| 1 | Demolition ofbrickwork or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facing, dressed stone work precast concrete articles and stacking the serviceable materials within 100m and disposal of unserviceable material, debris and rubbish to a distance not exceeding 10m complete all as specified and directed. |
| 2 | Demolition of cement concrete (unreinforced) in ground floor and in pavings in any thickness (below or aboveground level)complete all as specified and directed. |
| 3 | M&L PCC 1:3:6 Type C-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 4 | M&L PCC 1:3:6 Type C-2 (using 40mm graded crushed stone aggregate) as in surface channel or drains etc. complete all as specified and directed. |
| 5 | M&L plain cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate cast in situ in lintels up to 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, water through and the like including weathering, slightly rounded or chamfered angles and throating including use of form work (straight or curved) complete all as specified & directed. |
| 6 | M&L brick work with sub class \"B\" bricks, straight or curved on plan exc 6 m mean radius built in Cement mortar 1:4, complete all as specified and directed. |
| 7 | M&L walling of random rubble stone masonry uncoursed, with best quality locally available harder stones such as granite, trap, basalt stone etc. well bonded, bedded and solidly hearted, built in cement mortar 1:4 complete all as specified and directed. |
| 8 | All as per item No. 7 here-in-above but except stone.Note:Old stone obtained against demolition shall be used. |
| 9 | Extra over stone walling(Granite or trap stone)for hammer dressingwith maximum depression on face from a straight edge held against the dressed surface n exc exceeding 20mmand dressing to face beds and joints as specified of random rubble walling un-courses or brought upto coarse complete all as specified and directed. |
| 10 | S&F 100mm bore PVC (SWR) pipe of pressure rating 4 Kg/Sqcm fixed in retaining wall complete all as specified and directed. |
| 11 | M&L boulder filling dry, hand packed tightly, as in wire crate apron bunds (wire crate measured separately) complete all as specified and directed. |
| 12 | M&L hand packing (any thickness) of broken stone or boulders at back of walls over arches etc. and raising (or lowering) to the required level complete all as specified and directed. |
| 13 | S&F 4mm dia galvanised steel wire 100x100mm mesh, made up into mattresses or cages, lapped, wired and laid in position, including closing after filling complete all as specified and directed.Note:The rates include for placing in position, binding and joining edges etc. with 4mm steel wire to form complete mattresses. The mattresses shall be formed by looping the wires at each intersection complete all as specified. |
| 14 | Taking down cement plaster including tiles of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc.complete all as specified and directed. |
| 15 | M&L rendering 15mm thickplaster on old/new faces of brick work/stone/concrete surface in CM 1:4 finished the surface even and fair without using extra cement complete all as specified and directed. |
| 16 | Racking out joints/pointing to random rubble or polygonal rubble uncoursed or brought up to cources built in cement or cement lime mortar, scrubbing down with water etc and removal of rubbish off the premises and leaving the work clear of any pointing (keeping the surface to be pointed wet for 2 days prior to repointing) complete all as specified & directed. |
| 17 | M&L raised pointing to random or polygoned rubble walling, uncoursed, or brought upto course in CM 1:4 complete all as specified and directed. |
| 18 | M&L extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc. complete all as specified and directed.(inner girth only measured) |
| 19 | S&F 300mm dia internal reinforced concrete pipes, class NP3, laid and jointed with collars complete all as specified and directed. |
| 20 | M&L RCC (nominal mix) 1:2:4 type B1 (using 20mm graded stone aggregate) as in roof slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 21 | Form work to rough finished surfaces of concrete for soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. |
| 22 | S&F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 23 | M&L preparation of newly plastered or unplastered surface of walls and applying two coats of coloured cement base paint complete all as specified and directed. |