1.24.3 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch 132 1.24.4 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet 133 1.24.5 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet 134 90.10.1.2 Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface 135 90.10.1.3 Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface 136 90.10.1.6 Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )8 module moulded plastic box on surface 137 1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 138 2.3.2 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door 139 2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 140 2.10.2 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural 141 2.11 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 142 2.14.1 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps 143 1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 144 90.16.1.11 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.06 mm GI conductor (8 SWG) 145 od231691/2024_2025 Supply, Installation, Testing and Commissioning of Nickel coated Copper bonded electrode made from low carbon steel. Earth rods and molecularly bonded with 99.9 % pure electrolytic copper with 250 micron coating, 17.2 mm dia with pressed contact including stainless steel nut, bolts and washers.Copper bonded rod of size (17.2mm x 2000mm) with chemical bag with all accessories.The earth rod should be properly covered with UV resistant earth pit Chamber complied to IEC62561-5 including boring of earth pit suitable for the earthing to be done as per the dimension of earth rod. 146 od231693/2024_2025 Supply, installation, testing and commissioning of outdoor type weather proof single phase energy meter box made of CRCA sheet with power coated including fuse upto 25 A rating but excluding energy meter of reputed make 147 od231776/2024_2025 Supply, Installation, Testing & Commissioning of 300 mm sweep Wall mounting oscillating type fan including all accessories of approved make as required for use on 240V AC supply. 148 od231695/2024_2025 Supply, Installation, Testing & Commissioning of 200mm sweep Exhaust Fan with self opening lowers suitable for operation on single phase 230V ,50Hz AC supply complete with all accessories as required complete. 149 od231734/2024_2025 Supply, Installation, Testing & Commissiong of Surface Mounted 12 W Round Led Panel Light of reputed make. 150 Electrical Work-Open Space 151 14.15.1 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm· dia (OD-63 mm & ID-51 mm nominal) 152 90.12.9.2 Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench 50/38 mm or nearest size 153 90.16.1.4 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 4.00 mm copper conductor ( 8 SWG) 154 90.6.5.11 Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm 155 90.12.5.39 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 6 sq mm 156 od231691/2024_2025 Supply, Installation, Testing and Commissioning of Nickel coated Copper bonded electrode made from low carbon steel. Earth rods and molecularly bonded with 99.9 % pure electrolytic copper with 250 micron coating, 17.2 mm dia with pressed contact including stainless steel nut, bolts and washers.Copper bonded rod of size (17.2mm x 2000mm) with chemical bag with all accessories.The earth rod should be properly covered with UV resistant earth pit Chamber complied to IEC62561-5 including boring of earth pit suitable for the earthing to be done as per the dimension of earth rod. 157 od231692/2024_2025 Supplying and making end termination with aluminium lugs for following size of PVC insulated and PVC sheathed XLPE aluminium conductor cable of 1.1 KV grade as required for input and output of the cable 4 X 6 Sq.mm in flush terminal box of pole. 158 90.12.5.12 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3 core 4 sq mm 159 od232441/2024_2025 Supplying and making end termination with aluminium lugs for following size of PVC insulated and PVC sheathed XLPE aluminium conductor cable of 1.1KV grade as required for input and output of the cable 3 X 4 Sq.mm in flush terminal box of pole 160 od232668/2024_2025 Supply and Installation of outdoor weather proof IP66 rated Junction Box including associated accessories of approved make 161 od232669/2024_2025 Supply and Installation of 7/7.5 Meter Height Decorative Twin Arm Differential Pole with minimum 500 mm arm length to mount luminaire and with bracket for provision of advertisement board which is fabricated using conical pole made of high tensile mild steel/steel tube with minimum thickness of 3 mm. The pole shall have single section having base dia of minimum 135 mm and top dia of minimum 70 mm. Structurally designed steel base plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed RCC foundation. The pole shall be able to withstand wind speed pressure as per IS 875(part-3) & structural calculation report as per EN40 should be submitted to verify the pole design. The base section of Pole shall have an in-built junction box to fix connectors and MCB at the bottom. The complete structure shall be hot dip galvanized through seven stage process and minimum average coating shall not be less than 65 microns before treating with primer. After galvanisation structure shall be treated with high quality primer and thereafter coated with Polyurethane paint customized colour as approved by engineer in charge (final coating thickness of average DFT of 100 microns minimum). The complete structure should be hot dip galvanised and marine grade treated for the effective corrosion resistance. 162 od232386/2024_2025 Supply, Installation, Testing & Commissioning of Designer LED bollard light with Decorative Laser Design area or approved design as directed by engineer in charge engraved in the CRCA model. System wattage of 10-20 Watts having maximum output of 2000 lumen, Luminious Efficacy of => 40 lm /W, upto 4 Feet Height, Standard Electronic Driver having Inbuilt Surge Protection of 4KV minimum, LED Chips of approved make, LED Life expectancy shall be greater than 50000 hrs, efficiency of 85% or above, CCT of 3000K – 4500K, CRI of 80 or above, Powder Coated finish, Ingress Protection of IP65 or above. 163 od232630/2024_2025 Supply, Installation, Testing and commissioning of decorative LED street lantern with a suitable wattage with system lumens > 3500 Lumens having LED Chips of CREE/ NICHIA/ OSRAM/ SEOUL/ LUMILEDS make. Overall system efficiency of 115 lm/W at correlated colour temperature (CCT) of 4000- 5000K. The housing material should be spun Aluminium and PMMA/PC protector, CRI 70, LED Life expectancy @L70 > 50000 hrs, IP66 ingress protection, Impact ressitance - IK07, Power Factor>0.95, THD< 10%. System which offers Protection against Short Circuit, Over- Voltage & Over- Current with in-built surge protection up to 4kv and an additional surge protection device of 10kV. LM report should be submitted from NABL accredited lab 164 od232631/2024_2025 Supply, Installation, Testing and commissioning of decorative LED street lantern with a suitable wattage with system lumens > 6900 Lumens having LED Chips of CREE/ NICHIA/ OSRAM/ SEOUL/ LUMILEDS make. Overall system efficiency of 115 lm/W at correlated colour temperature (CCT) of 4000- 5000K. The housing material should be spun Aluminium and PMMA/PC protector, CRI 70, LED Life expectancy @L70 > 50000 hrs, IP66 ingress protection, Impact ressitance - IK07, Power Factor>0.95, THD< 10%. System which offers Protection against Short Circuit, Over- Voltage & Over- Current with in-built surge protection up to 4kv and an additional surge protection device of 10kV. LM report should be submitted from NABL accredited lab.