Tender For Provision Of Certain Minor Works Under Ge Nams, Amritsar-Punjab

Military Engineer Services has published Tender For Provision Of Certain Minor Works Under Ge Nams. Submission Date for this Tender is 27-05-2025. Construction Material Tenders in Amritsar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

49122483
Tender For Provision Of Certain Minor Works Under Ge Nams
Tender
Indian
Punjab
Amritsar
27-05-2025

Tender Documents

Tender Details

Tender For Provision Of Certain Minor Works Under Ge Nams; 1 Material and labour for point wiringwith 1.5 sqmm (Nominal area ) 1100 Volt PVC Insulated , FRLS unsheathed and multi strandedcopper conductor cable in and including new PVC Concealed conduit 20mm dia 1.5mm thick for one light / fan point controlled by one switch (including cutting chases and making good the distributed surfaces) and fixing new 3mm thick hylem sheet top cover, sheet screws and sunken boxes included 1.5 Sqmm stranded copper conductor with green PVC Insulation earth contunity conductor connected to common earth dolly etcfor one light /fan/point controlled by one 5 Amp switch one waycomplete all as specified and directed. Note :(i)The cost ofsunken boxes and bakellite sheet is included in the quoted rate) (ii) On shed roof ceiling PVC conduit shall be provided on surfaces for any necessary pointwith proper fixing clips and no extra cost shall be paid for the job etcall as directed. 2 Material and labour for point wiring with 1.5 sqmm (Nominal area ) 1100 Volt PVC Insulated , FRLS unsheathed and multi strandedcopper conductor cable in old PVC Concealed conduitfor one light / fan point or bell point controlled by one switch (including cutting chases and making good the distributed surfaces) and fixing new 3mm thick plastic laminated sheet top cover, sheet screws and 1.6mm thick GI sunken boxes after removing old unserviceable plastic laminated sheeet and sunken boxes included 1.5 Sqmm stranded copper conductor with green PVC Insulation earth contunity conductor connected to common earth dolly etc . complete all as specified and directed Note : The cost ofsunken boxes and bakellite sheet is included in the quoted rate) 3 Material and labour for Point wiring with 2.5 Sqmm(Nominal Area) 1100 Volt Insulated, FRLS unsheathed multi stranded flexible copper conductor cable in and incl new PVC concealed conduit not less than 20 mm dia 1.5 mm thick for one light / fanpoint or bell pointcontrolled by one switch (including cutting chases and making good the distributed surface ) and fixing new 3 mm thick hylem sheet top cover, sheet screws and 1.6 mm thick GI sunken boxes included 2.5 sqmm stranded copper conductor with green PVC insulation earth contunity conductor connected to comman earth dolly etc. complete all as specified and directed for the following:- NOTE : The cost of sunken boxes and bakelite sheet is included in the quoted rate) 4 Supply and fixing of switch piano flush button single pole one-way 15 Ampere complete all as specified and directed. 5 Supply and fixing of socket outlet two-in-one, 3 pin each suitable for 5 and 15 Amperes flush type, 250 volts AC complete all as specified and directed. 6 Supply and Fixing switch piano type 6 Amps one way 230 volts ACcomplete all as specified and directed. 7 Supply and fixing ceiling rose 65X50 mm two to three terminals complete all as specified and directed. 8 Supply and fixing of MCB single pole 6 to 32 Amps complete all as specified and directed. 9 Supply & fixing single pole and neutral enclosure 32 A ,230 V with a two pin and earth plug and socket complete with one Singlepole MCB 25 A complete all as specified and directed. 10 Supply and fixing of MCB single pole and Neutral 32 Amps complete all as specified and directed. 11 Supply and fixing ceiling fans 1200mm sweep at 300/350 RPM copper winding high speed , aluminium body with blade , double ball bearing of BEE star rated includingall accessories connector , canopy, hanging rod upto 4 feet and clamps , including electric connection with PVC flexible twin core copper wire from ceiling rose to ceiling fan suitable for patient waiting shed of MI room of 2023 fd hosp complete all as specified and directed. 12 Supply and erection of LED type street light 25 watts IP 66 pressure die cast aluminiumalloy with high efficiency UV stablized with integreted Lens,system lumens 6600 with system efficancy of 135 Lm/W, built in pottted isolated electronic driver, surge voltage protection and othersafety test as IS 15885 Part-2/Sec 13 &CISPR 15,THD<10% Colour tempratire 5700K to 6000K,operating voltage range: 100-300V AC complete all as specified and directed. 13 Supply & fixLED Street Light Luminaire 25 watt 6000K with .high power LED cool white,CRI 75,+/- 5% supply voltage 220/240/50 Hz, light engine driver base.pole adapter,powder coated pressure die cast aluminium with heat resistant toughened glass with lens complete all as specified and directed. 14 Supply and fixing of LED T-8 tube light fitting with sinle side connection LED tube rod 18/20 W, 4 Feet made of CRCA sheet steel box type including bipin holder and connection with PVC insulated twin core 23/0.0076 ywisted copper cable from ceiling rode to light fitting complete all as specified and directed. 15 Supply and fixing street lightmounting bracket made out of GI pipe 40 mm dia light Grade not less than with 1.5(90cmx60cm) mtr long in any shapeincluding clamps, nuts, bolts, washers etc and painting with aluminium paint, complete all as specified and directed. 