| 1 | Job Work of AVR Servicing |
| 2 | Jyoti Make 1.5 MW panel’s relay tripping system (Testing & calibration with relay) |
| 3 | KEC make 1.5 MW panel’s relay tripping system(Testing & calibration with relay) |
| 4 | BHEL Make 3.00 MW panel’s relay tripping system (Testing & calibration with relay) |
| 5 | Servicing/Checking/Testing after (Dismantling and Assambling) of Jyoti Make Alternator |
| 6 | Servicing/Checking/Testing after (Dismantling and Assambling) of KEC Make Alternator |
| 7 | BHEL Make 3.00 MW AVR (Two mode) Repairing & Testing work |
| 8 | Power Tech make 1.5 MW AVR(Four mode) Repairing & Testing. |
| 9 | Testing & Replacement of CT of Pannel Board |
| 10 | Wiring make of BHEL Panel to AVR and Relay |
| 11 | KEC / Jyoti make Panel Spares repairing work of 7.5 MW Panel & AVR with suitable of required material |
| 12 | KW Meter 3Ø, 4 wire, Range (0-2500), CTR, 2500/5 |
| 13 | Under Voltage Relay, 24 VDC |
| 14 | Transformer I/O AC 230 V./150 V. |
| 15 | Our Current Relay, 24 V DC, CTR 2600/5 |
| 16 | MultifunctionMeter, 3Ø, 4 wire, 5500/1 |
| 17 | Master Trip Relay, 24 V. DC |
| 18 | KEC / Jyoti make AVR 1.5 MW Spares |
| 19 | Control Card PTE-2014 A1 |
| 20 | PC Filter |
| 21 | Amp. Meter 0 to 3000, CT Ratio 2600/5 Amp. Size - 144 x 144 mm |
| 22 | Amp. Meter 0 to 3000, CT Ratio 3000/5 Amp. Size - 144 x 144 mm |
| 23 | Thyristor Module |
| 24 | Diode Module |
| 25 | Control Transformer TR-1 |
| 26 | Sensing Transformer TR – 2/3 |
| 27 | Synchronizing TR – 4 |
| 28 | Filter Choke TR – 5 |
| 29 | Pot. I k Ω , 2 W , Multi turn |
| 30 | Pot. 500 Ω , 2 W , Multi turn |
| 31 | BHEL Make AVR 3 MW Sparesrepairing work of 3 MW Panel & AVR with wire and other material |
| 32 | Control Card PTE – 2014 – A1/PC-191 |
| 33 | Rotor Diode BHDN3016 |
| 34 | Rotor Diode BHDN3116 |
| 35 | Heat Sink |
| 36 | Amp. Meter 0 to 6000, CT Ratio 5200/1A Amp. Size - 144 x 144 mm |
| 37 | CT 5200/5A. Class 5P 10 |
| 38 | Thyristor Module |
| 39 | Diode Module |
| 40 | Control Transformer TR-1 |
| 41 | Sensing Transformer TR – 2/3 |
| 42 | Synchronizing TR – 4 |
| 43 | Filter Choke TR – 5 |
| 44 | Selector Switch 2 Way, 12 Pole |
| 45 | Spare for Jyoti AVR & Protection Panel |
| 46 | Control Card PTE PCB Card 2019 |
| 47 | Multi junction Meter DigitalSize- 96 x 96 |
| 48 | LED Panel Indicator Red , Yellow, Blue & Green |
| 49 | Power factor Meter Digital Size- 144 x 144 |
| 50 | Spare for KEC AVR & Protection Panel. |
| 51 | Control Card PTE PCB Card 2014 A1 |
| 52 | Multi junction Meter Size- 96 x 96 |
| 53 | Spare for BHEL AVR& Protection Relay |
| 54 | Frequency MeterSize- 96 x 96 |
| 55 | Power factor Meter Size- 96 x 96 |
| 56 | L & T Make Multi Junction relay ( Earth fault, UV, OV, Over Current) |
| 57 | Control card for 3 MW BHEL |
| 58 | Thyristor module for 1.5 MW, 16 A |
| 59 | Diode Module for 1.5 MW, 16 A, 1400 V |
| 60 | Field Amp. Meter 0 to 10 V, Analog, Field Voltage meter |
| 61 | Digital Multijunction Meter. |
| 62 | Auto manual Selector Switch 10 Amp., 440 V, Modal No. SRP 11125 B/LMX |
| 63 | Phase Indication LED Lamp,Red, Green, Yellow, Blue |