| 1 | Demolition of brick work or stone/boulder masonry, built in lime mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles built in cement mortar complete all as specified & directed. |
| 2 | M&L for Brick work with flyash bricks old size, straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 etc complete all as specified & directed. |
| 3 | M & L Brick work with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 complete all as specified & directed. |
| 4 | M & L plain cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in coping kneelers, apex stones, bed plates, kerbs, etc. complete all as specified and as directed. |
| 5 | Demolition of cement concrete (unreinforced) in ground floors and pavings, etc.n exc 15cm thickness (below or above ground level) and removing debris and rubbish out of the premises complete all as specified & directed. |
| 6 | M & L for plain cement concrete 1:2:4, type B-2 (using 40 mm graded stone aggregate) as in surface channels and drains, etc complete all as specified & directed. |
| 7 | Extra for forming fair finished of drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped complete all as specified & directed. |
| 8 | Taking down cement plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 9 | M&L for 15mm thick rendering in cement mortar 1:4 on brick or concrete surfaces of wall finished even & smooth complete all as specified and directed. |
| 10 | M&L for granite work (of any type) 20 (+/- 2) mm (table rubbed and polished) in pillars and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 11 | M&L for preparation of newly plastered wall surfaces and applying two coats of cement based paint over a coat of primer complete all as specified and as directed. |
| 12 | M&L for preparation of new or previuosly untreated plastered surfaces and applying two coats of synthetic enamel paint over a coat of pimer complete all as specified and as directed. (for footpath side wall paint of Black & White) |
| 13 | M&L for preparation of old painted plastered surfaces and applying one coat synthetic enamel paint complete all as specified and as directed. (for footpath side wall paint of Black & White) all as per directed and specified. |
| 14 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 15 | M&L for Precast Reinforced Cement Concete 1:2:4 (Nominal Mix) Type B-1 using 20 mm graded stone aggregate as in cover slabs (for man holes, drain etc.) set in Cement Mortar (1:4) including necessary form, mould work, etc. complete all as specified and as directed. |
| 16 | M&L Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 17 | Demolition of stone slabs and tiles laid, bedded and pointed in any mortar of any description or thickness in floors, aprons etc. complete all as specified and as directed. |
| 18 | Demolition of stone slabs and tiles laid dry of any description or thickness in floors, aprons etc. complete all as specified and as directed. |
| 19 | M&L for 40 mm thick plain cement concrete 1:2:4 type B 0 using 12.5 mm graded aggregate as in sub base to receive tiles all as per directed. |
| 20 | M&L for 15 mm thick screed bed or bedding layer for laying floor finishes in cement mortar 1:6 complete all as specified and as directed. |
| 21 | M&LPaving vitrified parking tiles 300 mm x 300 mm/400mm x 400mm of 8 to 10 mm thick (heavy duty), set, jointed and pointed in neat cement slurry as in foot path with white cement and pigments complete all as specified and as directed. |
| 22 | M&L for Chequered cement concrete tiles 30cm x 30cm x 25mm/ 40cm x 40cm x 25mm thick, pre-polished set, jointed and pointed in neat cement slurry with grey/colour cement and pigment in floors complete all as specified and as directed. |
| 23 | M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 grade with grey cement & pigment complete all as specified and as directed. |
| 24 | M & L for 50 mm thick sand filling under precast concrete inter locking paver floors including watering and consolidation complete all as specified and as directed. |
| 25 | M & L for 100 mm thick plain cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in hardstanding complete all as specified and as directed. |
| 26 | Forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘B’ for 100mm thick concrete slab complete all as specified and as directed. |
| 27 | M & L Precast Cement Concete louvres and jalli 1:3:6 (Nominal Mix) type B-0 using 12.5mm graded stone aggregate, set in Cement Mortar (1:4), 25 mm thick, including all moulding but excluding frame including demolition of old jalli complete all as specified and as directed. |
| 28 | Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified & directed. |
| 29 | S & F for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete with Fe-410- W(Gde- E-250) quality- B complete all as specified and as directed. |
| 30 | S & F for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified & directed. |
| 31 | M & L Preparing plastered/unplastered old surface of walls, chajja, facias etc by brooming down or steel wire brushing, scrapping down smoke soots, moulds, moss, efflorescent salts, treading oil, greasy spots or washing rubbing down andapplying one coat of cement base paint, white or tinted complete all as specified & directed. |
| 32 | M & L preparing plastered/unplastered old surface of walls, chajja, facias etc by brooming down or steel wire brushing, scrapping down smoke soots, moulds, moss, efflorescent salts, treading oil, greasy spots or washing rubbing down and applying two coat of cement base paint, white or tintedover a coat of alkali resistant primer complete all as specified & directed. |
| 33 | M & L Preparation of old painted surfaces of walls, cornices, chajjas, balcony, facia etc by brooming down or steel wire brushing, washing, rubbing downand applying one coat of exterior emulsion paint complete all as specified & directed. |
| 34 | Complete removal of existing treatment on old walls by washing ,rubbing down and stopping of distempred or painted surfaces and Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified & directed. |
| 35 | M & L preparing of old distempered surfaces including washing rubbing down and stopping of old distempered and painted surfaces including complete removal of existing treatment complete and applying two coats of oil bound distemper on walls after applying 2mm thick of wall care putty to obtain smooth surfaces complete all as specified & directed. |
| 36 | M & L for preparation of surfaces and applying one coat of oil bound distemper on old treated surface of wall etc complete all as specified and directed. |
| 37 | M & L for preparation of surfaces and applying two coat of oil bound distemperon old treated surface of wall etc complete all as specified and directed. |
| 38 | M & L for preparation of old treated surface of ceiling and applying one coat ofwhite wash completeall as specified and directed. |
| 39 | M & L for prepration of old treated steel surface of any description exceeding 10cm width or girth and applying one coat of synthetic enamelled paint ver roof sheet bldg ht 6 to 9 mtr complete all as specified and directed.(spray painting) |
| 40 | M & L for preparation of old treated wood or wood based surface of any description exceeding 10cm width or girth and applying one coat of synthetic enamel paintcomplete all as specified and directed. |
| 41 | M&L for obliterating old writing of any description, not exc 0.1 sqm with paint to match existing works complete all as specified and directed. |
| 42 | M&L for rewriting/repainting to existing writing letters or figures not exc 30 cm height in block Roman, Italian or Indian letters including stops, comma, arrows, brackets, dashes etc on sign board (Black or yellow base) including two coats of oil paint over a coat white basesynthetic enamel paint complete all as specified and directed. |
| 43 | Preparing new steel or iron surfaces of any descriptionover 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 44 | S & F MS steel work in tubular trusses and tubular posts including special shaped washersetc., complete using but welded tubes confirming to IS 1161- 1979 graded St 240 withone shop coat of zinc chromate primer paint complete all as specified & directed. |
| 45 | M&L for pre-painted galvalume aluminium zinc coating GI based corrugater steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 46 | S&F Pre- painted galvatume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in valley/gutter/eve board fixed with self tapping screws etc complete all as specified and as directed. |
| 47 | Dismantling plain or corrugated AC sheeting , any, thicknessor similar pattern roof coverings complete all as specified & directed. |