16 Supply and fixing in of sheet metal enlosure forDBs when MCBs to be used single door factory made flush fixed complete with 100 amps rated bus-bar 240 volts single phase 8 ways including necessary brick work and plaster to match with the existing surface complete all as specified and directed. 17 Supply and fixing in replacement Sheet metal enclosure for DBs when MCBs to be used double door factory made flush fixed complete with 200 Amps rated busbar 240 Volts single phase 8 ways complete all as specified and directed. 18 Supply and fixingwall mounted air circulator fan, heavy duty 300 mm sweep at 1200 RPM having cord controlled swing & 3/4steps speed complete all as specified and directed. 19 Supply, installation, commissioning of Glass Top Deep Freezer single phase 240 volt, 50 Hz of cap 320 LTR capacity complete all as specified and directed. 20 Supply, Installation & testing of voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between130V to 270V with out put voltage stabilized at 230V with accuracyof + 2.5% with time delay system and of caapcity4KVA complete all as specified and directed. 21 Supply and Fixing of Storage water heater (Geyser) of 50 litre capacity 230V AC, 50HZhaving element of 2 KW of COPPER/INCOLOY alloy , Rust proof outer body,highdensity PUF insulation, BEE 5 Star Rated ,Inner tank of SS 304 which can sustain pressure of minimum 7 Bar working pressure and having multifunction safety valve plug top , making electric and water connection complete all as specified and directed. 22 Supply and Fixing of Storage water heater (Geyser) of 25 litre capacity 230V AC, 50HZhaving element of 2 KW of COPPER/INCOLOY alloy , Rust proof outer body,highdensity PUF insulation, BEE 5 Star Rated ,Inner tank of SS 304 which can sustain pressure of minimum 7 Bar working pressure and having multifunction safety valve plug top , making electric and water connection complete all as specified and directed. 23 Supply and fixingof brass chormium plated angle valve, fancy typeof size 15mm dia screwed down for high pressure, complete all as specified and directed. 24 Supply and fixing of PVC Connection with stainless steel nuts (Hot/cold) of size 15 mm x 600 mm complete all as specified and directed. 25 Supply and fixing of Brass chromium plated fancy type bib tabs of size 15 mm diabore short body, screwed downfor GIpipe or for brass ferruleand fixed complete all as specified and directed. 26 Supply and fixing ofMCB SP single pole, 240 volts, 16 to 32 Amp, rupturing capacity 10 KA, ‘B’ series type complete all as specified and directed. 27 Supply and fixing of MCBs single pole (SP) 5 to 32 Amps with 10 KA breaking capacity of C series in distribution boards complete all as specifiedand directed. 28 Supply and fixing of MCB 40 Amps single pole with neutral, AC 230 Volts complete all as specified and directed. 29 Supply and fixing of MCB 40 Amps single pole , AC 230 Volts complete all as specified and directed. 30 Supply & fixingof single pole and neutral sheet metal enclosures with two pin & earth plug and socket with top complete with one single pole MCB of 20 Amps complete all as specified and directed. 31 Supply and fixing galvanized iron steel tubing medium grade 15 mm bore with all fitting and fixedto walls, ceiling and laid in floor complete all as specified and directed.Note- Quoted rate will include the cost of making water connection from existing supply line and making good of the wall surface etc all as specified. 32 Supply and fix in replacementfor sub main wiring with two run of single core (FRLS) PVC insulated and unsheathed cable with copper conductor (Multi strand) having nominal area2.5Sqmm drawing into and including PVC non metallic rigid conduit medium grade of adequate size and making electric connections including one run (FRLS) PVC insulated single core copper conductor cable 2.5 Sqmm as a earth continuity conductor(green colour) and including non metallic medium graderigid PVC conduit, including cutting chases in brick wall,and making good to match the existing specifications complete all as specified and directed by Engineer-in-Charge. Note :- (i)Rates are deemed to be included cutting and making holes in wall/floor for passing in or through conduit (ii)Two run of2.5 sqmm single core (FRLS) PVC insulated copper conductor cable, one run of 2.5 sqmm copper conductor cable (FRLS)as a earth lead and one run of PVC conduit of suitable size will be measured as a one unit. 33 Supply and fix in replacementfor sub main wiring with two run of single core (FRLS) PVC insulated and unsheathed cable with copper conductor (Multi strand) having nominal area6.0 Sqmm drawing into and including PVC non metallic rigid conduit medium grade of adequate size and making electric connections including one run (FRLS) PVC insulated single core copper conductor cable 6.0 Sqmm as a earth continuity conductor(green colour) and including non metallic medium graderigid PVC conduit, including cutting chases in brick wall,and making good to match the existing specifications complete all as specified and directed by Engineer-in-Charge. Note :- (i)Rates are deemed to be included cutting and making holes in wall/floor for passing in or through conduit (ii)Two run of6.00 sqmm single core (FRLS) PVC insulated copper conductor cable, one run of 6.0 sqmm copper conductor cable (FRLS)as a earth lead and one run of PVC conduit of suitable size will be measured as a one unit. 34 Supply and laying, in replacement, of LT underground cable XLPE insulated, inner PVC sheathed, galvanized steel strip armoured, PVC sheathed electric power cable with stranded compact aluminium conductor 1100 volts grade 16 Sq mm 4 core confirming to IS:7098 (Part-I) with latest amendements, suitable for earthed system laid in duct/trench/along pole etc . complete all as specified and directed.Note : 1. The cost of Aluminium thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.2. Excavation, earth work, DWC protection pipe will be measured and paid separately under respective items. 