Tender For Replacement Of Damaged T F Control Panel And 33 Kv Vcb At 33 11 Kv Ss Vibhuti Khand S S And Installation Of Bus Isolator At 33 11 Kv Viraj Khand S S And Related Work On Semi Turnkey Basis As Per Stock Issue Rate 2024 25 Under Business Plan, Lucknow-Uttar Pradesh
TDR : 49146961
Tender Notice
Corrigendum Details
BOQ
Expired
Lucknow
Uttar Pradesh
Corrigendum : Tender For Replacement Of Damaged T F Control Panel And 33 Kv Vcb At 33 11 Kv Ss Vibhuti Khand S S And Installation Of Bus Isolator At 33 11 Kv Viraj Khand S S And Related Work On Semi Turnkey Basis As Per Stock Issue Rate 2024 25 Under Business Plan
Name of Work:Replacement of Damaged T/F Control Panel & 33 KV VCB at 33/11 KV SS Vibhuti Khand S/S and Installation of Bus Isolator at 33/11 KV Viraj Khand S/S and related work on Semi turnkey basis as per Stock Issue Rate 2024-25 Under Business Plan 2025-26.
Sl. No.
Item Description
1
Safe loading & carriage including & proper stracking of following store material from ESC Lucknow /JE store to site of work .
2
Panther Conductor
3
33 KV VCB 800 Amp 750 MVA
4
Single T/F Control Panel
5
33 KV BUS ISOLATOR 400/800 A
6
33 KV Composite Pin Insulator
7
Top Channel 125x65 sq mm
8
M.S.Angle 75x75x6, 2.6 Mtr, 2 Nos Total [email protected] Kg./M with wastage
9
Jumpering of VCB & Bus Isolator in switch yard with Panther conductor P.G.clams, Pin Insulator, M S Angle & proper size aluminium lugs including stringing Bus bar including sepration of earthing and re connection of earthing by means of M.S.Strip and paint it with green color. (All the material shall be provided by the contractor except Panther Conductor, Pin Insulator & M S angle )
10
Opening of Jumper from damaged VCB and shifting of Damaged VCB to another Place and Installation of 33KV VCB in place of damaged VCB with complete work including commissioning & Jumpring on existing Plinth.
11
Shifting carefully & installation of 33KV single feeder / transformer control panel in control room including its grouting and painting of Feeder/TF Name
12
FABRICATION ,ERECTION & GROUTING OF ISOLATOR STRUCTURE:- Fabrication of isolator structures 3.5 Mtr. In height as per drawing No. RES 39.Digging of two Nos.pits of size 1.075x0.9x0.3 Mtr. Providing stone pad at the bottom of the pit and grouting pad at the bottom of the pit and grouting of two legs of the isolator structure in CC (cement coarse sand and stone grit of 20m.m gauge)of the ratio 1:4:8 in block of 1.075 Mtrx0.3 mm including supply of all T&P complete in allrespect. Both plinths of the isolator structure shall be properly finished with smoothening of edges.
13
Assembling and installation of line / bus isolator on the isolator structure , In case of line isolator proper operator of earth links shall also be insured. The work includes fabrication for proper flexing if required.
14
Earthing by way of boring and lowering of \"B\" Class GI pipe 50 mm dia from ground upto the water level(minimum 30 mtr. Deep )as per standard practice(All material shall be provided by the contractor except the supplied items )as per resspo norms.
15
Dismantling Charges of 33 KV Panel/ T/F Control Panel/Feeder Control Panel with accessory etc. and carriage of receive back material from site to store ESC