| 1 | Earthworkinexcavationbymechanicalmeans(Hydraulic excavator)/manualmeansinfoundationtrenchesordrains(not exceeding 1.5 m in width or 10sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out theexcavatedsoilanddisposalofsurplusexcavatedsoilas directed, within a lead of 50 m All kinds of soil. |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6(1Cement:3coarsesand:6gradedstone aggregate 20 mm nominal size). |
| 3 | Centeringandshutteringincludingstrutting,proppingetc.and removal of form for : Foundations,footings,basesofcolumns,etc.for mass concrete. |
| 4 | Randomrubblemasonrywithhard stone in foundationand plinthincludinglevelling up withcementconcrete1:6:12(1 cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 5 | REINFORCED CEMENT CONCRETE WORK IN BEAMS, SUSPENDED FLOORS, ROOFS HAVING SLOPE UPTO 15 DEGREE, LANDINGS , BALCONIES, SHELVES, CHAJJAS, LINTELS, BANDS, PLAIN WINDOW SILLS, STAIRCASES AND SPIRAL STAIR CASES UPTO TO FLOOR FIVE LEVEL EXCLUDING THE COST OF CENTERING, SHUTTING AND REINFORCEMENTWITH 1:2:4 ( 1 CEMENT : 2 COARSE SAND : 4 GRADED STONE AGGREGATE 20 MM NOMINAL SIZE). |
| 6 | ReinforcementforR.C.C. workincludingstraightening,cutting, bending, placing in position and binding all complete. Cold twisted bars |
| 7 | Filling available excavated earth (excluding rock) in trenches, plinth, sidesoffoundationsetc.in layersnotexceeding20cmindepth, consolidating each depositedlayerby ramming andwatering, lead up to 50 m and lift upto 1.5 m. |
| 8 | STONE SOLING UNDER FLOOR INCLUDING FILLING VOIDS WITH STONE CHIPS AND SAND, RAMMING, WATERING AND CONSOLIDATING ETC. COMPLETE |
| 9 | BrickworkwithF.P.S.bricksofclassdesignation75in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 10 | 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) |
| 11 | 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) |
| 12 | White washing with lime to give an even shade: New work (three or more coats) |
| 13 | Structural steel work riveted bolted or welded in built up section, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 14 | Providing & Fixing Precoated galvanised iron profile /Trapezoidal profile sheets (Size, Shape and pitch of corrugation as approved by Engineer-In-Charge) manufactured out of 0.50 mm (0.05%)TCT with zinc coating 120 grams per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both sides of the sheet and polyester top coating 15-18 micron. Sheets should have protective guard film of 25 microns minimum to avoid scratches during transportation. The sheet shall be fixed using self-drilling/self-tapping screws size(5.50-8 x55 mm) with EPDM seal, complete upto any pitch in Horizontal/Vertical or curved surfaces, excluding the cost of purlins, rafters & trusses and including cutting to size and shape whenever required. |
| 15 | Painting with synthetic enamel paint of approvedbrandand manufacture to give an even shade: Two or more coats on new work |