}

Tender For Supply Of Gate_Globe And Check Cast Valve For Ag_Ug Piping For Msb, Pfcc, Gds And Ff Units For Nrep, numaligarh-Assam

Numaligarh Refinery Limited has published Tender For Supply Of Gate_Globe And Check Cast Valve For Ag_Ug Piping For Msb, Pfcc, Gds And Ff Units For Nrep. Submission Date for this Tender is 06-06-2025. Gate Valves Tenders in numaligarh Assam. Bidders can get complete Tender details and download the document.




Tender Notice

49184704
Tender For Supply Of Gate_Globe And Check Cast Valve For Ag_Ug Piping For Msb, Pfcc, Gds And Ff Units For Nrep
Tender
Indian
Assam
Numaligarh
06-06-2025

Tender Documents

Tender Details

Supply Of Gate_Globe And Check Cast Valve For Ag_Ug Piping For Msb, Pfcc, Gds And Ff Units For Nrep Supply Of Gate _Globe And Check Cast Valve For Ag_Ug Piping For Msb, Pfcc, Gds And Ff Units For Nrep , Group-1 (Group Wise Evaluation) Supply Of Gate Valve (Cs_Internally Coated & Cs_Galv.Moc) For Ag+Ug Piping For Nerp Project Including Tpi Charges As Specified In Material Requisition. , Gate Valve Cs Int. Coated, 150,0, Api 600, Flgd,B16.5, Ff, Bb, Bolted Gland, Go, With Locking Arrangement, A216 Gr.Wcb, Bronze, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, Internally Liquid Epoxy Coated Acc. To, Doc. Nr-0Zzzz-Cv-Spe-0019 , Gate Valve Cs Int. Coated, 150,0, Api 600, Flgd,B16.5, Ff, Bb, Bolted Gland, Go, With Locking Arrangement, A216 Gr.Wcb, Bronze, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, Internally Liquid Epoxy Coated Acc. To, Doc. Nr-0Zzzz-Cv-Spe-0019 , Gate Valve Cs Int. Coated, 150,0, Api 600, Flgd,B16.5, Ff, Bb, Bolted Gland, Go, With Locking Arrangement, A216 Gr.Wcb, Bronze, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, Internally Liquid Epoxy Coated Acc. To, Doc. Nr-0Zzzz-Cv-Spe-0019 , Gate Valve Cs Int. Coated, 150,0, Api 600, Flgd,B16.5, Ff, Bb, Bolted Gland, Ho, With Locking Arrangement, A216 Gr.Wcb, Bronze, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, Internally Liquid Epoxy Coated Acc. To, Doc. Nr-0Zzzz-Cv-Spe-0019 , Gate Valve Cs Int. Coated, 150,0, Api 600, Flgd,B16.5, Ff, Bb, Bolted Gland, Ho, With Locking Arrangement, A216 Gr.Wcb, Bronze, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, Internally Liquid Epoxy Coated Acc. To, Doc. Nr-0Zzzz-Cv-Spe-0019 , Gate Valve Cs Int. Coated, 150,0, Api 600, Flgd,B16.5, Ff, Bb, Bolted Gland, Go, With Locking Arrangement, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, Internally Liquid Epoxy Coated Acc. To, Doc. Nr-0Zzzz-Cv-Spe-0019 , Gate Valve Cs Int. Coated, 150,0, Api 600, Flgd,B16.5, Ff, Bb, Bolted Gland, Ho, With Locking Arrangement, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, Internally Liquid Epoxy Coated Acc. To, Doc. Nr-0Zzzz-Cv-Spe-0019 , Gate Valve Cs Int. Coated, 150,0, Api 600, Flgd,B16.5, Ff, Bb, Bolted Gland, Ho, With Locking Arrangement, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, Internally Liquid Epoxy Coated Acc. To, Doc. Nr-0Zzzz-Cv-Spe-0019 , Gate Valve Cs Int. Coated, 300,0, Api 600, Flgd,B16.5, Ff, Bb, Bolted Gland, Ho, With Locking Arrangement, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, Internally Liquid Epoxy Coated Acc. To, Doc. Nr-0Zzzz-Cv-Spe-0019 , Gate Valve Cs Int. Coated, 300,0, Api 600, Flgd,B16.5, Ff, Bb, Bolted Gland, Ho, With Locking Arrangement, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, Internally Liquid Epoxy Coated Acc. To, Doc. Nr-0Zzzz-Cv-Spe-0019 , Gate Valve Cs (Galv.), 150,0, Api 600, Flgd,B16.5, Ff, Bb, Bolted Gland, Ho, With Locking Arrangement, A216 Gr.Wcb(Galv.), 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs (Galv.), 150,0, Api 600, Flgd,B16.5, Ff, Bb, Bolted Gland, Ho, With Locking Arrangement, A216 Gr.Wcb(Galv.), 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs (Galv.), 150,0, Api 600, Flgd,B16.5, Ff, Bb, Bolted Gland, Ho, With Locking Arrangement, A216 Gr.Wcb(Galv.), Bronze, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs (Galv.), 150,0, Api 600, Flgd,B16.5, Ff, Bb, Bolted Gland, Ho, With Locking Arrangement, A216 Gr.Wcb(Galv.), Bronze, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs (Galv.), 300,0, Api 600, Flgd,B16.5, Ff, Bb, Bolted Gland, Ho, With Locking Arrangement, A216 Gr.Wcb(Galv.), 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs (Galv.), 300,0, Api 600, Flgd,B16.5, Ff, Bb, Bolted Gland, Ho, With Locking Arrangement, A216 Gr.Wcb(Galv.), 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Group-2(Group Wise Evaluation) Supply Of Gate Valve (As_Moc) For Ag+Ug Piping For Nerp Project Including Tpi Charges As Specified In Material Requisition. , Gate Valve As, 150,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., A217 Gr.C5, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Grb16/A194gr.16, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009 , Gate Valve As, 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., A217 Gr.C5, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Grb16/A194gr.16, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009 , Gate Valve As, 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., A217 Gr.C5, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Grb16/A194gr.16, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009 , Gate Valve As, 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Go, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., A217 Gr.C5, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Grb16/A194gr.16, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009 , Gate Valve As, 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Go, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., A217 Gr.C5, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Grb16/A194gr.16, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009 , Gate Valve As, 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Go, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., A217 Gr.C5, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Grb16/A194gr.16, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009 , Gate Valve As, 600,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., A217 Gr.C5, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Grb16/A194gr.16, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009 , Gate Valve As (H2 Ser.), 600,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., A217 Gr.Wc6, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Grb16/A194gr.16, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009 , Gate Valve As (H2 Ser.), 900,0, B16.34, Flgd,B16.5, Rtj, Ho, Pressure Seal Bonnent As Per, B16.34, A217 Gr.Wc6, 5, Flexible Graphite, Graphite, A193 Gr.B16/A194gr16, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009 , Gate Valve As (Ibr), 900,0, B16.34, Flgd,B16.5, Rtj, Pressure Seal Bonnet As Per, B16.34, Go, A217 Gr.Wc6, 5, Flexible Graphite, Graphite, A193 Gr.B16/A194gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, Ibr Certificate As Per Specification For, Valves , Group-3(Group Wise Evaluation) Supply Of Gate Valve (Ss_Moc) For Ag+Ug Piping For Nerp Project Including Tpi Charges As Specified In Material Requisition. , Gate Valve Ss Dual, 150,0, Api 600/603, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, A351 Gr.Cf3/Cf8, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, Shall Be Dual Certified And The, Maximum Carbon Content Shall Be 0.03% , Gate Valve Ss Dual, 150,0, Api 600/603, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, A351 Gr.Cf3/Cf8, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, Shall Be Dual Certified And The, Maximum Carbon Content Shall Be 0.03% , Gate Valve Ss Dual, 300,0, Api 600/603, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, A351 Gr.Cf3/Cf8, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, Shall Be Dual Certified And The, Maximum Carbon Content Shall Be 0.03% , Gate Valve Ss Dual (H2 Ser.), 600,0, Api 600/603, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, A351 Gr.Cf3/Cf8, Dual Ss 304/304L, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, Shall Be Dual Certified And The, Maximum Carbon Content Shall Be 0.03% , Gate Valve Ss Dual, 150,0, Api 600/603, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, A351 Gr.Cf3m/8M, Dual Ss 316/316L, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, Shall Be Dual Certified And The, Maximum Carbon Content Shall Be 0.03% , Gate Valve Ss Dual, 150,0, Api 600/603, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, A351 Gr.Cf3m/8M, Dual Ss 316/316L, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, Shall Be Dual Certified And The, Maximum Carbon Content Shall Be 0.03% , Gate Valve Ss Dual, 150,0, Api 600/603, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, A351 Gr.Cf3m/8M, Dual Ss 316/316L, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, Shall Be Dual Certified And The, Maximum Carbon Content Shall Be 0.03% , Gate Valve Ss Dual, 300,0, Api 600/603, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, A351 Gr.Cf3m/8M, Dual Ss 316/316L, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, Shall Be Dual Certified And The, Maximum Carbon Content Shall Be 0.03% , Gate Valve Ss Dual, 600,0, Api 600/603, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, A351 Gr.Cf3m/8M, Dual Ss 316/316L, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, Shall Be Dual Certified And The, Maximum Carbon Content Shall Be 0.03% , Gate Valve Ss, 300,0, Api 600/603, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, A351 Gr.Cf8c, Ss 347H, Flexible Graphite, Spwd Ss 321H+Thermi., A453 Gr.660,Cl.A, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, Carbon Content Shall Be 0.04% Or Higher , Group-4(Group Wise Evaluation) Supply Of Gate Valve (Ext.Bonnet_Ltcs & Nace) For Ag+Ug Piping For Nerp Project Including Tpi Charges As Specified In Material Requisition. , Gate Valve Ext. Bonnet Ltcs, 150,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Ext. Bonnet Ltcs, 150,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Ext. Bonnet Ltcs, 150,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Ext. Bonnet Ltcs, 150,0, Api 600, Flgd,B16.47 Ser-A, Rf, Bb, Bolted Gland, Go, With Locking Arrangement, Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Ext. Bonnet Ltcs, 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Ext. Bonnet Ltcs, 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Ext. Bonnet Ltcs, 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Ext. Bonnet Ltcs, 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Vlv Ext.Bonnet Ltcs(A+C), 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), Amine+Caustic, A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Vlv Ext.Bonet Ltcs(A+C+H2, 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), Amine+Caustic+H2, A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Vlv Ext.Bonet Ltcs(A+C+H2, 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), Amine+Caustic+H2, A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gateval Ext. Bonnet Ltcs(Nace), 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Grl7m/A194 Gr7m, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Gateval Ext. Bonnet Ltcs(Nace), 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Grl7m/A194 Gr7m, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Gateval Ext. Bonnet Ltcs(Nace), 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Grl7m/A194 Gr7m, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Gate Valve Ext. Bonnet Ltcs, 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Go, With Locking Arrangement, Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Ext. Bonnet Ltcs, 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Go, With Locking Arrangement, Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Ext. Bonnet Ltcs, 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Go, With Locking Arrangement, Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Ext. Bonnet Ltcs, 600,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Ext. Bonnet Ltcs, 600,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gateval Ext. Bonnet Ltcs(Nace), 600,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Grl7m/A194 Gr7m, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Gate Valve Ext. Bonnet Ltcs, 600,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Go, With Locking Arrangement, Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Group-5(Group Wise Evaluation) Supply Of Gate Valve (With Purge) For Ag+Ug Piping For Nerp Project Including Tpi Charges As Specified In Material Requisition. , Gate Valve With Purge As, 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., A217 Gr.C12, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Grb16/A194gr.16, Supp. Requirements, Valve Shall Be Supplied With Auxiliary, S At Location “G” & “H” As Per, Figure 1 Of Asme B16.34 (Ed.2017) And Size, Shall Be As Per Para 6.3.6 Of Asme B16.34, (Ed.2017). Endof Auxiliary, S Is Flanged With 100Mm Nipple, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009 , Group-6(Group Wise Evaluation) Supply Ofgate Valve_Cs (Caustic&Nace+Caustic) For Ag+Ug Piping For Nerp Project Including Tpi Charges As Specified In Material Requisition. , Gate Valve Cs (Caustic), 150,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., A216 Gr.Wcb, 9, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs (Caustic), 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., A216 Gr.Wcb, 9, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs (Caustic), 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., A216 Gr.Wcb, 9, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs (Nace+Caustic), 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, A216 Gr.Wcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A193grb7m/A194 Gr2hm, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Gate Valve Cs (Nace+Caustic), 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, A216 Gr.Wcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A193grb7m/A194 Gr2hm, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Gate Valve Cs (Nace+Caustic), 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, A216 Gr.Wcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A193grb7m/A194 Gr2hm, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Group-7(Group Wise Evaluation) Supply Of Gate Valve Cs (H2 Service)(Nace+H2 Service) For Ag+Ug Piping For Nerp Project Including Tpi Charges As Specified In Material Requisition. , Gate Valve Cs (Nace+H2), 150,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, A216 Gr.Wcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A193grb7m/A194 Gr2hm, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Gate Valve Cs (Nace+H2), 150,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, A216 Gr.Wcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A193grb7m/A194 Gr2hm, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Gate Valve Cs (Nace+H2), 150,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, A216 Gr.Wcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A193grb7m/A194 Gr2hm, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Gate Valve Cs (H2 Ser.), 150,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Go, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs (H2 Ser.), 150,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Go, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs (H2 Ser.), 150,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Go, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs (H2 Ser.), 150,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs (H2 Ser.), 150,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs (Nace+H2), 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, A216 Gr.Wcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A193grb7m/A194 Gr2hm, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Gate Valve Cs (Nace+H2), 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, A216 Gr.Wcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A193grb7m/A194 Gr2hm, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Gate Valve Cs (Nace+H2), 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, A216 Gr.Wcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A193grb7m/A194 Gr2hm, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Gate Valve Cs (H2 Ser.), 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Go, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs (H2 Ser.), 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs (H2 Ser.), 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs (H2 Ser.), 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs (H2 Ser.), 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs (Nace+H2), 600,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, A216 Gr.Wcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A193grb7m/A194 Gr2hm, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Gate Valve Cs (Nace+H2), 600,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, A216 Gr.Wcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A193grb7m/A194 Gr2hm, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Gate Valve Cs (H2 Ser.), 600,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Group-8(Group Wise Evaluation) Supply Of Gate Valve_Cs Nace For Ag+Ug Piping For Nerp Project Including Tpi Charges As Specified In Material Requisition. , Gate Valve Cs (Nace), 150,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, A216 Gr.Wcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A193grb7m/A194 Gr2hm, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Gate Valve Cs (Nace), 150,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, A216 Gr.Wcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A193grb7m/A194 Gr2hm, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Gate Valve Cs (Nace), 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, A216 Gr.Wcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A193grb7m/A194 Gr2hm, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Gate Valve Cs (Nace), 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, A216 Gr.Wcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A193grb7m/A194 Gr2hm, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Gate Valve Cs (Nace), 600,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, A216 Gr.Wcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A193grb7m/A194 Gr2hm, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Gate Valve Cs (Nace), 600,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, A216 Gr.Wcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A193grb7m/A194 Gr2hm, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Group-9(Group Wise Evaluation) Supply Of Gate Valve Ibr_Cs For Ag+Ug Piping For Nerp Project Including Tpi Charges As Specified In Material Requisition. , Gate Valve Cs (Ibr), 600,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, Ibr Certificate As Per Specification For, Valves , Gate Valve Cs (Ibr), 600,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, Ibr Certificate As Per Specification For, Valves , Gate Valve Cs (Ibr), 150,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, Ibr Certificate As Per Specification For, Valves , Gate Valve Cs (Ibr), 150,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, Ibr Certificate As Per Specification For, Valves , Gate Valve Cs (Ibr), 150,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, Ibr Certificate As Per Specification For, Valves , Gate Valve Cs (Ibr), 150,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, Ibr Certificate As Per Specification For, Valves , Gate Valve Cs (Ibr), 150,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Go, With Locking Arrangement, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, Ibr Certificate As Per Specification For, Valves , Gate Valve Cs (Ibr), 150,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Go, With Locking Arrangement, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, Ibr Certificate As Per Specification For, Valves , Group-10(Group Wise Evaluation) Supply Of Gate Valvefor Ag+Ug Piping For Nerp Project Including Tpi Charges As Specified In Material Requisition. , Gate Valve Cs, 150,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs, 150,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs, 150,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs, 150,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Go, With Locking Arrangement, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs, 150,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Go, With Locking Arrangement, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs, 150,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Go, With Locking Arrangement, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs, 150,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Go, With Locking Arrangement, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs, 150,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Go, With Locking Arrangement, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs, 150,0, Asme B16.34, Flgd,B16.47 Ser-A, Rf, Bb, Bolted Gland, Go, With Locking Arrangement, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L+ Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs, 150,0, Asme B16.34, Flgd,B16.47 Ser-A, Rf, Bb, Bolted Gland, Go, With Locking Arrangement, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L+ Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs, 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs, 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs, 300,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Ho, With Locking Arrangement, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Gate Valve Cs, 600,0, Api 600, Flgd,B16.5, Rf, Bb, Bolted Gland, Go, With Locking Arrangement, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Group-11(Group Wise Evaluation) Supply Of Globe Valve For Ag+Ug Piping For Nerp Project Including Tpi Charges As Specified In Material Requisition. , Globe Valve Cs Int. Coated, 300,0, Api 623, Flgd,B16.5, Ff, Bb,Ho,Loose Plug/Ball Disc, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, Internally Liquid Epoxy Coated Acc. To, Doc. Nr-0Zzzz-Cv-Spe-0019 , Globe Valve Cs (Galv.), 150,0, Api 623, Flgd,B16.5, Ff, Bb,Ho,Loose Plug/Ball Disc, A216 Gr.Wcb(Galv.), 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Globe Valve Cs, 150,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Globe Valve Cs, 150,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Globe Valve Cs, 150,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Globe Valve Cs (H2 Ser.), 150,0, Api 623, Flgd,B16.5, Rf, Bb,Go,Loose Plug/Ball Disc, All Welds Shall Be Subjected, To Pwht., A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Globe Valve Cs (H2 Ser.), 150,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, All Welds Shall Be Subjected, To Pwht., A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Globe Valve Cs (Nace), 150,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, A216 Gr.Wcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A193grb7m/A194 Gr2hm, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Globe Valve Cs (Nace), 150,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, A216 Gr.Wcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A193grb7m/A194 Gr2hm, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Globe Valve Cs (Nace+Caustic), 150,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, A216 Gr.Wcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A193grb7m/A194 Gr2hm, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Globe Valve Cs (Nace+Caustic), 150,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, A216 Gr.Wcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A193grb7m/A194 Gr2hm, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Globe Valve Cs, 300,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Globe Valve Cs, 300,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Globe Valve Cs, 300,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Globe Valve Cs, 300,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Globe Valve Cs, 300,0, Api 623, Flgd,B16.5, Rf, Bb,Go,Loose Plug/Ball Disc, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Globe Valve Cs (H2 Ser.), 300,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, All Welds Shall Be Subjected, To Pwht., A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Globe Valve Cs (H2 Ser.), 300,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, All Welds Shall Be Subjected, To Pwht., A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Globe Valve Cs (Nace), 300,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, A216 Gr.Wcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A193grb7m/A194 Gr2hm, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Globe Valve Cs (Nace), 300,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, A216 Gr.Wcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A193grb7m/A194 Gr2hm, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Globe Valve Cs, 600,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Globe Valve Cs (Nace+H2), 600,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, A216 Gr.Wcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A193grb7m/A194 Gr2hm, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Globe Valve Cs, 600,0, Api 623, Flgd,B16.5, Rf, Bb,Go,Loose Plug/Ball Disc, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Globe Valve Ext. Bonnet Ltcs, 300,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Globe Valve Ext. Bonnet Ltcs, 300,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Globe Valve Ext. Bonnet Ltcs, 300,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Globe Valve Ext. Bonnet Ltcs, 300,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Globe Valve Ext. Bonnet Ltcs, 300,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Globevlv Ext.Bonet Ltcs(A+C+H2, 300,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, All Welds Shall Be Subjected, To Pwht., Amine+Caustic+H2, Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Globe V.Ext. Bonnet Ltcs(Nace), 300,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Grl7m/A194 Gr7m, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Globe Valve Ext. Bonnet Ltcs, 300,0, Api 623, Flgd,B16.5, Rf, Bb,Go,Loose Plug/Ball Disc, Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Globe Valve Ext. Bonnet Ltcs, 600,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Globe Valve Ext. Bonnet Ltcs, 600,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Globe Valve Ext. Bonnet Ltcs, 600,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, Ext. Bonnet Acc. To Bs 6364, (Non-Cold Box Application), A352 Gr.Lcb, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Globe Valve Ss Dual, 300,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, A351 Gr.Cf3/Cf8, 12, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, Shall Be Dual Certified And The, Maximum Carbon Content Shall Be 0.03% , Globe Valve Ss Dual, 150,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, A351 Gr.Cf3m/8M, Dual Ss 316/316L, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, Shall Be Dual Certified And The, Maximum Carbon Content Shall Be 0.03% , Globe Valve Ss, 300,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, A351 Gr.Cf8c, Ss 347, Flexible Graphite, Sp Wd Ss 321 + Grph, A453 Gr.660,Cl.A, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009 , Globe Valve Ss, 300,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, A351 Gr.Cf8c, Ss 347, Flexible Graphite, Sp Wd Ss 321 + Grph, A453 Gr.660,Cl.A, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009 , Globe Valve Ss (H2 Ser.), 300,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, A351 Gr.Cf8c, Ss 347, Flexible Graphite, Sp Wd Ss 321 + Grph, A453 Gr.660,Cl.A, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009 , Globe Valve Ss (H2 Ser.), 600,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, A351 Gr.Cf8c, Ss 347, Flexible Graphite, Sp Wd Ss 321 + Grph, A453 Gr.660,Cl.A, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009 , Globe Valve As, 300,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, All Welds Shall Be Subjected, To Pwht., A217 Gr.C5, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Grb16/A194gr.16, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009 , Globe Valve As, 300,0, Api 623, Flgd,B16.5, Rf, Bb,Go,Loose Plug/Ball Disc, All Welds Shall Be Subjected, To Pwht., A217 Gr.C5, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Grb16/A194gr.16, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009 , Globe Valve As, 300,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, All Welds Shall Be Subjected, To Pwht., A217 Gr.C12, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Grb16/A194gr.16, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009 , Globe Valve As, 300,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, All Welds Shall Be Subjected, To Pwht., A217 Gr.C12, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Grb16/A194gr.16, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009 , Globe Valve With Purge As, 300,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, All Welds Shall Be Subjected, To Pwht., A217 Gr.C12, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Grb16/A194gr.16, Supp. Requirements, Valve Shall Be Supplied With Auxiliary, S At Location “G” & “F” As Per, Figure 1 Of Asme B16.34 (Ed.2017) And Size, Shall Be As Per Para 6.3.6 Of Asme B16.34, (Ed.2017). Endof Auxiliary, S Is Flanged With 100Mm Nipple, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009 , Globe Valve Cs (Ibr), 600,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, Ibr Certificate As Per Specification For, Valves , Globe Valve Cs (Ibr), 300,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, Ibr Certificate As Per Specification For, Valves , Globe Valve Cs (Ibr), 300,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, Ibr Certificate As Per Specification For, Valves , Globe Valve Cs (Ibr), 300,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, A216 Gr.Wcb, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, Ibr Certificate As Per Specification For, Valves , Globe Valve As (Ibr), 600,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, All Welds Shall Be Subjected, To Pwht., A217 Gr.Wc6, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Grb16/A194gr.16, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, Ibr Certificate As Per Specification For, Valves , Globe Valve As (Ibr), 600,0, Api 623, Flgd,B16.5, Rf, Bb,Ho,Loose Plug/Ball Disc, All Welds Shall Be Subjected, To Pwht., A217 Gr.Wc6, 5, Flexible Graphite, Sp Wd Ss 316L + Grph, A193 Grb16/A194gr.16, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, Ibr Certificate As Per Specification For, Valves , Group-12(Group Wise Evaluation) Supply Ofvalve Check For Ag+Ug Piping For Nerp Project Including Tpi Charges As Specified In Material Requisition. , Swing Chk Valve Cs, 150,0, Api 594, Flgd,B16.5, Rf, Swing Type, Bolted Cover, A216 Gr.Wcb, 5, .Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Tilting Disc Chk Valcs Nace+H2, 300,0, Mfr. Std., Flgd,B16.5, Rf, Designnon-Slam Type., Bolted Cover, Tilting Disc Chk Valve, Installation Horiz. Pipeline, Pr-Temp. Ratingasme B16.34, Leakage Rate As Per Api 598, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, A216 Gr.Wcb, 12, .Sp Wd Ss 316L + Grph, A193grb7m/A194 Gr2hm, Spring Inconel X-750, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Swing Chk Valve Cs, 150,0, Api 594, Flgd,B16.5, Rf, Swing Type, Bolted Cover, A216 Gr.Wcb, 5, .Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Swing Chk Valve Cs, 150,0, Api 594, Flgd,B16.5, Rf, Swing Type, Bolted Cover, A216 Gr.Wcb, 5, .Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Swing Chk Valve Cs, 150,0, Api 594, Flgd,B16.5, Rf, Swing Type, Bolted Cover, A216 Gr.Wcb, 5, .Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Swing Chk Valve Cs (H2 Ser.), 150,0, Api 594, Flgd,B16.5, Rf, Swing Type, Bolted Cover, All Welds Shall Be Subjected, To Pwht., A216 Gr.Wcb, 5, .Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Swing Chk Valve Cs (Nace), 150,0, Api 594, Flgd,B16.5, Rf, Swing Type, Bolted Cover, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, A216 Gr.Wcb, 12, .Sp Wd Ss 316L + Grph, A193grb7m/A194 Gr2hm, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Swing Chk Valve Cs, 300,0, Api 594, Flgd,B16.5, Rf, Swing Type, Bolted Cover, A216 Gr.Wcb, 5, .Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Swing Chk Valve Cs, 300,0, Api 594, Flgd,B16.5, Rf, Swing Type, Bolted Cover, A216 Gr.Wcb, 5, .Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Swing Chk Valve Cs (Nace+H2), 300,0, Api 594, Flgd,B16.5, Rf, Swing Type, Bolted Cover, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, A216 Gr.Wcb, 12, .Sp Wd Ss 316L + Grph, A193grb7m/A194 Gr2hm, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Swing Chk Valve Cs (H2 Ser.), 300,0, Api 594, Flgd,B16.5, Rf, Swing Type, Bolted Cover, All Welds Shall Be Subjected, To Pwht., A216 Gr.Wcb, 5, .Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Swing Chk Val Cs(Nace+Caustic), 300,0, Api 594, Flgd,B16.5, Rf, Swing Type, Bolted Cover, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, A216 Gr.Wcb, 12, .Sp Wd Ss 316L + Grph, A193grb7m/A194 Gr2hm, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Swing Chk Val Cs(Nace+Caustic), 300,0, Api 594, Flgd,B16.5, Rf, Swing Type, Bolted Cover, All Welds Shall Be Subjected, To Pwht., Servicenace, Category 1, A216 Gr.Wcb, 12, .Sp Wd Ss 316L + Grph, A193grb7m/A194 Gr2hm, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, For Sour(Nace) Service Req. Acc. To, Nace Mr0103,Nr-0Zzzz-Pi-Spe-0025 And In-043 , Swing Chk Valve Cs, 600,0, Api 594, Flgd,B16.5, Rf, Swing Type, Bolted Cover, A216 Gr.Wcb, 5, .Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Swing Chk Valve Ltcs, 150,0, Api 594, Flgd,B16.5, Rf, Swing Type, Bolted Cover, A352 Gr.Lcb, 12, .Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Swing Chk Valve Ltcs, 150,0, Api 594, Flgd,B16.5, Rf, Swing Type, Bolted Cover, A352 Gr.Lcb, 12, .Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Swing Chk Valve Ltcs, 150,0, Api 594, Flgd,B16.5, Rf, Swing Type, Bolted Cover, A352 Gr.Lcb, 12, .Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Swing Chk Valve Ltcs, 300,0, Api 594, Flgd,B16.5, Rf, Swing Type, Bolted Cover, A352 Gr.Lcb, 12, .Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Swing Chk Valve Ltcs, 600,0, Api 594, Flgd,B16.5, Rf, Swing Type, Bolted Cover, A352 Gr.Lcb, 12, .Sp Wd Ss 316L + Grph, A320 Gr.L7/A194 Gr.4, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042 , Swing Chk Valve Ss Dual, 150,0, Api 594, Flgd,B16.5, Rf, Swing Type, Bolted Cover, A351 Gr.Cf3/Cf8, Dual Ss 304/304L+Hf, .Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, Shall Be Dual Certified And The, Maximum Carbon Content Shall Be 0.03% , Swing Chk Valve Ss Dual (Nace), 150,0, Api 594, Flgd,B16.5, Rf, Swing Type, Bolted Cover, Servicenace, Category 1, A351 Gr.Cf3/Cf8, 12, .Sp Wd Ss 316L + Grph, A193grb7m/A194 Gr2hm, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, Shall Be Dual Certified And The, Maximum Carbon Content Shall Be 0.03%, For Sour(Nace) Service Req. Acc. To, Nace Mr0103 , Swing Chk Valve Ss Dual, 600,0, Api 594, Flgd,B16.5, Rf, Swing Type, Bolted Cover, A351 Gr.Cf3m/8M, Dual Ss 316/316L+Hf, .Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, Shall Be Dual Certified And The, Maximum Carbon Content Shall Be 0.03% , Swing Chk Valve Ss (H2 Ser.), 600,0, Api 594, Flgd,B16.5, Rf, Swing Type, Bolted Cover, A351 Gr.Cf8c, 17, .Sp Wd Ss 321 + Grph, A453 Gr.660,Cl.A, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009 , Swing Chk Valve As, 300,0, Api 594, Flgd,B16.5, Rf, Swing Type, Bolted Cover, All Welds Shall Be Subjected, To Pwht., A217 Gr.C5, 5, .Sp Wd Ss 316L + Grph, A193 Grb16/A194gr.16, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009 , Swing Chk Valve As (H2 Ser.), 600,0, Api 594, Flgd,B16.5, Rf, Swing Type, Bolted Cover, All Welds Shall Be Subjected, To Pwht., A217 Gr.Wc6, 5, .Sp Wd Ss 316L + Grph, A193 Grb16/A194gr.16, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009 , Swing Chk Valve Cs (Ibr), 150,0, Api 594, Flgd,B16.5, Rf, Swing Type, Bolted Cover, A216 Gr.Wcb, 5, .Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, Ibr Certificate As Per Specification For, Valves , Swing Chk Valve Cs (Ibr), 150,0, Api 594, Flgd,B16.5, Rf, Swing Type, Bolted Cover, A216 Gr.Wcb, 5, .Sp Wd Ss 316L + Grph, A193 Gr.B7/A194gr.2H, Add. Information, Documents To Be Followed, Tk-1Zzza-Pi-Spe-0005,Tk-1Zzza-Pi-Spe-0006,, Tk-1Zzza-Pi-Spe-0008,Tk-1Zzza-Pi-Spe-0009, And In-042, Ibr Certificate As Per Specification For, Valves => Limited

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail