}

Supply, Delivery And Installation Of Different Spare Parts At Vcb Panel, Oil Filtration At Transformer, Rectification Of Backwash Feeder Panelother Allied Works At Sub-Station Building And High Lift Pump House Of Dariapur Water Treatment Plant Within Mald, malda-West Bengal

Public Health Engineering Department has published Supply, Delivery And Installation Of Different Spare Parts At Vcb Panel, Oil Filtration At Transformer, Rectification Of Backwash Feeder Panelother Allied Works At Sub-Station Building And High Lift Pump House Of Dariapur Water Treatment Plant Within Mald. Submission Date for this Tender is 20-05-2025. Circuit Breakers Tenders in malda West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

49116405
Supply, Delivery And Installation Of Different Spare Parts At Vcb Panel, Oil Filtration At Transformer, Rectification Of Backwash Feeder Panelother Allied Works At Sub-Station Building And High Lift Pump House Of Dariapur Water Treatment Plant Within Mald
Open Tender
Indian
West Bengal
Malda
20-05-2025

Tender Documents

Tender Details

supply, delivery and installation of different spare parts at VCB panel, Oil filtration at Transformer, Rectification of Backwash feeder panelother allied works at Sub-station building and High Lift Pump house of Dariapur Water Treatment Plant within Malda Arsenic area W/S scheme (Southern Sector) under MLMD, PHE DTE- 1 SINGLE PANEL VCB : 2 Supply and delivery of Tripping Circuit Fuse (6 amp. glass fuse) 3 Supply and delivery of Various hardware materials like High Tension Nut Bolt, Washer etc. 4 Supply and delivery of Tripping Coil for ESPL make 11 KV VCB Coil Voltage: 110 V DC 5 Supply and delivery of Closing Coil for ESPL make 11 KV VCB Coil Voltage: 110 V DC 6 Supply and delivery of Indicating lamp (LED) supplyGreen – 1 No., Blue – 1 No. 7 Charges for attending on Fault, Power Circuit checking, Control Circuit checking, Fault Identification, Panel checking, Trip circuit fuse replacement, Tripping coil replacement, Closing coil replacement, hardware materials fitting/fixing etc. 8 TRANSFORMER-2 (750 KVA, 11 / 0.433 KV) 9 Charges for All kinds of Gaskets& oil seal supply for HT & LT bushings, top cover, inspection cover, valve etc. of 750 KVA, 11 KV /0.433 KV Transformer 10 Charges for gasket changes for 750 KVA, 11 / 0.433 KV Transformer by disconnecting of all HT & LT terminals, draining transformer oil, opening of top cover, arresting of any oil leakage by changing of gasket & oil seal respectively various gasket portion like top cover, inspection cover, tap switch, conservator tank, radiators, buchholz, drain valve(As where required) & HT-LT bushing portion 11 Charges for Oil Filtration of transformer. 12 Supply and delivery and replacement of Silica Gel. 13 Charges for Di-Electric Strength Test (BDV Test) 14 Supply delivery of New Oil Transformer Oil 15 TRANSFORMER-3 (750 KVA, 11 / 0.433 KV) 16 Charges for Oil Filtration of transformer. 17 Supply and delivery and replacement of Silica Gel. 18 Charges for Di-Electric Strength Test (BDV Test) 19 Supply delivery of New Oil Transformer Oil 20 UPS : 21 Supply delivery of 12 V Battery Make: Exide, Type: EP 42-12 Capacity: 42 Ah 22 Charges for Replacement of 16 Nos. 12 V battery 23 Laying & socketing of Cable at High Lift pump house. 24 Supply delivery of 240 sq. mm heavy duty Alu. Socket. 25 Charges for Attending on Fault, Fault Identification &rectification, Laying of 44 Mtrs.1.1 KV grade 4C, 300 sq. mm., XLPE insulated Al, Ar, Cable, 24 nos LT End Termination with Cable socketing 240/300 sq.mm. cable and DC fault rectification at HT site. 26 FAULT IDENTIFICATION & RECTIFICATION WORK OF BACKWASH FEEDER OF HIGH LIFT PUMP HOUSE AT DARIAPUR WTP 27 18.5 KW BACK WASH PUMP FEEDER- 1 28 Charges for Emergency basis attending on Fault,thoroughly Power & Control circuit checking, FaultIdentification, Fault rectification by replacing defective MCCB from pump no-2 to pump no-1 29 18.5 KW BACK WASH PUMP FEEDER- 2 30 Charges for Emergency basis attending on Fault,thoroughly Power & Control circuit checking, FaultIdentification 31 18.5 KW BACK WASH PUMP FEEDER- 3 32 Supply delivery of Power Contactor CL 45 (make- GE, 220 V) 33 Supply delivery of Add ON Block. 34 Charges for Emergency basis attending on Fault,thoroughly Power & Control circuit checking, FaultIdentification, Fault rectification by Replacement of 2nos power contactor, 5 nos NC Add-ON Block & 2 nosNO Add-ON Block. 35 Add GST @ 18% 36 Add Cess @ 1%

Key Value

Document Fees
Refer document
EMD
INR 8100.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail