| 1 | Earth workinexcavationby manual means over areas (Exceeding30emandupto 1.5 mtr indepth,1.5 mtr in widthas wellas10 sqm.onplan)including disposal of excavated earth upto 1 mtr from cutting edge, disposed earthto belevelled andneatly dressedin:80%. All kinds of soils and 20% ordinary rock |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering , all works upto plinth level( 1 : 4 : 8) 1 cement 4 coasre sand 8 stone aggregate grade, with 40mm nominal size . crushed |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All works up to plinth level in (1:5:10) grade, with 40mm nominal size of (Crushed stone aggregates) |
| 4 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and nforcement. All works upto plinth level1:1½:3 (1 cement : 1½ coarse |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering , all works upto plinth level( 1 : 3 : 6)1 cement 3 coasre sand 6 stone aggregate grade , with 20mm nominalprotection work |
| 6 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal |
| 7 | Providing and laying Reinforced Cement Concrete 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) in suspended floors, balconies, landings and staircase having upto 15° slope. excluding cost of centering and shuttering , all work upto floor V level |
| 8 | Brick work with common burnt clay F.P.S (Non-modular) brick of class designation 75 in foundation and plinth in 1:6(1 cement : 6coarse sand) |
| 9 | Extra for brick work in Super structure above plinth level upto floor V level (By manual means) |
| 10 | Reinforcement of RCC work in Plinth band incl straightening, cutting, bending, placing in position and binding all complete. |
| 11 | Centering and shittering including strutting propping etc and removal of form workFoundation footingbases of columns etc |
| 12 | Centering and shittering including strutting propping etc and removal of form workcolumns etc piers butmentsposts and struts RCC Column :- |
| 13 | Providing and laying in position cement concrete of specified grade including curing butexcluding the cost of centring and shuttering. All work upto plinth level :1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 14 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand)including grouting the joints with white cement and matching pigments etc. completeSize of tile 600x600 mm |
| 15 | Centering and shuttering incl. struting, proping ,etc.and removal of form work for edges of slab under 20 cm |
| 16 | Centering and shuttering incl. struting, proping ,etc.and removal of form work for lentel beam plinth beam girders bressumers and centiliver lintel band2x 4x 11\"-0\" x0\"-6\"=44sfttotal 44 sft or 4.08 |
| 17 | Centering and shuttering incl. struting, proping ,etc.and removal of form work for suspended floors,roofing ,landings,balconies and access platform |
| 18 | 15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 ( 1 cement : 6 fine sand ) |
| 19 | 12 mm cement plaster on wall of mix 1:6 ( 1 cement 6 fine sand ) |
| 20 | 6mm cement plaster to ceiling of mix 1 : 3 (1 cement: 3 fine sand) |
| 21 | Providingwoodworkinframesofdoors,windows, clerestory windows and other frames, wrought framed and fixedin position with hold fast lugs or with dash fasteners of requireddiaandlength(holdfastlugsor withdash asteners shall be paid for separately): Sal wood |
| 22 | Providing and fixing paneled or glazed shutters for doors and windows and clestory windowsusing 10 kg /sqm (4mm thick) float glass panes including ISI marked black enameled M.S. butt hinges bright finished of requried size with necessary screws, (35mm thick of 2nd class deodar wood). |
| 23 | Providingandfixing35mmthickwiregauzeshutters usinggalvanised M.S.wire gauze of average widthfor aperture1.4 mminbothdirectoin with wire of dia.0.63 mmfordoors,windowsandclerestorywindowswith hinges andnecessary screws: Second class deodar wood. |
| 24 | Providingandfixingpanelledorpanelledandglazed shuttersfordoors,windowsandclerestorywindows includinglSImarkedM.S.pressedButthingesbright finished of required size with necessary screws excluding panelling which willbepaidfor separately,al!complete as per direction of engineer- in charge. Second class deodar wood . |
| 25 | Providingandfixingflat pressed3layer particleboard medium density exterior grade (Grade I)or graded wood particleboardIS:3087markedtoframe,backingor studding with screws etc. complete (Frames, backing or studdingto be paid separately): QTY VIDE ITEM NO 23 2.60 sqmx65%= 1.69 sqm |
| 26 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. |
| 27 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 gradedstone aggregate 20 mm nominal size). |
| 28 | Applying priming coat with ready mixed pink or grey primer of approved brand and manufactures on wood work (hard and soft wood) |
| 29 | Painting of doors and windows with ready mixed synthetic enamel paint of approved brand and manufacturers in all shades (two or more coats) on new work |
| 30 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1mm thick |
| 31 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 32 | FInishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 33 | Electric wiring with 1.5 sqmm copper cable including 20 mm dia 2mm thick PVC pipe 5amp with sunken box and connection to the main pole complete as directed by engineer-incharge. |
| 34 | Providing and Fxing aluminium tower bolt ISI marked anodized (anodic coating not less than grade AC as per IS 1868) transparent or dyed to required colouur or shade with necessary screws etc. complete 100X 10 MM |
| 35 | Providing and Fxing aluminium handleISI marked anodized (anodic coating not less than grade AC as per IS 1868)transparent or dyed to required colouur or shade with necessary screws etc. complete 100 MM |
| 36 | Providing and Fxing aluminium handleISI marked anodized (anodic coating not less than grade AC as per IS 1868)transparent or dyed to required colouur or shade with necessary screws etc. complete 125mm |
| 37 | Providing and fixing lSI marked oxidised M.S. sliding door bolts with nuts and screws etc. complet.e 300x16 mm |
| 38 | Demolishing stone rubble masonry manually/by mechanical means including stacking of serviceable material and disposal of unserviceable materialwithin 50 meters lead as per direction of Engineer-in-charge: In lime mortar |
| 39 | Providing and Fixing Foundation Stone as per direction by Engineer -Charge |
| 40 | Dismantling wood work in frames, trusses, purlins and rafters upto 10 meters span and 5 meters height including stackinOf sectional area 40 sqcm. and above. |
| 41 | Carriage of Sandby mechanical transport including loading , unloading & stacking complete lead upto 85 km and manual labour 100 meter |
| 42 | Carriage ofstone aggregatebelow 40 mm thick by mechanical transport including loading, unloading & stacking complete lead upto 15 km and manual labour100 meter |
| 43 | Carriage ofbricks by mechanical transport including loading, unloading & stacking complete lead upto 100 km and manual labour 100 meter |