35 Supply and installation of octagonal poles 9 m long of Grade ISH430LA as per IS:5986:2017 latest Hot dip galvanisedas per IS:4759 latest: 610 g/m2 with top dia (A/F) 70 mm (minimum) bottom dia (A/F) -minimum 130 mm having thickness 3 mm base plate 200 mm x 200 m x 16 mm(minimum dimensions) including bolt as per Manufacturers instruction , having door opening of sizes 90 x 500 mm (minimum) above GL and having hot dip galvanized single arm bracket 1000 mm long for pole having top 70 mm A/F for mounting street light fitting fixed on top with nut bolts washers including provision of cable connector for three phases supply and one NoMCB SP of 0.5 A to 6A complete alongwith necessary iron work all as specified by manufacturer complete all as specified and directed.NOTE :-Excavation, earth work, PCC And RCC work is included in quoted rate. 36 Supply & fixing LED street light 90 W 230 volts with surge protection not less than 4 KV inbuilt in driver & minimum 10 KV separate in the light housing. Powder coated pressure die cast aluminium housing , IP-65/66 protection, high power LED street light with the heat resistant thoughened glass lensand making electrical connections pvc insulated sheathed 3 core 1.5 sqmm copper conductor from street light to junction box complete all as specified and as directed. Notes:- Driver shall be potted antivibration type. LM-79 and LM-80 for 50000 burning hours. CRI(colour Rendring Index) of fixture shall be ≥ 70. CCT (colour correlated Temp) of fixture shall be 5700K±300K. System Lumen Efficiency shall be>100 Lm/W. 10 KV separate Surge protection shall be provided as a part of fitting. PCB used shall be MC PCB type. The fitting shall have arrangement so that maintenance required , if any can be carried out from Top cover. 37 Supply and fixing in replacement FR grade thermoplastic polyethylene outdoor cable junction boxhinged/screwed door type of size 200x160x 98 mm for 3 Phase and Nutralincoming cable, 3 Phase and Neutral outgoing cable with terminals/connectorsand single Phase & Neutralconnection for light fitting, 4 pole, 415 volt and one MCB SP 6 Amp, 240 Volt and clamp system (screw less), shock proof safe IP-66, weather proof, rust, dust and water proof internally embedded gasket with provision metric knockouts for cable entry through gland suitable for 16sq mm to 25sq mm cableas required at site complete all as specified & directed. 38 Supply and fix in replacement distribution boards with40 Amps 3 pole 230 Volt Digital time switch for out door use, weather and vermin proofduly painted with synthetic enamel paint made out of 3.15mm thick CRCA sheetwith locking arrangementcomprising of one number time switch 24 hours operation Accuracy: quartz time base +/- 1 S per day, Power contractor 40 Amp , MCCB 4 pole of suitable size,manual switch and indicator suitable for street light operation and duly fixed on pole with clamps / Grouting on ground complete all as specified and directed. 39 Supply and fixing in replacementPVC insulated, PVC sheathed, multistranded copper conductor wire 1.5 Sqmm size, twin core complete all as specified and directed. 40 Supply and fixing / laying in replacement galvanized iron pipe of 40 mm nominal dia light grade fixed to poles with clamps nuts, bolts and washers or laid under road crossing or fixed to wallincluding painting with two coats of aluminium paint over a coat of red oxide paint complete all as specified and directed. 41 Material and labour for earthing completewith galvanisedsteelearth plateelectrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade)and watering pipe 20 mm bore GI pipe(light grade ) andchamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg.50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil and connecting to earth up to 6 meter length complete all as shown in electrical plate no 3 of SSR PART 1 , with charcoal dust and saltcomplete and earth leadconnected to earthing test point (up to main switche, DBs) complete all as specified and directed. 42 Excavation in trenches in any type of soil by not exceeding 1.5 m wide and not exceeding 1.5 m depth below ground level for foundation of poles/ stays/cable and getting out complete all as specified and directed. 43 Returning, filling in, any type of soil and spreading in layers not exceeding 25cm thick each layer including watering & well ramming complete all as specified and directed. 44 Removal of surplus soil to a distance not exceeding 50 mtr & depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and directed. 45 Supply,laying & fixing double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints,Sockets,Elbows,bends and End caps etc.complete all as specified and directed.

Key Value

Document Fees
INR 500 /-
EMD
INR 31500.0 /-
Tender Value
INR 15.65 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail