| 1 | Internal Electrification Work at CSS Lab, Bhadbhada, Bhopal. |
| 2 | Supply of ISI marked and accepted standard of miniaturecircuit breaker (MCB) of \"D\" series with short circuitindication, suitable for 240/415 Volts,50 Cycle, 10kA/15 kA Value AC supply conforming to IS : 8828 :1996, IEC : 60898 :2002 & 60947-2 but withoutenclosures :-MCB FP 50Amp to 63 Amp 10kA rating |
| 3 | Supply of ISI marked and accepted standard of miniaturecircuit breaker (MCB) of \"D\" series with short circuitindication, suitable for 240/415 Volts,50 Cycle, 10kA/15 kA Value AC supply conforming to IS : 8828 :1996, IEC : 60898 :2002 & 60947-2 but withoutenclosures :-MCB DP 6Amp to 32Amp 10kA rating |
| 4 | Supply of ISI marked and accepted standard of miniaturecircuit breaker (MCB) of \"D\" series with short circuitindication, suitable for 240/415 Volts,50 Cycle, 10kA/15 kA Value AC supply conforming to IS : 8828 :1996, IEC : 60898 :2002 & 60947-2 but withoutenclosures :-MCB SP 6Amp to 32Amp 10kA rating |
| 5 | Supplying and drawing single core PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing rigid PVC casing and capping/conduit in surface or concealed as per specification. 1.5 sq. mm. wire 1 X 1.5 sq. mm. |
| 6 | Supplying and drawing single core PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing rigid PVC casing and capping/conduit in surface or concealed as per specification. 2.5 sq. mm. wire 1 X 2.5 sq. mm. |
| 7 | Supplying and drawing single core PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing rigid PVC casing and capping/conduit in surface or concealed as per specification. 4.00 sq. mm. wire 1 X 4.00 sq. mm. |
| 8 | Supplying and drawing single core PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing rigid PVC casing and capping/conduit in surface or concealed as per specification. 6.00 sq. mm. wire 1 X 6.00 sq. mm. |
| 9 | Supply and fixing as per specification Switch of approved make ISI marked with necessary material complete. 16/20Amp SP 250 Volt modular switch |
| 10 | Supply and fixing as per specification Switch of approved make ISI marked with necessary material complete. 10/16/20Amp 250 Volt 3 Pin modular type |
| 11 | Pointwiring(excludingmetallicswitchbox&sheetbutincludingswitches,sockets,lampholders/ceilingrosesetc)with1.5sq.mm.PVCinsulatedcableFRLSwithcoppermultistrandconductorISImarkedinexistingconcealedrigidconduitISImarkedofsuitablesizewithPVCinsulaedFRLScopperearthcontinuityconductorofgreencolour,screwlessconnectorforjointsasperspecificationincludingearthing of regulator etc as required for :-Short point |
| 12 | Pointwiring(excludingmetallicswitchbox&sheetbutincludingswitches,sockets,lampholders/ceilingrosesetc)with1.5sq.mm.PVCinsulatedcableFRLSwithcoppermultistrandconductorISImarkedinexistingconcealedrigidconduitISImarkedofsuitablesizewithPVCinsulaedFRLScopperearthcontinuityconductorofgreencolour,screwlessconnectorforjointsasperspecificationincludingearthing of regulator etc as required for :-Medium point |
| 13 | Pointwiring(excludingmetallicswitchbox&sheetbutincludingswitches,sockets,lampholders/ceilingrosesetc)with1.5sq.mm.PVCinsulatedcableFRLSwithcoppermultistrandconductorISImarkedinexistingconcealedrigidconduitISImarkedofsuitablesizewithPVCinsulaedFRLScopperearthcontinuityconductorofgreencolour,screwlessconnectorforjointsasperspecificationincludingearthing of regulator etc as required for :-Long point |
| 14 | Pointwiring(excludingmetallicswitchbox&sheet)for3Pin16Amp.socketoutletpointwith4sq.mm.PVCinsulatedcableFRLSwithcoppermultistrandconductorISImarkedinconcealedrigidP.V.C.conduit(HMS)ISImarkedofsuitablesizeetc.with20/16Amp.F.T.switch&socket/S.S.combined20/16/6Amp.ofISImarkedand4sq.mm.PVCinsulatedFRLScopperearthcontinuityconductorofgreencolourinsideconduit,screwlessconnector for joints as per specification for :- Power point wiring concealed rigid P.V.C. conduit Power point On separate board - Short point |
| 15 | Pointwiring(excludingmetallicswitchbox&sheet)for3Pin16Amp.socketoutletpointwith4sq.mm.PVCinsulatedcableFRLSwithcoppermultistrandconductorISImarkedinconcealedrigidP.V.C.conduit(HMS)ISImarkedofsuitablesizeetc.with20/16Amp.F.T.switch&socket/S.S.combined20/16/6Amp.ofISImarkedand4sq.mm.PVCinsulatedFRLScopperearthcontinuityconductorofgreencolourinsideconduit,screwlessconnector for joints as per specification for :- Power point wiring concealed rigid P.V.C. conduit Power point On separate board - Medium point |
| 16 | Pointwiring(excludingmetallicswitchbox&sheet)for3Pin16Amp.socketoutletpointwith4sq.mm.PVCinsulatedcableFRLSwithcoppermultistrandconductorISImarkedinconcealedrigidP.V.C.conduit(HMS)ISImarkedofsuitablesizeetc.with20/16Amp.F.T.switch&socket/S.S.combined20/16/6Amp.ofISImarkedand4sq.mm.PVCinsulatedFRLScopperearthcontinuityconductorofgreencolourinsideconduit,screwlessconnector for joints as per specification for :- Power point wiring concealed rigid P.V.C. conduit Power point On separate board - Long point |
| 17 | Same board switch & socket 16 Amp./S.S. combined 20/16/6 Am |
| 18 | Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in concealedrigid P.V.C. conduit (HMS) of ISI marked suitable size etc. as required as per specification. 4x2.5 Sq.mm. |
| 19 | Supply and fixing Led tube rod comprising of LED tube with non integral/integral driver, upto 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with system efficacy> 100 lm/Watt. LED driver PF> 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. Tube light LED 1 X 20/22Watt, Integral i/c batten aluminium body, PC diffuser. |
| 20 | Supplying and fixing of approved make modular type G.I.metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earthterminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:- 1Or 2 Module metal box |
| 21 | Supplying and fixing of approved make modular type G.I.metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earthterminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:- 3 Module metal box |
| 22 | Supplying and fixing of approved make modular type G.I.metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earthterminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:- 12 Module metal box |
| 23 | Supplying and fixing of approved make modular type G.I.metal box 1.2mm minimum thick and depth 50mm for single row boxes and 60mm depth for two/three row boxes earthterminal stud with nut and washer with modular base and cover plate including fixing in concealed etc. as required for:-18 Module metal box |
| 24 | Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:- 3 Module PVC box |
| 25 | Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:- 12 Module PVC box |
| 26 | Supply and fixing of approved make step type modular electronic fan regulator including connection etc. as required on existing board. 100 Watt(2 module) |
| 27 | Supplying and fixing PVC casing and capping (double fold) ISI marked along with accessories on surface etc. as required. PVC casing and capping (double fold) 50 mm x 16mm |
| 28 | Supplying and fixing PVC casing and capping (double fold) ISI marked along with accessories on surface etc. as required. PVC casing and capping (double fold) 38 mm x 20mm |
| 29 | Supplying and fixing PVC casing and capping (double fold) ISI marked along with accessories on surface etc. as required. PVC casing and capping (double fold) 32 mm x 12mm |
| 30 | Supply and fixing of approved make 3 pin plug top ISI marked - 16Amp 250Volt 3 Pin top |
| 31 | Supply and erection of approved make safe earthing electrode consisting pipe-in-pipe technology as per IS3043-1987 made of corrosion free G.I.pipes with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for effective and maintenance free erthing in earth pit of minimum bore dia.150 mm size,as mentioned below : |
| 32 | Supply and laying 25mm X 6mm G.I. Strip at 0.5 metre below ground level/surface as strip earth electrode including jointing etc. As required. |
| 33 | Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor 95sqmm3½core unarmoured |
| 34 | Layingofonenumberarmoured/unarmouredpowercable1.1KVgradeofsizeexceeding25sq.mmbutnotexceeding120sq.mmintheexistingmasonry open duct as required. |
| 35 | Supply of support for overhead line RS joist of I.S.standard including drilling of required hole etc.complete as required.R.S. Joist 100x200 - 25.4 kg/metre |
| 36 | Erection of RS Joist pole/\"H\" beam/steel tubular/steel rail pole of length 7 metres but not exceeding 10 metres in cement concrete 1:3:6 (1 cement : 3 core sand: 6 graded stone aggregate 40mm nominal size)base, foundation, muffing including excavationand backrefilling etc. as required. |
| 37 | Supplyinganderectionofstaysetcomplete(galvanized)19mm.diax1.8metrelongstayrodanchorplateofsize300mmx300mmx7.5mmthimblestayclamp,turnbuckle(19mmdiax600mm),7/4.00mmdiaG.I.staywireetc.incementconcreteM10(1Cement:3Coarsesand:6gradedstoneaggregate40mmnominalsize)foundationincludingexcavation and refilling etc. as required. |
| 38 | Supply, laying and fixing of G.I. earth coil of 4mm diaG.I. wire having 120 turns of nearly 50mm dia. and 3mt. long tail in existing pit duly earthed with pole etccomplete as required as per specification. |
| 39 | Dismantling&shifting,installation,testing&commissioningofsplitairconditioningunit1.0TR/1.5TR/2TRcapacityincludingindoor/outdoor unit complete as required within town. |
| 40 | Supply,installation,testing&commissioningofsuction/dischargecopperpipelineinsplitairconditioningunit1.0/1.5TR/2TR/3TRcapacityincludingbrazing,nitrilerubberinsulation6/9mmthick class \"O\", etc complete as required.46.3.1Copper tube 1/4\" |
| 41 | Supplying of ISI Marked Change over switches in sheet enclosure confirming to IS : 4064 / IS : 13947 (part I & III ) with side handle operated 4 pole with two earthing terminals100 Amps. 415/500 Volts. (off load ) |
| 42 | Supply,installation,testing&commissioningofsuction/dischargecopperpipelineinsplitairconditioningunit1.0/1.5TR/2TR/3TRcapacityincludingbrazing,nitrilerubberinsulation6/9mmthick class \"O\", etc complete as required.46.3.1Copper tube 1/2\" |
| 43 | chargingGascharging(R410A/EcoFriendlyGreenGas)ofwindow/splitairconditioningunitincludingflushingofcooling&condensingunitswithnitrogengas&rectificationofleakage,replacementoffilter,flairnut etc. if any.1.5TR |